Agilent Technologies N2610A User manual

Category
Cable network testers
Type
User manual
Agilent Technologies
Agilent N2610A
FrameScope 350
Network Performance
Analyzer
User’s Manual
Version 3.0
Notices
© 2002 Agilent Technologies, Inc.
No part of this manual may be reproduced
in any form or by any means (including
electronic storage and retrieval or transla-
tion into a foreign language) without prior
agreement and written consent from Agi-
lent Technologies, Inc. as governed by
United States and international copyright
laws.
Manual Part Number
N2610-90000
Edition
First edition, July 2002
Agilent Technologies, Inc.
90 Central Street
Boxborough, MA 01719 USA
Warranty
The material contained in this docu-
ment is provided “as is,” and is sub-
ject to being changed without notice
in future editions. Further, to the max-
imum extent permitted by applicable
law, Agilent Technologies disclaims
all warranties of merchantability and
fitness for a particular purpose. Agi-
lent Technologies shall not be liable
for errors or for incidental or conse-
quential damages in connection with
the furnishing, use, or performance of
this document or of any of the prod-
ucts to which it pertains. Should Agi-
lent Technologies have a written
contract with the user and should any
of the contract terms conflict with
these terms the contract terms shall
control.
Technology Licenses
The hardware and/or software described in
this document are furnished under a
license and may be used or copied only in
accordance with the terms of such license.
Restricted Rights Legend
If Software is for use in the performance of
a U.S. Government prime contract or sub-
contract, Software is delivered and
licensed as “Commercial computer soft-
ware” as defined in DFAR 252.227-7014
(June 1995), or as a “commercial item” as
defined in FAR 2.101(a) or as “Restricted
computer software” as defined in FAR
52.227-19 (June 1987) or any equivalent
agency regulation or contract clause. Use,
duplication or disclosure of Software is
subject to Agilent Technologies’ standard
commercial license terms, and non-DOD
Departments and Agencies of the U.S. Gov-
ernment will receive no greater than
Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S. Govern-
ment users will receive no greater than
Limited Rights as defined in FAR 52.227-14
(June 1987) or DFAR 252.227-7015 (b)(2)
(November 1995), as applicable in any
technical data.
Safety Notices
CAUTION
A CAUTION notice denotes a haz-
ard. It calls attention to an operat-
ing procedure, practice, or the like
that, if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and
met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly per-
formed or adhered to, could result
in personal injury or death. Do not
proceed beyond a WARNING
notice until the indicated condi-
tions are fully understood and met.
Agilent FrameScope 350 User’s Manual iii
In This Guide…
This user’s guide contains information for using your
FrameScope 350 handheld network performance analyzer using
software version 3.0.2.
Note that some systems running earlier software may not
provide all of the features described in this manual; systems
running later versions of software may operate differently than
described in this manual. Be sure to refer to any user’s manual
supplements or release notes that came with the unit or call
800-452-4844.
iv Agilent FrameScope 350 User’s Manual
Agilent FrameScope 350 User’s Manual v
Contents
1 Introducing the FrameScope 350
The FrameScope 350 at a Glance 2
The DualRemote 350 at a Glance 6
The Main Menu at a Glance 7
Getting Started 10
2 Network Testing with the FrameScope 350
Network Testing Overview 16
Examining the Network 17
Running an Autotest 19
Changing the Autotest Metrics 23
Using the Stations List 24
Performing a Ping Test 28
Performing a Trace Route 31
Performing SNMP Queries 34
Viewing Statistics 37
Generating Network Traffic 40
Performing a MAC Loopback 43
Locating a Hub Port with Blink Port 45
Viewing the Error Log 47
Using the Test Database 49
Using the Network Database 50
Locating Switch Ports 52
3 Cable Testing with the FrameScope 350
Cable Testing Overview 57
Calibrating the Tester 61
Setting Up an Autotest 62
Running an Autotest 78
Saving Test Results 79
Viewing Result Details 82
Using Talksets 87
vi Agilent FrameScope 350 User’s Manual
Using CompactFlash™ Cards 88
Printing Labels 90
4Fiber Testing
Fiber Testing Overview 94
Calibrating the Tester 96
Setting Up an Autotest 101
Running an Autotest 114
5 Cable Testing in Expert Mode
Testing Overview 117
Changing to Expert Mode 118
The Expert Autotest Setup 119
The Expert Tools Menu 134
Running COAX and TWINAX Autotests 142
6 Expert Fiber Testing
About Fiber Expert Mode 146
Changing to Expert Mode 147
Viewing Probe Information 148
The Fiber Tools Menu 150
7 System Operations
The Status Display Area 156
The System Menu 157
System Information 158
Storage Setup 159
Battery Status 160
Time and Date Setup 161
User Interface Setup 162
Operator Setup 163
Touchscreen Calibration 164
Serial Baud Rate Setup 165
Restore Default Settings 166
Calibration Information 168
Agilent FrameScope 350 User’s Manual vii
Printer Setup 169
Network Settings 170
Remote Control 173
SNMP Settings 174
Demo Mode 175
8 Network Performance Analyzer Reference
Network Connection 179
Network Database 181
Network Performance Autotest 184
Statistics 202
Network Tools 205
Remote Control 209
Memory Requirements 210
9 Cable Tester Reference
Measurements 212
Calibration 216
Memory Requirements 218
10 DualRemote 350 Reference
The DualRemote 350 220
11 Specifications
Physical 224
Environmental 225
Electrical 226
Ports 227
Display 229
Fiber SmartProbe+ 230
12 Glossary
Glossary 232
viii Agilent FrameScope 350 User’s Manual
1
Agilent Technologies
Agilent N2610A FrameScope 350 Network Performance Analyzer
User’s Manual
1
Introducing the FrameScope 350
The FrameScope 350 at a Glance 2
Front View 2
Side Views 3
Controls 4
Ports 4
The DualRemote 350 at a Glance 6
The Main Menu at a Glance 7
The Network Tab 8
The Cable Tab 9
Getting Started 10
Switching the FrameScope On and Off 10
Checking Power and Charging the Battery 11
Connecting to the Network 12
Using the FrameScope 350 13
Running a Test 13
The Agilent FrameScope 350 Network Performance Analyzer is
a powerful handheld instrument that measures the
performance of your key network resources and verifies the
cabling and active network equipment. The FrameScope 350
integrates network performance analyzer features such as auto
discovery, performance autotesting, and fault finding; with
versatile cable certification testing for Category 6 (Class E) and
category 5E (Class D).
2 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
The FrameScope 350 at a Glance
The FrameScope 350 at a Glance
Front View
Figure 1 FrameScope 350 Front View
SmartProbe port (top)
Strap cleat
Color touch screen
Power button
CompactFlash™ memory
card slot (bottom)
OK button
Scroll button
Introducing the FrameScope 350 1
The FrameScope 350 at a Glance
Agilent FrameScope 350 User’s Manual 3
Side Views
Figure 2 Left Side
Figure 3 Right Side
Stylus clip
USB ports
DC Power input
Battery pack (back)
Headset port
Serial port
Flip-out stand (back)
4 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
The FrameScope 350 at a Glance
Controls
Color Touch Screen The FrameScope 350’s touch screen is the
main user interface. Test controls and results are shown here.
Simply press the screen with your finger or a stylus to navigate
through the menus and test controls.
Power Button Press the Power button briefly to switch the unit
on. To switch the unit off, do one of the following:
Press Power twice.
Press Power once, wait 5 seconds and the unit powers off.
Press Power once and hit the Off button on the screen.
OK Button Press the OK button to activate the currently
selected item on the display. Use the OK button to confirm
edits, enter values, and execute selected features.
Scroll Button The scroll rocker button moves the highlight
cursor on the screen. Use this button to scroll through selected
items on the display.
Ports
SmartProbe Port The SmartProbe test port on the top of the
FrameScope provides the network test interface. This port
accepts any of the Agilent SmartProbes such as:
Channel SmartProbe for testing twisted pair using patch
cords.
Link SmartProbe for testing twisted pair at network outlets.
Fiber SmartProbe for testing optical fiber.
CompactFlash™ Slot This port on the bottom of the unit
accepts standard CompactFlash™ cards for data storage.
USB Ports The FrameScope provides two universal serial bus
(USB) interface ports to connect with PCs and peripherals. The
unit provides a USB Type A (Host) port and a USB Type B
(Hub) port. See “USB-A porton page 227.
Serial Port The Serial port provides an 8-pin RS-232 interface
for connecting a PC. See “Serial port” on page 227.
Introducing the FrameScope 350 1
The FrameScope 350 at a Glance
Agilent FrameScope 350 User’s Manual 5
Talkset Port This port allows you to connect Agilent’s
FrameScope talkset (N2605A-137) for two-way voice
communication between the FrameScope and DualRemote over
copper cabling.
DC Power Input The DC power input accepts any of the Agilent
12 Vdc power adapter/chargers.
CAUTION
Use only the 12 Vdc adapter/charger supplied with your
FrameScope 350. Using an incompatible adapter/charger can
damage your FrameScope equipment.
6 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
The DualRemote 350 at a Glance
The DualRemote 350 at a Glance
Figure 4 DualRemote Front View
The Agilent DualRemote 350 is used with the FrameScope 350
when performing cable testing. The DualRemote is positioned at
the far end of the cabling run being tested. This unit is
controlled by the FrameScope, and shows the results of the
cable tests.
