CR22PRF / CR28PRF
Y Plan Wireless Pack Wiring Diagram
Page 1 of 1
Components:
1 x 2 Channel Wireless Programmer
1 x 3 Port Motorised Valve
1 x Wireless Room Thermostat
1 x Wireless Cylinder Thermostat
1 x Wiring Centre
EPH Controls Ireland
EPH Controls UK
2023-05-05_CR2_PRF_WD_PK
SPUR FUSED @ 3A R27-RF
Wireless Programmer
WIRING CENTRE
PUMP
BOILER
N L
12 4
MOTORISED VALVE
6
3
8
5
1
ORANGE
BLUE
GREY
WHITE
EARTH
N
L
1
3
7
N
L
1
3
7
123456789101112
CH
ON
N N L
LIVE TO
BOILER
& PUMP
HW
ON
HW
OFF
BLUE
CORE
WHITE
CORE
ORANGE
CORE
GREY
CORE
CAUTION!
Consult the boiler installation
instructions before wiring!
Boiler manufacturers wiring schematics may vary:
A permanent power supply may be required
An overrun function may be required
A volt-free signal from the motorised valves
limit switches may be required
RFC
Cylinder Thermostat
RFR
Room Thermostat
N L 1 2
1 2 4 8 6 5
3 4
HW
ON
HW
OFF
HTG
ON