Danfoss AME 655 / 658SD / 658SU is a versatile and feature-rich device that offers a wide range of capabilities to meet the demands of various applications. Some of its key features and applications include:

  1. Precise Control: The device provides precise control over the positioning of valves and actuators, enabling accurate regulation of flow and temperature in heating, ventilation, and air conditioning systems.

  2. Flexibility: With its adjustable stroke limitation and characteristic modification function, the device can be tailored to suit specific system requirements, ensuring optimal performance and energy efficiency.

Danfoss AME 655 / 658SD / 658SU is a versatile and feature-rich device that offers a wide range of capabilities to meet the demands of various applications. Some of its key features and applications include:

  1. Precise Control: The device provides precise control over the positioning of valves and actuators, enabling accurate regulation of flow and temperature in heating, ventilation, and air conditioning systems.

  2. Flexibility: With its adjustable stroke limitation and characteristic modification function, the device can be tailored to suit specific system requirements, ensuring optimal performance and energy efficiency.

1
AME 65x +
VF 2,3 (DN 100-150)
VL 2,3 (DN 100)
VFS (DN 65-100)
AME 65x +
VFG(S) 2, VFU +
adapter 065B3527
AME 65x +
VFG 3 +
adapter 065B3527
AME 65x +
VFM 2
AME 65x +
AFQM 6
AME 65x +
AFQM PN 16 (DN 65-125)
AFQM PN 25
Installation Guide
AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
ENGLISH
AME 655 / 658 SD / 658 SU www.danfoss.com Page 10
AUTO
=
=
13 mm
4 mm
12-15 Nm
12-15 Nm
A
B
5-95 % RH
MAINTENANCE
FREE
Installation Guide AME 655 / 658 SD / 658 SU
DEN-SMT/SI VI.
LH.J2.02
District Energy
2
AME 658 SU
C
AUTO
=
=
3,5 - 4,5 mm
× 0,7mm
4 mm
T 10
AME 655
3-5 Nm
A
AME 658 SD
3-5 Nm
B
1×
1×
3-5 Nm
Installation Guide AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
33
AUTO
=
=
V
3,5 - 4,5 mm
× 0,7mm
T 10
SN 0 V Neutral
SP 24, 230 V AC/DC Power supply
4, 5 SP(AC)
4
5
SP
SP output
-max 4A
-min 3W
1
SP
2
DIR
INV
2
DIR
INV
Input
3
GND 0 V Neutral
Y
0(2)-10 V
Input
0(4)-20 mA
X
0(2)-10 V
Output
0(4)-20 mA
AME 655
DIP 6 OFF (1a, 1b)
DIP 6 ON (2a, 2b)
AME 658
M16 / M20
SN 0 V Neutral
1,3 24, 230 V AC/DC Power supply
4, 5 SP(AC)
4
5
1
3
SP output
-max 4A
-min 3W
1
SP
2
DIR
INV
2
DIR
INV
Input
3
Optional: AME 655 connected as 3-point version
AME 655
CONTROLLER
CONTROLLER
CONTROLLER
Installation Guide AME 655 / 658 SD / 658 SU
DEN-SMT/SI VI.
LH.J2.02
District Energy
4
2 sec/mm 6 sec/mm
T [sec] 2×h 6×h
h
VFM 2 VF 2,3 (DN 100-150)
VFS (DN 65-100) VL 2,3 (DN 100)
VFG(S) 2 VFG 3
AFQM -
Installation Guide AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
55
AUTO
=
=
>5s = RESET
Set new retract
Max. retracted
>5s = RESET
>5s = RESET
max. extracted
Set new extracted
Max. extracted
Max. retracted
Kv
Kv
Installation Guide AME 655 / 658 SD / 658 SU
DEN-SMT/SI VI.
LH.J2.02
District Energy
6
input
1 3
output
4
5
output
4
5
V
S4
S5
Installation Guide AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
77
LED
Indication type Operating mode
Green LED:
Constantly lit Positioning mode - Actuator is retracting the stem
Constantly lit Positioning mode - Actuator is extracting the stem
F lashing (1 s cycle)
Self stroking mode - Actuator is retracting the stem
F lashing (1 s cycle)
Self stroking mode - Actuator is extracting the stem
Yellow LED:
Constantly lit
Stationary mode - Actuator has reached upper end position (retracted stem)
Constantly lit Stationary mode - Actuator has reached bottom end position (extracted stem)
F lashing
Stationary mode - Single blink when Y signal is presents and double blinks
when Y signal is not connected)
Red LED:
Constantly lit Stand-By mode
F lashing Error Mode
Red/ Yellow
LED
F lashing (1 s cycle)
Set up stroke limitation (retracted stem)
F lashing (1 s cycle)
Set up stroke limitation (extracted stem)
Dark
No indication No power supply
AUTO
=
=
3,5 - 4,5 mm × 0,7mm
T 10
0,7-1,1 Nm
Installation Guide AME 655 / 658 SD / 658 SU
DEN-SMT/SI VI.
LH.J2.02
District Energy
8
A
1s =
STAND BYON
STAND BYOFF
Constantly lit
LED : Red
B
1
B
2
>5s = RESET
LED : Green
F lashing
(1 s cycle)
F lashing
(1 s cycle)
F lashing
LED : Yellow
AUTO
=
=
Installation Guide AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
99
To avoid personal injury and damage to devices,
it is absolutely essential for these instructions
and safety notes to be read carefully and
reviewed prior to assembly and use.
Do not dismantle actuators with the safety
spring function! There is risk of injury and death
in the event of improper handling!
The actuator is heavy. Handle with care to avoid
injury or product damage.
Wiring
Do not touch anything on the PCB! Do not
remove the cover before the power supply is
fully switched o.
Max. current output permitted on
terminals 4 and 5 is 4 A. Min. power is 3W.
NOTE:
If AME 655 is connected as 3 point version only
DIP1 and DIP2 are active
Actuator mounting to valve
Stem connections
Electrical connection
DIP switch setting
DIP1: FAST/SLOW – Speed selection
- FAST position; 2 s/mm
- SLOW position; 6 s/mm
DIP2: DIR/INV – Direct or inverse acting
selector
- DIR position; the actuator is directly reacting
to input signal
- INV position; the actuator is inversely
reacting to input signal
DIP3: 2-10V/0-10V – Input/output
- 2-10V position; the input signal ranges from
2-10 V (voltage input) or 4-20 mA (current
input)
- 0-10V position; the input signal ranges from
0-10 V (voltage input) or 0-20 mA (current
input)
Signal range selector sets Y and X signals.
DIP4: LIN/MDF – Characteristic
modication function
- LIN position; linear correlation between Y
signal and stem position
- MDF position; enables modied correlation
between Y signal and stem position. Degree
of modication depends on setting of
potentiometer CM.
Function enables changes to be made to
MCV (valve and actuator) characteristics (for
example, linear to logarithmic and logarithmic
to linear) and works with all combinations of DIP
switch settings.
DIP5: 100%/95% – Stroke limitation
Adjustable stroke limitation of retracted or
extracted actuator stem position.
DIP switch 5 needs to be reset prior to
procedure (5.2) to 100% (5.1) and set to 95%
(5.3) until the self-stroking procedure has
concluded (5.4). Retracted icon (5.5) on actuator
will blink red-yellow when actuator stops at
max. retracted stem position (5.5) and will
blink as long as it is not set to a new retracted
position (5.6) by pressing buttons
to set the required position (observe ow on
ow meter). Press and hold reset button for 5
seconds (5.7) and then set new extracted stem
position by pressing buttons
.
Extracted icon (5.8) will blink red-yellow as
long as it is not set to new extracted position
by pressing and holding reset button for 5
seconds.
DIP6: C/P – Output signal mode selector
An output signal is present on terminal 4
when the position of the actuator is equal
to or lower than the S4 set point. An output
signal is present on terminal 5 when the
position of the actuator is equal to or lower
than the S5 set point.
DIP6 position C provides a constant output
signal on terminals 4 or 5, regardless of the
input signal.
DIP6 position P provides a pulse signal through
parallel or cascade electrical wiring input
1 and 3 dependents from the controller to
output terminals 4 and 5.
DIP7: Smart function selector:
- OFF position; the actuator does not try to
detect oscillations in the system
- ON position; actuator enables special anti-
oscillation algorithm – see section on anti-
oscillation algorithm
DIP8: Uy/Iy – Input signal type selector:
- position Uy; input signal Y is set to voltage (V)
- position Iy; input signal Y is set to current
(mA)
DIP9: Ux/Ix – Output signal type selector:
- position Ux; output signal X is set to voltage
(V)
- position Iy; output signal X is set to current
(mA)
NOTE:
Y detection is disabled if DIP8 is set to ON positions
and DIP3 is set to OFF position.
Functions accessible from cover
RESET button
AME 655 actuators have an external RESET
button, which is located on the top cover of
the actuator next to the LED indicators. With
this button you can enable or disable standby
mode (press once) or self-stroking mode (press
and hold for 5 seconds). See next paragraph for
more details.
Final step of electrical connection
LED signalisation
Self-stroking mode
Self-stroking mode begins automatically the
rst time the actuator is powered on. To start
the self-stroking procedure, press and hold the
RESET button for 5 seconds until the green
light starts ashing. End positions of the valve
are automatically set and the actuator goes into
stationary mode and starts responding to
the control signal.
Stand-By mode (versions AME 655)
Press the RESET button to enter standby mode.
The actuator stops in the current position
and stops responding to any control signal. A
red light remains constantly lit. You can now
manually operate the actuator.
Manual Operation
Mechanical and electrical operation must
not be used at the same time!
AME 655 actuators can be manually positioned
when in standby mode or when there is no
power supply (mechanically).
Actuator
type
Mechanical
operation
Electrical
operation
AME 655
AME 658
Mechanical manual operation
A
AME 655 actuators have a manual operation
knob on the top of the housing, which enables
manual positioning of the actuator.
Mechanical manual operation must only
be used when there is no power supply.
Electrical manual operation
B
AME 655 actuators have two buttons on the
top of the housing that are used for electrical
manual positioning (up or down) if the actuator
is in standby mode. First, press and hold
the RESET button until the actuator goes to
standby mode (red LED is lit). By pressing the
button, the stem will be extracted and
by pressing the
button, the stem will be
retracted.
Danfoss can accept no responsibility for
possible errors in catalogues, brochures and
other printed material. Danfoss reserves the
right to alter its products without notice. This
also applies to products already on order
provided that such alterations can be made
without subsequential changes being necessary
in specications already agreed.
All trademarks in this material are property of
the respective companies. Danfoss and the
Danfoss logotype are trademarks of Danfoss
A/S. All rights reserved.
ENGLISH
Installation Guide AME 655 / 658 SD / 658 SU
DEN-SMT/SI VI.
LH.J2.02
District Energy
10
Installation Guide AME 655 / 658 SD / 658 SU
District Energy VI.
LH.J2.02
DEN-SMT/SI
11
Installation Guide AME 655 / 658 SD / 658 SU
Produced by Danfoss A/S © 05/2015
73691550/VI.LH.J2.02
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss AME 655 / 658SD / 658SU Operating instructions

Type
Operating instructions

Danfoss AME 655 / 658SD / 658SU is a versatile and feature-rich device that offers a wide range of capabilities to meet the demands of various applications. Some of its key features and applications include:

  1. Precise Control: The device provides precise control over the positioning of valves and actuators, enabling accurate regulation of flow and temperature in heating, ventilation, and air conditioning systems.

  2. Flexibility: With its adjustable stroke limitation and characteristic modification function, the device can be tailored to suit specific system requirements, ensuring optimal performance and energy efficiency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI