Klimaire KWIM12-H2 User manual

Category
Split-system air conditioners
Type
User manual

This manual is also suitable for

P
Multi zone Indoor
I N D O O
Model Numbers:
KWIM09-H2
KWIM12-H2
KWIM18-H2
WARNING
Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code
NFPA70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1 .
The information contained in the manual is intended for use by a qualified service technician familiar with safety
procedures and equipped with the proper tools and test instruments
Installation or repairs made by unqualified persons can result in hazards to you and others.
Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage,
personal injury and/or death.
Table of Contents
1. Precaution
2. Product Description And Label
3. Dimension of indoor unit
4. Operation Characteristics
5. Electronic function
6. Wiring Diagrams
7. Trouble Shooting
8. Disassembly instructions
9. Exploded view
KWIM Series
Service Manual
CONTENTS
1. Precaution ........................................................................................................................................... 2
1.1 Safety Precaution ........................................................................................................................ 2
1.2 Warning ...................................................................................................................................... 2
2. Product Description And Label ............................................................................................................. 6
3. Dimension of indoor unit ..................................................................................................................... 7
4. Operation Characteristics ..................................................................................................................... 8
5. Electronic Function .............................................................................................................................. 8
5.1 Abbreviation ...................................................................................................................................... 8
5.2Main Protection .................................................................................................................................. 8
5.3 Operation Modes and Functions ........................................................................................................ 8
6. Wiring Diagrams..................................................................................................................................13
7. Troubleshooting ..................................................................................................................................14
7.1 Display Function ................................................................................................................................14
7.2Indoor Unit Error Display ....................................................................................................................15
7.3 Outdoor Unit Error Display ................................................................................................................16
7.4 Diagnosis and Solution ......................................................................................................................18
7.5 Trouble Criterion Of Main Parts. ........................................................................................................89
8. Disassembly Instructions ...................................................................................................................100
9. Exploded View ..................................................................................................................................105
2
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or
other people and property damage,
the following instructions must be
followed.
Incorrect operation due to ignoring
instruction will cause harm or
damage.
Before service unit, be sure to read
this service manual at first.
1.2 Warning
Installation
Do not use a defective or
underrated circuit breaker. Use this
appliance on a dedicated circuit.
There is risk of fire or electric
shock.
For electrical work, contact the
dealer, seller, a qualified electrician,
or an Authorized service center.
Do not disassemble or repair the
product, there is risk of fire or
electric shock.
Always ground the product.
Install the panel and the cover of
control box securely.
Always install a dedicated circuit
and breaker.
Improper wiring or installation may
cause fore or electric shock.
Use the correctly rated breaker of
fuse.
Do not modify or extend the power
cable.
The unit should be installed,
removed, or reinstalled by a
certified HVAC professional who is
locally licensed to handle this
product.
Be cautious when unpacking and
installing the product, sharp edges
could cause injury, be especially
careful of the edges of the
cabinet and the fins on the
condenser and evaporator.
For installation, always contact the
dealer or an authorized service
center.
Do not install the product on a
defective installation stand as this
may cause and accident, injury, or
damage to the product.
Be sure the installation area does
not deteriorate with age. If the
base collapses, the air conditioner
could fall with it, causing property
damage, product failure and
personal injury.
3
Take care to ensure that the power
cable could not be disconnected or
damaged during operation.
Do not place anything on the
power cable.
Do not unplug the power supply
plug during operation.
Do not touch (operation) the
product with wet hands.
Do not place a heater or other
appliance near the power cable.
Do not allow water to run into
electric parts. It may cause fire,
failure of the product, or electric
shock.
Do not store or use flammable gas
or combustible near the product.
Ensure that the condensing unit
has proper ventilation. Do not use
the product in a tightly closed
space for a long time.
If smoke is detected during the
operation of the unit, discontinue
use immediately. Turn the breaker
off or disconnect the power supply
cable.
Do not open the inlet grill of the
product during operation. (Do not
touch the electrostatic filter, if the
unit is so equipped.)
When the product is soaked
(flooded or submerged),
discontinue use immediately,
disconnect the power supply and
contact an authorized repair
technician or installer.
Turn the main power off when
cleaning or maintaining the product.
When the product is not be used
for a long time, disconnect the
power supply or turn off the
breaker.
CAUTION
Always check for gas (refrigerant)
leakage after installation or repair
of product.
Low refrigerant levels may cause
failure of product.
Install the drain hose to ensure
that water is drained away properly.
A bad connection may cause water
leakage.
Keep the product level during
installation
Use two or more people to lift and
transport the product.
Do not install the product where it
will be exposed to sea wind (salt
spray) directly as this may cause
corrosion on the condenser and
evaporator fins. Corrosion could
4
cause product malfunction or
inefficient operation.
Operational
Do not expose the skin directly to
cool air for long periods of time.
(Do not sit in the draft).
This could harm to your health.
Do not use the product for special
purposes, such as preserving
foods, works of art, etc. It is a
consumer air conditioner, not a
precision refrigerant system.
There is risk of damage or loss of
property.
Do not block the inlet or outlet of
air flow.
It may cause product failure.
Use a soft cloth to clean. Do not
use harsh detergents, solvents, etc.
There is risk of fire, electric shock,
or damage to the plastic parts of
the product.
Do not touch the metal parts of the
product when removing the air filter.
They are very sharp.
There is risk of personal injury.
Do not step on or put anything on
the product. (outdoor units)
There is risk of personal injury and
failure of product.
Always insert the filter securely.
Clean the filter every two weeks or
more often if necessary.
A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
Do not insert hands or other object
through air inlet or outlet while the
product is operated.
There are sharp and moving parts
that could cause personal injury.
Do not drink the water drained
from the product.
It is not sanitary could cause
serious health issues.
Use a firm stool or ladder when
cleaning or maintaining the product.
Be careful and avoid personal
injury.
Replace the all batteries in the
remote control with new ones of
the same type. Do not mix old and
mew batteries or different types of
batteries.
There is risk of fire or explosion.
Do not recharge or disassemble
the batteries. Do not dispose of
batteries in a fire.
They may burn of explode.
5
If the liquid from the batteries gets
onto your skin or clothes, wash it
well with clean water. Do not use
the remote of the batteries have
leaked.
The chemical in batteries could
cause burns or other health
hazards
6
2. Product Description And Label
7
3. Dimension of indoor unit
W(mm(in)) D(mm(in)) H(mm(in))
9K
795(31.3) 165(6.5) 270(10.63)
12K
845(33.27) 165(6.5) 286(11.26)
18K
995(39.17) 194(7.64) 295(11.61)
Dimension
W D
H
L
R
H
Model
L
H
Dimension of installation hole
KWIM09-H2
150mm
(5.91in)
45mm
(1.77in)
Φ65mm(2.56in)
KWIM12-H2
KWIM18-H2
150mm
(5.91in)
45mm
(1.77in)
8
4. Operation Characteristics
Temperature
Mode
Cooling
operation
Heating
operation
Drying
operation
Room temperature
62℉~90
32℉~86
62℉~90
Outdoor temperature
32℉~122
5℉~122
For the
models with low
temperature
cooling
system
5℉~76
32℉~122
CAUTION:
1. If air conditioner is used beyond the above
conditions, the certain protections may action.
2. Room relative humidity should be less than
80%. If the air conditioner operates in excess of
this value, the surface of the air conditioner may
attract condensation. In this case, please set the
vertical air louver to its maximum angle (vertically
to the floor), and set the fan to high speed.
5. Electronic Function
5.1 Abbreviation
T1: Indoor ambient temperature
T2: Pipe temperature of indoor heat exchanger
T3: Pipe temperature of outdoor heat exchanger
T4: Outdoor ambient temperature
T5 Discharge temperature
TsSetting temp.
5.2Main Protection
5.2.1 Three Minutes Delay at restart for
compressor.
5.2.2 Fan Speed is out of control.
----When Indoor Fan Speed keeps too low or too
high for certain time, the unit will stop and the
LED will display the failure
5.2.3 Indoor fan delayed open function
----When the system starts up, the louver will be
active immediately and the indoor fan will open
10s later.
----If the system runs in heating mode, the indoor
fan will be also controlled by anti-cold wind
function.
5.2.4 Zero crossing detection error protection
5.3 Operation Modes and Functions
5.3.1 Fan mode.
(1) The outdoor fan and compressor stop.
(2)Temperature setting function is disabled, and
no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates the same as in cooling
mode.
(5) Auto fan:
The action of auto fan in fan-only mode is the
same as auto fan in cooling mode with 24
setting temperature.
3.5
3.0
High
Low
1.0
Medium
1.5
Ts=24
9
5.3.2 Cooling Mode
5.3.2.1 Indoor fan running rules
In cooling mode, indoor fan runs all the time and
the speed can be selected as high, medium, low
and auto.
Auto fan in cooling mode acts as follow:
3.5
3.0
High
Low
1.0
Medium
1.5
5.3.2.4 Evaporator low temperature T2
protection.
When T2<4, the indoor has no capacity
demand and resume till T2>8.
5.3.3 Heating Mode
5.3.3.1 Indoor fan running rules:
Indoor fan speed can be set as high, medium, low
and auto fan and the anti-cold-wind function is
preferential.
For 9K/12K
44
38
37
34
T2
33
Setting
Low
Breeze
Off
TEL0
Super
Breeze
TEL1
For 18K
39
36
35
T2
32
Setting
Low
Breeze
Off
TEL0
Super
Breeze
TEL1
44
Medium
Auto fan action in heating mode.
2.5
2
High
Low
1
Medium
1.5
5.3.3.2 High evaporator coil temp.T2
protection:
10
If T2>63, the indoor unit has no capacity
demand and resume till 48.
5.3.4 Auto-mode
This mode can be chosen by remote controller
and the setting temperature can be changed
between 17~30.
In auto mode, the machine will choose cooling,
heating or fan-only mode according to ΔT (ΔT
=T1-Ts).
For 9K/12K
ΔT=T1-Ts
Running mode
ΔT1
Cooling
-1≤ΔT≤1
Fan-only
ΔT<-1
Heating
For 18K
ΔT=T1-Ts
Running mode
ΔT1
Cooling
-1<ΔT≤1
Fan-only
ΔT≤-1
Heating
Indoor fan will run at auto fan of the relevant
mode.
The louver operate same as in relevant mode.
If the machine switches mode between heating
and cooling, the compressor will keep stopping
for 15 minutes and then rechoose mode
according to T1-Ts.
If the setting temperature is modified, the
machine will rechoose running function.
5.3.5 Dehumidifier mode
5.3.5.1 Indoor fan speed is fixed at breeze and
can’t be changed. The louver angle is the same
as in cooling mode.
5.3.5.2 Overlow room temperature protection
In dehumidifier mode, if room temperature is
lower than 10, the indoor fan will stop and not
resume until room temperature exceeds 12.
5.3.5.3 Evaporator anti-freezing protection is
active
5.3.6 Forced operation function
5.3.6.1 Enter forced operation function:
Press the touch button continually, the AC will run
as below sequence:
When the machine is off, pressing the touch
button will carry the machine to forced auto
mode, after this, if pressing the button once
again, the machine will turn into forced cooling
mode.
In forced cooling mode, pressing touch button will
turn off the machine.
5.3.6.2 In forced operation mode, all general
protections and remote control are available.
5.3.6.3 Operation rules:
Forced cooling mode:
11
The indoor fan runs as breeze. After running for
30 minutes, AC will turn to auto mode with 24
setting temperature.
Forced auto mode:
The action of forced auto mode is the same as
normal auto mode with 24 setting temperature.
5.3.6.4 When there’s indoor unit running in forced
cooling, it is the master forced cooling unit. Other
indoor units will run at forced cooling mode too
and they will be the slave forced cooling unit. The
slave forced cooling units cannot quit forced
cooling mode until the master forced cooling unit
quit.
5.3.6.5 The slave forced cooling units will not be
controlled by other signals except timer off signal.
5.3.6.6 If AC is running in sleep mode and
receives forced operation signal, it will quit the
sleep mode.
5.3.7 Timer function
5.3.7.1 Timing range is 24 hours.
5.3.7.2 Timer on. The machine will turn on
automatically when reaching the setting time.
5.3.7.3 Timer off. The machine will turn off
automatically when reaching the setting time.
5.3.7.4 Timer on/off. The machine will turn on
automatically when reaching the setting “on” time,
and then turn off automatically when reaching the
setting “off” time.
5.3.7.5 Timer off/on. The machine will turn off
automatically when reaching the setting “off” time,
and then turn on automatically when reaching the
setting “on” time.
5.3.7.6 The timer function will not change the AC
current operation mode. Suppose AC is off now, it
will not start up firstly after setting the “timer off”
function. And when reaching the setting time, the
timer LED will be off and the AC running mode
has not been changed.
5.3.7.7 The setting time is relative time.
5.3.8 Sleep function mode
5.3.8.1 Operation time in sleep mode is 7 hours.
After 7 hours the AC quits this mode and turns
off.
5.3.8.2. Operation process in sleep mode is as
follow:
When cooling, the setting temperature rises 1
(be lower than 30) every one hour, 2 hours
later the setting temperature stops rising and
indoor fan is fixed as low speed.
When heating, the setting temperature decreases
1(be higher than 17) every one hour, 2 hours
later the setting temperature stops rising and
indoor fan is fixed as low speed.(Anti-cold wind
function has the priority)
5.3.8.3 Timer off and remote controller off signals
have the priority compared with sleep function.
5.3.8.4 When user uses timer off function in sleep
mode(or sleep function in timer off mode), if the
12
timing is less than 7 hours, sleep function will be
cancelled when reaching the setting time. If the
timing is more than 7 hours, the machine will not
stop until reaches the setting time in sleep mode.
5.3.9 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an auto-
restart module. In case of a sudden power failure,
the module memorizes the setting conditions
before the power failure. The unit will resume the
previous operation setting (not including Swing
function) automatically after 3 minutes when
power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24 setting
temp.
5.3.10 Ionizer
The indoor unit is equipped with Ionizer, which is
controlled by the CLEAN AIR button on the
remote controller. When the unit is turned on,
press the CLEAN AIR button to activate the
function. Press it again to stop the function.
During the time when Ionizer is controlled by
remote controller, Ionizer will be turned off
automatically if indoor fan stops running due to
malfunctions or anti-cold-wind. When indoor fan
restarts after malfunctions being eliminated and
anti-cold-wind being released, Ionizer will be
available again.
13
6. Wiring Diagrams
KWIM09-H2, KWIM12-H2, KWIM18-H2
14
7. Troubleshooting
7.1 Display Function
TIMER display
Illuminated during Timer operation.
CLEAN AIR display(optional)
Illuminated when Ionizer is activated.
TURBO operation display
Illuminated when select TURBO function in cooling operation or in
heating operation.
DIGITAL DISPLAY
Displayed the current setting temperature or malfunction code when
the air conditioner is in operation. When SELF CLEAN feature is
activated, it displays . “SC”
FAN SPEED display
Displayed the selected fan speed: LOW( ), MED( ) and
HIGH( ).
Operation Frequency display
This display is separated into five zones. The zones illuminate based on
the compressor current frequency. For example, higher frequency will
Illuminate more zones.
15
7.2Indoor Unit Error Display
Display
Failure
E0
Indoor EEPROM malfunction
E1
Indoor/ outdoor units communication error
E2
Zero-crossing signal error
E3
Indoor fan speed has been out of control
E5
Open circuit or short circuit of outdoor temperature sensor or outdoor EEPROM
malfunction
E6
Open circuit or short circuit of T1 or T2 temperature sensor
P0
IPM module protection or IGBT over-strong current protection
P1
Voltage protection
P2
Temperature protection of compressor top
P3
Outdoor temperature is lower than -15°C optional function
P4
Inverter compressor drive protection
P5
Mode conflict
Note
P3: If the outdoor temperature <= -15 °C for 1 hour, then the machine stops running, the indoor display
shows the error code "P3“. The unit can still receive remote control signals.
If the outdoor >= -12 °C for 10 minutes, the compressor stops running more than one hour,
Or the outdoor temperature>= 5 for 10 minutes, then AC will recover to the last mode and fan
speed.
E4 : Reserved function.
16
7.3 Outdoor Unit Error Display
For KSIM20912-H216 - 2G, KSIM30912-H216 - 1G, KSIM330-H219, KSIM40912-H216 - 2G
Display
LED STATUS
IDU
Error
(KWIL / KWIM)
IDU
Error
(KDIM
E0
Outdoor EEPROM malfunction
E5
E6
E2
Indoor / outdoor units communication error
E1
E2
E3
Communication malfunction between IPM board and outdoor main board
——
——
E4
Open or short circuit of outdoor temperature sensor(T3T4T5T2B)
E5
E6
E5
Voltage protection
P1
P0
E6
PFC module protection(Only for KSIM40912-H216 - 2G)
——
——
E8
Outdoor fan speed has been out of control(Only for DC fan motor models)
——
——
F1
No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
F2
No B Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
F3
No C Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
F4
No D Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
P0
Temperature protection of compressor top (Only for KSIM30912-H216 - 1G)
P2
P3
P1
High pressure protection (Only for KSIM40912-H216 - 2G)
——
——
P2
Low pressure protection(Only for KSIM40912-H216 - 2G)
——
——
P3
Current protection of compressor
——
——
P4
Temperature protection of compressor discharge
——
——
P5
High temperature protection of condenser
——
——
P6
IPM module protection
P0
E5
17
For M2OC-18HRDN1-M, M3OC-27HRDN1-M, KSIM40912-H216 - 1G
Display
digital tube
LED STATUS
IDU
Error
(KWIL / KWIM)
IDU
Error
KDIM
E0
Outdoor EEPROM malfunction
E5
E6
E1
No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
E2
No B Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
E3
No C Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
E6
No D Indoor unit coil outlet temp. sensor or connector of sensor is defective
——
——
E4
Open or short circuit of outdoor temperature sensor(T4)
E5
E6
E5
Voltage protection
P1
P0
E7
Communication malfunction between IPM board and outdoor main board
——
——
P0
Temperature protection of compressor discharge (Temperature protection of
compressor top(only for KSIM20912-H216 - 1G & KSIM30912-H216 - 2G) )
P2
P3
P1
High pressure protection (Only for KSIM40912-H216 - 1G)
——
——
P2
Low pressure protection(Only for KSIM40912-H216 - 1G)
——
——
P3
Current protection of compressor
——
——
P4
IPM module protection
P0
E5
P6
High temperature protection of condenser
——
——
P7
Inverter compressor drive protection
P4
P4
PF
PFC module protection(Only for KSIM40912-H216 - 1G)
——
——
18
7.4 Diagnosis and Solution
7.4.1 Indoor unit trouble shooting
7.4.1.1 E0(Indoor EEPROM malfunction) error diagnosis and solution
Error Code
E0
Malfunction decision
conditions
PCB main chip does not receive feedback from EEPROM chip
Supposed causes
Installation mistake
PCB faulty
Trouble shooting:
EEPROM: a read-only memory whose contents can be erased and reprogrammed using a pulsed voltage.
For the location of EEPROM chip, please refer to the below photos.
19
7.4.1.2 E1(Communication malfunction between indoor and outdoor units) error diagnosis
and solution.
Error Code
E1
Malfunction decision
conditions
Indoor unit does not receive the feedback from outdoor unit
during 120 seconds.
Supposed causes
Wiring mistake
Indoor or outdoor PCB faulty
Trouble shooting:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Klimaire KWIM12-H2 User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI