Dedicated Micros 2060, 2060 PTZ Dome, IP Dome (2060 / 2040) User manual

  • Hello! I am an AI chatbot trained to assist you with the Dedicated Micros 2060 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2060 Dome Camera
Operation & Programming Manual
Weatherproof and Indoor versions
www.dedicatedmicros.com
Dedicated Micros ©2009
2
2060
Whilst every attempt is made to ensure these manuals are accurate and current, Dedicated Micros reserve the right to
alter or modify the specication of the machine described herein without prejudice.
Contents
Introduction .......................................................3
Programmable Features ...................................4
Operation ..........................................................6
Menu Flow Charts .............................................20
Alternative Controllers .......................................22
Troubleshooting ................................................25
Dedicated Micros ©2009
3
2060
Introduction
The Dedicated Micros 2060 camera is a precision unit, offering a wide variable speed range, together with
a large pre-set memory for positions, tours and alarm responses. There are sensitive day/night camera
versions with a switchable infra-red lter and with 36 times or 18 times optical zoom lenses plus 12 times
digital enhancement suitable for outdoor use, or a colour/mono camera with 18 times optical zoom and
12 times digital enhancement suitable for indoor applications. The external 2060 camera is weatherproof
(IP-66 rated).
The unit has a comprehensive set of features as standard, which can be tailored for individual preferences.
These can be accessed through an internally generated set of menus overlaid on the video signal if the
controller does not have a suitable layout.
Outline Specication:
Speed range 0.05 to 300° / second max (both Pan and Tilt)
Repeatability 5 minutes of arc
Control RS485 half duplex or simplex, 9600 Baud Dennard, Pelco P, Bosch Ultrak
OR ‘Up the coax’ for Dedicated Micros, Dennard, BBV, Baxall or Pelco
protocols
Storage capacity 200 preset positions, with identifying title of up to 20 characters
100 tours of up to 16 preset positions
100 alarm response memory
Power Supply 24VAC, Camera & control electronics:-20W
Dimensions Outdoor variant: 206mm diameter x 240mm overall
Indoor variant: 189mm diameter x 250mm overall
Protection Outdoor variant - BS EN 60529 to level IP66 (no water ingress)
Indoor variant - BS EN 60529 to level IP50 (no dust ingress)
Weight Outdoor variant: 3kg + mounting bracket
Indoor variant: 2kg + mounting bracket
Mounting Congurations Ceiling mount, pendant mount, wall bracket, corner mount, snowdrop
parapet & tile mounts available
18X zoom day/night camera module
Sensor ¼” Ex-view HAD progressive scan CCD
Optical range 3.4mm to 122.4mm zoom; F1.6 to F4.5
Auto-focus with manual override Privacy zones
24 programmable zones (8 on screen at any time)
Video sensitivity 0.07 lux color 50IRE
0.01 lux ICR-on mode 50IRE
Video resolution 440000 pixels PAL, 380000 NTSC
530 TVL
Video output 1.0v p-p composite, negative synch
36X zoom day/night camera module
Sensor ¼” Ex-view HAD progressive scan CCD
Optical range 3.4mm to 122.4mm zoom; F1.6 to F4.5
Auto-focus with manual override 24 programmable zones (8 on screen at any time)
Video sensitivity 0.1 lux color 50IRE
0.01 lux color ICR-on 50IRE
Video resolution 440000 pixels PAL, 380000 NTSC
530 TVL
Video output 1.0v p-p composite, negative synch
18X zoom colour/mono camera
Sensor ¼” Super HAD CCD
Optical range 4.1mm to 73.8mm zoom; F1.4 to F3.0
Auto-focus with manual override Privacy zones
24 programmable zones (8 on screen at any time)
Video sensitivity 1 lux color 50IRE
Video resolution 440000 pixels PAL, 380000 NTSC
More than 460 TVL PAL, 470 TVL NTSC
Video output 1.0v p-p composite, negative synch
Dedicated Micros ©2009
4
2060
Programmable Features
The Dedicated Micros 2060 Camera has a number of features which can be selected by the System
Supervisor when the dome is installed. Any of these can be altered subsequently, or cancelled altogether, to
give the best operational responses for any particular application. They are invoked or cancelled through on-
screen menu structures and the settings are then retained in non-volatile memory so that they are not affected
by a loss of power.
The features, and what they offer, are described below:
Preset Positions
Up to 200 positions can be stored and recalled at any time. Each position stores the Pan, Tilt, Zoom, and
Focus positions as well as the position title.
Preset Position Titles
Each preset position title can have up to 20 alphanumeric characters to identify the associated position
uniquely. The default title position lies at the top left hand corner of the video picture, left justied, but this can
be altered if required.
The preset position titles only appear at the position they identify: any movement from that position will remove
them.
Tours
Up to 100 tours can be stored and recalled at any time. Each tour can contain up to 16 positions together with
a ‘Dwell’ time at each position plus the ‘Travel Time’ that the dome unit must take to reach the next position.
When the last position in the tour is reached, the tour ‘loops’ back to the rst position.
Real Time Clock
The Dedicated Micros 2060/N dome camera is tted with a real time clock to provide time and date marks for
the operator and the recording system if required. A range of selectable formats can provide time and date
displays and the unit is able to use the information to provide enhanced alarm functions where the reaction to
an alarm can be modied depending on the time of day or the day of the week.
Alarm Response
Up to 100 Alarm responses can be stored. Each alarm response creates a specied reaction to an alarm
number. This is a very powerful feature, allowing a number of domes, or any other device conforming to the
Dedicated Micros protocol, to invoke a pre-set alarm action from one single loop broadcast command.
Bottom Flip
The dome will automatically pan through 180 degrees as fast as possible when tilted fully down so that it is
possible to follow a person or car, moving directly underneath the dome, with only a single joystick direction to
consider.
Camera Mode
The camera can be switched between color and monochrome mode and can be selected as color/mono to
automatically switch to mono when the light level is insufcient for good quality color pictures.
Digital Zoom Extension
The camera system allows an extension of the optical zoom by selecting more of the central part of the picture
and expanding this to ll the frame. This feature is selectable.
Dome Selection Cursor
The menu structure itself, and the choices and selections offered, are searched and invoked by a single cursor
or ashing character and the direction in which this moves depends on the particular control panel in use. The
direction of movement can be reversed separately for horizontal and vertical movement if required.
Text Positioning and Selection
All text can be positioned where it is wanted, replaced with default text (eg: Position 31, or Sector 18), or
removed as required.
Joystick Range
Even if the control panel has a wide range proportional joystick output, the dome has such a wide speed range
that both a fast and a slow speed range are needed to realize the full performance (provided of course that the
control panel in question has a facility to invoke these separately).
The slow speed range is simply the same as the fast speed range following the same in-built correlation law,
but divided by a constant. This constant can be set between 2 and 128.
Host polling
When the dome is congured for communication using RS485 protocols it can be set to check its
communication link at regular intervals. If a continuous data stream is expected from the controller, enabling
Host Polling will get the dome to report a communications error if nothing is received for 5 seconds. Normally,
this setting is disabled.
Dedicated Micros ©2009
5
2060
Error Reporting
The dome constantly monitors its own health and is able to indicate that a problem has occurred by a ashing
square in the top right hand corner of the transmitted picture. The cause can subsequently be requested when
convenient. Alternatively, the unit can display the error text instead of the ashing square.
Activity light
A green LED provides some diagnostic help when rst switching the dome on and also indicates when
command signals are received. As it may be visible externally it can be switched on or off.
User Timeout
There is a possibility that the dome may be left pointing at an unhelpful scene and, for whatever reason,
‘forgotten’. To cater for this eventuality, two settings have the specic function of acting to prevent this
happening. These are Preset 001 and Tour 001.
A time delay can be set between 1 and 999 seconds and a default response to the time-out being reached also
dened. If the time is exceeded after any joystick/key entry Pan and Tilt input at the Control Panel then the
default action will occur.
If a delay time of 0 is set, no default action will occur and the unit will wait indenitely for the next user input.
If a dome menu screen is left waiting for an input for more than 3 minutes then the system times out and the
dome resumes its previous activity.
Set Video Amplication
This facility allows the video gain to be adjusted from the normal setting, with four levels available. Video lift
can be tuned on or off and is normally set to the Off position.
Privacy mode
It is sometimes desirable to prevent operators from viewing certain areas. To meet this requirement the Privacy
mode allows black patches to be set up to cover these areas.
The size of the patch overlaid is the size of the monitor view at whatever zoom setting is used. When zooming
out, the patch reduces in size so that it only covers the original area.
International
The 2060 Dome menus can be displayed in different languages:
The Standard Dome has menus in English, Dutch, French, Italian and Spanish
The Northern European version (denoted by ‘N’ in the part code) has menus in English,
Danish, Finnish, German and Swedish
The Eastern European version (denoted by ‘E’ in the part code) has menus in English,
Croatian, Czech and Polish.
Dedicated Micros ©2009
6
2060
Operation
The Dome Cameras are open protocol devices. Consequently, there are several different manufacturers’
controllers available to drive it. All of the many features offered by the dome are programed from one of three
menu structures. Each controller will have individual control congurations which make it essential that the
user reads the controller manual to ascertain which button activation gives access to the menu features.
For control using older Dedicated Micros controllers, and other brand controllers, refer to ‘Alternative
Controllers’.
Accessing 2060 Menus from DV-IP DVRs
The 2060 on-screen menus on a Dedicated Micros DV-IP DVR can be accessed from the Live View screen via
the ‘PTZ Program’ option, refer to ‘2060 Dome Camera - Installation and Operation Guide’ for more information
on Camera Telemetry and Serial Port Settings.
If the Dome is congured for ‘up the coax’ telemetry (ie with the address switches set to ‘FD‘, refer to 2060
Dome Camera - Installation and Operation Guide) then the camera telemetry on the DVR should be set to
‘Dennard-C‘.
If the Dome is congured for Dennard RS485 telemetry then the camera telemetry on the DVR should be
set to ‘Dennard’, and the RS485 cable from the dome should be connected to the serial port congured for
telemetry on the DVR.
Red Dome Menu Select to view the 2060 dome main menu which
will be displayed over the video output from
the dome. Use the pan and tilt joystick on the
keyboard or remote control, or the live screen
view control to navigate the dome menus.
Green Select This option selects the current highlighted dome
sub menu content.
Yellow Return Not applicable to the 2060 dome menus.
Blue Menu Exit This will fully exit the 2060 dome menus.
Purple Back Return to the previous page of the Viewer menu.
Dedicated Micros ©2009
7
2060
Main Menu
When called, the Main Menu screen will display the following options, against a camera display background,
with a cursor at the left hand edge:
Go to Preset
Start Tour
Technician Menu
Supervisor Menu
│
Exit
Using the joystick, or direction arrow keys, move up or down the list to select the feature required then press
the appropriate key(s) to accept/select it. If ‘Exit’ is chosen the menu is cleared and no other action is taken by
the dome.
Go to Preset or Start Tour
These selections allow the operator to recall the full range of stored Preset positions and Tours, even if the
control panel has neither the numerical range nor general ability to do so.
Note: This screen only allows existing preset positions and tours to be accessed.
To set up new presets or tours, see the sections on Supervisor Menu ->Store/Edit Preset or Supervisor
Menu ->Store/Edit Tour.
The display will prompt for the required numerical entry with the following subsidiary menu:
Preset Number _ _ _ (or Tour Number)
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry │
Return
The cursor can be moved across the numerical line, using the joystick or control buttons, until the desired
number is reached. The characters will ash their position in turn and, as soon as one is selected with the
SELECT button, will be displayed in the _ _ _ part of the display.
Leading zeros need not be entered (eg 001 may be entered simply as ‘1’) but the entry must be within
range, eg 001 - 250 for Presets and 001 - 100 for Tours. Entries outside the range will cause an ‘Illegal Entry’
message to ash, and the entry must be cleared and re-entered.
When the digits have been selected, Accept Entry will invoke that choice and the screen will automatically
clear to the desired camera position.
To change the choice, ‘Clear Entry’ will start the process again.
Note: Preset number 1 and Tour number 1 should be allocated to the most common or important views.
These values are the ones to which the dome automatically returns following a power cut if no
operator is in attendance, refer to Enable/Disable options->power fail.
Dedicated Micros ©2009
8
2060
PIN number entry
When the Technician or Supervisor menu is called the following screen appears. The password or PIN Number
is keyed in using the same method as used with previous entries.
Enter PIN _ _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Cancel
The cursor is run across the numerical line, using the joystick or control buttons, until the desired number is
reached. The characters will ash their position in turn and as soon as one is selected with the SELECT button
it will be displayed in the _ _ _ _ part of the display.
When all four digits have been selected, Accept Entry will invoke that choice and the screen will automatically
change to the selected menu i.e. the Technician or Supervisor menu.
THE FACTORY SET PASSWORDS (PINs), WHICH CAN BE CHANGED BY THE TECHNICIAN OR
SUPERVISOR IN THEIR RESPECTIVE MENUS, ARE PRINTED BELOW.
TO PREVENT UNAUTHORIZED CHANGES BEING MADE TO SETTINGS OR STORED CAMERA
POSITIONS, IT IS ADVISED THAT PIN NUMBERS ARE KEPT IN A SAFE PLACE.
To gain access to the Supervisor Menu, enter PIN as ‘1111’
To gain access to the Technician Menu, enter PIN ‘9999’
Dedicated Micros ©2009
9
2060
Supervisor Menu
The Supervisor menu allows the supervisor not only to duplicate the operator menu functions, but also
to programme Preset positions (with their identifying title) and Tours. Additionally, cursor setting and text
positioning and selection are accessed here.
The functions are split into a series of underlying menus in ‘layers’. When returning from most underlying
menus, the overlying menu is re-presented. The functions which are less likely to be needed lie deeper in the
structure.
The Supervisor Menu displays:
Store Edit Preset
Store Edit Tour
Alarm Setup
Supervisor Options
Change PIN
Privacy Zone Setup
Return
Exit
Store/Edit Preset
The rst option enables the supervisor to dene a view (including pan, tilt and zoom settings) and store it for
future recall.
Note: The camera to be programed with presets must be visible when this screen is entered.
Selecting this option calls up the following screens.
Preset Number _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return Without change
Delete Preset
Select the preset number using the joystick. When the number is accepted, a new display will allow the
supervisor to give this position a name (such as ‘Main Gate’ or ‘Front Door’) or use the default names stored in
the dome software. The screen will prompt with:
Edit Preset Text -
Yes
No
Select ‘No’ to use the default names or ‘Yes’ to enter a new name through the following screen.
Dedicated Micros ©2009
10
2060
ABCDEFGHIJKLMNOPQRSTUVWX
YZabcdefghijklmnopqrstuv
wxyz1234567890;/*=+.-
Backspace
Return Without change
Accept Entry
_ _ _ _ _ _ _ _ _ _ _ _
The title choice is made as usual with the cursor and accepted when ready (which will store the chosen Title
with the stored Preset position). Backspace allows a correction to be made while ‘Return without change’ will
store the Preset position with the default title. The title appears in the _ _ space as it is compiled.
Note: The ‘_’ symbols indicate where the title will appear - they do not appear on-screen
Store/Edit Tour
A Tour is a predened journey taken by the camera, between a number of Preset positions. Before accessing
this facility, ensure that all the required Preset positions have been stored, as shown in the previous section.
Choosing to program a Tour rst requires the Tour Number to be entered in an identical procedure to selecting
a Position (except that the range must lie between 001 and 100). Once the number has been accepted, a
subsidiary menu is displayed:
Item _ _ _ in tour _ _ _
P P P D D T T
Old _ _ _ _ _ _ _
New _ _ _ _ _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Return Without Change
Store Tour
If a tour has already been established on this number its initial data is displayed as ‘Old’. This data can be
edited by adding new values or a new tour can be established.
Edit the entry using the joystick, note that the _ _ _ characters have specic functions: The rst three
characters, PPP, represent a Preset position number. ‘DD’ is the dwell time that the camera must spend
stationary at that position and ‘TT’ represents the time that the camera must take to reach the next position in
the tour. The times are entered as seconds, between 01 and 99. If no value is entered, the Tour will use the
default values of 2 seconds dwell time and 3 seconds travel time.
When all characters are completed and then accepted, the display clears the entry ready to receive the next
position information and the ‘Item’ counter is incremented. When all entries are complete, select the ‘Store
Tour option.
Dedicated Micros ©2009
11
2060
Alarm Setup
Alarms are inputs into the dome which require the dome to undertake a specic action. They may come from
a number of external sources, such as door entry systems or PIR motion sensors. The Dedicated Micros 2060
dome has a clock function that enables the supervisor to select different actions depending on the time of day
or the day of the week. The Alarm Setup screen provides access to three options:
Alarm Action Setup
Mask Alarm
Select holidays
Return
Exit
Alarm Action Setup
On selecting this function the supervisor must select an alarm number in the usual way with the following
screen:
Alarm Number _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
Delete Alarm
Accepting the Alarm number brings up the following screen:
Alarm Number _ _ _ Select P or T
PTnnn
Old _ _ _
New _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
This allows a specied preset position P or tour T to be stored, along with its identication number ‘nnn’
which will be implemented when the alarm is activated. To select an option, use the code ‘01’ for Tour or ‘10’
for Preset (the 1 under the P or T selects its use; 11 is invalid). Accepting the entry will increment the alarm
number allowing all inputs to have an action allocated to them or their existing action, shown as ‘Old’, modied.
The alarm action will be sustained for a duration set by the user time-out (see Supervisor Options -> Set
User Time-out).
Dedicated Micros ©2009
12
2060
Mask Alarms
Alarm responses can be modied, depending on when they are activated. Selecting this facility will bring up
the following screen:
Item _ _ _ of Alarm Mask
MTWTFSSHhhmmhhmm
Old _ _ _
New _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
Save And Return
The letters displayed indicate:
MTWTFSS Monday to Sunday
H Holiday
hhmm Time of ‘Mask On’
hhmm Time of ‘Mask Off’
Entering a ‘1’ under a day of the week means that the alarms will be masked – i.e. they will not cause a
response from the dome – on that day. Similarly, a ‘1’ under the Holiday means that the alarm is masked on
specied holidays (note that the setting for a holiday will override the setting for a day of the week). The mask
will operate throughout the days selected unless a mask on and off time are entered. This is achieved through
numerical entry of the time using the 24hr clock. The mask temporarily disables all connected alarms.
Example
If motion sensors have been connected into the dome but are only required to operate outside of normal
working hours they can be masked by entering the code ‘1111100008301800’. This masks the alarms on Mon
– Fri between 08.30 a.m and 6 p.m. Outside these times, and at the weekends and on holidays, the dome will
respond to the alarms as desired.
To add complete exibility, up to ten levels of conguration are available, indicated by the ‘Item number
on the screen. As each entry is accepted the number increments until the full action is saved. Secondary
levels allow different masking times to be selected on different days. In the example above, it may be that
the building closes early on Friday. To achieve the different times, the rst code (item) would be modied to
‘1111000008301800’ and a second item code entered as ‘0000100008301400’.
Now, the rst mask only applies
from Monday to Thursday while t
he second level masks the alarms on Fridays,
between 8.30 a.m. and 2 p.m. More
complex masks can be built up using the same logic for more variations.
Select Holidays
Up to 15 days can be programed in as holidays when the alarm action may require modication. When the
option is selected the following screen is displayed:
Item _ _ _ of Holiday Days
ddmm
Old _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
New _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
Save and Return
Dates can now be entered (in the format ddmm) to dene the holidays for the year. Accepting each entry will
bring up a prompt for the next one. Select ‘Save and Return’ when complete.
Note: Some holiday dates will need to be reassigned at the start of each year.
Supervisor Options
A number of functions are grouped under the Supervisor Options category. Most of these alter the way in
which text and information is presented to the operator but there are some camera settings which can be
altered to suit the installation requirements.
Selecting the options menu brings up the following screen:
Dedicated Micros ©2009
13
2060
Digital Zoom: disabled
Bottomip: enabled
Freeze frame: disabled
Set User Time-out: none
Set Data/Time/Language
Preset Text Options
Back
Exit
The rst three options relate to camera facilities and are all set in the same way. To change the setting,
move the cursor up/down until it is alongside the feature. Moving the joystick to the left or right (or pressing
the left/right direction arrows) will scroll through alternative settings. Moving up or down will x the value on
the screen. If the digital zoom is enabled the feature is automatically invoked by the camera when the zoom
control is held in after the optical zoom has reached its mechanical end stop.
The digital zoom setting is stored with any preset positions, but if the digital zoom option is later disabled, the
preset positions involved will only return the position with the optical zoom at full extension.
The bottom ip facility may be used to track objects moving directly under the dome. With this disabled, the
camera view can be moved down until it looks directly under the dome but remains in that orientation. With
bottom ip enabled, the camera will be automatically rotated through 180° to allow the operator to track the
object as it moves on, away from the dome.
The freeze frame option, when selected, will hold the last view on the display while the dome moves at full
speed to a preset position. On arrival, the normal image view is displayed. This avoids a blur as the dome
moves at high speed to preset positions.
Set User Time-out
The user time-out facility can be used to select what the dome should do if it is left idle by the operator.
Selecting this option will bring up the following screen:
SSSPT
Old _ _ _
New _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
The screen allows for the selection of a default time-out from 1 - 999 seconds entered as ‘SSS’. This is the
time between the last joystick (or P/T keys) input from the operator, and an automatic move to the start of the
default Tour or to the default Position, provided these have been programed. The value for ‘PT’ denes which
action to take. Entering code 01 will select the Tour and 10 will select the Preset position (11 is an illegal entry).
Accepting the entry will return the supervisor to the Options menu and the time selected will be displayed on
the screen. If a time-out of zero is selected, the display will show ‘none’ and the dome will wait indenitely for
the next operator action.
Dedicated Micros ©2009
14
2060
Set Date/Time/Language
The Dedicated Micros 2060 dome has a Real Time Clock which must be set up on installation. The unit
may also contain other language options and an ability to select and change the format for the time display.
Selecting this option brings up the following screen:
Language: English
Date Format: dd-mm-yy
Time Format: hh:mm:ss
Set Time and Date
Save and Return
Save and Exit
To change the Language, Date Format or Time Format setting, move the cursor up/down until it is alongside
the feature. Moving the joystick to the left or right (or pressing the left/right direction arrows) will scroll through
alternative settings. Moving up or down will x the value on the screen.
The time and date format determine the way in which the normal operator viewing screen displays the time
and date. Several options are available by scrolling through the list and it is also possible to switch the time
and date display off if preferred.
When setting the time or date the following screen is presented:
yymmddhhmm
Old _ _ _ _ _ _ _
New _ _ _ _ _ _ _
0 1 2 3 4 5 6 7 8 9 0
Accept Entry
Clear Entry
Return Without Change
Using the numerical entry, the current date and time can be entered or the existing values left unchanged.
Preset Text Options
The names allocated to preset camera views can be created individually or a default name can be allocated.
This default name is pre-programed as “Position” but this can be changed if required by using this facility. The
location of the name on the screen can also be adjusted. The following screen is presented:
Preset txt justify : L
Default preset txt: On
Edit default text
Return
Exit
The preset position name can be displayed on the left or right of the screen or switched off by selecting the
appropriate feature and moving left/right to toggle the value. If the default name needs to be altered then
selecting the Edit facility will bring up the virtual keyboard used to enter the name:
Dedicated Micros ©2009
15
2060
ABCDEFGHIJKLMNOPQRSTUVWX
YZabcdefghijklmnopqrstuv
wxyz1234567890;/*=+.-
Backspace
Return Without change
Accept Entry
_ _ _ _ _ _ _ _ _ _
The choice is made as usual with the cursor and accepted when ready (which will store the chosen Title as the
default name). Backspace allows a correction to be made while ‘Return without change’ will leave the default
name unchanged.
Note: The ‘_’ symbols indicate where the title will appear - they do not appear on-screen
Enter New PIN
The PIN number for the supervisor is pre-programed but can be changed by the supervisor through the
following screen:
Enter new PIN _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Cancel
Key in the new PIN (password) and accept the entry.
Make a note of the new PIN number and keep it in a safe place
Privacy Zone Setup
The nal option on the Supervisor Menu allows specic areas within view of the camera to be blanked out,
preventing the operator from monitoring or storing the images from those areas. Before selecting the feature,
ensure that the camera is positioned so that the required area to be blocked is shown full screen on the
monitor. The feature then allows the following options:
Denesinglezone
Clear single zone
Denemultiplezones
Clear all privacy zones
Return
Exit
Selecting ‘Dene single zone’ will make the screen go black as the patch is inserted. As the dome has returned
to normal mode, out of the screen settings, move the camera view away from the area and the black section
will remain in its specic location.
When dening multiple zones the screen will go black and the text ‘Privacy zones’ will be displayed. Move the
camera to the desired area and press ‘Enter for each zone. When nished, use the key sequence to enter the
menu structure (e.g. * for DS2) to escape from the feature.
To clear a privacy zone, the camera must be positioned over the zone before selecting the ‘Clear’ facility or
the “Clear all privacy zones” feature selected. The dome will immediately return to normal operation after the
zone(s) has been deleted.
Dedicated Micros ©2009
16
2060
Technician Menu
The Technician menu provides access to a number of features to determine overall dome operating
congurations. This menu will be little used after the dome is rst installed and commissioned.
When called, it displays:
Camera set up
Enable/Disable options
Joystick control
Miscellaneous Services
Change PIN
Return
Exit
Camera set up
A number of changes can be made to the operation of the camera module inside the dome. The following
screen is used:
Camera color : col/mono
Preset focus: auto
Near focus: disabled
Frame integ: auto
HyperD: off
Save and Return
Save and Exit
The options are all set in the same way. To change the setting, move the cursor up/down until it is alongside
the feature. Moving the joystick to the left or right (or pressing the left/right direction arrows) will scroll through
alternative settings. Moving up or down will x the value on the screen.
When col/mono is selected the camera will operate in color mode until the light level falls below a
predetermined value when it will automatically switch to mono mode. The reverse will occur when the light
returns to a suitable level for color operation. The camera may also be xed in color or mono mode if preferred.
When a preset position is stored the focus position of the lens is also stored. If the preset focus is set to ‘auto’
(the preferred setting) the camera will re-focus itself to cope with any changing circumstances. Setting this to
manual will force the original focus setting onto the camera while it remains at the preset position.
The Near focus setting may be used in indoor applications as it allows the camera to focus at objects less than
three feet away. This should be disabled for normal outdoor operation as, otherwise, it will auto focus onto
raindrops that fall on the hemisphere.
If the frame integration is set to ‘auto’ the camera is able to adjust its frame rate to suit low light applications.
Alternately the shutter speed may be selected but the image quality may suffer in low light.
When HyperD mode is on the dynamic range of the camera is extended to provide better quality images in
high brightness/contrast scenes.
Note HyperD mode is not available on 18X colour mono camera.
Dedicated Micros ©2009
17
2060
Enable/Disable options
A number of settings are available to allow the Technician to reposition text and determine suitable action when
errors occur. Selecting this brings up the following screen:
Text edit : local
Head info disp: disabled
Head info just: left
Error display: enabled
Power fail: none
│
Save and Return
Save and Exit
The options are all set in the same way. To change the setting, move the cursor up/down until it is alongside
the feature. Moving the joystick to the left or right (or pressing the left/right direction arrows) will scroll through
alternative settings. Moving up or down will x the value on the screen.
The ‘Text edit’ option determines whether screen text will be edited locally, that is selected from the dome’s
own screen options; or whether it is compiled at the system Control Panel and transferred to the dome within
the Dedicated Micros serial protocol.
The ‘Head info’ option enables text to be displayed, in the top corner of the screen, indicating the current
conguration of the dome and information on some of its current actions. The display may be positioned at the
left or right of the screen.
‘Error display’ enables the ashing square to appear to indicate any communication errors.
‘Power fail’ determines what the dome should do if power is lost. When the power is restored, the dome can
either return to preset position number 1 or restart tour number 1. Selecting ‘none’ will result in the dome
remaining in its last position.
Joystick control
The dome may be controlled by a wide range of PTZ controllers and recorders with many different joystick
devices. To allow optimal use from the joystick a range of settings can be congured:
Divide by : 16
Linear speed: 5
Pan direction: default
Tilt direction: default
Horiz cursor: default
Vert cursor: default
Save and Return
Save and Exit
Joystick divide determines the relationship between the fast and slow joystick speeds where the control panel
is able to offer this feature. The selection determines the mathematical ratio between fast and slow speeds for
Pan and Tilt. Divide values between 2 and 128 are available.
The linear speed setting alters the speed at which the dome rotates and tilts. The range can be set from
1 (slowest) to 8 (fastest). It may be desired to reverse the direction of the joystick in relation to camera
movement or cursor positioning. These are all selectable from the screen.
Dedicated Micros ©2009
18
2060
Miscellaneous Services
This facility groups together a range of data and settings that may be useful to the technician in fault nding.
The following options become available:
Host comms/video amp
Software version
Homing values
Home servos
NVM Services
Reset Head
Return
Exit
Selecting ‘Software version’ will briey display the programed software revision level at the top of the screen.
Similarly, ‘Homing values’ will briey display encoder values from the pan and tilt motors.
‘Home servos’ will perform a motor reset where the dome will go into a routine where it pans and tilts through
its ranges to re-establish its base position.
‘Reset head’ provides a reboot to the dome. It will perform its power-on self test and then home its servos.
Host comms/video amp
Selecting this brings up the following screen:
Activity LED : Off
Host polling: On
Video gain: 2
Video lift: Off
Save and Return
Save and Exit
The small red LED in the dome can be switched on or off. This can be useful to check if power is reaching the
dome but it may be visible in low light conditions.
Host polling determines whether the dome responds to messages in half duplex serial communications, or acts
in simplex mode without answering. This will depend on the controller being used and the conguration of the
dome communications.
The video signal may require boost and lift to compensate for different types or lengths of coax. Video gain is
factory set at 1 with Video lift off and different settings are made in the usual way.
NVM Services
The dome retains data about its current position, stored presets and tours, along with other data which it
requires for normal operation, in a Non-Volatile Memory device or NVM. Any loss or corruption of this data will
prevent the unit from operating normally. The following checks on the device are available:
Reload Factory Defaults
Clear NVM Errors
Run NVM check
Return
Exit
NOTE: Reload factory defaults’ should not be used unless directed to do so by a trained technician. It will
reload all the default settings and delete all stored data such as preset positions, time and date etc.
Dedicated Micros ©2009
19
2060
Enter New PIN
The PIN number for the technician menu is pre-programed but can be changed by the technician through the
following screen:
Enter new PIN _ _ _
0 1 2 3 4 5 6 7 8 9
Accept Entry
Clear Entry
Cancel
Key in the new PIN (password) and accept the entry.
Make a note of the new PIN number and keep it in a safe place
Dedicated Micros ©2009
20
2060
Menu Flow Charts
Main Menu
Go to Preset .................................................. Preset Number
...................................................................... 0 1 2 3 4 5 6 7 8 9
...................................................................... Accept Entry
...................................................................... Clear Entry
...................................................................... Return
Start Tour ....................................................... Tour Number _ _ _
...................................................................... 0 1 2 3 4 5 6 7 8 9
...................................................................... Accept Entry
...................................................................... Clear Entry
...................................................................... Return
Technician Menu ...........................................Enter PIN _ _ _ _________________ To Technician Menu
...................................................................... 0 1 2 3 4 5 6 7 8 9
...................................................................... Accept Entry
...................................................................... Clear Entry
...................................................................... Return
Supervisor ..................................................... Enter PIN _ _ _ _________________ To Supervisor Menu
...................................................................... 0 1 2 3 4 5 6 7 8 9
...................................................................... Accept Entry
...................................................................... Clear Entry
...................................................................... Return
Exit
Technician Menu
Camera Setup ............................................... Camera color
...................................................................... Preset Focus
...................................................................... Near Focus
...................................................................... Frame integ
...................................................................... HyperD
...................................................................... Save and Return
...................................................................... Save and Exit
Enable/Disable options.................................. Text edit
...................................................................... Head info disp
...................................................................... Head info just
...................................................................... Error display
...................................................................... Power fail
...................................................................... Save and Return
...................................................................... Save and Exit
Joystick Controls ........................................... Divide by
...................................................................... Linear Speed
...................................................................... Pan Direction
...................................................................... Tilt direction
...................................................................... Horiz cursor
...................................................................... Vert cursor
...................................................................... Save and return
...................................................................... Save and Exit
Miscellaneous Services .................................Host comms/Video amp
...................................................................... Software version
...................................................................... Homing values __________________ Activity LED
...................................................................... ______________________________ Host Polling
...................................................................... ______________________________ Video gain
...................................................................... ______________________________ Video lift
...................................................................... ______________________________ Save and Return
...................................................................... ______________________________ Save and Exit
...................................................................... Home servos
...................................................................... NVM Services __________________ Reload Factory Defaults
...................................................................... ______________________________ Clear NVM Errors
...................................................................... ______________________________ Run NVM Check
...................................................................... ______________________________ Return
...................................................................... ______________________________ Exit
...................................................................... Reset Head
......................................................................
Change PIN ..................................................Enter New PIN
...................................................................... 0 1 2 3 4 5 6 7 8 9
...................................................................... Accept Entry
...................................................................... Clear Entry
...................................................................... Return without Change
Return
Exit
/