Enterasys Networks G3G124-24 User manual

Category
Network switches
Type
User manual

This manual is also suitable for

8.5x11-inch cover with bleed on 4 sides
Enterasys
®
G-Series
Ethernet Switch
G3G124-24
G3G124-24P
G3G170-24
Hardware Installation Guide
P/N 9034357-02
i
Notice
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentand
itswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networkstodeterminewhetheranysuch
changeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubject
tochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISINGOUTOF
ORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVENIF
ENTERASYS NETWORKSHASBEENADVISEDOF,KNEW
OF,ORSHOULDHAVEKNOWNOF,THEPOSSIBILITYOF
SUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
©2008Enterasys Networks, Inc.Allrightsreserved.
PartNumber: 903435702 April 2008
ENTERASYS,ENTERASYS NETWORKS,ENTERASYSMATRIX,ENTERASYSNETSIGHT,LANVIEW,WEBVIEW,andany
logosassociatedtherewith,aretrademarksorregisteredtrademarksofEnterasys Networks, Inc.,intheUnitedStatesandother
countries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespectivecompanies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal
vorgenommen werden.
ii
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynot
causeharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
NOTE: Thisequipmenthasbeentestedandfoundtocomply
withthelimitsforaclassAdigitaldevice,pursuanttoPart15of
theFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentis
operatedinacommercialenvironment.Thisequipmentuses,generates,andcanradiateradiofrequencyenergyandifnot
installedinaccordancewiththeoperatorsmanual,maycauseharmfulinterferencetoradiocommunications.Operationofthis
equipmentinaresidentialareaislikelytocauseinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterference
athisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhich
arenotexpresslyapprovedbythepartyresponsiblefor
compliancecouldvoidtheusersauthoritytooperatetheequipment.
Industry Canada Notice
ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissionsfromdigitalapparatussetoutintheRadio
InterferenceRegulationsoftheCanadianDepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruitsradioélectriquesdépassantleslimitesapplicablesauxappareils
numériquesdelaclassAprescrites
dansleRèglementsurlebrouillageradioélectriqueédictéparleministèredes
CommunicationsduCanada.
Class A ITE Notice
WARNING: ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasethe
usermayberequiredtotakeadequatemeasures.
Clase A. Aviso de ITE
ADVERTENCIA:EsteesunproductodeClaseA.Enunambientedomésticoesteproductopuedecausarinterferenciaderadio
encuyocasopuedeserrequeridotomarmedidasadecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS:DiesesProduktzähltzurKlasseA(Industriebereich).InWohnbereichenkanneshierdurchzu
Funkstörungenkommen,dahersolltenangemesseneVorkehrungenzumSchutzgetroffenwerden.
Product Safety
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,2006/95/EC,EN60950,IEC60950,EN 60825,
21 CFR 1040.10.
Seguridad del Producto
ElproductodeEnterasyscumpleconlosiguiente:UL60950,CSAC22.2No.60950,2006/95/EC,EN 60950,IEC 60950,EN 60825,
21 CFR1040.10.
Produktsicherheit
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,2006/95/EC,EN60950,IEC60950,
EN 60825,21CFR1040.10.
iii
Electromagnetic Compatibility (EMC)
Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,2004/108/EC,EN55022,EN6100032,
EN 6100033,EN55024,AS/NZSCISPR22,VCCIV3.
Compatibilidad Electromágnetica (EMC)
EsteproductodeEnterasyscumpleconlosiguiente:47CFRPartes2y15,CSAC108.8,2004/108/EC,EN55022,EN 55024,
EN 6100032,EN6100033,AS/NZSCISPR22,VCCIV3.
Elektro- magnetische Kompatibilität ( EMC )
DiesesProduktentsprichtdenfolgendenRichtlinien:47CFRParts2and15,CSAC108.8,2004/108/EC,EN55022,EN 6100032,
EN6100033,EN55024,AS/NZSCISPR22,VCCIV3.
Hazardous Substances
ThisproductcomplieswiththerequirementsofEuropeanDirective,2002/95/EC,RestrictionofHazardousSubstances(RoHS)
inElectricalandElectronicEquipment.
European Waste Electrical and Electronic Equipment (WEEE) Notice
InaccordancewithDirective2002/96/ECoftheEuropeanParliamentonwasteelectricalandelectronicequipment(WEEE):
1. Thesymbolaboveindicatesthatseparatecollectionofelectricalandelectronicequipmentisrequiredandthatthisproduct
wasplacedontheEuropeanmarketafterAugust13,2005,thedateofenforcementforDirective2002/96/EC.
2. When
thisproducthasreachedtheendofitsserviceablelife,itcannotbedisposedofasunsortedmunicipalwaste.Itmust
becollectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthattherearepotentialnegativeeffectsontheenvironmentandhuman
healthasaresultofthe
presenceofhazardoussubstancesinelectricalandelectronicequipment.
4. Itistheusers’responsibilitytoutilizetheavailablecollectionsystemtoensureWEEEisproperlytreated.
Forinformationabouttheavailablecollectionsystem,pleasegotowww.enterasys.com/support/ orcontactEnterasys
CustomerSupportat35361705586(Ireland).
iv
ѻ
ѻક䇈ᯢк䰘ӊ
Supplement to Product Instructions
᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance)
䚼ӊৡ⿄
(Parts)
䪙
3E
∲
+J
䬝
&G
݁Ӌ䫀
&U

໮⒈㘨㣃
3%%
໮⒈Ѡ㣃䝮
3%'(
䞥ሲ䚼ӊ
(Metal Parts)
ƻ ƻ ƻ ƻ
⬉䏃῵ഫ
(Circuit Modules)
ƻ ƻ ƻ ƻ
⬉㓚ঞ⬉㓚㒘ӊ
(Cables & Cable Assemblies)
ƻ ƻ ƻ ƻ
ล᭭੠㘮ড়⠽䚼ӊ
(Plastic and Polymeric parts)
ƻƻ ƻ ƻ ƻ ƻ
⬉䏃ᓔ݇
(Circuit Breakers)
ƻƻ ƻ ƻ ƻ ƻ
ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼ SJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎSJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎
߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ⊼ᛣ೼᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ৿᳝᠔᳝᠔߫ⱘ䚼ӊDŽ
This table shows where these substances may be found in the supply chain of Enterasys’ electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
䰸䴲঺໪⡍߿ⱘᷛ⊼ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ
᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞ
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
20
v
VCCI Notice
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnology
Equipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.Whensuchtrouble
occurs,theusermayberequiredtotakecorrectiveactions.
BSMI EMC Statement — Taiwan
ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheusermaybe
requiredtotakeadequatemeasures.
Safety Information
Class 1 Laser Transceivers
The single mode interface modules use Class 1 laser transceivers.
Read the following safety information before installing or operating these modules.
TheClass1lasertransceiversuseanopticalfeedbacklooptomaintainClass1operationlimits.Thiscontrolloopeliminatesthe
needformaintenancechecksoradjustments.Theoutputisfactoryset,anddoesnotallowanyuseradjustment.Class1Laser
transceiverscomplywiththefollowingsafetystandards:
•21
CFR1040.10and1040.11U.S.DepartmentofHealthandHumanServices(FDA).
•IECPublication825(InternationalElectrotechnicalCommission).
CENELECEN60825(EuropeanCommitteeforElectrotechnicalStandardization).
Whenoperatingwithintheirperformancelimitations,lasertransceiveroutputmeetstheClass1accessibleemissionlimitofall
threestandards.Class1levelsoflaserradiation
arenotconsideredhazardous.
Whentheconnectorisinplace,alllaserradiationremainswithinthefiber.Themaximumamountofradiantpowerexitingthe
fiber(undernormalconditions)is‐12.6dBmor55x10
6
watts.
Removingtheopticalconnectorfromthetransceiverallowslaserradiationtoemitdirectlyfromtheopticalport.Themaximum
radiancefromtheopticalport(underworstcaseconditions)is0.8Wcm
2
or8x10
3
Wm
2
sr1.
Donotuseopticalinstrumentstoviewthelaseroutput.Theuseofopticalinstrumentstoviewlaseroutputincreaseseye
hazard.Whenviewingtheoutputopticalport,powermustberemovedfromthenetworkadapter.
vi
Declaration of Conformity
ApplicationofCouncilDirective(s): 2004/108/EC
2006/95/EC
ManufacturersName: Enterasys Networks, Inc.
ManufacturersAddress: 50MinutemanRoad
Andover,MA01810
USA
EuropeanRepresentativeAddress: Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ConformancetoDirective(s)/ProductStandards: ECDirective2004/108/EC
EN55022
EN6100032
EN6100033
EN55024
ECDirective2006/95/EC
EN60950
EN60825
Equipment
Type/Environment: NetworkingEquipment,foruseinaCommercial
orLightIndustrialEnvironment.
Enterasys Networks, Inc.declaresthattheequipmentpackagedwiththisnoticeconformstotheabovedirectives.
Enterasys Networks, Inc. Firmware License Agreement
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
Thisdocumentisanagreement(“Agreement”)betweentheenduser(“You”)andEnterasysNetworks,Inc.,onbehalfofitself
anditsAffiliates(ashereinafterdefined)(“Enterasys”)thatsetsforthYourrightsandobligationswithrespecttotheEnterasys
softwareprogram/firmware(includinganyaccompanyingdocumentation,hardwareormedia)(“Program”)inthepackage
andprevailsoveranyadditional,conflictingorinconsistenttermsandconditionsappearingonanypurchaseorderorother
documentsubmittedbyYou.Affiliate”meansanyperson,partnership,corporation,limitedliabilitycompany,otherformof
enterprisethatdirectlyorindirectlythroughoneormoreintermediaries,controls,oriscontrolledby,or
isundercommon
controlwiththepartyspecified.ThisAgreementconstitutestheentireunderstandingbetweentheparties,withrespecttothe
subjectmatterofthisAgreement.TheProgrammaybecontainedinfirmware,chipsorothermedia.
BYINSTALLINGOROTHERWISEUSINGTHEPROGRAM,YOUREPRESENTTHATYOUAREAUTHORIZEDTO
ACCEPTTHESETERMSONBEHALFOFTHEENDUSER(IFTHEENDUSERISANENTITYONWHOSEBEHALFYOU
AREAUTHORIZEDTOACT,“YOU”AND“YOUR”SHALLBEDEEMEDTOREFERTOSUCHENTITY)ANDTHATYOU
AGREETHATYOUAREBOUNDBYTHETERMSOFTHISAGREEMENT,WHICHINCLUDES,
AMONGOTHER
PROVISIONS,THELICENSE,THEDISCLAIMEROFWARRANTYANDTHELIMITATIONOFLIABILITY.IFYOUDONOT
AGREETOTHETERMSOFTHISAGREEMENTORARENOTAUTHORIZEDTOENTERINTOTHISAGREEMENT,
ENTERASYSISUNWILLINGTOLICENSETHEPROGRAMTOYOUANDYOUAGREETORETURNTHEUNOPENED
PRODUCTTOENTERASYSORYOURDEALER,IFANY,WITHINTEN(10)DAYSFOLLOWINGTHEDATEOFRECEIPT
FORAFULLREFUND.
IFYOUHAVEANYQUESTIONSABOUTTHISAGREEMENT,CONTACTENTERASYSNETWORKS,LEGAL
DEPARTMENTAT(978)6841000.
YouandEnterasysagreeasfollows:
1. LICENSE. Youhavethenonexclusiveandnon
transferablerighttouseonlytheone(1)copyoftheProgramprovidedin
thispackagesubjecttothetermsandconditionsofthisAgreement.
vii
2. RESTRICTIONS. ExceptasotherwiseauthorizedinwritingbyEnterasys,Youmaynot,normayYoupermitanythird
partyto:
(a) Reverseengineer,decompile,disassembleormodifytheProgram,inwholeorinpart,includingforreasonsoferror
correctionorinteroperability,excepttotheextentexpresslypermittedbyapplicablelawand
totheextenttheparties
shallnotbepermittedbythatapplicablelaw,suchrightsareexpresslyexcluded.Informationnecessarytoachieve
interoperabilityorcorrecterrorsisavailablefromEnterasysuponrequestanduponpaymentofEnterasys’applicable
fee.
(b) IncorporatethePrograminwholeorinpart,inanyotherproduct
orcreatederivativeworksbasedontheProgram,in
wholeorinpart.
(c) Publish,disclose,copyreproduceortransmittheProgram,inwholeorinpart.
(d) Assign,sell,license,sublicense,rent,lease,encumberbywayofsecurityinterest,pledgeorotherwisetransferthe
Program,inwholeorinpart.
(e) Removeanycopyright,
trademark,proprietaryrights,disclaimerorwarningnoticeincludedonorembeddedinany
partoftheProgram.
3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourts
oftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youaccept
thepersonaljurisdiction
andvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNationsConventionontheLimitationPeriod
intheInternationalSaleofGoods,andtheUniformComputerInformationTransactionsActshallapplytothisAgreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubject
toregulationbyagenciesofthe
U.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertaintechnicalproducts
tocertaincountries,unlessalicensetoexporttheproductisobtainedfromtheU.S.Governmentoranexceptionfromobtaining
suchlicensemayberelieduponby
theexportingparty.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusetheProgramfor
civilendusesonlyandnot
formilitarypurposes.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSection1or2ofthisAgreement,Youagreenot
to(i)reexportorreleasetheProgram,
thesourcecodefortheProgramortechnologytoanationalofacountryinCountry
GroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Cambodia,Cuba,Georgia,Iraq,Kazakhstan,Laos,Libya,Macau,
Moldova,Mongolia,NorthKorea,thePeople’ sRepublicofChina,Russia,Tajikistan,Turkmenistan,Ukraine,Uzbekistan,
Vietnam,orsuchother
countriesasmaybedesignatedbytheUnitedStatesGovernment),(ii)exporttoCountryGroupsD:1or
E:2(asdefinedherein)thedirectproductoftheProgramorthetechnology,ifsuchforeignproduceddirectproductissubjectto
nationalsecuritycontrolsasidentifiedontheU.S.CommerceControlList,or
(iii)ifthedirectproductofthetechnologyisa
completeplantoranymajorcomponentofaplant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantora
majorcomponentthereof,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrolsas
identifiedonthe
U.S.CommerceControlListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyatprivate
expense;(ii)contains“restrictedcomputersoftware”submittedwithrestrictedrightsinaccordancewithsection52.22719(a)
through
(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)inallrespectsis
proprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,theProgramisconsidered
commercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,anduse,duplication,or
disclosurebytheU.S.Governmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUINWRITING
BYENTERASYS,ENTERASYSDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,INCLUDINGBUTNOT
LIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORYQUALITY,FITNESSFORAPARTICULAR
PURPOSE,TITLEANDNONINFRINGEMENTWITHRESPECTTOTHEPROGRAM.IFIMPLIEDWARRANTIESMAYNOT
BEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIEDWARRANTIESARELIMITEDINDURATIONTOTHIRTY
(30)DAYSAFTERDELIVERYOFTHEPROGRAMTOYOU.
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITSSUPPLIERSBE
LIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,PROFITS,
BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,CONSEQUENTIAL,OR
RELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTOUSETHEPROGRAM,EVENIF
ENTERASYSHASBEENADVISEDOFTHEPOSSIBILITYOF
SUCHDAMAGES.THISFOREGOINGLIMITATIONSHALL
APPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICHDAMAGESARESOUGHT.
THECUMULATIVELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,IN
CONTRACT,TORTOROTHERWISE,SHALLNOTEXCEEDTHETOTALAMOUNTOFFEESPAIDTOENTERASYSBY
YOUFOR
THERIGHTSGRANTEDHEREIN.
viii
8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcritical
valuetoEnterasys,and,accordingly,Youherebyagreetomaintaincompletebooks,recordsandaccountsshowing(i)license
feesdueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.Youalso
granttoEnterasysanditsauthorized
representatives,uponreasonablenotice,therighttoauditandexamineduringYournormalbusinesshours,Yourbooks,records,
accountsandhardwaredevicesuponwhichtheProgrammaybedeployedtoverifycompliancewiththisAgreement,including
theverificationofthelicensefeesdueand
paidEnterasysandtheuse,copyinganddeploymentoftheProgram.Enterasys’right
ofexaminationshallbeexercisedreasonably,ingoodfaithandinamannercalculatedtonotunreasonablyinterferewithYour
business.IntheeventsuchauditdiscoversnoncompliancewiththisAgreement,includingcopiesoftheProgrammade,
used
ordeployedinbreachofthisAgreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasysreserves
theright,tobeexercisedinitssolediscretionandwithoutpriornotice,toterminatethislicense,effectiveimmediately,forfailure
tocomplywiththisAgreement.Uponanysuchtermination,
YoushallimmediatelyceasealluseoftheProgramandshallreturn
toEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.YouacknowledgeandagreethattheProgram
constitutestradesecretsand/orcopyrightedmaterialofEnterasysand/orits
suppliers.Youagreetoimplementreasonable
securitymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleandinterestinandtotheProgramshall
remainwithEnterasysand/oritssuppliers.AllrightsnotspecificallygrantedtoYoushallbereservedtoEnterasys.
10. ENFORCEMENT. Youacknowledgeandagreethat
anybreachofSections2,4,or9ofthisAgreementbyYoumaycause
Enterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasysmaybeentitled
toseektimelyinjunctiverelieftoprotectEnterasys’rightsunderthisAgreementinadditiontoanyandall
remediesavailableat
law.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligationsunderthis
Agreement,exceptthatYoumayassignthisAgreementtoanypersonorentitywhichacquiressubstantiallyallofYourstock
assets.EnterasysmayassignthisAgreementinits
solediscretion.ThisAgreementshallbebindinguponandinuretothebenefit
oftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsaspermittedbythisAgreement.Any
attemptedassignment,transferorsublicenseinviolationofthetermsofthisAgreementshallbevoidandabreachof
this
Agreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbeinwritingand
willnotbeconstruedasawaiverofanysubsequentbreachofsuchtermorcondition.Enterasys’failuretoenforceatermupon
Yourbreachof
suchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcementonanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,thevalidity,
legalityandenforceabilityofanyoftheremainingprovisionsshallnotinany
waybeaffectedorimpairedthereby,andthat
provisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuchinvalidity,illegality,or
unenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalorunenforceablesuchprovisioninanyother
jurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyupon
Yourbreachofanyofthetermsand
conditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshallreturn
toEnterasystheProgramandallcopiesoftheProgram.
ix
Contents
About This Guide
Who Should Use This Guide ...........................................................................................................................xiii
How to Use This Guide ....................................................................................................................................xiii
Related Documents .........................................................................................................................................xiii
Document Conventions ...................................................................................................................................xiv
Commonly Used Acronyms .............................................................................................................................xiv
Getting Help ......................................................................................................................................................xv
Chapter 1: Introduction
Overview .........................................................................................................................................................1-1
Features .........................................................................................................................................................1-2
PoE (Power over Ethernet) Support .........................................................................................................1-3
Fan Management .....................................................................................................................................1-4
Chapter 2: Installation
Unpacking the G-Series Switch ......................................................................................................................2-2
Shipped With the Switch ..........................................................................................................................2-2
Required and Shipped Separately ...........................................................................................................2-2
Optional Enterasys Components .............................................................................................................2-2
Order of Installation Steps ..............................................................................................................................2-3
G3G124-24 Optional PoE Module Installation Considerations ................................................................2-3
Mounting the Switch .......................................................................................................................................2-3
Placing the Switch on a Flat Surface .......................................................................................................2-4
Installing the Switch into a Rack ..............................................................................................................2-4
Installing and Removing a Power Supply .......................................................................................................2-5
Power Supply Planning ............................................................................................................................2-6
Installing a Power Supply .........................................................................................................................2-7
Removing a Power Supply .......................................................................................................................2-8
Installing and Removing an IOM ....................................................................................................................2-9
Installing an Optional PoE Module on the G3G-24TX ..............................................................................2-9
Installing an IOM ....................................................................................................................................2-10
Removing an IOM ..................................................................................................................................2-11
Connecting Power to the Switch ...................................................................................................................2-12
Connecting to the Console Port ....................................................................................................................2-13
Connecting to the RJ45 Console Port ....................................................................................................2-13
Connecting to the USB Console Port .....................................................................................................2-14
Connecting to the Network ...........................................................................................................................2-14
Connecting UTP Cables to RJ45 Ports ..................................................................................................2-14
Installing Optional SFP/XFP ...................................................................................................................2-17
Removing an XFP/SFP ..........................................................................................................................2-19
Connecting Fiber-Optic Cables to SFP/XFP Ports .................................................................................2-19
Completing the Installation ...........................................................................................................................2-20
Installing an Optional PoE Module in the G3G124-24 Switch ......................................................................2-21
Removing the Switch Cover ...................................................................................................................2-21
Installing the PoE Module ......................................................................................................................2-22
Chapter 3: Troubleshooting
Checking the LEDs .........................................................................................................................................3-2
SYSTEM LED ..........................................................................................................................................3-2
Power LEDs .............................................................................................................................................3-3
x
IOM Status LEDs .....................................................................................................................................3-3
Fixed and IOM Port LEDs ........................................................................................................................3-3
Using the Reset Button ...................................................................................................................................3-4
Removing the Switch from a Rack .................................................................................................................3-4
Appendix A: Specifications
Switch Specifications ......................................................................................................................................A-1
IOM Module Specifications .............................................................................................................................A-3
Torque Values ................................................................................................................................................A-5
1-Gigabit Ethernet and 100Base-FX Transceiver (SFP) Specifications .........................................................A-5
MGBIC-LC01/MGBIC-MT01 Specifications (1000BASE-SX) ..................................................................A-6
MGBIC-02 Specifications (1000BASE-T) .................................................................................................A-6
MGBIC-LC03 Specifications (1000BASE-SX) .........................................................................................A-7
MGBIC-LC04 Specifications (100BASE-FX) ............................................................................................A-7
MGBIC-LC05 Specifications (100BASE-FX) ............................................................................................A-8
MGBIC-LC07 Specifications (1000BASE-ELX) .......................................................................................A-8
MGBIC-08 Specifications (1000BASE-ELX) ............................................................................................A-9
MGBIC-LC09 Specifications (1000BASE-LX) ..........................................................................................A-9
10-Gigabit Ethernet Transceiver (XFP) Specifications ...................................................................................A-9
Console Port Pinout Assignments ................................................................................................................A-10
Regulatory Compliance ................................................................................................................................A-10
Figures
1-1 G3G124-24 Switch (front view) with one G3G-24TX IOM installed in Slot 2. ....................................1-1
1-2 G3G124-24 Switch (rear view) with 1200 and 400-watt power supplies installed..............................1-2
2-1 Attaching the Brackets to the Switch (G3G124-24 with G3G-24TX IOM shown)...............................2-5
2-2 Installing a Power Supply Module (1200-watt module into PWR 2 slot shown) ................................2-8
2-3 Installing a PoE module in the G3G-24TX IOM................................................................................2-10
2-4 Installing an IOM (G3G-24TX with optional PoE shown)..................................................................2-11
2-5 Connecting a UTP Cable Segment to RJ45 Port .............................................................................2-15
2-6 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TX.......................................................2-16
2-7 Four-Wire Straight-Through Cable RJ45 Pinouts for 10/100BASE-TX ............................................2-16
2-8 Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TX.............................................2-16
2-9 Eight-Wire Straight-Through Cable RJ45 Pinouts for 10/100/1000BASE-TX ..................................2-17
2-10 Installing an SFP/XFP (shown with LC connector and without dust cover)......................................2-18
2-11 Cable Connection (LC shown) to Uplink Port with SFP/XFP Installed .............................................2-20
2-12 Screw and Coverplate Removal for Removing the G3G124-24 Cover ............................................2-22
3-1 G3 system LEDs (G3G124-24 shown)...............................................................................................3-2
3-2 Locating the Reset button...................................................................................................................3-4
Tables
2-1 Power Distribution According to Number of Installed Power Supplies ...............................................2-6
2-2 Console Port Pinout..........................................................................................................................2-13
2-3 RJ45 to DB9 Adapter Pinout ............................................................................................................2-14
3-1 SYSTEM LED Definitions...................................................................................................................3-2
3-2 Power LED Definitions........................................................................................................................3-3
3-3 IOM Status LED Definitions................................................................................................................3-3
3-4 Port LED Definitions ...........................................................................................................................3-3
A-1 G3 Switch Specifications....................................................................................................................A-1
A-2 G3G-24TX IOM Specifications ...........................................................................................................A-3
A-3 G3G-24SFP IOM Specifications.........................................................................................................A-3
A-4 G3K-2TX and G3K-4TX IOM Specifications.......................................................................................A-4
A-5 Recommended Torque Values by Screw Size...................................................................................A-5
A-6 Mini-GBIC Input/Output Port Specifications .......................................................................................A-5
A-7 MGBIC-LC01/MGBIC-MT01 Optical Specifications ...........................................................................A-6
xi
A-8 MGBIC-LC01/MGBIC-MT01 Operating Range ..................................................................................A-6
A-9 MGBIC-02 Specifications ...................................................................................................................A-6
A-10 MGBIC-LC03 Optical Specifications...................................................................................................A-7
A-11 MGBIC-LC03 Operating Range..........................................................................................................A-7
A-12 MGBIC-LC04 Optical Specifications...................................................................................................A-7
A-13 MGBIC LC04 Operating Range..........................................................................................................A-7
A-14 MGBIC-LC05 Optical Specifications...................................................................................................A-8
A-15 MGBIC LC05 Operating Range..........................................................................................................A-8
A-16 MGBIC-LC07 Optical Specifications...................................................................................................A-8
A-17 MGBIC-LC07 Operating Range..........................................................................................................A-8
A-18 MGBIC-08 Optical Specifications .......................................................................................................A-9
A-19 MGBIC-08 Operating Range ..............................................................................................................A-9
A-20 MGBIC-LC09 Optical Specifications...................................................................................................A-9
A-21 MGBIC-LC09 Operating Range..........................................................................................................A-9
A-22 XFP Fiber-Optic Specifications.........................................................................................................A-10
A-23 Recommended Cable Types and Specifications..............................................................................A-10
A-24 Compliance Standards.....................................................................................................................A-10
Index
xii
Enterasys G-Series Hardware Installation Guide xiii
About This Guide
Thisguideprovidesanoverview,specificationsandinstructionsforinstallingtheEnterasy
GSeriesEthernetSwitchinastandard19inchequipmentrack,oronasuitableflatsurface.This
guidealsoexplainshowtointerpretthesystemstatusLEDstofacilitatetroubleshootingwhen
necessary,andalsoprovidesinformationonhow
tocontactEnterasysNetworksforadditional
help.
Who Should Use This Guide
Thisguideisintendedforanetworkadministratorwhoisresponsibleforinstallingandsettingup
theGSeriesswitch.
How to Use This Guide
Readthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandtogainan
understandingofthefeaturesandcapabilitiesoftheGSeriesswitch.Ageneralworking
knowledgeofdatacommunicationsnetworksishelpful.
Related Documents
ToconfiguretheGSeriesswitch,refertotheEnterasysGSeriesConfigurationGuide.
ManualscanbeaccessedontheWorldWideWeb,usingthefollowingURL:
http://www.enterasys.com/support/manuals/
Electrical Hazard: Only qualified personnel should install or service this unit.
Riesgo Electrico: Nada mas personal capacitado debe de instalar o darle servicio a esta unida.
Elektrischer Gefahrenhinweis: Installationen oder Servicearbeiten sollten nur durch
ausgebildetes und qualifiziertes Personal vorgenommen werden.
For information about... Refer to...
An overview of the G-Series chassis Chapter 1, Introduction
Instructions to install the G-Series chassis hardware Chapter 2, Installation
Troubleshooting installation problems and diagnosing
network/operational problems
Chapter 3, Troubleshooting
Specifications, environmental requirements, and physical
properties of the G-Series.
Appendix A, Specifications
Document Conventions
xiv About This Guide
Document Conventions
Thefollowingtypographicalconventionsandiconsareusedinthi sguide.
Commonly Used Acronyms
Thefollowingacronymsareusedextensivelythroughoutthisguide:
•IOMInput/OutputModule
•LEDLightEmittingDiode
•SFP1GigabitSmallFormFactorPluggablefiberoptictransceiver
•XFP‐10GigabitSmallFormFactorPluggablefiberoptictransceiver
•USBUniversalSerialBus
•ESDElectrostaticDischarge
•PoEPoweroverEthernet
blue type Indicates a hypertext link. When reading this document online, click the text in blue to go to
the referenced figure, table, or section.
Lowercase x Indicates the general use of an alphanumeric character (for example, 6x1xx, the x’s
indicate a combination of numbers or letters).
Note: Calls the reader’s attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaución: Contiene información esencial para prevenir dañar el equipo.
Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfällen führen können!
Electrical Hazard: Warns against an action that could result in personal injury or death.
Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte debido a un riesgo eléctrico.
Elektrischer Gefahrenhinweis: Warnung vor sämtlichen Handlungen, die zu Verletzung
von Personen oder Todesfällen – hervorgerufen durch elektrische Spannung – führen
können!
Getting Help
Enterasys G-Series Hardware Installation Guide xv
Getting Help
ForadditionalsupportrelatedtotheGSeriesswitch,theIOMs,orthisdocument,contact
Enterasys Networksusingoneofthefollowingmethods:
BeforecontactingEnterasys Networksfortechnicalsupport,havethefollowingdataready:
•YourEnterasys Networksservicecontractnumber
•Adescriptionofthefailure
•Adescriptionofanyaction(s)alreadytakentoresolvethe
problem(forexample,rebooting
theunit)
•TheserialandrevisionnumbersofallinvolvedEnterasys Networksproductsinthenetwork
•Adescriptionofyournetworkenvironment(suchaslayout,cabletype,otherrelevant
environmentalinformation)
•Networkloadandframesizeatthetimeoftrouble(ifknown)
•Thedevicehistory(forexample,if
youhavereturnedthedevicebefore,orifthisisarecurring
problem)
•AnypreviousReturnMaterialAuthorization(RMA)numbers
World Wide Web www.enterasys.com/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
To find the Enterasys Networks Support toll-free number in your country:
www.enterasys.com/support
Internet mail sup[email protected]
To expedite your message, please type [Switching] in the subject line.
To send comments or suggestions concerning this document to the Technical Publications Department:
To expedite your message, include the document Part Number in the Email message.
Getting Help
xvi About This Guide
Enterasys G-Series Hardware Installation Guide 1-1
1
Introduction
TheGSeriesEthernetswitchisamodular,highdensityswitchdesignedtohandlenetworking
demandsincommercialandinstitutionalsettings,includingeducation,government,andfinancial
environments.
Overview
TheGSeriesproductfamilyincludestheG3G12424,G3G12424PandG3G17024basesystems.
Thesesystemsprovideeither24copperFastEthernetRJ45portsandtwo1GigabitSmallForm
FactorPluggablefiberoptictransceiver(SFP)comboports,or24SFPports,inthelowerleftfront
panel(fixed
Slot1).PoweroverEthernet(PoE)isfactoryinstalledontheG3G12424Pbasechassis.
ThebasesystemsalsofeaturethreefrontaccessI/OslotsforinstallingoptionaladditionalIOMs.
Currently,therearefourGSeriesproductfamilyIOMsavailablefortheswitch:a24port
1000BASETX(RJ45)and
2comboportSFPmodule(similartothebasesystemfrontpanel
interfaceconfiguration),a24portSFPmodule,a2port10GigabitXFPmoduleanda4port10
GigabitXFPmodule.
TheGSeriesswitchcanbeplacedasafreestandingunitorinstalledintoastandard48.26
centimeter(19inch)rack.
Figure 1-1 G3G124-24 Switch (front view) with one G3G-24TX IOM installed in Slot 2.
1 SYSTEM LED 8 SFP combo ports
2 Power Supply LEDs (PWR1 and PWR2) 9 IOM module handle (G3G-24TX in Slot 2)
3 IOM power off buttons (Slots 2, 3 and 4) 10 Captive screw
4 USB console port 11 Optional IOM Slot 4 (with coverplate)
5 RJ45 console port 12 Optional IOM Slot 3 (with coverplate)
6 Fixed slot 1 RJ45 ports 13 IOM power off status LEDs (Slots 2, 3 and 4)
7
Port LEDs
Features
1-2 Introduction
Figure 1-2 G3G124-24 Switch (rear view) with 1200 and 400-watt power supplies installed
Features
TheGSeriesswitchesincludethefollowingfeatures:
•Abasesystem(chassis)containingfixedinterfacesinthelowerleftfrontpanel
–24RJ45(10/100/1000Mbps,100 0BASETXcopper)portsplus2comboSFPports(G3G124
24andG3G12424P)
–24SFPports(G3G17024 )
•Input/OutputModules(IOMs)
TherearethreeI/Oslotsonthefront
oftheGSeriesswitch,eachofwhichcanbepopulated
withtheavailableIOMs.IOMscanbeinsertedwhenpowerissuppliedtothebasesystem
withoutimpactingothermodules.NewlyinstalledIOMswillnotberecognizedbythesystem,
however,untiltheswitchisrebooted.Formoreinformationonremoving
amodule,referto
RemovinganIOMonpage 211.TheIOMsavailablefortheG3basesystemsare:
–G3G24TX,a24port1000BASETX(RJ45)and2comboportSFPmodule
–G3G24SFP,a24portSFPmodule
–G3K2XFP,a2portXFPmodule
–G3K4XFP,a4
portXFPmodule
1 AC power inlet 5 Memory slot with coverplate (reserved for future use)
2 PWR Slot 2 with 1200-watt power supply 6 Password reset button
3 PWR Slot 1 with 400-watt power supply 7 Optional module slot (reserved for later use)
4
Captive screw
Notes: Each combo SFP port on the G3G124-24, G3G124-24P or G3G-24TX supports the
installation of Mini-GBICs for 1000Base-SX, 1000Base-LX, 100Base-FX or 1000Base-T copper
SFP transceivers.
Each combo SFP port in use on these 10/100/1000 base systems or the G3G-24TX module
eliminates the availability of one RJ45 port. In other words, only 24 ports can be active at any given
time on components equipped with a combination of RJ45 and SFP interfaces. When an SFP
transceiver (Mini-GBIC) SFP port 23 establishes a link, RJ45 port 23 is disabled. When an SFP
transceiver (Mini-GBIC) in SFP port 24 establishes a link, RJ45 port 24 is disabled.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59

Enterasys Networks G3G124-24 User manual

Category
Network switches
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI