Danfoss AME 655/658 SU/658 SD/659 SD Operating instructions

Type
Operating instructions
1
AME 65x +
VF 2,3 (DN 100-150)
VL 2,3 (DN 100)
VFS (DN 65-100)
AME 65x +
VFG(S) 2, VFU +
adapter
AME 65x +
VFG 3 +
adapter
AME 65x +
VFM 2
AME 65x +
AFQM 6 +
adapter
AME 65x +
AFQM PN 16 (DN 65-125)
AME 65x +
AFQM PN 25 +
adapter
Installation Guide
AME 655 / 658 SD / 658 SU / 659 SD
District Energy VI.LE.M2.0S DEN-SMT/SI
ENGLISH
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.com Page 10
ČESKY
AME 655/658 SD/658 SU/659 SD www.cz.danfoss.com Strana 11
DANSK
AME 655/658 SD/658 SU/659 SD www.varme.danfoss.dk Side 12
DEUTSCH
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.com Seite 13
FRANÇAIS
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.com Page 14
MAGYAR
AME 655 / 658 SD / 658 SU / 659 SD www.hu.danfoss.com 15. oldal
LIETUVI
AME 655 / 658 SD / 658 SU / 659 SD www.sildymas.danfoss.lt 16 psl.
POLSKI
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.pl Strona 17
РУССКИЙ
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.com Страница 18
SRPSKI
AME 655/658 SD/658 SU/659 SD
www.grejanjedanfoss.com
Strana 19
中文
AME 655 / 658 SD / 658 SU / 659 SD www.danfoss.cn 20
4
AUTO
=
=
3,5 - 4,5 mm
× 0,7mm
T 10
SN 0 V Neutral
SP 24, 230 V AC/DC Power supply
4, 5 SP(AC)
4
5
SP
SP output
1
SP
2
DIR
INV
2
DIR
INV
Input
3
GND 0 V Neutral
Y
0(2)-10 V
Input
0(4)-20 mA
X
0(2)-10 V
Output
0(4)-20 mA
AME 655
DIP 6 OFF (1a, 1b)
DIP 6 ON (2a, 2b)
AME 658/659
Wire
Ferrite
M16 / M20
M16
M20
SN 0 V Neutral
1,3 24, 230 V AC/DC Power supply
4, 5 SP(AC)
4
5
1
3
SP output
1
SP
2
DIR
INV
2
DIR
INV
Input
3
Optional: AME 655 connected as 3-point version
AME 655
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
DEN-SMT/SI VI.LE.M2.0S District Energy
6
LIN
MDF
SLOW
INV
0-10V
95%
P
Iy
Ix
FAST
DIR
2-10V
100%
C
Uy
Ux
S4
S5
input
1,3
C
P
output
4,5
output
4,5
C
P
Ux
Ix
Ux
Ix
Uy
Iy
0(2) - 10V
Uy
Iy
0(4) - 20mA
0(2) - 10V 0(4) - 20mA
100%
95%
100%
95%
100% stroke
95% stroke
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
DEN-SMT/SI VI.LE.M2.0S District Energy
77
AUTO
=
=
3,5 - 4,5 mm
× 0,7mm
T 10
0,7-1,1 Nm
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
District Energy VI.LE.M2.0S DEN-SMT/SI
99
>5s = RESET
LED : Green
Flashing
(1 s cycle)
Flashing
(1 s cycle)
Flashing
LED : Yellow
RESET
AUTO
=
=
AME 655/658
1s =
STAND BY−ON
STAND BY−OFF
Constantly lit
LED : Red
AME 655/658/659
A
B
1
B
2
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
District Energy VI.LE.M2.0S DEN-SMT/SI
10
To avoid injury and damage to persons and
devices, it is absolutely necessary these
instructions and Safety notes attached are
carefully read and observed prior to assembly
and commissioning.
Do not dismantle actuators with safety spring
function! Danger of injury and life in case of
improper handling!
Actuator is heavy. Handle with care to avoid
injury or product damage.
Wiring
Do not touch anything on the PCB! Do not
remove the cover before the power supply is
fully switched off.
Max. allowed current output on terminals
4 and 5 is 4 A.
NOTE:
If AME 655 is connected as 3 point version only
DIP1 and DIP2 are active
DIP switch setting
DIP1: FAST/SLOW – Speed selection
- FAST position; 3 (4) s/mm (see Tech. data)
- SLOW position; 6 s/mm
DIP2: DIR/INV – Direct or inverse acting
selector
- DIR position; the actuator is direct acting to
input signal
- INV position; the actuator is inverse acting to
input signal
DIP3: 2-10V/0-10V – Input/output
- 2-10V position; the input signal is in the range
from 2-10 V (voltage input) or from 4-20 mA
(current input)
- 0-10V position; the input signal is in the range
from 0-10 V (voltage input) or from 0-20 mA
(current input)
Signal range selector sets Y and X signal.
DIP4: LIN/MDF – Characteristic
modification function
- LIN position; Linear correlation between Y
signal and stem position
- MDF position; Enables modified correlation
between Y signal and stem position. Degree
of modification depends on setting of
potentiometer CM.
Function enables to change MCV (valve and
actuator) characteristic (for example linear to
logarithmic and logarithmic to linear) and works
with all combinations of DIP switch settings.
DIP5: 100%/95% – Stroke limitation:
100% position; Full stroke
95% position; Stroke limited to 95%
DIP6: C/P – Output signal mode selector
Output signal is present on terminal 4 when
position of the actuator is equal or lower
then setpoint of S4.
Output signal is present on terminal 5 when
position of the actuator is equal or lower then
setpoint of S5.
position C; output signal is present on
terminals 4 or 5 independent of the input
signal
- position P; output terminals 4 and 5 are
bridged with input terminals 1 and 3
DIP7: Uy/Iy –Input signal type selector:
- position Uy; input signal Y is set to voltage (V)
- position Iy; input signal Y is set to current
(mA)
DIP8: Ux/Ix –Output signal type
selector:
- position Ux; output signal X is set to voltage
(V)
- position Iy; output signal X is set to current
(mA)
NOTE:
If DIP7 is in ON position, Y detection is disabled.
Functions accessible from cover
RESET button
Actuators AME 655/658/659 have external
RESET button which is located on top cover of
the actuator next to LED indicators. With this
button you can enter or exit Stand-By mode
(press once) or Self stroking mode (press and
hold for 5 seconds). See next paragraph for
mode details.
Self stroking mode
Self stroking mode starts automatically
the first time when power supply is
applied to the actuator. To start self
stroking procedure press and hold
RESET button for 5 seconds until
the green light starts flashing. End positions of
the valve are automatically set and the actuator
goes to stationary mode and starts
responding to the control signal.
Stand-By mode
(versions AME 655/658/659)
Press the RESET button to enter
Stand-By mode. The actuator stops
in current position and stops responding
to any control signal. Red light is
constantly lit. You can now manually
operate the actuator.
Manual operation
Mechanical and electrical operation are
not allowed to be used at the same time!
Actuators AME 655/658 can be manually
positioned when in Stand-By mode or when
there is no power supply (mechanically).
Actuators AME 659 can be manually positioned
only in Stand-By mode.
Actuator
type
Mechanical
operation
Electrical
operation
AME 655
AME 658
AME 659
Mechanical manual operation
A
Actuators AME 655/658 have a manual
operation knob on the top of the housing which
enables hand positioning of the actuator.
Mechanical manual operation shall be used
only when no power supply.
Electrical manual operation
B
Actuators AME 655/658/659 have two buttons
on the top of the housing that are used for
electrical manual positioning (up or down) if
the actuator is in Stand-By mode. First press the
RESET button until the actuator goes to Stand-
By mode (red LED is lit). By pressing the upper
button
the stem will be extracted and by
pressing the lower button
the stem will be
retracted.
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
DEN-SMT/SI VI.LE.M2.0S District Energy
LANGUAGEENGLISH
2121
Installation Guide AME 655 / 658 SD / 658 SU / 659 SD
District Energy VI.LE.M2.0S DEN-SMT/SI
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Danfoss AME 655/658 SU/658 SD/659 SD Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI