Obtain the permission of your mains gas supplier
and ue gas inspector prior to the installation of Wolf
gas red boilers [where appropriate].
Wolfgasred boilers must only be installed by a re-
cognised heating contractor. This heating contractor
willalsoberesponsiblefortheproperinstallationand
commissioningoftheheatingsystem.
Thefollowingregulations,rulesandguidelinesmustbe
observedduringinstallation:
- DIN EN 12828
Heating systems in buildings, designing hot water
heatingsystems
- VDE0722/EN50165
Electrical equipment of heat generators with non-
electricalheatingsystems.
- EN 60335-1
Safetyofelectricalequipmentfordomesticuseand
similarpurposes
- VDE0470/EN60529
Protectionthroughhousings
Standards and regulations
Note: Please read these instructions carefully
before the installation and keep them in a
safe place. Please also note the technical
information in the appendix.
Any damage or loss resulting from technical
modications to the control unit or to the
control components are excluded from our
liability.
Incorrect use can lead to a risk to life and
limb or to a risk of material losses.
Requirements
Theinstallationoftheboilermustbeinaccordancewith
therelevantrequirementsofGasSafety(Installationand
Use)Regulations1998,HealthandSafetyDocument
No.635(TheElectricityatWorkRegulations1989),BS
7671(IEEWiringRegulations)and the Water Supply
(WaterFitting)Regulations1999,orTheWaterBylaws
2000(Scotland).Itshouldalsobeinaccordancewith
therelevantrequirementsoftheLocalAuthority,Building
Regulations, including amendments to the Approved
DocumentsPartLandJ2002,TheBuildingRegulations
(Scotland),TheBuildingRegulations(NorthernIreland)
andtherelevantrecommendationsofthefollowingBritish
Standards:
BS5440: Fluesandventilationofgasredboilersnot
exceeding 70 kW net:
- Part1:Flues
- Part2:Ventilation
BS5449: Specicationforforcedcirculationhotwater
fordomesticpremises.
BS5546: Specicationforgashotwatersuppliesfor
domesticpremises.
BS6700: Servicessupplyingwaterfordomesticuse
withinbuildingsandtheircurtilages.
BS6798: Specicationforinstallationofgasredboilers
notexceeding60kWinput.
BS6891: Specicationforinstallationoflowpressure
gaspipeworkupto28mm(R1")indomestic
premises(2
nd
familygas).
BS7593: Treatment of water in domestic hot water
centralheatingsystems.
InstituteofGasEngineersPublicationIGE/UP/7/1998:
"Guideforgasinstallationsintimberframedhousing".
Important: The appliance must be installed
and serviced by a competent person as
stated in the Gas Safety (Installation and Use)
Regulations 1998. In IE, the installation must
be in accordance with the current edition
of I.S,813 ´Domestic Gas Installations´, the
current Building Regulations and reference
should be made to the current ECI rules for
electrical installation.
When tightening or loosening threaded
connections always use suitable open-ended
spanners (not pipe wrench, or extensions,
etc.). Incorrect use and/or unsuitable tools
can lead to damage (e.g. gas or water
leaks)!