INSTALLATION
Fig. A: Loosen the screw on side of the light. Remove the bracket from
the canopy light by pulling it out slightly, just leaving the ring on bracket.
Depending on the mounting method continue on to the applicable
mounting steps below.
SURFACE MOUNTED WITH J-BOX
Fig. 1: Fasten the bracket to the J-Box and put the wire through the central
hole for wiring.
Fig. 2: Attach the canopy light with bracket by replacing the ring on clips
again. Connect the Black wire for line, White for neutral, Yellow/Green for
ground.
Fig. 3: Slide the canopy light into the bracket and secure the screw on
side of the light; to prevent the light from sliding out from the bracket.
Installation is complete.
PENDANT WITH 3/4 INCH CONDUIT
Fig. 4: Connect the wires threaded from conduit and the canopy light;
Black wire for line, White for neutral, Yellow/Green for ground.
Fig. 5: Screw the threaded conduit into the hole on top of the canopy light.
Installation is complete.
GENERAL WIRING GUIDE
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the luminaire.
WARNING
• To prevent personal injury or product damage only licensed electricians should install.
• To avoid electric shock or component damage disconnect power before attempting installation or servicing.
• This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety
standards.
• Disconnect product and allow cooling prior to servicing.
• Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product
malfunction.
• To prevent product malfunction and/or electrical shock this product must be properly grounded.
• This luminaire is designed to operate in ambient temperatures ranging from -40°C to 40°C and to be horizontally mounted with the LEDs facing down.
• This product is not suitable for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
!WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
Fig. A Fig. 1
Fig. 2
Fig. 4 Fig. 5
Fig. 3
Note: If fixture is not connected to a separate 0-10V dimming circuit, cap
o purple and gray wires separately. Failure to do so may cause fixture
malfunction and void warranty.
WITH 0-10V
DIMMING CIRCUIT
WITHOUT 0-10V
DIMMING CIRCUIT
Light
Fixture
Black
White
Purple
Grey
Ground
(+) Line
(-) Common
Ground
Light
Fixture
Black
White
Purple
Grey
Ground
(+) Line
(-) Common
(+) DIM V+
(-) DIM V-