Crown 137769-3 User manual

Category
Supplementary music equipment
Type
User manual

This manual is also suitable for

Operation Manual
Obtaining Other Language Versions:
To obtain information in another language about the use of this product, please contact your
local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situation which may arise during installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have
occurred. To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.
Trademark Notice:
Crown, Crown Audio, IQ, IQ System, and Amcron are registered trademarks of Crown International. DBC, IQwic
and TCP/IQ are trademarks of Crown International. Other trademarks are the property of their respective owners.
Some models may be exported under the name Amcron.
®
©2008 by Crown Audio
®
Inc., 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000
DBC Network Bridge
137769-3
2/08
Operation Manual
DBC Network Bridge
page 2
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings. Install
in accordance with the manufacturer’s instruc-
tions.
8) Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce
heat.
9) Do not defeat the safety purpose of the polar-
ized or grounding-type plug. A polarized plug
has two blades with one wider than the other.
A grounding-type plug has two blades and a
third grounding prong. The wide blade or the
third prong is provided for your safety. If the
provided plug does not fit into your outlet,
consult an electrician for replacement of the
obsolete outlet.
10) Protect the power cord from being walked on
or pinched, particularly at plugs, convenience
receptacles, and the point where they exit from
the apparatus.
11) Only use attachments/accessories specified
by the manufacturer.
12) Use only with a cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use
caution when moving the cart/apparatus com-
bination to avoid injury from tip-over.
13) Unplug this apparatus during lightning storms
or when unused for long periods of time.
14) Refer all servicing to qualified service person-
nel. Servicing is required when the apparatus
has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally,
or has been dropped.
15) WARNING: TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPARATUS TO RAIN OR MOISTURE.
16) DO NOT EXPOSE TO DRIPPING OR SPLASH-
ING. DO NOT PLACE OBJECTS FILLED WITH
LIQUID, SUCH AS VASES,ON THIS APPARA-
TUS.
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE
TOP OR BOTTOM COVERS. NO USER SERVICE-
ABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ
PAS LES COUVERCLES. IL N’Y A PAS DES PAR-
TIES SERVICEABLE À L’INTÉRIEUR. TOUS REPA-
RATIONS DOIT ETRE FAIRE PAR PERSONNEL
QUALIFIÉ SEULMENT.
TO COMPLETELY DISCONNECT THIS EQUIPMENT
FROM THE AC MAINS, DISCONNECT THE POWER
SUPPLY CORD PLUG FROM THE AC RECEPTA-
CLE. THE MAINS PLUG OF THE POWER SUPPLY
CORD SHALL REMAIN READILY OPERABLE.
WATCH FOR THESE SYMBOLS:
The lightning bolt triangle is used to alert the user
to the risk of electric shock.
The exclamation point triangle is used to alert the
user to important operating or maintenance instruc-
tions.
Important Safety Instructions
FCC COMPLIANCE NOTICE
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or televi-
sion reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
DBC Network Bridge
Operation Manual page 3
DECLARATION of CONFORMITY
Crown International, Inc.
Sue Whitfield
574-294-8289
European Representative's Name and Address:
Nick Owen
35, Bassets Field
Thornhill
Cardiff. South Glamorgen
CF14 9UG United Kingdom
Equipment Type: Digital B-Chain
Family Name: IQ System Component
Model Names: DBC Network Bridge
EMC Standards:
EN 55103-1:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions
EN 55103-1:1997 Magnetic Field Emissions-Annex A @ 10 cm
EN 61000-3-2:2001 Limits for Harmonic Current Emissions (equipment input current less than or equal to 16 A per phase)
EN 61000-3-3:2002 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current less than or equal to16A
EN 55022:2003 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class A
EN 55103-2:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity
EN 61000-4-2:2001 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)
EN 61000-4-3:2001 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A)
EN 61000-4-4:2001 Electrical Fast Transient/Burst Immunity (Criteria B)
EN 61000-4-5:2001 Surge Immunity (Criteria B)
EN 61000-4-6:2003 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)
EN 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variation
Safety Standard:
IEC 60065: 2002 7th Ed. Safety Requirements - Audio Video and Similar Electronic Apparatus
I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.
Signed
Title: Senior Vice President of Manufacturing
Date of Issue: Dec. 1, 2004
ISSUED BY: Crown International, Inc.
1718 W. Mishawaka Road
Elkhart, Indiana 46517 U.S.A.
Due to line current harmonics, we recommend that you contact your supply authority before connection.
Larry Coburn
FOR COMPLIANCE QUESTIONS ONLY:
Operation Manual
DBC Network Bridge
page 4
1 Getting Started With the DBC Network Bridge
Welcome! This Quick-start guide will get you up and running
in a short time. Then please refer to the rest of the manual for
details on the DBC™ Network Bridge and its operation.
IMPORTANT: Unplug power cord from AC outlet
before wiring.
1.1 Hardware Installation
You will need:
Crown power amplifiers with USP3-CN PIP modules
installed, or Crown I-Tech CobraNet- version power
amplifiers
A computer running IQwic software
A 100Mb network switch
An Ethernet cable (RJ45 connector on each end) for
use between the computer and network switch
Two Ethernet cables for use between the DBC Network
Bridge and the network switch. One cable is sufficient,
but two allow redundancy.
An Ethernet cable between the network switch and
each USP3-CN module (or Ethernet connector)
installed in a Crown power amplifier.
1.1.1 Audio and Network Connections
Please refer to Figures 1.1 and 1.2.
1. Mount the DBC Network Bridge in a standard 19-inch
(48.3-cm) equipment rack or cabinet.
2. Turn off all equipment that will connect to the unit.
3. Connect the AES/EBU digital output signal from your cin-
ema processor, media player, or feature server to the analog
DB25 connector on the back of the DBC Bridge. DB25 wiring
is shown in Table 1 on the next page. Alternatively, connect
the analog output signal from your cinema processor to the
Analog DB25 connector on the back of the DBC Bridge.
DB25 wiring is shown in Table 2 on the next page.
4. See Figure 1.2. Connect any auxiliary mic or line signals
to the female XLR Auxiliary Inputs on the back of the DBC
Network Bridge. Set the MLP switch for Mic, Line, or Phan-
tom-powered mic. Adjust gain potentiometers to optimize
gain structure.
Figure 1.1 System Wiring
  !
! !
! !

$"#.%47/2+
!%3$)')4!,!5$)/
!.!,/'!5$)/
%4(%2.%4
30%!+%2,).%
1
1
Powe r
2 3 4 5 6 7 8 9 10 1112
234
9101112
5678
13 14 15 16
NETGEAR
$"##ONTROL0#
#4SW)10)0530#.
#4SW)10)0530#.
#4SW)10)0530#.#4SW)10)0530#.#4SW)10)0530#.
%THERNET3WITCH
%THERNET3WITCH
$"#"RIDGE
$"#)NPUT/PTIONS
$OLBY#0 DTS8$
DTS8$0
!%3!%3
!NALOG
!NALOG
!NALOG
3URROUND#HANNELS
3CREEN#HANNELSAND3UBWOOFERS
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
1
1
Powe r
2 3 4 5 6 7 8 9 10 1112
234
9101112
5678
13 14 15 16
NETGEAR
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Figure 1.2 Audio Inputs on the Back Panel of the DBC Bridge
XLR connector wiring:
pin 1: shield
pin 2: signal hot
pin 3: signal cold
DBC Network Bridge
Operation Manual page 5
Tabl e 1
Tabl e 2
Getting Started With the DBC Network Bridge
13
25
1
14
13
25
1
14
DBC DB25F DIGITAL AES/EBU PINOUTS
DBC DB25F ANALOG PINOUTS
PIN FUNCTION PIN FUNCTION
1 N/C 14 GND
2 N/C 15 AES1 (L/R)–
3 N/C 16 AES3 (Ls/Rs)–
4N/C 17N/C
5 N/C 18 GND
6N/C 19N/C
7 AES1 (L/R)+ 20 N/C
8 AES3 (Ls/Rs)+ 21 AES4 (Bsl/Bsr)–
9 GND 22 AES4 (Bsl/Bsr)+
10 N/C 23 AES2 (C/SW)–
11 GND 24 AES2 (C/SW)+
12 N/C 25 GND
13 N/C
PIN FUNCTION PIN FUNCTION
1 GND 14 L–
2L+ 15GND
3 BSL– 16 BSL+
4 GND 17 C–
5C+ 18GND
6 BSR– 19 BSR+
7 GND 20 R–
8R+ 21N/C
9 GND 22 GND
10 Ls 23 Ls+
11 Rs 24 Rs+
12 SW– 25 SW+
13 GND
Operation Manual
DBC Network Bridge
page 6
1.2 Communicating with the DBC Network
Bridge: TCP/IQ™ Networking
1.2.1 The Network Wizard
If you are setting up a dedicated audio network that is not part of
another network, you can use the Network Wizard to set up your
network easily.
1. Open IQwic.
2. Select Setup > Network Wizard.
3. Follow the instructions on the screen.
4. When done, skip to Step 4 on page 11.
1.2.2 Introduction
The DBC Network Bridge connects directly to Crown IQ networks
with TCP/IQ protocol. This permits extensive amp and speaker
diagnostics and control by computer. The DSP functions in the
DBC Network Bridge are controlled and monitored by a computer
running IQwic software.
The computer connects to the DBC Network Bridge on a TCP/IQ
network via a Category 5 cable plugged into the Primary Network
connector on the back of the DBC Network Bridge. The TCP/IQ
format uses off-the-shelf, fast (100 Mb) Ethernet connections.
CobraNet lets you plug in a single cable for both networking and
digital audio -- this is Crown’s Single-Click solution.
Every component in a TCP/IQ network is identified by a unique
address.
1.2.3 TCP/IQ Addressing Rules
In the next section, you will be assigning TCP/IP addresses to
the devices in your network. When you do so, be sure to follow
the addressing rules below. Otherwise, the computer may not
communicate with the devices.
Turn off DHCP (automatic addressing). This will be done in
Instruction 1C, described later.
Assign each device a static (fixed) IP address. An IP address is
made of four numbers separated by periods. Each number can be
zero to 255. The last number can never be a zero or 255. For
example, 126.126.17.1 could be an IP address. 126.126.17.0
would not be a valid IP address.
Make sure that the computer and all the devices have the same
NETWORK IDs in their addresses. This tells the computer that all
those devices are on the same network. Various tools are avail-
able to determine whether devices are on the same network. In
TCP/IQ utility described later, if items are NOT on the same net-
work, they are highlighted in the list.
Make sure that each component has its own TCP/IP address, and
there are no duplicate addresses. The same holds true for IQ
addresses.
Assign a subnet mask. Make it the same for all devices on the
network. If the network you are assembling will interconnect with
other networks, your network is considered to be a subnet within
the larger network. Check with the network administrator to
determine the proper Subnet Mask for your subnet.
If you have a stand-alone network, set the Subnet Mask to
255.255.0.0 for all components, including the computer.
Note: Just because two components have the same subnet mask
does not mean that they are on the same network. As we said, the
subnet mask just tells what part of the TCP/IP address is the Net-
work ID.
Getting Started With the DBC Network Bridge
DBC Network Bridge
Operation Manual page 7
1.2.4 TCP/IQ Setup
This example is based on a stand-alone system using switches and routers. The screen
captures were done in Windows 2000; your exact configuration may vary. If your computer
uses a network for other applications, please check with your Information Technology
Department before making any changes. Section 1.2.5 includes a helpful worksheet for
assigning addresses.
1. Turn on your computer and the rest of the system equipment. On your computer desk-
top, select Start > Settings > Control Panel > Network Connections (Figure 1.3). Set a static
TCP/IP address and Subnet mask on the master computer. Document the address and
mask.
Figure 1.3 Selecting Settings > Control Panel
1A. Right-click on LAN Connections. Then select Internal > Properties (Figure 1.4).
Figure 1.4
Result of Clicking LAN Connections > Internal
Getting Started With the DBC Network Bridge
Operation Manual
DBC Network Bridge
page 8
1B. Once the Properties window opens (Figure 1.5), click on Internet Protocol (TCP/IP).
Figure 1.5 Internal Properties Window
1C. We recommend that you uncheck “Obtain an IP address automatically”, and check
“Use the following address.” If you decide to set an IP address manually, specify an IP
address. The IP address is four numbers between 1 and 255 separated by periods. For
example, 126.126.0.1.
Select a subnet mask. The subnet mask is four numbers between 1 and 255 separated by
periods. For example, 255.255.0.0.
1D. Click OK and close the Control Panel. At this point, some computer operating systems
will require a restart.
Figure 1.6 Internet Protocol (TCP/IP) Properties Window
Getting Started With the DBC Network Bridge
The Internet Protocol (TCP/IQ) Properties window appears (Figure 1.6). Dis-
able Virtual Private Network or other encryption settings.
See Section 1.2.5, TCP/IQ Addressing Worksheet, on the next page. Open
the supplied Excel worksheet called IQ Worksheet.XLS.
255 255 0 0
126 126 0 1
DBC Network Bridge
Operation Manual page 9
EXAMPLE OF AN IQ ADDRESSING WORKSHEET
ADDRESS IQ ADDRESS MODEL DESCRIPTION CHANNEL 1 CHANNEL 2
126.126.0.1 COMPUTER
126.126.0.2 2 I-T8000 #1 RACK ROOM LEFT CLUSTER RIGHT CLUSTER
126.126.0.3
126.126.0.4
126.126.0.5
126.126.0.6
126.126.0.7
126.126.0.8
126.126.0.9
126.126.0.10
126.126.0.11
126.126.0.12
126.126.0.13
126.126.0.14
126.126.0.15
126.126.0.16
126.126.0.17
126.126.0.18
126.126.0.19
126.126.0.20
Getting Started With the DBC Network Bridge
1.2.5 TCP/IQ Addressing Worksheet
Table 3 is an example of valid TCP/IP addresses on a stand-alone network. If the TCP/IQ
network is going to be shared with other people, check with the Network Administrator for
their addressing scheme. Without getting into all of the networking rules, the table lists
approximately 20 network addresses out of a possible 65,534 addresses on this network.
There are other addresses that are valid; these are just shown as a starting point.
• The Subnet Mask for all components, including the computer, needs to be set to
255.255.0.0.
• Each computer running IQwic software must have a subnet mask of 255.255.0.0. It also
must be assigned one of the addresses listed on the following table.
• A space has been left to the right of all the addresses. This area is for your notes, such as
the IQ address or the component type.
In the CD-ROM that came with your DBC Network Bridge is an Excel spreadsheet that you
can use to keep track of TCP/IQ addresses.
Table 3
Operation Manual
DBC Network Bridge
page 10
2. Select IQ Systems > IQwic > TCPIQ Utility (Figure 1.7). This launches the TCPIQ Utility
on the master computer.
Figure 1.7 Selecting IQ Systems > IQwic > TCPIQ Utility
2A. The master computer should discover the TCP/IQ products (Figure 1.8). If not, please
re-read Section 1.2.4 on addressing rules. Also read Chapter 6, Troubleshooting.
Figure 1.8 Example of Discovered Components
2B. Once TCP/IQ Utility has launched, select a single component and click on Set
Address. In the Set Address window (Figure 1.9), set up a TCP/IQ address—it must be
unique. Then set up the same Subnet mask for all of the components as well as the master
computer. Set the IQ address, and select Send Code.
2C. Close the software. Repeat as necessary.
Figure 1.9 Set Address Window
3. Launch the IQwic program. (Figure 1.10).
Figure 1.10 Selecting IQ Systems > IQwic
Getting Started With the DBC Network Bridge
DBC Network Bridge
Operation Manual page 11
4. The Component Discovery screen appears and displays the mes-
sage, “Searching for TCP/IQ components” (Figure 1.11).
Getting Started With the DBC Network Bridge
5. The IQwic toolbar and Workspace appear. An icon of the DBC Net-
work Bridge appears in the Workspace (Figure 1.12)
6. Double-click the DBC Network Bridge Icon. The Input-Output
window appears (Figure 1.13).
7. Click on the yellow Expand/Shrink bar at
the bottom of the Input-Output window.
Figure 1.12 The IQwic Toolbar (Top)
and Workspace (Bottom)
Figure 1.13 The
Input-Output
Window
Figure 1.11 The Discovery Screen
Operation Manual
DBC Network Bridge
page 12
If there are problems, please re-read Section 1.2.3 on
addressing rules. Also read Chapter 6, Troubleshooting.
8. The processing functions appear. Click on the Unit
Presets tab at the top. The Unit Presets window appears
(Figure 1.14).
9. At the bottom right, select Preset 32, Standard Cinema.
Then select Recall this Preset. Your system is running
and ready to configure. Please continue reading the man-
ual.
Figure 1.14 The Unit Presets Window
Getting Started With the DBC Network Bridge
DBC Network Bridge
Operation Manual page 13
Important Safety Instructions ........................................................... 2
Declaration of Conformity................................................................. 3
1 Getting Started with the DBC Network Bridge .................... 4
1.1 Hardware Installation............................................................ 4
1.1.1 Audio and Network Connections.................................. 4
1.2 Communicating with the DBC Network Bridge...................... 6
1.2.1 The Network Wizard..................................................... 6
1.2.2 Introduction ................................................................. 6
1.2.3 TCP/IQ Addressing Rules ............................................ 6
1.2.4 TCP/IQ Setup............................................................... 7
1.2.5 TCP/IQ Addressing Worksheet..................................... 9
Table of Contents.............................................................................. 13
2 Welcome ....................................................... 14
2.1 Features ............................................................................... 14
2.2 How to Use This Manual....................................................... 14
Sample Application Diagram ............................................................ 15
3 Setup ............................................................ 16
3.1 Unpack and Install Your DBC Network Bridge ..................... 16
3.2 Connecting to AC Mains ...................................................... 16
3.3 Wiring................................................................................... 17
3.3.1 Analog, Digital and Auxiliary Inputs............................. 17
3.3.2 Balanced Input Wiring ................................................. 18
3.3.3 Unbalanced Input Wiring ............................................. 18
3.3.4 Balanced Monitor Output Wiring ................................. 18
3.3.5 Unbalanced Monitor Output Wiring .............................19
3.3.6 CobraNet Connections.................................................19
3.3.7 Control Port Connections ............................................19
4 Operation ....................................................... 20
4.1 Front Panel Controls and Indicators......................................20
4.2 Back Panel Controls and Connectors ...................................21
4.3 Navigating the LCD Control Screen ......................................22
4.3.1 Functions, Controls and Screens................................. 22
4.3.2 Operation Examples..................................................... 23
4.3.3 Menu Tree....................................................................23
4.4 IQwic Overview ....................................................................24
4.5 Metering ...............................................................................25
4.6 General Tab...........................................................................26
4.7 Basic Processing Functions..................................................27
4.7.1 Signal Path Tab, Cinema Surround Form..................... 27
4.7.2 Input Compressor........................................................28
4.7.3 Input Delay................................................................... 29
4.7.4 EQ Filters ....................................................................30
4.7.5 All Outputs Volume Controls .......................................32
4.7.6 Signal Generator..........................................................33
4.7.7 CobraNet: Explanation .................................................34
4.7.8 Cobranet: Output..........................................................35
4.7.9 Booth Monitor Source Select.......................................36
4.7.10 Presets.......................................................................37
4.7.11 Preset Editor ..............................................................38
Table of Contents
4.7.12 Scenes........................................................................39
4.7.13 Scene Editor...............................................................40
4.7.14 Events Scheduler........................................................41
4.8 General Firmware Features....................................................43
4.8.1 Input Level Meters........................................................43
4.8.2 Input Dynamic Cut/Boost Meters..................................43
4.8.3 Output Level Meters .....................................................43
4.8.4 Output Dynamic Cut/Boost Meters...............................43
4.8.5 Memory Backup ...........................................................43
4.8.6 Presets .........................................................................43
4.8.7 Real Time Clock ...........................................................43
4.8.8 Events...........................................................................43
5 Advanced Operation ........................................... 44
5.1 Advanced Operation Table of Contents ..................................44
5.2 Advanced Functions..............................................................45
5.3 Advanced Form Firmware Features........................................54
5.4 Technical Description ............................................................69
6 Troubleshooting ................................................ 70
7 Specifications .................................................. 73
8 Appendix A: TCP/IQ Network Basics......................... 75
9 Service........................................................... 80
10 Warranty ....................................................... 81
Crown Audio Factory Service Information Form ............83
Operation Manual
DBC Network Bridge
page 14
2 Welcome
At the heart of a Digital B Chain system, the
Crown
®
DBC Network Bridge allows you to
distribute multiple channels of digital audio
over standard fast Ethernet hardware and
cabling for use in traditional, e-cinema and d-
cinema applications.
The DBC Bridge accepts standard analog and/
or AES digital audio and CobraNet
®
digital
channels from other Cinema processors
(Dolby
®
, DTS
®
), Cinema Servers, or Alterna-
tive Content Media Players; and bridges
(routes) them to a Crown DBC network. Figure
2.1 is a sample application drawing.
This network is Crown’s proprietary “Single-
Click” solution that provides system control,
monitoring, diagnostics, and digital audio
transport. The DBC network (fed by the DBC
Network Bridge) distributes the digital audio
and system-wide control protocol to Crown
amplifiers. The DBC Network Bridge also pro-
vides the necessary system equalization, which
is stored and recalled via a series of presets for
use in both feature film and alternative content
programming.
2.1 Features
• Accepts 8 inputs (7.1 surround) via one of
the following formats:
Analog
AES/EBU
CobraNet
• Selectable mic, mic with 24V phantom
power, or line analog XLR inputs for alternative
content
• Primary and Secondary 100 Mb Ethernet
“Single-Click” connection for DBC network
• Front-panel LCD display and control func-
tions of internal presets and system setup
• Full 32-channel CobraNet digital audio
transmit/receive capability
• Enhanced matrix mixer capable of full 8x32
crosspoint matrix mixing
• 24-bit/48 kHz converters
• Studio-grade DSP with multiple filter banks
for each channel (up to 256 filters)
• 32 presets, 32 scenes, and 32 events can be
stored, labeled, and recalled
• Analog monitoring of cinema processor
inputs, pre-amp, or post-amp signals
• Multiple-function control port for third-party
automation/control
• Internal clock/calendar for scheduling events
• Auto-leveling functions for dynamic volume
control of auditoriums or lobby
• Ambient-leveling functions for maintaining
maximum signal-to-noise ratio
• Three-year, no-fault, fully transferable war-
ranty
2.2 How to Use This Manual
This manual provides you with the necessary
information to safely and correctly setup and
operate your DBC Network Bridge. It does not
cover every aspect of installation, setup or
operation that might occur under every condi-
tion. For additional information, please consult
Crown’s DBC Bridge Application Guide (avail-
able online at www.crownaudio.com), Crown
Technical Support, your system installer or
retailer.
We strongly recommend you read all instruc-
tions, warnings and cautions contained in this
manual. Also, for your protection, please send
in your warranty registration card today. And
save your bill of sale — it’s your official proof
of purchase.
DBC Network Bridge
Operation Manual page 15
  !
! !
! !

$"#.%47/2+
!%3$)')4!,!5$)/
!.!,/'!5$)/
%4(%2.%4
30%!+%2,).%
1
1
Powe r
23456789101112
234
9101112
5678
13 14 15 16
NETGEAR
$"##ONTROL0#
#4SW)10)0530#.
#4SW)10)0530#.
#4SW)10)0530#.#4SW)10)0530#.#4SW)10)0530#.
%THERNET3WITCH
%THERNET3WITCH
$"#"RIDGE
$"#)NPUT/PTIONS
$OLBY#0 DTS8$
DTS8$0
!%3!%3
!NALOG
!NALOG
!NALOG
3URROUND#HANNELS
3CREEN#HANNELSAND3UBWOOFERS
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
1
1
Powe r
2 3 4 5 6 7 8 9 10 1112
234
9101112
5678
13 14 15 16
NETGEAR
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Power
Data
Bridge
Fault
Thermal
-20
Signal
12
Ready
Clip
-10
Figure 2.1 Sample Application: Large Cinema System Diagram
Operation Manual
DBC Network Bridge
page 16
3.1 Unpack and Install Your
DBC Network Bridge
Please unpack and inspect your product for any
damage that may have occurred during transit.
If damage is found, notify the transportation
company immediately. Only you can initiate a
claim for shipping damage. Crown will be
happy to help as needed. Save the shipping
carton as evidence of damage for the shipper’s
inspection.
We also recommend that you save all packing
materials so you will have them if you ever
need to transport the unit. Never ship the
unit without the factory pack.
YOU WILL NEED (not supplied):
Input wiring cables
Network cables
Rack for mounting the DBC Network
Bridge (or a stable surface for stacking)
WARNING: Before you start to set up
your DBC Network Bridge, make sure
you read and observe the Important
Safety Instructions found at the begin-
ning of this manual.
CAUTION: Before you begin, make sure
your DBC Network Bridge is discon-
nected from the power source.
Use a standard 19-inch (48.3 cm) equipment
rack (EIA RS-310B). See Figure 3.1 for dimen-
sions.
You may also stack units without using a
cabinet.
NOTE: When transporting, units should be sup-
ported at both front and back.
3.2 Connecting to AC Mains
WARNING: The third (ground) prong of
the AC power cord connector is a
required safety feature. Do not attempt
to disable this ground connection by
using an adapter or other methods.
3 Setup
Figure 3.1 Dimensions
DBC Network Bridge
Operation Manual page 17
3.3 Wiring
Chapter 1 describes how to make connections to the DBC Network Bridge.
The information below describes the connections in detail.
3.3.1 Analog, Digital and Auxiliary Inputs
Analog Line Input: DB25 female connector accepts eight balanced ana-
log line-level analog inputs. Pinout matches Dolby CP-650 analog output.
See Table 2 on page 5.
Digital Audio Input: DB25 female connector accepts eight AES3 digital
audio signals. Pinout matches Dolby #778 AES input/output card for CP-
650. See Table 1 on page 5.
Auxiliary Inputs: Two female XLR balanced inputs for speech reinforce-
ment or announcements (see Figure 3.2).
Each input has an input selector switch.
• Slide it to the left (M) for microphone signal levels up to +7dBu
(0dBu = 0.775 volts).
• Select the center position (L) for line-level signals up to +20
dBu.
• Slide it to the right (P) to provide 24VDC to mics requiring
phantom power.
Each input has a screwdriver-set, calibrated gain control to compensate for
different input source levels. The slot on the control shaft points to the gain
setting. The settings are labeled for line-level input. Add 25 dB to the scale
if the inputs are switched for microphone level signals.
Use a screwdriver to adjust the gain pot so that the input signal level plus
gain equals roughly 0dBu. You will need to know, or estimate, the level of
the input source. Setting the source signal level to approximately 0dBu will
provide 20dBu of headroom in the input preamp. Some recommended set-
tings are given in Table 4.
3 Setup
Figure 3.2 Aux Input Level Controls, XLR connectors and
Mic/Line/Phantom Slide Switch
Pro Audio Equip-
ment
Semi-Pro or con-
sumer equipment
Dynamic mic,
speech
Condenser mic,
speech
Hot condenser
mic, speech
dBm/dBV
(nominal)
+4 dBm –10 dBV –75 dBV –65 dBV –45 dBV
dBu (nominal) +4 dBu –8 dBu –73 dBu –63 dBu –43 dBu
Suggested Setting –4 (L) +8 (L) +20 (M) +18 (P) +11 (P)
Table 4. Suggested Audio Input Gain Control Settings
0 dBm = 0.775 Vrms with a 600-ohm load.
0 dBV = 1 Vrms.
0 dBu = 0.775 Vrms.
Operation Manual
DBC Network Bridge
page 18
3.3.2 Balanced Input Wiring
Balanced sources should be wired as shown below. Notice that the
shield is not connected to the chassis ground of the source if the
source is also connected to the AC ground (that is, it has a grounded
AC plug). This prevents unwanted ground loops.
3.3.3 Unbalanced Input Wiring
Unbalanced sources should be wired as shown below. The examples are grouped
according to whether you use twin-lead shielded wire or single-lead coax (or
twisted pair).
3.3.4 Balanced Monitor Output Wiring
Balanced Monitor Output wiring is shown in Figures 3.5. Notice
that if the load is connected to AC ground, the shield should not
be connected to the output ground terminal. This will prevent
unwanted ground loops.
1. Assemble a 2-conductor shielded cable with a Phoenix-type 3-
terminal connector on one end. On the other end, solder a con-
nector that mates with your booth monitor amplifier/speaker.
2. Plug the Phoenix-type connector into the Monitor Output con-
nector on the back of the DBC Network Bridge.
3. Plug the other end of the cable into your booth monitor ampli-
fier/speaker.
12
3
2
3
1
12
3
12
3
3 Setup
12
3
12
3
12
3
12
3
Figure 3.3 Balanced Audio Input Wiring
Figure 3.4 Unbalanced Audio Input Wiring
Figure 3.5 Balanced Monitor Output Connections
+
S
+
TO MONITOR AMP/SPEAKER
DBC Network Bridge
Operation Manual page 19
3.3.5 Unbalanced Monitor Output Wiring
3 Setup
Figure 3.6 Unbalanced Monitor Output Connections
3.3.6 CobraNet Connections
The CobraNet network carries up to 32 channels of audio bidirectionally
via a single cable. Connect the DBC Network Bridge to the CobraNet net-
work using RJ45-terminated standard CAT 5 cable from the PRIMARY con-
nector on the rear of the unit.
The PRIMARY connection can either be connected to another DBC Network
Bridge unit or other CobraNet-compatible component’s PRIMARY port. A
further option is to connect to a port on a 100Mbit Ethernet switch or hub
in order to distribute the network audio to other devices. Devices that are to
communicate with the DBC Network Bridge will all need unique Ethernet IP
addresses assigned. See the CobraNet sections 4.7.8 and 8.3 for more
details.
The SECONDARY connector is for creating a redundant network for backup
purposes. This port should be tied to the backup Ethernet network. In the
event of a failure in the cabling or hardware connected to the PRIMARY
system the DBC Network Bridge will switch to the SECONDARY network in
a matter of seconds.
On each connector are two LEDs. The left LED (IN USE/CONDUCTOR)
lights yellow when the port is in use and will blink if the device is also the
conductor (the CobraNet timing master). The right LED (LINK/ACTIVITY)
lights green when link is established and blinks when network activity is
detected. Both LEDs flash yellow in unison to report a fatal error. The Sec-
ondary Connector has identical LEDs as the Primary Connector.
3.3.7 Control Port Connections
Connect any external circuits you plan to use to control and/or monitor the
DBC Network Bridge via the Control Port. Figure 3.7 shows pin assign-
ments for the Control Port. See the Control Port (Section 5.2.4) for infor-
mation on the operation of the Control Port, and for examples of wiring
circuits to the Control Port connector.
DBC Network Bridge Control Port (DB37)
Pins 1 through 8 are assignable to manually select a binary (on/off) value,
chosen Preset status, or status of any logical binary control or sensor
(most likely gate and Preset).
Pins 20 through 27 provide an analog output from 0 to +10VDC that is
assignable or can reflect an object (including faders) of the unit.
A total of 1 amp of current is available from all outputs.
Pins 12 through 19 are assignable to logic Preset recall and general con-
trol for logical type objects within the unit, and are assignable to any com-
bination of mute controls. Pins 30 through 37 function as analog inputs
and are assignable to any combination of fader controls.
Figure 3.7 Control Port Pin Assignment
Operation Manual
DBC Network Bridge
page 20
4 Operation
4.1 Front Panel Controls
and Indicators
A. LCD Display
LCD digital display shows information about the
currently selected IQ address, inputs, presets,
scenes, and firmware information.
B. Input Display
An eight-segment LED display matrix shows input
signal presence for all eight analog or digital inputs.
C. Power Indicator
Blue LED shows that the unit is plugged in and AC
power is being supplied. The unit does not have a
power on/off switch.
D. Menu/Select Button
Scrolls through the menus of IQ address, inputs,
presets, scenes, and firmware information. Also
used to select a parameter that is found by the Next/
Prev buttons.
E., F. Next/Previous Buttons
These two buttons scroll through parameters in
each menu.
G. Output display
An eight-segment LED display matrix shows output
signals for all eight surround channels.
H. Data Indicator
Amber LED flashes when commands addressed to
the DBC Bridge are received.
I. AES/EBU Indicator
Amber LED illuminates when the unit is switched to
AES digital inputs.
Figure 4.1 Front Panel Controls and Indicators
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Crown 137769-3 User manual

Category
Supplementary music equipment
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI