DESCRIPTION
TheOC‐3SmallForm‐FactorPluggableCWDM,1491nm(SFP
OC3)plugsintoADTRANOC‐3equipmentdesignedtoaccept
SmallForm‐FactorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC3providesan
OC‐3CWDMinterfacetothesupportingsystem.
Toensurecompatibility,refertothedocumentationprovi ded
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC3:
♦ SONETOC‐3compatible(155.52Mb/s)1491nm,
longreach,single‐mode,2‐fiberoperation
♦ 80kmmaximumopticalspan
Duetocompliancecertificationrequirements,use on lySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦ OpticalSpecifications:
◊ Opticaltransmitlevel:0dBmto–5dBm
◊ Opticalreceivelevel:–10dBmto–34dBm
◊ Powerpenalty:–1dB
◊ Opticalbudget:28(±1)dBm
◊ Minimumspanattenuation:10dB
◊ Opticalconnectors:LC
♦ ExtendedEnvironmentalSupport:
◊ Operationaltemperaturerange:–40°Cto+65°C
◊ Storagetemperaturerange:–40°Cto+85°C
◊ Relativehumidityto95%,noncondensing
OC-3 Small Form-Factor Pluggable
CWDM, 1491 nm
INSTALLATION
ToinstalltheSFPOC3intoanappropriatemodule,completethe
followingsteps:
1. InspecttheSFPOC3.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC3intotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheSFPOC3allthewayintothereceptacleuntilthere
isanaudible“click”.
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC3 is not directly provisionable. To provision the
SFPOC3, access the menu system of the host module. Refer
to the “Provisioning” section of the Job Aid or Installation
and Maintenance Guide (I&M) provided with the host
module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
ElectrostaticDi schar ge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccom pon ents .Placemodulesin
antistaticpackingmaterialwhentranspo rtingorstoring.When
wor kin g on modules, always placethem on an approved
antistaticmatthatiselectricallygrounded.
TheSFPOC3isNRTLListedtotheapplicableULstandards.The
SFPOC3meetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC3isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC3istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference
CLEI: SITRAAGA_ _
Product P/N: 1442701PG2
Issue Date: November 2010
Document P/N: 61442701PG2-22C