Dacor HRTP486SNG Installation guide

Category
Cookers
Type
Installation guide

This manual is also suitable for

Dacor HRTP486SNG is a rangetop with advanced features designed to make cooking easier and more enjoyable. Its 48-inch width provides ample space for multiple pots and pans, while the high-powered burners deliver precise temperature control for consistent results. The rangetop also features a built-in griddle, perfect for cooking pancakes, eggs, and other breakfast favorites.

Dacor HRTP486SNG is a rangetop with advanced features designed to make cooking easier and more enjoyable. Its 48-inch width provides ample space for multiple pots and pans, while the high-powered burners deliver precise temperature control for consistent results. The rangetop also features a built-in griddle, perfect for cooking pancakes, eggs, and other breakfast favorites.

Installation Instructions
Heritage Rangetop
HRTP366, HRTP486
Part No. 113928 Rev. B
THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST
EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES.
Installation Instructions .................................................... 8
Rangetop Installation ....................................................... 8
Gas Line Connection ....................................................... 9
Burner Component Installation ...................................... 10
Burner Knob Installation ..................................................11
Verifying Proper Operation ............................................. 12
Installation Checklist ...................................................... 13
Wiring Diagram ................................................................ 14
Notes................................................................................. 15
Table of Contents
Before You Begin...
Important Safety Instructions .......................................... 1
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
Installation Requirements ................................................ 3
Electrical Requirements ................................................... 3
Gas Supply Requirements ............................................... 3
Product Dimensions ......................................................... 3
Cabinet and Countertop Layout ....................................... 4
Cabinet/Cutout Dimensions ............................................. 5
All specifications are subject to change without notice. Dacor
assumes no liability for changes to specifications.
Important:
Installer: In the interest of safety and to minimize problems, read these installation instructions completely and care-
fully before you begin the installation process. Leave these installation instructions with the appliance.
Customer: Keep these installation instructions for future reference and the local building inspector’s use.
© 2018 Dacor, all rights reserved.
CALIFORNIA PROPOSITION 65 WARNING
The burning of gas cooking fuel generates some by-products that are on the list of substances which are known by
the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of
potential exposure to such substances. To minimize exposure to these substances, always operate this unit according
to the use and care manual, ensuring you provide good ventilation when cooking with gas.
If You Need Help...
If you have installation issues or repair/operation/warranty
questions, contact Dacor Customer Assurance. Before call-
ing, have available the rangetop model and serial numbers,
which are on the data label on the chassis bottom.
Dacor Customer Assurance
Phone: 833-35-ELITE (833-353-5483 USA, Canada
Mon – Fri 5:00
a.m. to 5:00 p.m. Pacific Time
Website: www.dacor.com/customer-care/contact-us
Customer Service Information
Product Data Label
The product data label contains the model and serial
number information and the electrical and gas supply
requirements.
It is attached to the bottom of the chassis.
Model Identification
HRTP366S/NG/H
SIZE (in inches)
GAS TYPE
NG = Natural Gas
LP = Liquid Petroleum
(Propane)
ALTITUDE
H = High Altitude Model, 4000 ft.(1219 m) and up
No character = Equipped for low altitude operation
1
Important Information About
Safety Instructions
The Important Safety Instructions and warnings in
this manual are not meant to cover all possible prob-
lems and conditions that can occur. Use common
sense and caution when installing, maintaining or oper-
ating this or any other appliance.
Always contact Dacor Customer Assurance with issues
and conditions you cannot resolve. See If You Need
Help... (previous page).
Important Safety Instructions
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal
injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor
personal injury or property damage.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN
THE EVENT OF A RANGE TOP GREASE FIRE:
a. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN - you may be
burned.
c. DO NOT USE WATER, including wet dish cloths or
towels - a violent steam explosion may result.
d. Use a fire extinguisher ONLY if:
◊ You have a Class ABC extinguisher, and you
already know how to operate it.
◊ The fire is small and contained in the area where
it started.
◊ The fire department is being called.
◊ You can fight the fire with your back to an exit.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not use any phone in your build-
ing.
