Dacor HRTP486SNGH User guide

Category
Cookers
Type
User guide
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
®
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 10/17/14 Page 1/4
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
IMPORTANT: Installation of a non-combustible material (up to the hood) or
a backsplash is always recommended, and mandatory if the distance to the
back wall from the rangetop is less than 2 1/2” (Figure 2). When installing
a backguard, use only Dacor model numbers AEB3609 (DYRTP366) or
AEB4809 (DYRTP486). Consult local codes and ordinances for acceptable
non-combustible materials.
CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD
CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD
PRODUCT DIMENSIONS - SIDE VIEW
PRODUCT DIMENSIONS - ISO VIEW
A - Width
DYRTP366 35 7/8” (91.1 cm)
DYRTP486 47 7/8” (121.6 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
A
3 3/8”
(8.6 cm)
7/16”
(1.1 cm)
7 3/4”
(19.7 cm)
Trim:
1/4”
(6.4 mm)
thick
25 3/8” (64.5 cm)
1 1/4” (3.2 cm) cooking surface
height (grate level) above
countertop
3/4” NPT gas inlet, connects to regulator
from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
26 5/16” (66.8 cm)
27 5/16” (69.4 cm)
Power cord
40” long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (6.4 cm) min. to
combustible rear wall
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 10/17/14 Page 2/4
Recommended
gas and electrical
service location,
consult local code
B
10” (25.4 cm) to
combustible side
wall min. both sides
1/2” (1.3 cm)
overhang,
both sides
1 1/2” (3.8 cm)
typical countertop
thickness
7 3/4”
(19.7 cm)
36” (91.4 cm)
typical
Mounting platform
1” (2.5 cm) min.
thickness
Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted.
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
CABINET/COUNTERTOP DIMENSIONS -
ISO VIEW
continued on following pages...
See note 2
2
See Cabinet/Countertop Dimensions - Top View
3
This specification not applicable for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the rangetop.
1
Vertical to combustible surface from rangetop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
C
13” (33.0 cm)
max.
3
Top of
finished
counter
Grate
level
Grate
level
15” (40.6 cm)
min.
1, 3
30” (76.2 cm)
min.
1
Cutout for
utility access
Model No. B C
DYRTP366 36” (91.4 cm)
36” (91.4 cm)*
42” (106.7 cm)**
DYRTP486 48” (121.9 cm)
48” (121.9 cm)*
54” (137.2 cm)**
* Minimum ** Recommended
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 10/17/14 Page 3/4
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW
INSTALLED RANGETOP - SIDE VIEW
Model No. B - Cutout Width D - Hole Offset
DYRTP366 36” (91.4 cm) 16 5/8” (42.2 cm)
DYRTP486 48” (121.9 cm) 20 13/16” (52.9 cm)
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Non-combustible
rear wall, rear of
mounting platform
10” (25.4 cm) min.
to combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
Increase countertop and overhang
additional 2 1/2” (6.4 cm) min. for
combustible rear wall above
countertop
3/8” (1.3 cm)
countertop overhang
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
11 7/16”
(29.1 cm)
24”
(63.5 cm)
min.
cabinet
depth
C
L
D D
B
C
L
C
L
C
L
Gas connection and power cord may be
routed through bottom or back of chassis
Gas and electrical connections at
right rear section of chassis
Cabinet
face
Installed control
panel overhang
1/3/8” (3.5 cm)
24” (61.0 cm)
Countertop
Mounting platform
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 10/17/14 Page 4/4
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW
CABINET/COUNTERTOP CUTOUT DIMENSIONS
WITH DOWNDRAFT VENT - SIDE VIEW
Model No.
B - Cutout
Width
D - Hole
Offset
E - Downdraft
Vent Cutout
DYRTP366
36”
(91.4 cm)
16 5/8”
(42.2 cm)
33 1/2”
(85.1 cm)
DYRTP486
48”
(121.9 cm)
20 13/16”
(52.9 cm)
43 1/2”
(110.5 cm)
Model No.
Approved Downdraft
Vent Models
DYRTP366 ERV36, ERV3615, PRV36
DYRTP486 ERV48, PRV48
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
IMPORTANT: Use only the downdraft vents specified.
Non combustible rear
wall recommended
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (1.0 cm) min.
countertop overhang
2 5/8”
(6.7 cm)
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for raised
vent, gas and electrical connections
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
11 7/16”
(29.1 cm)
C
L
D
D
E
B
C
L
C
L
C
L
26 5/8”
(67.6 cm)
min.
cabinet
depth
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
15”
(38.1 cm)
Stiffener
Cabinet face
Control panel
overhang
1 3/8” (3.5 cm)
Countertop
Dacor approved
downdraft vent
IMPORTANT: See downdraft
installation instructions for
duct system layout/planning
DYRTP366 or
DYRTP486 rangetop
3/8” min. (1.0 cm)
space behind
downdraft vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Minimum
countertop
height:
30 1/4"
(76.8 cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Dacor HRTP486SNGH User guide

Category
Cookers
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI