Accuro LYNK2 User manual

  • Hello! I am an AI chatbot trained to assist you with the Accuro LYNK2 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
61PQuickUSERGUIDE
Pleasefullycharge61Pbeforestartusingit.
Charging
Important:Mak esurethe twochargingcontacts on thebackofthe61P areclean anddry.Ifthey
arewet,patthemgentlywithadrytowel.
Thebatterylevel isdisplayed inAccurofit appwhen 61Pisconnected. 61Pwilldisplaythe
fo llowinglightindicatortodisplayitsbatterystatus: Theredlightwillflashtwice.
1. PlugtheUSBchargerintotheUSBportofyourcomputerorUSBchargers
2. AlignthetwochargingcontactsonthebackoftheSLICEtothetwochargingpinsontheUSB
charger.Themagnetsinthechargerwillhelpthetwopieceslockintoplace.
3. Thescreenwilldisplayapulsingyellowlighteveryfewsecondstoindicatethatthebatteryis
charging.
4. Itwilltakeapproximately2hoursto fullycharge.Whenthe61Phaschargedcompletely,a
greenindicatorligh twillpulse.Eachfullch argewillprovideupto57daysofnormaluse.
LightIndicator sDefinition:
# Function Indicator color Indicatorflash
1 Turnon C
y
an 1
2 Turno
f
f
C
y
an 3
3 Settoworkoutmode Cyan+Pinkorcurrentheart
ratezonecolor
1+3
4 Settoalldaymode Pink or current activity zone
color+cyan
2+2
5 lowbattery Red 2
6 Charging Yellow pulse
7 Fullcharge G
r
een pulse
8 Reset/enterpairingstatus Red 3+2+1
9 Ready
f
or pairing Red Flash30s
10
P airing confirmation(needs
topressbutton)
Blue Flash50s
11 EasyHeart RateZone Blue 5
12 LightHeart RateZone G
r
een 5
13 Mode
r
ate HeartRateZone Yellow 5
14 IntenseHeartRateZone Orange 5
15 Vigo
r
ousHeartRateZone Red 5
16
Check cur
r
ent Heart Rate
Zone(Pressthebutton)
currentHeartRa tezonecolor 2
Gettingstarted
61P’sdefaultstateissetasturnedoffwhendelivered.Inordertoturnon61P,pleasetriple
click
thebutton.When61Pisturnedon,itwillvibrateandacyanlightindicatorwillflash.
SetUp
AccurofitappisavailableatApplestoreandGooglePlay
OpentheAccur ofitapponyoursmartphoneandfollowtheprompts:
1. Createanewaccount,orsigninifyoualreadyhaveanAccurofitaccount
2. Completeyouruserprofile
3. Theappwillnowguideyoutopair61Ptoyourphone
Pairing61PtoYourSmartphone
1. When61P is charging,hold the button to allow 61P to enter reset/paringmode.After
entering paring mode, 61P will be vibr ating 3 times and a red light will be flashing, Now
61Pcouldberemovedfromthecharger.
2. OpenAccurofitapp,gotosettingspage‐addheartratedevice,thenselect61P, theAppwill
start searching for Bluetooth discoverable devices. Be sure to k eep 61P as close as
possibletoyourphone.
3. In the app, select the 61P that appears in the list. If multiple devicesappear, bring your
61P
asclose as possible to your phone. Tap [Try again]to refresh the list,thenselect the
oneat
the top of the list. If no device was shown, check whether 61P is still blinking red light, if
not, please hold thebutton until the red lightstarts to flash. When61P is flashing
redlight,
itmeansthedeviceisreadyforparing.
4. When 61Pflashesbluelight,pleasepressbuttontoconfirmpairing.
5. Your 61P is now paired to your phone and will reconnect automatically when it is within
range.Your61Pcannotbeconnectedtoanotherphoneunlessbeingreset.
Poweroff
Inordertoturnon61P,pleasetripleclickthebutton.When61Pisturnedon,itwillvibrate
anda
cyanlig htindicatorwillfadeout.
WorkoutMode
61Phas2modes,alldaymodeandworkoutmode.
1. 61P automatically tracks your heart rate, PAI score, active calories, steps, distance, and
sleepdatainAllDayMode
2. To record an activity, put 61P into Workout Mode by pressing down the button for 2
seconds. 61P will vibr
ate 3 times and flash the indicator, then enter the workout mode. In
Workout Mode, 61P uses high intensity sampling rate, capturing your heart rate every
second.
3. To end and save the activity session, press down the button for 2 seconds . 61P will exit
WorkoutMod
eandreturntoAllDayMode.61Pwillvibrate2timesandflashtheindicator.
FCCStatement
Any Changes or modifications not expressly approved by the party responsible for compliance
couldvoidtheusersauthoritytooperatetheequipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:(1)Thisdevicemaynotcauseharmfulinterference,and
(2) This device must accept any interfer ence received, including int erference that may cause
undesiredoperation.
ISEDRSSWarning:
ThisdevicecomplieswithInnovation,ScienceandEconomicDevelopmentCanadalicenceexempt
RSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynot
causeinterference,and(2)thisdevicemustacceptanyinterference,includinginterferencethat
may
causeundesiredoperationofthedevice.
LeprésentappareilestconformeauxCNRd'ISEDapplicablesauxappareilsradioexemptsde
licence.L'exploitationestautoriséeauxdeuxconditionssuivantes:
l'appareilnedoitpasproduiredebrouillage,et
l'utilisateurdel'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesilebrouillage
estsusceptibled'encompromettrelefonctionnement.
ISEDRFexposurestatement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled
environment.The device has been evaluated to meet general RF exposure requirement.
Le matériel est conforme aux limites de dose d'exposition aux rayonnements énoncés pour fac
un autre environnement.ce dispositif a été évalué à satisfaire l'exigence générale de l'exposition
aux rf.
FCC RF exposure statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment.The device has been evaluated to meet general RF exposure requirement.
/