Danfoss ECA 61 remote control offers precise climate control based on actual room temperature. Change modes, adjust desired temperature, and monitor the outdoor temperature. Use the timer function for temporary temperature changes, or set holiday and day-off schedules to maintain a comfortable indoor climate while you're away or on a break.

Danfoss ECA 61 remote control offers precise climate control based on actual room temperature. Change modes, adjust desired temperature, and monitor the outdoor temperature. Use the timer function for temporary temperature changes, or set holiday and day-off schedules to maintain a comfortable indoor climate while you're away or on a break.

ECA 61 Remote controller
VI.7F.A1.02 087R9524
How the buttons work
Shift button
Use to see highest and lowest outdoor temperature
and for week plan adjustments
Timer button
Use to change the room temperature temporarily
Mode selector
Use to change mode of operation
Arrow buttons
Use for Holiday and Day off functions
and to check the week plan
Plus/Minus buttons
Use to adjust desired temperature
and for week plan and other adjustments
+1
Getting the most out of your
Remote controller
1 The daily display
2 Selecting the controller mode
3 Monitoring the outdoor temperature
4 Using the timer
5 Holiday setting
6 Day off setting
7 Checking your week plan
8 Changing Comfort periods
9 Setting the clock
10 Checking service settings
Notes to the installer
Your ECL 61 Remote controller gives you precise climate
control based on actual room temperature. It allows you the
same adjustments to your week plan as the ECL Comfort
controller,
with additional holiday and timer functions.
The daily display
Adjusting your room temperature
Open the lid to find the buttons
Adjust for the desired temperature
Depending on the week plan, you will adjust either the Comfort
or Reduced temperature. Look at the white pointer.
1
Room
temperature
Today’s schedule
Desired
temperature
913-
20
0 3 6 9 12 15 18 21 24
A
Outdoor
temperature
Line
indicator
9 Maximum room temperature influence
0
...
+99 0
10
...
30
o
C 18
o
C
o
C
Setting range Factory Your setting
When installing the Remote controller, make sure you check
these settings, and alter if necessary:
The heating plant is stopped when the outdoor temperature reaches
the set limit. A lower value saves more energy.
-99
...
040
When the room temperature is above the desired level, this setting
decides how hard the controller tries to decrease the flow
temperature.
10 Minimum room temperature influence
A “0” means that the controller only limits the room temperature
when above the desired level. If reference room control is required,
increase this value to e.g. +4.
For details, please refer to the ECL Comfort controller manual,
sections 21 and 23.
8 Summer cutout
Selecting controller mode
Automatic operation
This is the normal mode. The temperature shifts
between comfort level and reduced level according
to the week plan in the ECL Comfort controller
Comfort temperature mode
Reduced temperature mode
The white pointer shows current temperature
(Comfort or Reduced) when in Automatic mode
2
Push to change the mode of the controller
Checking service settings
Open the lid and go to line 7
Hold button down for 2 seconds
Setting value
Setting
range indicator
Setting
number
8
18
Adjust if necessary
Move to next setting
When finished, return to line A
10
OL
4-
2300
IH
7
2105
8135
3-
Monitoring outdoor temperatures
Push 3 times to show highest and lowest
outdoor temperatures since midnight
Outdoor
temperature now
3
The daily display is restored after 3 seconds.
Time when
registered
Highest outdoor temperature
Clock
Lowest outdoor temperature
Setting the clock
9
Open the lid and press for three seconds:
The minute display flashes
Select next item and adjust
Return to the daily display when finished
Year
Hours, minutes
Month, day
Adjust minutes (if required)
061399
640
8
1
22h
935
1
1
Using the timer
Timer period
ends
Duration
of period
4
e.g. during a party, going out, or for increased comfort
Timer
temperature
Engage the timer and set the number of hours until the
controller resumes normal operation:
One push for each hour
+1
The controller will run at a special timer temperature for
the set duration.
Adjust the temperature if necessary:
Higher for increased comfort (e.g. 22
o
C) while you are
relaxing; lower for energy savings when going out
To cancel
Press the function selector
Holiday setting
Open the lid and go to line B
Duration
The controller will run at a constant reduced temperature
for the set duration.
5
Set the number of days until the controller reverts to
normal operation: One push for each day
To cancel
Press the function selector
61d
2
20
0 3 6 9 12 15 18 21 24
B
Restoring the factory set week plan
Push both together for 2 seconds
Push both together
Adjust first changeover time
200
0 3 6 9 12 15 18 21 24
1
Adding an extra period
New period
Select second changeover time and adjust
+1
Day off setting
Open the lid and go to line C
Duration
Set the controller to run a special Day off plan (Comfort
period: 6:00–23:00) for the next 24 hours from now.
Set additional days if required: One push for each day.
6
The Day off plan can be modified as shown in section 8.
Day off
plan
91d1
20
0 3 6 9 12 15 18 21 24
C
To cancel
Press the function selector
+1
600
0 3 6 9 12 15 18 21 24
Select changeover time
Changing Comfort periods
Adjust backward or forward
8
Changeover time
Removing a period
Push both together for 2 seconds
Move between single day plans
Checking your week plan
Open the lid and go to line 1
7
600
0 3 6 9 12 15 18 21 24
How to make changes
First
changeover
time
When finished, return to line A
Mondays
Wednesdays
Your personal week plan
Factory set week plan is shown in grey.
-3
-2
-1
Tuesdays
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Danfoss ECA 61 remote control User guide

Category
Electrical timers
Type
User guide

Danfoss ECA 61 remote control offers precise climate control based on actual room temperature. Change modes, adjust desired temperature, and monitor the outdoor temperature. Use the timer function for temporary temperature changes, or set holiday and day-off schedules to maintain a comfortable indoor climate while you're away or on a break.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI