Revision History
Intel® Server System SR1630BC
Revision 1.3
Intel order number E44588-003
ii
Revision History
Date Revision
Number
Modifications
January 2009 1.0 Initial Release
March 2009 1.1 Updated system feature set table
April 2009 1.2 Updated Appendix B: POST Code Diagnostic LED Decoder according to BIOS
EPS.
Updated Appendix C: POST Error Messages and Handling according to BIOS
EPS.
Updated “System Status LED Indicator States Table”.
Removed AXXHERAL option from “Rack and Cabinet Mounting Options”
section.
Removed S4 state option from the “Power / Sleep LED” section.
Updated cable length in the “Cable Harness Definition” table.
May 2009 1.3 Updated memory description in “Table 1. System Feature Set”.
Disclaimers
Information in this document is provided in connection with Intel
®
products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make
changes to specifications and product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or
"undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or
incompatibilities arising from future changes to them.
This document contains information on products in the design phase of development. Do not finalize a design with
this information. Revised information will be published when the product is available. Verify with your local sales office
that you have the latest datasheet before finalizing a design.
The server boards / systems referenced in this document may contain design defects or errors known as errata which
may cause the product to deviate from published specifications. Current characterized errata are available on
request.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © Intel Corporation 2009. All rights reserved.
Intel® Server System SR1630BC Introduction
Revision 1.3
Intel order number E44588-003
1
Table of Contents
1. Introduction.............................................................................................................................5
1.1 Chapter Outline .........................................................................................................5
1.2 Server System Use Disclaimer................................................................................5
2. Product Overview....................................................................................................................6
2.1 System Views ...........................................................................................................8
2.2 System Dimensions ...................................................................................................8
2.3 System Components..................................................................................................9
2.4 Hard Drive and Peripheral Bays................................................................................11
2.5 Server Board Overview ...........................................................................................12
2.5.1 Server Board Connector and Component Layout..................................................13
2.5.2 Intel
®
Light-Guided Diagnostic LED Locations.......................................................14
2.5.3 Riser Card..............................................................................................................15
2.6 Rack and Cabinet Mounting Options .........................................................................15
3. Power Sub-System ................................................................................................................16
3.1 Mechanical Overview...............................................................................................16
3.2 Output Connectors ..................................................................................................18
3.2.1 P1 – Main Power Connector .....................................................................................18
3.2.2 P2 – Processor/DDR3 Power Connector ...................................................................18
3.2.3 P3 – Power Signal Connector ...................................................................................19
3.2.4 P4 and P5 – SATA Hard Drive Power Connectors......................................................19
3.2.5 P6 – Slim-line SATA Optical Disk Drive Power Connector...........................................20
3.3 Efficiency ................................................................................................................20
3.4 AC Input Voltage Requirement.................................................................................20
3.5 Protection Circuits...................................................................................................21
3.5.1 Over-current Protection (OCP) .................................................................................21
3.5.2 Over-voltage Protection (OVP).................................................................................21
3.5.3 Over-temperature Protection (OTP).........................................................................22
3.6 AC Power Cord Specification Requirements..............................................................22
4. Cooling Sub-System ...............................................................................................................23
4.1.1 System Fan Connectors ...........................................................................................24
Intel® Server System SR1630BC Introduction
Revision 1.3
Intel order number E44588-003
2
4.2 Power Supply Fans..................................................................................................25
4.3 Processor Air Duct and Air Baffle .............................................................................25
5. Peripheral and Hard Drive Support.........................................................................................26
5.1 Optical Drive Support...............................................................................................27
5.2 Hard Disk Drive Support ..........................................................................................27
6. Front Control Panel................................................................................................................28
6.1.1 Power / Sleep LED...................................................................................................29
6.1.2 System Status LED..................................................................................................29
6.1.3 Drive Activity LED ...................................................................................................30
7. PCI Riser Cards and Assembly ................................................................................................31
8. Environmental and Regulatory Specifications.........................................................................32
8.1 System Level Environmental Limits..........................................................................32
8.2 Serviceability and Availability...................................................................................32
8.3 Replacing the CMOS Battery ....................................................................................33
8.4 Product Regulatory Compliance ...............................................................................34
8.5 Use of Specified Regulated Components ..................................................................34
8.6 Electromagnetic Compatibility Notices .....................................................................37
8.6.1 USA ........................................................................................................................37
8.6.2 FCC Verification Statement......................................................................................38
8.6.3 ICES-003 (Canada)...................................................................................................38
8.6.4 Europe (CE Declaration of Conformity) .....................................................................38
8.6.5 Japan EMC Compatibility...........................................................................................38
8.6.6 BSMI (Taiwan) .........................................................................................................38
8.6.7 RRL (Korea).............................................................................................................39
8.6.8 CNCA (CCC-China) ....................................................................................................39
8.7 Product Ecology Compliance ....................................................................................39
8.8 Other Markings........................................................................................................42
Appendix A: Integration and Usage Tips .......................................................................................43
Appendix B: POST Code Diagnostic LED Decoder...........................................................................44
Appendix C: POST Error Messages and Handling ...........................................................................49
Glossary.......................................................................................................................................54
Reference Documents..................................................................................................................55
Intel® Server System SR1630BC Introduction
Revision 1.3
Intel order number E44588-003
3
List of Figures
Figure 1. Intel
®
Server System SR1630BC...................................................................................8
Figure 2. Major System Components – Intel
®
Server System SR1630BC ...................................9
Figure 3. Back Panel Features ...................................................................................................10
Figure 4. Drive Bays – Intel
®
Server System SR1630BC ...........................................................11
Figure 5. Intel
®
Server Board S5500BC picture..........................................................................12
Figure 6. Intel
®
Server Board S5500BC Layout..........................................................................13
Figure 7. Intel
®
Light-Guided Diagnostic LED Locations.............................................................14
Figure 8. Overview of power Supply...........................................................................................16
Figure 9. Power Supply Mechanical Drawing.............................................................................17
Figure 10. AC Power Cord Drawing............................................................................................22
Figure 11. Fan Module Assembly – Intel
®
Server System SR1630BC.......................................23
Figure 12. Air Duct for the Intel
®
Server System SR1630BC......................................................25
Figure 13. Peripheral Location....................................................................................................26
Figure 14. Front Control Panel – Intel
®
Server System SR1630BC............................................28
Figure 15. PCI Riser Card Assembly..........................................................................................31
Figure 16. Diagnostic LED Placement Diagram .........................................................................44
Intel® Server System SR1630BC Introduction
Revision 1.3
Intel order number E44588-003
4
List of Tables
Updated memory description in “Table 1. System Feature Set”................................................... ii
Table 2. System Feature Set........................................................................................................6
Table 3. Intel
®
Server System SR1630BC Dimensions................................................................8
Table 4. Board Layout reference ................................................................................................13
Table 5. Intel
®
Light-Guided Diagnostic LED reference..............................................................15
Table 6. Cable Harness Definition..............................................................................................18
Table 7. P1 – Main Power Connector Pin-out.............................................................................18
Table 8. P2 – Processor/DDR3 Power Connector Pin-out .........................................................19
Table 9. P3 –Power Signal Connector Pin-out............................................................................19
Table 10. P4 and P5 – SATA Hard Drive Power Connector Pin-out...........................................19
Table 11. P6 – Slim-line SATA Optical Disk Drive Power Connector Pin-out.............................20
Table 12. Power Supply Efficiency .............................................................................................20
Table 13. AC Input Rating...........................................................................................................20
Table 14. Over-current Protection (OCP) ...................................................................................21
Table 15. Over-Voltage Protection (OVP) Limits ........................................................................21
Table 16. Cooling Zones.............................................................................................................24
Table 17. System Fan Connector Pin-outs.................................................................................24
Table 18. Control Panel LED Functions......................................................................................28
Table 19. SSI Power LED Operation..........................................................................................29
Table 20. System Status LED Indicator States...........................................................................29
Table 21. System Environmental Limits Summary .....................................................................32
Table 22. System Maintenance Procedure Times......................................................................33
Table 23. Product Safety & Electromagnetic (EMC) Compliance...............................................35
Table 24. Product Ecology Compliance Reference Table..........................................................40
Table 25. POST Progress Code LED Example ..........................................................................44
Table 26. Diagnostic LED POST Code Decoder........................................................................45
Table 27. SEL Format for POST Error Messages ......................................................................49
Table 28. POST Error Messages and Handling..........................................................................49
Table 29. POST Error Beep Codes ............................................................................................52
Intel® Server System SR1630BC Introduction
Revision 1.3
Intel order number E44588-003
5
1. Introduction
This Technical Product Specification (TPS) provides system specific information detailing the
features, functionality, and high level architecture of the Intel
®
Server System SR1630BC. You
should also reference the Intel
®
Server Board S5500BC Technical Product Specification more
details regarding the functionality and architecture specific to the integrated server board and
what is supported in this server system.
The Intel
®
Server System SR1630BC may contain design defects or errors known as errata
which may cause the product to deviate from published specifications. Refer to the Intel
®
Server Board S5500BC/ Intel
®
Server System SR1630BC Specification Update for published
errata.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1 – Introduction
Chapter 2 – Product Overview
Chapter 3 – Power Sub-System
Chapter 4 – Cooling Sub-System
Chapter 5 – Peripheral and Drive Support
Chapter 6 – Front Control Panel
Chapter 7 – PCI Riser Card and Assembly
Chapter 8 – Environmental and Regulatory Specifications
Appendix A – Integration and Usage Tips
Appendix B – POST Code Diagnostic LED Decoder
Appendix C – Post Error Message and Handling
Glossary
Reference Documents
1.2 Server System Use Disclaimer
Intel
®
Server Systems support add-in peripherals and contain a number of high-density VLSI
and power delivery components that need adequate airflow to cool. Intel ensures through its
own chassis development and testing that when Intel server building blocks are used together,
the fully integrated system will meet the intended thermal requirements of supported
components. It is the responsibility of the system integrator who chooses not to use Intel
developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of air flow required for their specific application and environmental
conditions. Intel Corporation cannot be held responsible if components fail or the server system
does not operate correctly when used outside any of their published operating or non-operating
limits.
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
6
2. Product Overview
The Intel
®
Server System SR1630BC is a 1U server system designed to support the Intel
®
Server Board S5500BC. The server board and the system have features designed to support
the high-density server market. This chapter provides a high-level overview of the system
features. Greater detail for each major system component or feature is provided in the following
chapters.
Table 2. System Feature Set
Feature Description
Dimensions
• 1.7 inches (43.3 mm) high
• 16.9 inches (430 mm) wide
• 20 inches (508 mm) deep
• 22 pounds (10 kg) weight
Server Board Intel
®
Server Board S5500BC
Processor
LGA 1366 sockets supporting up to two Intel
®
Xeon
®
processor 5500 series with Intel
®
QuickPath Interconnect (QPI) and Integrated Memory controllers.
• Supports up to 95 W Thermal Design Power (TDP)
4.8 GT/s, 5.86 GT/s, and 6.4 GT/s Intel
®
QuickPath Interconnect (Intel
®
QPI)
EVRD11.1
For a complete list of supported processors, see:
http://support.intel.com/support/motherboards/server/s5500bc/compat.htm
Memory
Eight DDR3 DIMM slots supporting up to 32 GB of DDR3 800/166/1333 MT/s ECC Registered
(RDIMM), or ECC Unbuffered (UDIMM) DDR3 memory
• Four slots support CPU_1 and four slots support CPU_2.
NOTE: Mixed memory is not tested or supported. Non-ECC memory is not tested and is not
recommended for use in a server environment
Chipset
• Intel
®
I/O Hub (IOH) 5500 chipset
• Intel
®
82801Jx I/O Controller Hub 10 Raid (ICH10R)
• ServerEngines* LLC Pilot II BMC controller (Integrated BMC)
Peripheral Interfaces
External connections:
DB-15 video connector (back)
RJ-45 serial Port A connector
Two RJ-45 10/100/1000 Mb network connections
Four USB 2.0 connectors (back)
One USB 2.0 connector (front)
Internal connections:
Two USB 2x5 pin header, each supports two USB 2.0 ports
One DH-10 Serial Port B header
Six Serial ATA (SATA) II connectors
One SSI-EEB compliant front panel header
One SSI-EEB compliant 24-pin main power connector
One SSI-compliant 8-pin CPU power connector
One SSI-compliant 5-pin auxiliary power connector
One 4-Pin SGPIO connector
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
7
Feature Description
Add-in PCI, PCI
Express* Cards
Slot6 on server board supports one riser card supporting one half-length low-profile (6.6
inches) PCI Express* Gen2 x8 connector with X8 link width (support riser card)
Video
On-board ServerEngines* LLC Pilot II BMC controller
Integrated 2D video controller
64 MB DDR2 667 MHz Memory
LAN
Two 10/100/1000 NICs
One 82574LGbE PCI Express* Network Controller connects to the Gen2 x1
interface on the Intel
®
5500 IOH chipset.
One 82567 Gigabit Network Connection that connects to the Gigabit LAN Connect
Interface / LAN Connect Interface on the Intel
®
ICH10R
Two 10/100/1000 Base-TX Interfaces through RJ-45 connectors with integrated
magnetics.
Link and Speed LEDs on the RJ-45 Connector.
Expansion
Capabilities
One x8 PCI Express* Gen 2 PCI riser slot capable of supporting one low-profile half-length
PCI Express* add-in card which consumes power less than 15 W
Hard Drive Options
Fixed mount hard drive system: two SATA drives
Peripherals
• Slimline bay for slimline SATA optical drive
• One PCI Express* x8 Add-in Card slot (Gen 2)
Control Panel
• Standard control panel
LEDs and displays
LEDs with standard control panel:
NIC1 Activity
NIC2 Activity
Power / Sleep
System Status
Hard Drive Activity
Intel
®
Light-Guided diagnostic LEDs:
Fan Fault
DIMM Fault
CPU Fault
5V-STBY
System State
POST Code Diagnostics
Power Supply
Single 400-W power supply
Fans
Two 97 x 94 x 33 mm, non-redundant, variable-speed system blower fans
Two non-redundant 40 mm power supply internal fans
Server Management
On-board ServerEngines* LLC Pilot II Controller
Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0 compliant
Integrated Super I/O on LPC interface
Support for Intel
®
Server Management Software
System Management
Intel
®
System Management Software
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
8
2.1 System Views
Figure 1. Intel
®
Server System SR1630BC
2.2 System Dimensions
Table 3. Intel
®
Server System SR1630BC Dimensions
Height 1.7 inches
Width without rails 16.9 inches
Depth without CMA 20 inches
Maximum weight 22 pounds
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
9
2.3 System Components
A Rack handles (two) F CPU Heatsink (two)
B Processor air duct G System blower fans (two)
C System memory DIMM sockets H Hard drives (two)
D PCI add-in card bracket I Control panel
E Power supply J Slimline optical drive
Figure 2. Major System Components – Intel
®
Server System SR1630BC
Note: The I/O connector locations on the back of the chassis are pre-cut, making an I/O shield
unnecessary. You must install the supplied EMI gasket to maintain electromagnetic interference
(EMI) compliance levels.
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
10
A
AC Power Connector
E
NIC 2 Connector (10 / 100 / 1000 Mb) BMC
Management Port
B Serial Port A F USB Ports 6 and 7
C Video Connector G USB Ports 8 and 9
D NIC 1 Connector (10 / 100 / 1000 Mb) H PCI Express* Slot
Figure 3. Back Panel Features
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
11
2.4 Hard Drive and Peripheral Bays
The Intel
®
Server System SR1630BC is designed to support up to two fixed 3.5-inch Serial ATA
(SATA) hard drives and one slimline optical device.
A Slimline optical drive bay
B Hard drive bay HDD0 (located under the
slimline optical drive bay)
C Hard drive bay HDD1
Figure 4. Drive Bays – Intel
®
Server System SR1630BC
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
12
2.5 Server Board Overview
Figure 5. Intel
®
Server Board S5500BC picture
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
13
2.5.1 Server Board Connector and Component Layout
The following figure shows the board layout of the server board. Each connector and major
component is identified by a number or letter, and a description is below the figure.
Figure 6. Intel
®
Server Board S5500BC Layout
Table 4. Board Layout reference
Description Description
A SATA 3 B Internal dual port USB2.0 header
C SATA 5 D SATA 4
E Slot 3, PCI Express* x4 F Slot 4, PCI 32-bit/33 MHz
G Intel
®
RMM3 slot H Slot 5, PCI Express* x8
I Slot 6, PCI Express* x8 (Riser card) J Slot 7, PCI Express* x8
K Back panel I/O ports L Diagnostic LEDs
M Status LED N ID LED
O External Serial B header P SATA Key
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
14
Description Description
Q System fan 3 header R Main power connector
S DIMM sockets for Channel A & B (Supports CPU_1) T Power Supply Auxiliary Connector
U SSI 24-pin Front Panel connector V System fan 2 header
W CPU_1 fan header X CPU Power Connector
Y CPU_1 Socket Z Intel
®
IOH 5500 chipset
AA CPU Socket 2 BB CPU 2 fan header
CC System fan 1 header DD DIMM sockets for Channels D and E (Supports CPU_2)
EE SATA SGPIO FF SATA 0
GG SATA 1 HH SATA 2
2.5.2 Intel
®
Light-Guided Diagnostic LED Locations
Figure 7. Intel
®
Light-Guided Diagnostic LED Locations
Intel® Server System SR1630BC Product Overview
Revision 1.3
Intel order number E44588-003
15
Table 5. Intel
®
Light-Guided Diagnostic LED reference
Description Description
A Post-Code Diagnostic LEDs B Status LED
C System ID LED D HDD LED
E System Fan 3 Fault LED F 5 VSB LED
G DIMM Fault LED H System Fan 2 Fault LED
I CPU 1 Fan Fault LED J CPU 2 Fan Fault LED
K System Fan 1 Fault LED L DIMM Fault LED
2.5.3 Riser Card
The system supports one PCI riser card that has one PCI Express* Gen2 x8 connector with X8
link width that supports one half-length half-height (6.6 inches) riser card consuming 15 W or
less of power.
2.6 Rack and Cabinet Mounting Options
You can install the Intel
®
Server System SR1630BC in 19-inch wide by up to 30-inch deep
server cabinets. The system supports two rack mount options:
A fixed mount relay rack / cabinet mount kit that can be configured to mount the system
into either a 2-post or 4-post rack cabinet. (Product order code for the cabinet mount kit:
AXXBRACKETS.)
A basic slide rail kit designed to mount the chassis into a standard 19-inch by up to 30-
inch deep EIA-310D compatible server cabinet. (Product order code for the slide rail kit:
AXXBASICRAIL.)
Intel® Server System SR1630BC Power Sub-System
Revision 1.3
Intel order number E44588-003
16
3. Power Sub-System
The power sub-system consists of one, non-redundant high efficiency 400-W power supply that
supports a 1U rack mount server system. The power supply and the power supply sub-system
will have six outputs: 3.3 V, 5 V, 12 V1, 12V2, -12 V, and 5 VSB. The input is auto-ranging and
power factor corrected. The form factor is EPS1U at 240 mm depth and wire harness output. It
provides integrated management features, including over-temperature protection circuitry and
over-voltage protection circuitry.
The power supply provides two non-redundant 40 mm fans for self-cooling.
3.1 Mechanical Overview
Figure 8. Overview of power Supply
Intel® Server System SR1630BC Power Sub-System
Revision 1.3
Intel order number E44588-003
17
Figure 9. Power Supply Mechanical Drawing
Notes:
1. All dimensions are in mm.
2. The tolerance of the 40 mm height dimension (marked with letter C) pertains to the metal case
only.
Intel® Server System SR1630BC Power Sub-System
Revision 1.3
Intel order number E44588-003
18
3.2 Output Connectors
The power supply has a cable harness with five power connectors used to power various
platform sub-systems. The following table defines each power connector.
Table 6. Cable Harness Definition
Label Length (mm) Description
P1 380 Main Power Connector
P2 300 Processor/DDR3 Power Connector
P3 380 Power Signal Connector
P4 350 P4 SATA drive power connector
P5 145 P5 SATA drive power connector
P6 200 Slim SATA DVD power connector
3.2.1 P1 – Main Power Connector
Connector housing: 24-pin Molex* Mini-Fit Jr.
39-01-2245 (94V2) or equivalent
Contact: Molex* Mini-Fit Jr, Crimp 5558 or equivalent
Table 7. P1 – Main Power Connector Pin-out
Pin Signal 18 Awg Color Pin Signal 18 Awg Color
1 +3.3 VDC Orange 13 +3.3 VDC Orange
2 +3.3 VDC Orange 14 -12 VDC Blue
3 COM Black 15 COM Black
4 +5 VDC
1
Red 16 PSON# Green
5 COM Black 17 COM Black
6 +5 VDC Red 18 COM Black
7 COM Black 19 COM Black
8 PWR OK Gray 20 Reserved N.C.
9 5 VSB Purple 21 +5 VDC Red
10 +12 V Yellow/Black 22 +5 VDC Red
11 +12 V Yellow/Black 23 +5 VDC Red
12 +3.3 VDC Orange 24 COM Black
Notes:
1. 5V Remote Sense double-crimped into pin 4.
3.2.2 P2 – Processor/DDR3 Power Connector
Connector housing: 8-pin Molex* 39-01-2085 (94V2) or equivalent
Contact: Molex*, Mini-Fit
Jr, HCS, 44476-1111 or equivalent
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Intel SR1630BC - Server System - 0 MB RAM Specification

Category
Server barebones
Type
Specification
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI