9.2 Use Smart Meter Verification (SMV) .......................................................................................... 140
9.2.1 SMV requirements ...................................................................................................... 140
9.2.2 SMV test preparation .................................................................................................. 140
9.2.3 Run SMV ..................................................................................................................... 141
9.2.4 View test data .............................................................................................................145
9.2.5 Schedule automatic execution of the SMV test ........................................................... 149
9.3 Use PVR, TBR, and TMR ..............................................................................................................152
9.3.1 PVR, TBR, and TMR applications ..................................................................................153
9.4 Piecewise linearization (PWL) for calibrating gas meters ............................................................154
9.5 Use the fuel consumption application ....................................................................................... 154
9.5.1 Fuel consumption application architecture ................................................................. 154
9.6 Zero the meter .......................................................................................................................... 155
9.7 Validate the meter .....................................................................................................................156
9.7.1 Alternate method for calculating the meter factor for volume flow .............................158
9.8 Perform a (standard) D1 and D2 density calibration ...................................................................158
9.8.1 Perform a D1 and D2 density calibration using ProLink III ............................................ 159
9.8.2 Perform a D1 and D2 density calibration using the Field Communicator ..................... 160
9.9 Perform a D3 and D4 density calibration (T-Series sensors only) ................................................ 161
9.9.1 Perform a D3 or D3 and D4 density calibration using ProLink III .................................. 162
9.9.2 Perform a D3 or D3 and D4 density calibration using the Field Communicator ........... 163
9.10 Perform temperature calibration ...............................................................................................164
9.10.1 Perform temperature calibration using the display ..................................................... 165
9.10.2 Perform temperature calibration using ProLink III .......................................................165
9.10.3 Perform temperature calibration using the Field Communicator ................................167
Chapter 10 Troubleshooting ..........................................................................................................169
10.1 Status LED states ....................................................................................................................... 170
10.2 Status alerts, causes, and recommendations ............................................................................. 170
10.3 Locate a device using the HART 7 Squawk feature ..................................................................... 181
10.4 Flow measurement problems ................................................................................................... 181
10.5 Density measurement problems ............................................................................................... 183
10.6 Temperature measurement problems .......................................................................................184
10.7 Milliamp output problems ......................................................................................................... 185
10.8 Frequency Output problems ......................................................................................................187
10.9 Using sensor simulation for troubleshooting ............................................................................. 188
10.10 Check power supply wiring ........................................................................................................188
10.11 Check sensor-to-transmitter wiring ........................................................................................... 189
10.12 Check grounding .......................................................................................................................190
10.13 Perform loop tests .....................................................................................................................190
10.13.1 Perform loop tests using the display ...........................................................................190
10.13.2 Perform loop tests using ProLink III .............................................................................192
10.13.3 Perform loop tests using the Field Communicator ......................................................193
10.14 Trim mA output .........................................................................................................................195
10.14.1 Trim mA output using ProLink III ................................................................................ 195
10.14.2 Trim mA outputs using the Field Communicator .........................................................195
10.15 Check the HART communication loop ....................................................................................... 196
10.16 Check HART Address and mA Output Action ............................................................................. 196
10.17 Check HART burst mode ............................................................................................................197
10.18 Check Lower Range Value and Upper Range Value ....................................................................197
10.19 Check mA Output Fault Action ..................................................................................................197
10.20 Check for radio frequency interference (RFI) ..............................................................................198
10.21 Check Frequency Output Scaling Method ................................................................................. 198