Figure 4 shows the indicators and controls of the DualRemote.
For complete information on the DualRemote, see Chapter 10,
“DualRemote 350 Reference”.
Pair status indicators
W
arning indicators
T
est progress and Result
indicators
Fault location indicators
Diagnostic indicators
Power indicator
Power button
OK button
Scroll button
Introducing the FrameScope 350 1
The Main Menu at a Glance
Agilent FrameScope 350 User’s Manual 7
The Main Menu at a Glance
Figure 5 The Main Menu
Title Bar Displays the name of the current screen.
Tab Area Display the currently selected tab. The
FrameScope 350 provides two tabs: Network and Cable. Select a
tab to choose the type of testing you want to do.
Status Display Area This area displays the time of day, network
connection status, battery status, storage status, and talkset
activity.
Navigation Buttons These buttons move through the interface
screens:
•Back returns to the previous screen.
•Main Menu returns to the Main Menu.
•Help launches the built-in help.
Title bar
Tab area
Status display area
Navigation buttons
8 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
The Main Menu at a Glance
The Network Tab
Figure 6 FrameScope Network Tab
Tab Title Displays the name of the tab.
Network Resource Area Shows all of the detected network
resources. When you press the Network tab, the FrameScope
performs auto discovery of network resources. Resource icons
shown with a black triangle (see below) can be pressed to
display more information.
Error Flag Displayed when an unacknowledged error is in error
log
Utilization Graph Displays current network usage. Press this
graph to display more statistics.
System Menu Button Calls the System menu.
Tools Menu Button Calls the Tools menu.
Tab title
Network resources area
Error Flag
Utilization graph
System menu button
Tools menu button
Autotest button
Press icon to view details
Introducing the FrameScope 350 1
The Main Menu at a Glance
Agilent FrameScope 350 User’s Manual 9
Autotest Button Calls the Network Autotest Setup screen.
The Cable Tab
Figure 7 FrameScope Cable Tab (normal mode)
Tab Title Displays the name of the tab.
Certification Test Buttons Launch a certification autotest. For
example, Category 5E or Category 6 cable certification.
Setup Menu Button Opens the Setup menu.
Calibration Button Opens the Calibration screen for calibrating
the FrameScope 350 with the Dual Remote 350.
System Menu Button Opens the System menu.
Tab title
Certification test buttons
Setup menu button
Calibration button
System menu button
NOTE
The Cable tab will look different if Expert Mode is turned on.
10 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
Getting Started
Getting Started
Switching the FrameScope On and Off
1 To switch the FrameScope on, briefly press the Power button
on the front panel.
The screen will light and a brief tone will sound.
2 While the unit is on, briefly pressing the Power button will
call the Sleep/Shutdown window.
Press Sleep to put the unit in sleep mode. When the
FrameScope is in sleep mode, briefly press the Power
button or press the screen to reactivate it.
Press Off or wait five seconds to turn the unit off.
Press Cancel to go back to the Main Menu.
3 You can also turn the unit off by pressing the Power button
twice.
Introducing the FrameScope 350 1
Getting Started
Agilent FrameScope 350 User’s Manual 11
Checking Power and Charging the Battery
The FrameScope’s battery should provide enough power for a
typical day of testing. The AC power adapter/charger can also
be used to power the unit and to recharge the battery.
To check the battery’s charge level, perform these steps:
1 Switch on the FrameScope, if necessary, by pressing the
Power button on the front of the unit.
2 Observe the battery icon in the Status display area on the
Main Menu.
The battery icon will show how much charge remains in the
battery (for example, 45%).
If the battery is severely depleted, a low-battery message will
be displayed.
3 To recharge the battery or to power the FrameScope from an
AC power source, plug the DC power connector on the
adapter/charger into the 12 Vdc connector on the side of the
unit.
4 Observe that the AC power icon is displayed in the Status
area.
The AC icon will also indicate the battery’s charge level (for
example 72%).
12 Agilent FrameScope 350 User’s Manual
1 Introducing the FrameScope 350
Getting Started
Connecting to the Network
The FrameScope 350 uses test probes to connect to the network
you are testing. Follow these steps to connect your unit to the
network:
1 Select an appropriate Agilent test probe for your application:
Select a Channel SmartProbe for testing twisted pair
using patch cords.
Select a Link SmartProbe for testing twisted pair at
network outlets.
See also “Cable Testing Overviewon page 57.
2 Plug the test probe into the SmartProbe port on the top of
the FrameScope.
3 Connect the cabling to the SmartProbe. If you are performing
optical cable testing, connect both the input and output
signals. If you are performing optical network testing,
connect an optical-to-copper media converter to the
SmartProbe.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248

Agilent Technologies N2610A User manual

Category
Cable network testers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI