DESCRIPTION
TheOC3SmallFormFactorPluggableCWDM,1471nm(SFP
OC3)plugsintoADTRANOC3equipmentdesignedtoaccept
SmallFormfactorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC3providesan
OC3CWDMinterfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovi ded
withthehostmodule.
The following features are supported on the SFP OC3:
SONETOC3compatible(155.52Mb/s)1471nm,
longreach,singlemode,2fiberoperation
80kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,use on lySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
OpticalSpecifications:
Opticaltransmitlevel:0dBmto–5dBm
Opticalreceivelevel:–10dBmto–34dBm
Powerpenalty:–1dB
Opticalbudget:28(±1)dBm
Minimumspanattenuation:10dB
Opticalconnectors:LC
ExtendedEnvironmentalSupport:
Operationaltemperaturerange:–40°Cto+65°C
Storagetemperaturerange:–40°Cto+85°C
Relativehumidityto95%,noncondensing
OC-3 Small Form-Factor Pluggable
CWDM, 1471 nm
INSTALLATION
ToinstalltheSFPOC3intoanappropriatemodule,completethe
followingsteps:
1. InspecttheSFPOC3.Ifdamaged,fileaclaimwiththecar
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC3intotheSFPcageonthemodule.Ensure
thatthemanufacturerslabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheSFPOC3allthewayintothereceptacleuntilthere
isanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC3 is not directly provisionable. To provision the
SFPOC3, access the menu system of the host module. Refer
to the “Provisioning” section of the Job Aid or I&M provided
with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDi schar ge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccom pon ents .Placemodulesin
antistaticpackingmaterialwhentranspo rtingorstoring.When
wor kin g on modules, always placethem on an approved
antistaticmatthatiselectricallygrounded.
TheSFPOC3isNRTLListedtotheapplicableULstandards.The
SFPOC3meetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR63CORE,GR1089CORE,andETSIEN
300368.
TheSFPOC3isintendedfordeploymentinCentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC3istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SITRAAFA_ _
Product P/N: 1442701PG1
Issue Date: November 2010
Document P/N: 61442701PG1-22C
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442701PG1-22C*
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹs
authoritytooperatethisequipment.
CAUTION
C
TheSFPOC3containsaClass1laserthatcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1 040.10and1040.11,andEN
608251,and‐2.TheSFPOC3isNRTLListedandCBCertifiedto
allapplicableAmericanandEuropeansafetystandards.
CAUTION
!
PerGR1089CORESection9,theSFPOC3 does not have an
internal DC connection between battery return and
frame ground.
TheADTRANsystemthattheSFPOC3isbeingdeployedinis
designedandinte ndedforins tall ationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
TheSFPOC3canbeinstalledinaDCI(isolated)orDCC
(common)configuration.Forinstallationswher eothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbe intendedfor
deploymentonlyinaDCCconfiguration.
TheADTRANsystemchassis framegroundterminalmustbe
connectedtoareliableearth ground toensurethatthemetal
enclosureof theSFP OC3is pr operlygrounded vi athe
backplaneconnector.
NOTE
TheOC3port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR108 9CORE
Issue5.
ThisSFPOC3iscompliantwithSFF8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,Revision9.3.
This SFPOC3 iscompliant with theSmall FormFactor
Pluggable(SFP)MultiSourceAgreement(MSA).
Thi sproductisdesigned to bedeployedinGR3108CORE
environmentclass1or2asdefinedinGR3108COREissue2.
TheSFPOC3isdesignedtomeetthefollowingenvironmental
classes:
ETSIEN30001911“Classificationofenvironmental
conditions;Storage,”Class1.2
ETSIEN30001912“Classificationofenvironmental
conditions;Transportation,”Class2.3
ETSIEN30001913“Classificationofenvironmental
conditions;Stationaryuseatweatherprotectedlocations,”
Class3.3
ETSIEN300386“ElectromagneticcompatibilityandRadio
spectrumMatters(ERM);Telecommunicationnetwork
equipment;ElectromagneticCompatibility(EMC)
requirements”
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli
cableexemptions.Refertowww.adtran.com
forfurtherinfor
mationonRoHS/WEEE.