Related Documents
•EnterasysD2HardwareInstallationGuide
•EnterasysD2CLIReference
DocumentationURL:http://www.enterasys.com/support/manuals
Warranty Information
ForinformationontheD2LimitedLifetimeWarranty,goto:
http://www.enterasys.com/products/security‐enabled‐infrastructure/
warranties/warranty.aspx
Switch Setup
UsethisQuickReferencetosetuptheEnterasysD2switchasa
freestandingunit.RefertotheEnterasysD2HardwareInstallation
Guideforproceduresonmountingtheswitchintoarack,ona
wall,orunderatable.
Handling the Switch
Topreventelectrostaticdamage,attachanESDwriststraptoyour
wristbeforehandlingtheD2switch.
Switch Components
AsshowninFigure 1andFigure 2,portsandpowersupply
receptaclesarelocatedontherearpaneloftheD2switch.Port,
CPU,andpowerLEDsarevisiblefromthefront,top,andrear
panelsoftheswitch.
Figure 1 D2 Switch (rear view) shown without optional enclosure
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Note: Unless otherwise noted, the procedures in this document apply to all
D2 switches.
1Fan
2Power Supply 1 non-PoE receptacle (PWR1-A)
3Power Supply 2 non-PoE receptacle (PWR2-A)
4Console port (RJ45)
5Reset button
6Power Supply 2 (PWR2) LED
7RJ45 ports (1-12)
8SFP combo ports (11 and 12)
9RJ45 Port LEDs
10 Power Supply 1 (PWR1) LED
11 CPU (system) LED
12 Power Supply 2 PoE receptacle (PWR2-B)
13 Power Supply 1 PoE receptacle (PWR1-B)
Figure 2 D2 (top and front views) shown without optional enclosure
Connecting Power to the Switch
Youcanconnecttoasingle,primarysourceofpower,ortotwo
sourcesofpowerforredundancy.Theexampleusedhere
describesconnectingtotwopowersources.
Thefollowingredundantpowersuppliesareavailabletobe
purchasedfromEnterasysforconnectiontotheD2switch:
•D2‐PWR,aDCpowersupplycapableofprovidingpowertoa
fully‐loadednon‐PoEswitch
•D2‐PWR‐POE,aDCpowersupplyrecommendedforPoE
powerredundancy
1. PlugtheDCpowercordfromeachpowersupplyintoeachof
theswitchDCpowerreceptaclesthatareappropriateforyour
typeofpowersupplies.
•FortheD2‐PWRsupply,plugintothePWR1‐Aand
PWR2‐Areceptacles
•FortheD2‐PWR‐POEsupply,plugintothePWR1‐Band
PWR2‐Breceptacles
2. PlugeachACcordintoitspowersupply’sACreceptacle.
3. PlugeachACcordintoadedicated,groundedACoutlet.
4. VerifythattheappropriatepowerLEDs(PWR1andPWR2)
turngreen,andtheCPU(system)LEDturnsamberuntilthe
D2finishesitsinitialization.TheseLEDsarevisiblefromthe
backoftheswitchasshowninFigure 1,aswellasfromthetop
andfrontoftheswitch,asshowninFigure 2.
Iftheinitializationprocessissuccessful,theCPULEDturnsgreen.
IftheCPULEDdoesnotturngreen,refertotheEnterasysD2
HardwareInstallationGuidefortroubleshootinginformation.
Fan Operation
TheD2fanwillturnonwhenpowerisfirstsuppliedtotheswitch
andwillshutoffautomaticallywhenthetemperaturefallsbelow
thefollowingswitchthresholds:
• D2G124‐12‐40degreesC(104degreesF)
• D2G124‐12P‐35degreesC(95degreesF)
1CPU (system) LED
2Power supply (PWR1 and PWR2) LEDs
3RJ45 port LEDs (ports 1-12)
4SFP combo port LEDs (ports 11 and 12)
Notes: The D2-PWR supply will power either the D2G124-12 or the
D2G124-12P without PoE support. The D2-PWR-POE is the only supply
needed to power the D2G124-12P with PoE support.
Both power supplies must be of the same type to support redundancy.
Note: To take advantage of redundancy capabilities, each power cord must
be plugged into a separate, dedicated AC outlet.
Completing the Setup and Downloading the Latest
Firmware
OnceyouhaveconnectedpowertotheD2switchandverified
LEDactivity,youcancompletethesetupprocessasfollows.Refer
totheEnterasysD2HardwareInstallationGuideformore
information.
1. DeterminethelatestD2firmwareversionbyvisitingthe
Enterasysdownloadsiteat:
http://secure.enterasys.com/services/support/downloads/software
2. Connecttheswitchtothenetwork.
3. Connectamangementstationtotheconsoleport.
4. Verifythatthenetworkdevicesconnectedtotheswitchports
arepoweredon,andthateachlink/activityLEDison(solid
greenorblinkinggreen).
5. Atthedeviceconnectedtotheconsoleport,performthe
following:
a. EnteradminforUsername.
b. AtthePasswordprompt,pressENTER(RETURN).
c. Atthecommandprompt,determineifthelatestfirmware
imageisloadedontheswitchbyenteringthiscommand:
show version
d.Iftheoutput(underFWVer s i o n )displaysanolderversion
numberthanthatdeterminedinStep1,downloadand
activatethenewversionasdirectedonthedownloadwebsite.
(Alternatively,youcanusetheCLIcommandlistedin
Table 1.)
e. RefertoTable 1andTable 2foralistofbasicCLIsetup
commands.
Basic Setup Commands
Table 1listsCLIcommandsthatarerequiredforsettinguptheD2
switchwiththelatestfirmware.Table 2listsoptionalCLI
commandsthatwillhelpyouperformadditionalbasic
configurationontheD2switch.RefertotheEnterasysD2CLI
Referenceformoreinformation.
Note: Once you are logged in to the D2 switch, it is recommended that
you check the version of firmware running on the switch and, if necessary,
download the latest version.
Table 1 Required CLI Setup Commands
Step Ta sk CLI commands
1Set a new password set password [username]
2Set the switch IP address set ip address ip-address [mask
ip-mask] [gateway ip-gateway]
3Download, activate, and
verify new firmware on the
switch using TFTP copy.
copy
tftp://tftp_server_ip_address/
filename system:image
set boot system filename
show version
Table 2 Optional CLI Setup Commands
Task CLI commands
Save the active configuration save config
Enable or disable SSH set ssh enable | disable
Enable or disable Telnet set telnet {enable | disable}
[inbound | outbound | all]
Enable or disable HTTP
management (WebView)
set webview {enable | disable}
Enable or disable SNMP port link
traps
set port trap port-string
{enable | disable}
Set the per port broadcast limit set port broadcast port-string
threshold-value
Configure a VLAN set vlan create vlan-id
set port vlan port-string
vlan-id modify-egress
Set a Syslog server IP and severity set logging server index ip-addr
ip-addr severity severity state
enable
Downloading Policy QuickStart
PolicyQuickStartprovidesaneasymethodtogetstartedapplying
port‐levelsecurityandperformancesettingstoEnterasysʹ
policy‐enabledswitchesforasetofpre‐definedbusinessroles.
Forexample,youcaneasilydesignatespecificportsforguest
userswheretheywillonlybeabletoobtainanIPaddressand
accessthewebandatalowerqualityofservicethanyouprovide
toyourenterpriseusers.TodownloadPolicyQuickStartgoto:
http://secure.enterasys.com/services/support/downloads/software
Formoreadvancedcontrol,includingcreationofcustombusiness
roles,EnterasysprovidesNetSightPolicyManager.
Switch Specifications
Interfaces
12RJ451000BASE‐TXports
Twocombo1000Base‐SX,1000Base‐LX,or100Base‐FXSFPports
Dimensions
D2G124-12
Size:4.1Hx21Wx21D(cm)/1.6Hx8.25Wx8.5D(in.)
Weight(withoutpowersupply):3.65lb/1.66kg
D2G124-12P
Size:4.1Hx21Wx21D(cm)/1.6Hx8.25Wx8.5D(in.)
Weight(withoutpowersupply):4.02lb/1.82kg
Power Consumption and Mean Time Between Failure (MTBF)
D2G124-12
Power:30W/102.39(BTUs/hr)
MTBF:196,559hrs
D2G124-12P
Power:130W/443.69(BTUs/hr)
MTBF:144,035hrs
Temperature and Humidity
Operating: D2G124‐12‐0°Cto60°C(32°Fto140°F)
D2G124‐12P‐0°Cto50°C(32°Fto122°F)
Storage: ‐40°to70°C(‐40°to158°F)
Operatingrelativehumidity:5%to95%(non‐condensing)
Getting Help
Configure and enable a RADIUS
server.
set radius server index ip-addr
port [secret-value]{realm
{management-access | any |
network-access}
set radius enable
Configure and enable first arrival
MAC locking on user ports.
set maclock firstarrival
port-string value
set maclock enable port-string
Notes: Each combo SFP port on the D2 switch supports the installation of
Mini-GBICs for 1000Base-SX, 1000Base-LX, or 100Base-FX SFP
transceivers.
Each combo SFP port in use on the switch eliminates the availability of one
RJ45 port. In other words, only 12 ports can be active at any given time.
When an SFP transceiver (Mini-GBIC) SFP port 11 establishes a link, RJ45
port 11 is disabled. When an SFP transceiver (Mini-GBIC) in SFP port 12
establishes a link, RJ45 port 12 is disabled.
World Wide Web www.enterasys.com/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
To expedite your message, type [Switching] in the
subject field of your message.
Latest image and
release notes
www.enterasys.com/support/downloads/
Documentation www.enterasys.com/support/manuals/
Table 2 Optional CLI Setup Commands (Continued)
Task CLI commands