Optimus GT-TLIIP User manual

  • Hello! I am an AI chatbot trained to assist you with the Optimus GT-TLIIP User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
GB358IP-1 -06.09.18– Edition notice V1.0
GTTLIIP
200290
VoIP INTERFACE
FOR GT SYSTEM
INSTALLATION MANUAL
2 06.09.18 – V1.0
General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions
Negligence
could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric
schock could result.
2. Do not connect non-specified power source to the + & -
terminals. Also do not install two power supplies in parallel to
a single input. Fire, damage or electric schock could result.
3. Keep the unit away from water or any other liquid. Fire
or electric schock could result.
4. Do not put any metal or paper into the unit through the
openings. Fire, electric schock or unit trouble could result.
5. Inside of unit is subjected of current. Don’t touch any
pieces other than the points of assembly, cabling, connection
and adjustments. Fire or electric schock could result.
6. Do not use power supply with different voltage that
prescribed. Fire or electric schock could result.
7. Do not connect any terminal on the unit to an AC power
line. Fire or electric schock could result.
8. Do not remove the power supply plug with wet hands.
Electric schock could result.
Negligence could result in injury to people or damage to
property.
1. Do not install or make any wire terminations while the
power supply is turned on. This can cause electrical schock or
damage to the unit.
2. Before turning the power, make sure wires are not
crossed or shorted. If not, fire or electric schock could result.
3. When mounting the unit on a wall, install the unit in a
convenient location, but not where it could be jarred or
bumped. Injury could result.
4. For power supply, use Aiphone power supply model or
model specified for use with system. If non specified product is
used, fire or malfunction could result.
The block power supply is the system of cuting power of
equipment. It must be accessible.
5. Do not install the unit in any of the following locations.
Fire, electric schock or unit trouble could result.
* Places under direct sunlight or places near heating
equipment that varies in temperature.
* Places subject to dust, oil, chemical, etc
* Places subject to moisture and humidity extremes such as
bathrooms, cellars, greenhouses, etc.
* Places where temperature is quite low such as inside a
refrigerated area or in front of an air conditioner.
* Places subject ta steam or smoke (near heating or
coocking surfaces).
* Where noise generating devices such as dimmer switches
or inverter electrical appliances are close by.
6. Put nothing on the unit and do not cover it with a dust, etc. Fire
or malfunction could result.
7. Execute a test of call.
8. Do not place (install) the unit in locations subject to frequent
vibration or impact. Injury or damage could result if the unit falls.
9. This unit must be installed and wired by a qualified technician.
1. This unit is designed for indoor use only. Do not use outdoors.
2. In areas where broadcasting station antennas are closed by, system
may be affected by radio frequency interference.
3. The use of mobile phone nearby unit risks to cause malfunction.
4. Keep the unit more than 1m away from radio or TV set.
5 Damage could result if the unit falls. Handle with care.
6 The unit turns inoperative during power failure.
7 This product, supplying an electric striking plate, must not be used as
device of prevention of the crime.
8 Due to the environmental sound of the unit, it may hinder smooth
communication, but this is not a unit malfunction.
* We will under never conditions be liable for damage
consecutive to breakdowns of the network equipment; breakdowns
consecutive to internet access providers and companies of telephone ;
breakdowns such as disconnected lines or other losses of
communication, which would make impossible the supply of this
service or in no way delays of this service due to causes outside our
responsibility ; or in the eventuality of erroneous or missing data during
transmission.
* We will under never conditions be liable for damage that occurs due
to inability to communicate due to malfunctions, problems or
operationnal errors in this product..
* We will under never conditions be liable for damage that occurs due
to loss of user’s password or from transmitted informations causing
bugs or illegal access to the computer via Internet communications.
* We will under never conditions be liable for for any damages or
losses resulting from this product’s contents or specifications.
* Please note that images and illustrations depicted in this manual may
differ from actual product.
* Please note that this manual may be revised or changed without prior
notice.
* Please note product specifications may be changed for the sake of
improvement without prior notice.
* Please be aware of the fact that it is the responsibility of the user to
make sure that the computer is safe. We will under never conditions be
liable for any security defaults.
* This system is not intended for life support or crime prevention. It is
a supplementary means of conveying information. Aiphone will under
no conditions be liable for loss of life or property which occurs while
the system is being operated.
* To obtain a good functioning of the device, it is essential to have a
bandwidth of the data not less than 500kbps.
* Audio and video quality for smartphone is dependent on the network.
* The user will have to verify that e-mails from the server AiphoneGT
are not blocked or define as spam.
3 06.09.18 – V1.0
[1] [2] [3]
[4] [5]
Package contents :
[1] Installation manual [2] User manual
[3] GTTLIIP cabinet [4] Power supply [5] Fast installation manual
GTTLIIP can be installed:
- on desktop or
- wall mounted (use for example two screws type M3,5).
GTTLIP must be installed as far as possible from humidity or heating source.
4 06.09.18 – V1.0
State lighting
State
lighting
State
GT
TLIIP
Led green fixed
During initialization
1 flash per second
Correct functioning
3 flashes per second GTTLIIP did not find an IP address (DHCP did not work).
GT
TLIIP started with an address 192.168.0.100
4 flashes per second
GTTLIIP
has no connection with proxy
server
5 flashes per second
GTTLIIP
is not registered on SIP
server
ON :
POWER ON
OFF :
POWER
OFF
5 06.09.18 – V1.0
1 – GTTLIIP wiring
6 06.09.18 – V1.0
Connections Panel function:
- LAN: Ethernet port,
- External Power supply 12VDC +/- 10% linear regulated: position + (12VDC), - (0V).
(Consumption: 380mA in work, installed not far from 3 meters from GTTLIIP).
- Connection with bus on :
- R1-R2 : audio cable,
- B1-B2 : vidéo cable.
- 3 relays on GTTLIIP on REL1, REL2 & REL3:
- normally open (NO) on NO,
- common on C,
- normally closed (NC) on NC.
Relay Contact Ratings: 2 Amp/12VDC - 1Amp/24VDC. Maximum tension: 24VDC.
- Alarm function.
- plug contact on S1 & S1E.
7 06.09.18 – V1.0
Connecting GTTLIIP system
Several type of installation are available for GTTLIIP.
2 – Physical connection
2.1- Behind a modem router usually called Box by Internet provider like livebox, freebox, …
Connect GTTLIIP directly on the LAN/Ethernet plug of the modem router with Ethernet straight cable
(not supplied).
8 06.09.18 – V1.0
If there is no more LAN/Ethernet port available on your equipment, you will have to add a Switch
10/100Mbits/s (multiport Ethernet).
.
9 06.09.18 – V1.0
2.2- Modem without router function:
Use an Ethernet router 10/100 Mbits/s with several Ethernet port to your installation.
2.3 Configuration of GTTLIIP on GT system :
With GTDMBLVN panel : Adressage de l’interface par apprentissage
1 : Make sure that all the posts were cabled then to switch on your system
2 : Enter the numbers and the names for apartments with the keypad of your panel or with the tool of
configuration GT for Windows (enable on Aiphone.fr)
.
3 : When the panel is in sleep mode, dial # and then the administrator identification code (by default =
1111). Dial again the identification code.
4 : Use arrows high / low and scroll until PROGRAMMING. Press the button (bell) twice to
enter in programming mode. The led « IN USE » flash, then remains lit fixed. The panel is in
programming mode.
The LCD screen shows «CONNEXION» when panel is in programming mode.
5 : Make sure that button ON/OFF of GTTLIP is On. Then make impulse on button GT PROG, your
interface is in connection with your panel.
6 : Return to your panel then scroll until the number of post to be programmed or enter manualy the
number with the keypad. When the number of the resident post as well as its name displays, make an
impulse on the bell button to attribute the address to your interface which is active. A short beep
will be emitted.
10 06.09.18 – V1.0
Attention if you stay pressed on the bell button, a long beep will be emitted and your interface
will not be programmed.
Ne maintenez pas appuyé le bouton de la sonnette sous peine d’effacer la mémoire pour ce
numéro. (Bip long)
7 : Return to your interface to press on again the button GT PROG so that your interface gets out of
the programming mode.
8 : Repeat points 5 to 7 for the other interfaces.
9 : To quit programming for panel, push twice on key «X» on keypad to return to the main menu (the
LED « IN USE » turns off). Scroll until QUITTER and push the bell button . Your interface is
now recognized on your installation.
10 : Go to the paragraph: fast activation of GTTLIIP.
2.4 Fast activation of GTTLIIP :
After checking the connections, switch on all the items of the installation. GTTLIIP connects via a
server. After 30s, GTTLIIP will be registred on the server, the state led will blink green/orange every
seconds. Your interface is operational.
Activate your Smartphone application. As soon as your Smartphone will be registred on the server,
you can use your system.
3 – Smartphones settings:
It is very easy and convenient to register Smartphone by using the barcodes delivered with GTTLIIP.
Check if the application ‘Barcode Reader’ is available on the Smartphone. If not, it is necessary to
install one (ie Barcode Scanner):
1- Install application ‘AiphoneGT’ .
a. Read the Barcode available on the back of GTTLIIP or on the manual. Smartphone will
connect directly on the corresponding store depending of the Smartphone (Androïd or
IOS).
b. If the Barcode does not work, go to the relevant store corresponding to your Smartphone
and search the application ‘AiphoneGT’
11 06.09.18 – V1.0
2- Launch the application ‘AiphoneGT’
The welcome screen opens.
3- Automatic entry
4- Manual entry
User name : GT180000_1 to GT140801_5
Password : specified on Fast installation
manual
Domain : sipgt.tliip.com
And click on ‘Apply’
When the icon becomes green, your application is operational. You can launch a call by pressing the
call button of the panel.
12 06.09.18 – V1.0
4 – Advanced settings on GTTLIIP:
Allows to indicate one or several e-mail addresses to receive photos further to a call of the panel.
Allows to program relays and call settings.
Launch your web browser (Internet Explorer, Firefox, …) and in the address field of browser, enter
‘http://gt.tliip.com’. The PC is going to connect to the proxy, the following window appears:
Enter the serial number of the device (GT------ which is behind the device) in ‘User’ field and then
click the button ‘Connect’.
The following window appears.
Enter the password of GTTLIIP, specified on the sheet “fast installation” delivered with GTTLIIP.
13 06.09.18 – V1.0
The welcome screen of GTTLIIP appears:
The screen displays information onto the state of the connections with the proxy and with the server
Astérisk.
4.1-E-mail address programming (Click on ‘Resident’)
To enter an E-mail address to receive photo during a call, click on ‘Resident’.
If you select ‘Always’ an E-mail will be sent at each call.
If you don’t select ‘Always’ an E-mail will be sent only when your smartphone will be in white zone
(without GSM network).
Click on ‘Submit’ to validate your modifications.
14 06.09.18 – V1.0
To modify the parameters for relays of GTTLIIP, click Timing’. The following page appears:
4.2-Programming of operating parameters (Click on Timing)
This window allows the programming of parameters for relays and calls.
When the user confirms the option 'Terminate Call on Contact', the communication will end after the
opening of the door.
If the option 'Terminate Call on Contact + 5sec' is validated, the communication will end 5s after the
of opening of door.
15 06.09.18 – V1.0
• Operating temperature: 0°C - 40°C (32°F – 104°F).
• Cleaning: use a soft duster with neutral detergent. Do not use cleaner or duster abrasive.
• Dimensions : 9,5 x 7,1 x 2,17 (h) inch.
• Weight : 0,4 pounds
Connections : (1) Ethernet Network
(2) GT Bus
Smartphones : Using Androïd© or Apple© operating system. Not yet available under
Windows©
Power supply : 12V DC – 0,5A
Consumption: Stand-by 350mA, when relay is on 430mA.
Standards : EN60950
EN55032 Edition 2015 Classe B
EN55024 Edition 2010 Classe B
Exit Contact: 3 (Normally Opened, Normally Closed)
Programming : Via Internet.
Saving of parameters : No volatile memory
Material : ABS cabinet
SECURITY
- Power supply (+ - 12 VDC) : TBTS (standard EN 60950) 12 Volts DC by connection to the block
power 220 Volts / 12 Volts CE (standard EN 60950) provided.
- Network connection (LAN) : intended to be connected with the network Ethernet
subjected to tensions of type TBTS (standard EN 60950).
- Connection GT R1-R2 (audio) and B1-B2 (vidéo) : intended to be connected to GT equipment
(tensions type TBTS according to standard EN 60950).
- Dry contacts outputs (NO C NC) : 3 wires for each contact (tensions type TBTS according to
standard EN 60950). Three contacts available.
SYMBOLS MEAN
: product answers the essential requirements of safety fixed by European directives
: The device must not be thrown with the garbage because containing toxic products or
recyclable elements
: This unit is designed for indoor use only.
: direct voltage.
16 06.09.18 – V1.0
Photos and descriptions not contractual
Distributed by AIPHONE
Printed in France
/