Immediately call your gas supplier
from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WARNING
WARNING – NEVER use this appliance as a space
heater to heat or warm the room. Doing so may result
in carbon monoxide poisoning and overheating of the
appliance.
WARNING
WARNING – NEVER cover any slots, holes or passages
on the rangetop or rangetop chassis. Doing so blocks
air flow through the rangetop and may cause carbon
monoxide poisoning. Aluminum foil linings may also trap
heat, causing a fire hazard. Keep all slots, holes and
passages clear of grease and grime.
READ AND SAVE THESE INSTRUCTIONS
2
Important Safety Instructions
Read the accompanying use and care manual com-
pletely before operating this appliance.
Keep packaging materials away from children.
Plastic sheets and bags can cause suffocation.
If you receive a
damaged product, immediately con-
tact your dealer or builder. Do not install or use a
damaged appliance.
This rangetop must be properly installed and ground-
ed by a qualified installer according to these instal-
lation instructions prior to use. The installer should
show the customer the location of the gas shut off
valve and the electrical outlet so that they know
where and how to turn off the gas supply and dis-
connect power to the rangetop. Proper installation is
the responsibility of the customer.
This appliance is not designed for installation in a
mobile home or recreational vehicle.
Installations with less than 2 1/2” (6.4 cm) from the
rear of the rangetop to a combustible material must
use a non-combustible material. See the latest
version of ANSI Z223.1.
Do not use this appliance in combination with a
surface (countertop) ventilation system, air curtain or
other type of range hood that directs airflow in a
downward direction.
Do not install, repair or replace any part of the ran-
getop unless specifically recommended in the litera-
ture accompanying it. A qualified service technician
should perform all other service. Do not tamper with
the controls. Do not operate the rangetop without the
knobs and trim rings in place.
Before cleaning, servicing or installing this rangetop,
make sure that the gas supply is turned off at the gas
supply valve and that the power plug is discon-
nected from the electrical outlet.
Do not connect this rangetop to the gas supply with-
out the supplied gas pressure regulator installed.
Clean this appliance only in the manner specified in
the use and care manual.
Only use the rangetop for cooking tasks expected of
a home appliance as outlined in the literature accom-
panying it. This rangetop is not intended for commer-
cial or laboratory use.
WARNING
General Safety Precautions
To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precau-
tions, including the following:
DO NOT TOUCH THE SURFACES OF THE
Rangetop OR THE SURROUNDING AREAS DURING
OR IMMEDIATELY AFTER USE
.
Do not climb on any part of the appliance.
To avoid a fire hazard, do not hang flammable or
heat sensitive objects over the rangetop.
Do not leave children alone or unattended in the
area around the rangetop. Do not allow children
to play with the controls or touch other parts of the
rangetop. Do not store items of interest to children
on top of or above the rangetop. Children could be
burned or injured while climbing on the appliance.
Clean the rangetop thoroughly before operating it for
the first time. Make sure that all the rangetop parts
are dry before lighting a burner.
Keep flammable items, such as paper, cardboard,
plastic and cloth away from the burners and other
hot surfaces. Do not place such items on the ran-
getop. Do not allow pot holders to touch hot surfaces
or gas burners.
Do not wear loose or hanging apparel while using
the rangetop. Do not allow clothing to come into con-
tact with the rangetop and surrounding areas during
and immediately after use. Do not use towels or
bulky cloth as pot holders.
If the rangetop is near a window, do not use long
curtains as window treatment. The curtains could
blow over the rangetop and create a fire hazard.
IMPORTANT - This appliance is equipped with a
three prong grounding plug for your protection against
possible electric shock hazards.
Plug it only into a dedicated,
grounded three prong electrical
outlet. It is the responsibility
of the customer to make sure
the proper type of outlet is
installed. Do not under any
circumstances:
Cut or remove the third (ground) prong from the
power cord.
Use an adapter plug.
Use an extension cord.
Use a power cord that is frayed or damaged.
Connect to an electrical outlet with a ground fault
interrupter (GFI).
WARNING
3
Product Dimensions
WIDTH (A)
HRTP366 35 7/8” (91.1 cm)
HRTP486 47 7/8” (121.6 cm)
Installation Requirements
WARNING
The installation of this appliance must conform with
local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
To prevent an electric shock hazard, the power sup-
ply must meet the specifications stated below.
The electrical and gas supply data on this page is for refer-
ence only. If the requirements below do not agree with the
product data label, use the data on the product data label.
Electrical Requirements
The appliance installation must be electrically grounded
in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70.
The correct voltage, frequency and amperage must be
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis.
The electrical outlet must be installed by a licensed
electrician in an accessible location so that the power
cord may easily be disconnected during cleaning and
service.
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60 Hz,
15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
Gas Supply Requirements
Check your local building codes for the proper method
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. The
gas service must be installed by a qualified profes-
sional.
Be certain that the rangetop being installed is cor-
rect for the gas service being provided (natural gas or
LP gas). Also, if operating the rangetop at an altitude
above 4000 ft. (1219 m) make sure it is equipped for
high altitude operation. See the inside cover for more
information.
An external manual shut-off valve must be installed
between the gas inlet and the rangetop for the purpose
of turning on or shutting off gas to the appliance.
The factory provided regulator shipped with the appli-
ance must be installed in the gas line that runs from the
gas shut off valve to the rangetop gas inlet. Use only
the regulator provided. The regulator inlet accommo-
dates a 3/4” gas supply line and is also compatible with
a 1/2” house gas supply. The inlet to the rangetop itself
is equipped with a 3/4” male NPT fitting.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold
Pressure
Minimum Gas
Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP)
10” Water
Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
A
3 3/8”
(8.6 cm)
7/16”
(1.1 cm)
7 3/4”
(19.7 cm)
Trim:
1/4”
(6.4 mm)
thick
25 3/8” (64.5 cm)
1 1/4” (3.2 cm) cooking surface
height (grate level) above
countertop
3/4” NPT gas inlet, connects to regulator
from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
26 5/16” (66.8 cm)
27 5/16” (69.4 cm)
Power cord
40” long
Product tolerances: ±1/16” (±1.6 mm) unless otherwise
noted.
SIDE VIEW
4
Cabinet and Countertop Layout
WARNING
To avoid the risk of fire or personal injury, all minimum
and maximum specified clearances on this and the
following pages must be maintained or exceeded.
General Considerations
The minimum distance from the back of the rangetop
to a combustible rear wall is 2 1/2” (6.4 cm) minimum
(Figure 1).
Installation of a non-combustible material (up to the
hood) or
a backsplash is always recommended, and
mandatory if the distance to the back wall from the
ran-getop is less than 2 1/2” (Figure 2). Consult local
codes and ordinances for acceptable non-combustible
materials.
Carefully check the location where the rangetop is
to be installed. For best performance, the rangetop
should be installed away from drafts caused by doors,
windows and heating and air conditioning outlets. To
reduce the risk of personal injury from reaching over a
hot appliance, avoid cabinet installations directly above.
All contact surfaces between the rangetop and the
counter must be solid and level.
Installation Requirements
To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor strongly rec-
ommends installing a range hood or downdraft vent. A
hood should project horizontally a minimum of five (5)
inches beyond the face of the cabinets.
The installation must allow access to the underside
of the rangetop for service and inspection purposes,
including the ability to turn off the rangetop gas supply
valve and electrical outlet.
The countertop overhang on the sides of the cutout
shown on the following pages covers the recessed por-
tions of the rangetop behind the control panel and cre-
ates a seamless look for the installation.
IMPORTANT: When installing the rangetop into a lami-
nated or synthetic countertop, radius the corners of the
cutout to help avoid cracking. Consult the countertop
manufacturer’s instructions for minimum corner radius,
reinforcement and heat protection requirements.
For installations with a downdraft vent, install this appli-
ance only with the approved Dacor downdraft vent
models listed on page 6.
Gas and Electric Service Location
A manual gas shut-off valve must be installed in an
accessible location in the gas line external to the appli-
ance for the purpose of turning on or shutting off gas to
the appliance.
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere
with the rangetop when it is installed. If installing anoth-
er appliance in the cabinet below, allow for the routing
of gas and electrical service out the back of the unit.
The shaded area on the facing page shows the rec-
ommended location of the gas inlet and the electrical
outlet. For replacement purposes, the location of the
existing utilities may be utilized provided they do not
interfere with the sides or rear of the rangetop. Check
local building codes for permissible utility locations.
For best performance and to minimize gas pressure
loss, attach the gas supply regulator as close as pos-
sible to the rangetop gas inlet.
The installation must:
Allow for access to the gas shut-off valve and regulator
when the unit is installed.
Allow for access to the electrical outlet, when the ran-
getop is in place so that the power cord may be easily
disconnected if the unit needs service.
Allow for connection of the (40”) power cord to the
electrical outlet.
If a downdraft vent is to be installed, allow for access
to the gas supply valve and electrical outlet when the
downdraft vent is in place.
Non-combustible material or
backsplash mandatory if gap
from back of cooktop to
combustible wall is less than
2 1/2”
Combustible
rear wall
2 1/2” (6.4 cm) min. to
combustible rear wall
FIGURE 1
FIGURE 2
Combustible
rear wall
5
Recommended
gas and electrical
service location,
consult local code
B
10” (25.4 cm) to
combustible side
wall min. both sides
1/2” (1.3 cm)
overhang,
both sides
1 1/2” (3.8 cm)
typical countertop
thickness
7 3/4”
(19.7 cm)
36” (91.4 cm)
typical
Mounting platform
1” (2.5 cm) min.
thickness
Installation Requirements
Cabinet/Cutout Dimensions
Cabinet/Countertop Dimensions - Front View
Cabinet/Countertop Dimensions -
ISO View
Cabinet tolerances ±1/16” (±1.6 mm) unless otherwise noted.
continued on following
pages...
See note 2
2
See Cabinet/Countertop Dimensions - Top View
3
This specification not applicable for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the rangetop.
1
Vertical to combustible surface from rangetop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
C
13” (33.0 cm)
max.
3
Top of
finished
counter
Grate
level
Grate
level
15” (40.6 cm)
min.
1, 3
30” (76.2 cm)
min.
1
Cutout for
utility access
Rangetop
Model
B C
HRTP366 36” (91.4 cm)
36” (91.4 cm)*
42” (106.7 cm)**
HRTP486 48” (121.9 cm)
48” (121.9 cm)*
54” (137.2 cm)**
* Minimum ** Recommended
6
Cabinet/Countertop Dimensions (cont.)
Installation Requirements
Non-combustible
rear wall, rear of
mounting platform
10” (25.4 cm) min.
to combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
Increase countertop and overhang
additional 2 1/2” (6.4 cm) min. for
combustible rear wall above
countertop
3/8” (1.3 cm)
countertop overhang
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
11 7/16”
(29.1 cm)
24”
(63.5 cm)
min.
cabinet
depth
C
L
D D
B
C
L
C
L
C
L
Rangetop
Model
B - Cutout
Width
D - Hole
Offset
E - Downdraft
Vent Cutout
Approved Downdraft
Vent Models
HRTP366
36”
(91.4 cm)
16 5/8”
(42.2 cm)
33 1/2”
(85.1 cm)
MRV3615S
HRTP486
48”
(121.9 cm)
20 13/16”
(52.9 cm)
43 1/2”
(110.5 cm)
MRV48S
Cabinet/Countertop Cutout Dimensions without Downdraft Vent - Top View
Installed Rangetop - Side View
Gas connection and power cord may be
routed through bottom or back of chassis
Gas and electrical connections at
right rear section of chassis
Cabinet
face
Installed control
panel overhang
1/3/8” (3.5 cm)
24” (61.0 cm)
Countertop
Mounting platform
IMPORTANT: Use only the downdraft vent models specified.
Cabinet tolerances ±1/16” (±1.6 mm) unless otherwise noted.
7
Installation Requirements
NOTE: Gas and electrical connections may only be routed through
the bottom of the rangetop when installed with a downdraft vent.
Non combustible rear
wall recommended
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (1.0 cm) min.
countertop overhang
2 5/8”
(6.7 cm)
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for raised
vent, gas and electrical connections
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
11 7/16”
(29.1 cm)
C
L
D
D
E
B
C
L
C
L
C
L
26 5/8”
(67.6 cm)
min.
cabinet
depth
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
15”
(38.1 cm)
Cabinet/Countertop Cutout Dimensions with Downdraft vent - Top View
Cabinet/Countertop with Downdraft vent - Side View
Stiffener
Cabinet face
Control panel
overhang
1 3/8” (3.5 cm)
Countertop
Dacor approved
downdraft vent
IMPORTANT: See downdraft
installation instructions for
duct system layout/planning
DYRTP366 or
DYRTP486 rangetop
3/8” min. (1.0 cm)
space behind
downdraft vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Minimum
countertop
height:
30 1/4"
(76.8 cm)
HRTP366, HRTP486
8
Installation Instructions
Unpack the Rangetop
WARNING
If the gas and electric service provided does not
meet the product specifications, do not proceed with
the installation. Call the dealer, the gas supplier or a
licensed electrician.
The rangetop is heavy. A minimum of two people are
required to safely install it.
Unpack the parts box and verify that all required compo-
nents have been provided. If any item is missing or dam-
aged, please contact your dealer immediately. Do not install
a damaged or incomplete appliance. The customer must
report cosmetic issues within 30 days of installation.
3 Grates
8 standard burner caps (4 brass, 4 porcelain)*
4 standard burner rings
4 SimmerSear™ burner caps (2 brass, 2 porcelain)*
2 SimmerSear burner rings
2 SimmerSear burner heads
4 standard knobs
2 MAX GRIDDLE knobs
Dacor Stainless Steel Cleaner
WOK ring
Griddle
2 hold down bolts
2 washers (for hold down bolts)
Gas regulator
Product literature
*The rangetop is supplied with two different types of burner
caps (brass and porcelain) to suit the customer’s prefer-
ence.
Rangetop Installation
WARNING
To prevent damage to the gas pressure regulator,
install it only after the rangetop is mounted in its per-
manent position.
Do not over-tighten the hold down bolts. Over tight-
ening the hold down bolts may result in improper
burner operation.
IMPORTANT
Do not use a hardening compound or caulk to
permanently seal the rangetop into place. The rangetop
must be readily removable if service is required. Removal
of sealant to service the unit will be performed at the
customer’s expense.
1. Lower the rangetop into the cutout while feeding the
electrical cord into the utility cutout. Center the ran-
getop in the cutout.
2. Secure the rangetop to the countertop using the two
(2) provided hold-down bolts and washers provided. Do
not overtighten the bolts.
9
Installation Instructions
Gas Line Connection
WARNING
Verify that the gas supply meets specifications before connection. See page 3.
The maximum gas supply pressure to the regulator must never exceed 1/2 pounds per square inch (psi) or 3.5 kPa.
Do not install or use the rangetop without the included gas regulator installed.
Ensure that the arrow on the regulator points in the direction of the gas flow, towards the rangetop.
Do not apply excessive pressure when tightening gas connections and fittings.
Do not use Teflon tape or plumber’s putty on flexible gas line connections.
Test the gas lines for leaks as instructed before use. Do not use a flame to check for leaks.
The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the
specified manifold pressure. See page 3.
The rangetop and shut-off valve must be disconnected from the gas supply piping system during any pressure test-
ing exceeding 1/2 psi (3.5 kPa).
The rangetop must be isolated from the gas supply piping system by closing the shut-off valve to the rangetop dur-
ing any gas supply piping system pressure testing equal to or less than 1/2 psi (3.5 kPa).
For LP gas installations, the LP gas tank must have its own high-pressure regulator in addition to the pressure regu-
lator supplied with the rangetop.
IMPORTANT
Within the Commonwealth of Massachusetts, this appliance must be installed by a licensed plumber or gas fitter.
1. Attach the gas pressure regulator (included with the
rangetop) to the 3/4” (1.9 cm) male NPT gas inlet on
the rangetop. The inlet is located on the bottom, at the
right rear portion of the chassis. For tight installations,
the regulator may be installed upstream from the pipe
nipple, anywhere between the shut-off valve and the
rangetop. For best performance, minimize gas pressure
loss by attaching the regulator as close as possible to
the rangetop gas inlet.
2. Complete connection of the gas supply to the ran-
getop by installing a minimum 1/2” flexible gas line (not
included) between the pressure regulator and the shut-
off valve.
3. Check for gas leaks:
◊ Turn all rangetop control valves to the OFF posi-
tion.
◊ Turn on the gas supply valve and check all lines
and connections for leaks using a soap and water
solution or a gas leak detector.
◊ Turn the gas supply valve off.
10
Installation Instructions
SimmerSear Burner Assembly Standard Burner Assembly
Spill tray
Standard
burner
SimmerSear
burner
Burner cap
Burner cap
Burner ring
Burner ring
Burner head
Burner base
Burner base
Keyed hole
Ridge on bottom
of burner cap
Ridge on bottom
of burner cap
Burner Component Installation
WARNING
Never attempt to operate the rangetop with any of the
burner parts removed.
Do not attempt to adjust the burner air mixture set-
tings. All adjustments are preset at the factory.
Remove the burner parts and grates from their shipping
packages.
Install the burners as shown. Either type (color) of the
supplied burner caps may be used. When installing the
burner components, twist each piece back and forth
slightly until it drops completely into place. The burners
will not operate properly unless all of the burner pieces
are properly seated.
Gently set the grates on top of the spill tray. Make sure
that the rubber feet are positioned in the dimples.
STEP 1: Install
burner head.
Put locating
tap into keyed
hole.
STEP 1: Put
burner ring on
top of the head.
STEP 3: Install
burner cap.
Ridge on cap
must surround
top of ring.
STEP 3: Install
burner cap. Ridge
on cap must sur-
round top of ring.
STEP 2: Install
burner ring. Line
up ring tabs
with head slots.
Twist back and
forth to assure
proper seating.
STEP 2: Turn
ring until it drops
into place. Twist
back and forth
to assure proper
seating.
11
Installation Instructions
Burner Knob Installation
CAUTION
Installing the rangetop knobs in the wrong position may
result in damage to the rangetop griddle. The knobs for
the center burners are marked with the maximum griddle
settings.
There are two (2) different types of knobs supplied with the
rangetop. The knobs for the center burners have the words
MAX GRIDDLE on them.
If not already installed, put the knobs with the words
MAX GRIDDLE on them onto the inner (center burner)
valve shafts.
Put the remaining knobs on the outer valve shafts .
When installing the knobs, align the “D-shaped” open-
ing on the back of the knob with the end of the valve
shaft. Carefully push the knob on until it stops.
Icons on outer burner knobs
Icons on outer burner knobs
Icons on center burner knobs
12
Verifying Proper Operation
WARNING
Make sure that power to the electrical outlet is turned
off at the circuit breaker or fuse box and that the gas
is turned off at the gas supply valve before proceed-
ing.
The rangetop must be properly grounded at all times
when electrical power is applied.
Prior to operating the rangetop, read the accompanying use
and care manual carefully.
1. Make sure all the
rangetop burner con-
trols are in the OFF
position.
2. Connect the power
cord to the electrical outlet.
3. Turn on power to the electrical outlet at the circuit
breaker panel or fuse box.
4. Gently push in and turn one of the burner control knobs
counterclockwise to the HIGH position. Verify that the
associated burner igniter sparks, then return the knob
to the OFF position. Repeat for all of the remaining
burner knobs.
5. Turn on the gas supply valve.
6. Perform the following ignition test for all of the burners,
one at a time:
Push in and turn one of the control knobs counter-
clockwise to the HIGH position. Only the igniter for
the selected burner will spark. It may take up to four
seconds for the gas to ignite, at which time the ignit-
er will stop sparking. If ignition does not occur within
four seconds, turn the knob to the OFF position, wait
for at least five minutes to allow any gas to dissipate,
then repeat the test.
Once the burner lights, the control knob can be rotat-
ed counterclockwise from HIGH to LOW to adjust the
flame height progressively.
When the unit is installed properly, the flame will be
steady. It will also have
a sharp, blue inner cone
that will vary in length
proportional to the
burner size. The flame
will be reduced by the
Smart Flame™ feature
under the grate fingers
to increase grate life.
NOTE: If the rangetop does not operate properly, follow
these troubleshooting steps:
Verify that power and gas are supplied to the rangetop.
Check to make sure that the power plug is connected
to the electrical outlet and that power is turned on at
the circuit breaker panel or fuse box.
Check to make sure that all burner parts are properly
seated.
If the burner continues to spark after ignition without
stopping, have a licensed electrician check the electri-
cal outlet for proper grounding or reversed polarity.
Repeat the burner ignition test.
If the appliance still does not work, contact Dacor
Distinctive Service at (800) 793-0093 ex 2822. Do not
attempt to repair the appliance yourself. Be sure to have
the model and serial numbers available when you call. See
the inside cover for location.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
Removing the Rangetop for
Repair
To remove the appliance for repair, perform the installation
process on the previous pages in reverse order.
Normal Flame
Appearance
Installation Instructions
OFF HIGH LOW
13
Installation Instructions
Installation Checklist
WARNING
To ensure a safe and proper installation, the follow-
ing checklist should be completed by the installer to
ensure that no part of the installation has been over-
looked.
Proper installation is the responsibility of the home-
owner. The importance of proper installation of your
Dacor rangetop cannot be overemphasized.
Is the electrical outlet for the rangetop grounded and
located according to these instructions and in accor-
dance with all applicable electrical codes? See pages
3 and 4.
Is the gas service for the rangetop located and installed
according to these instructions and in accordance with
all applicable codes? See pages 3 and 4.
Has the gas supply inlet pressure been measured to
ensure that it does not exceed the maximums stated in
these instructions? See page 3.
Is the rangetop secured using the provided hold-down
bolts and washers? See page 8.
Is the rangetop connected to the gas supply according
to these instructions and in accordance with all appli-
cable codes? Did the installer check the gas supply for
leaks? See page 9.
Are all burner parts and grates properly installed
according to these instructions? See page 10.
Are the knobs installed in the proper positions? See
page 11.
Has proper operation been verified?
Has the warranty been activated on-line or the warranty
card filled out completely and mailed?
14
Wiring Diagram
AFTER SERVICING
VERIFY PROPER OPERATION
120V, 60Hz, 0.25A
POWER SUPPLY
CAUSE IMPROPER AND DANGEROUS OPERATION.
WHEN SERVICING CONTROLS. WIRING ERRORS CAN
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION
WIRING DIAGRAM
DYRTP366/DYRTP486
RR LED HARNESS
O
O
O
O
O
O
B
B
B
B
B
B
B
B
RL BURNER
IGNITOR, IGNITOR,
RC BURNER
RR BURNER
IGNITOR,
IGNITOR,
FR BURNER
IGNITOR,
FL BURNER
FC BURNER
IGNITOR,
S1
S2
S3
S4
S6
S5
B
B B
B
BLACK
WHITE
FR LED HARNESS
W
W
W
W
FL LED HARNESS
Single Point
Spark Module
W
W
W
W
W
Single Point
Spark Module
Single Point
Spark Module
W
W
Single Point
Spark Module
W
W
Single Point
Spark Module
FC LED HARNESS
W
W
W
W
W
RL LED HARNESS
RC LED HARNESS
W
W
Single Point
Spark Module
W
W
WIRING DIAGRAM
HRTP366, HRTP486
15
Notes
16
Notes
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Dacor HRTP486SNG Installation guide

Category
Cookers
Type
Installation guide
This manual is also suitable for

Dacor HRTP486SNG is a rangetop with advanced features designed to make cooking easier and more enjoyable. Its 48-inch width provides ample space for multiple pots and pans, while the high-powered burners deliver precise temperature control for consistent results. The rangetop also features a built-in griddle, perfect for cooking pancakes, eggs, and other breakfast favorites.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI