  • Hello! I am an AI chatbot trained to assist you with the Klimaire KSIL048-H216-OC User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DC INVERTER SERIES
Service Manual
WARNING
Installation MUST conform with local building codes or, in the absence of local codes, with the
National Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments
Installation or repairs made by unqualified persons can result in hazards to you and others.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
This service is only for service engineer to use.
Contents
Contents i
Part 1 General Information .................................................................................................... 1
Part 2 Indoor Units ................................................................................................................. 6
Part 3 Outdoor Units ............................................................................................................. 60
Part 4 Installation .................................................................................................................. 75
Part 5 Electrical Control System ....................................................................................... 106
The specifications, designs, and information in this book are subject to change without notice for
product improvement.
General Information
General Information 1
Part 1
General Information
1. Model Lists ................................................................................................. 2
2. External Appearance ................................................................................. 3
2.1 Indoor Units ............................................................................................................ 3
2.2 Outdoor Units ......................................................................................................... 3
3. Nomenclature ............................................................................................. 4
4. Features ...................................................................................................... 5
Model Lists
2 General Information
1. Model Lists
1.1 Indoor Units
R410A (capacity multiplied by 1000Btu/h)
Type Function 12 18 24 36 48
4-way cassette Cooling and heating
Duct Cooling and heating
Ceiling-floor Cooling and heating
Console Cooling and heating
1.2 Outdoor Units
Universal Outdoor unit Model Compressor type Compressor Brand Matched indoor units
KSIL012-H219-OC
Rotary GMCC
KUIM012-H2
KTIM012-H2
KDIM012-H2
KSIO012-H223-OC
Rotary GMCC
KSIL018-H220-OC
Rotary GMCC
KUIM018-H2
KTIM018-H2
KDIM018-H2
KSIO018-H221-OC
Rotary GMCC
KSIL024-H220-OC
Rotary GMCC
KUIM024-H2
KTIM024-H2
KDIM024-H2
KSIL036-H215-OC
Rotary MITSUBISHI
KUIM036-H2
KTIM036-H2
KDIM036-H2
KSIL048-H216-OC
Rotary MITSUBISHI
KUIM048-H2
KDIM048-H2
KTIM048-H2
External Appearance
General Information 3
2. External Appearance
2.1 Indoor Units
4-way cassette (12K, 18K) 4-way cassette (24K~48K)
Duct
Console
Ceiling-Floor (12K, 18K)
Ceiling-Floor (24K~48K)
2.2 Outdoor Units
Single fan outdoor unit
Double fan outdoor unit
Nomenclature
4 General Information
3. Nomenclature
3.1 Indoor Unit
3.2 Outdoor Unit
K U I
M
036 H 2
Power Supply
2 : 208-230 / 1 / 60
Operational Function
H: Heat Pump
Nominal Capacity
012: 12,000 Btu/h
018: 18,000 Btu/h
024: 18,000 Btu/h
030: 30,000 Btu/h
036: 36,000 Btu/h
Product Series
R: Series
Unit Type
I: Inverter
Product Type
S: System
Brand
K: Klimaire
O: Outdoor Dedicated
I : Indoor Unit
Nominal Efficiency
SEER
Power Supply
2 : 208-230 / 1 / 60
Operational Function
H: Heat Pump
Nominal Capacity
012: 12,000 Btu/h
018: 18,000 Btu/h
024: 18,000 Btu/h
030: 30,000 Btu/h
036: 36,000 Btu/h
Product Series
R: Series
Unit Type
I: Inverter
Product Type
S: System
Brand
K: Klimaire
K S I
L
036 H 2 19 O
Features
General Information 5
4. Features
4.1. Low ambient kit is standard for outdoor units
4.2. Network control function is standard for the indoor units.
4.3. Standard auto restart function and follow me function.
4.4. Slim cassette with standard remote controller, wire controller and CCM for optional. Med Duct and
HESP duct with standard wired controller, remote controller and CCM for optional.
4.5. Standard anti-cold air function.
4.6. Standard auto defrosting function.
4.7. Standard self-diagnose function.
4.8. Standard timer function and sleep mode function controlled by controller.
Indoor Units
6 Indoor Units
Part 2
Indoor Units
4-way Cassette Type ......................................................... 7
Duct Type ......................................................................... 22
Ceiling & Floor Type ....................................................... 38
Console Type ................................................................... 50
4-way Cassette Type
Indoor Units 7
4-way Cassette Type
1. Features (12K, 18K) .......................................................... 8
2. Features (24K,36K) ........................................................... 9
3. Dimensions ...................................................................... 13
4. Service Space .................................................................. 15
5. Wiring Diagrams ............................................................. 16
6. Electric Characteristics .................................................. 18
7. Sound Levels ................................................................... 18
8. Accessories ..................................................................... 19
9. The Specification of Power ............................................ 20
10. Field Wiring ................................................................... 21
Features (12K, 18K)
8 Indoor Units
1. Features (12K, 18K)
1.1 New panel
360°surrounding air outlet design, affords comfortable feeling
1.2 Compact design
The body size is 570×260×570mm, it’s just smaller than the ceiling board, so it’s very easy for
installation and will not damage the decoration. The panel size is 647×50×647mm.
The hooks are designed in the four corners of the body, which can save installation space.
1.3 Electric control box built-in design
The E-box is simply and safely built inside the indoor unit. It’s convenient for installation and
maintenance. Can check the control part easily, you only need to open the air return grille.
1.4 Air passage function
Reserves the space for air outlet from the side of indoor unit; It’s availed to connect air duct
from the two sides to the nearby small rooms.
Features (24K,36K)
Indoor Units 9
2. Features (24K,36K)
2.1 Overview
Compact design, super slim body size, less space requiring in installation
Each louver can be separately controlled, more comfort air blowing is possible.
Auto-lifting panel design, more convenient to clean and maintain the filter.(optional)
Old Cassette New slim cassette Volume change
Dimension
18K-24K 840*230*840 18K-24K 840*205*840
11%
30K 840*300*840 30K 840*205*840
32%
36K-48K 840*300*840 36K-48K 840*245*840
18%
2.2 Fresh air intake function
Fresh air fulfills air quality more healthy and comfortable.
Ventilation motor is optional to increase the effect of fresh air.
Features (24K,36K)
10 Indoor Units
2.3 Optional ionizer generator
Ionizer generator is optional to get refreshing air to your room.
Ionizer can be switched on or off by remote controller.
When pressing the Clean Air button on the remote controller, Ionizer will work and the indicator light on
display board will shine.
New air-intake
I
I
o
o
n
n
i
i
z
z
e
e
r
r
g
g
e
e
n
n
e
e
r
r
a
a
t
t
o
o
r
r
c
c
o
o
n
n
n
n
e
e
c
c
t
t
o
o
r
r
V
V
e
e
n
n
t
t
i
i
l
l
a
a
t
t
i
i
o
o
n
n
m
m
o
o
t
t
o
o
r
r
c
c
o
o
n
n
n
n
e
e
c
c
t
t
o
o
r
r
Features (24K,36K)
Indoor Units 11
2.4 External air duct design
Reserve external air duct, more flexible for the air supply.
2.5 Built-in draining pump
Due to the improvement of structure, more convenient to repair or replace the draining pump.
Built-in draining pump to make sure condensed water drain out reliably.
Draining Pump
Features (24K,36K)
12 Indoor Units
2.6 Terminals for alarm lamp and long-distance on-off controller connection are standard
Reserve terminals for the connection of alarm lamp and long-distance on-off controller, more human
control.
2.7 Optional touch screen wired controller
Touch screen wired controller is optional, with error code indication function. Better
man-machine conversation interface.
Undated structure design, 4-way wire layout design, no raised part at backside, more convenient to
place the wires and install the device.
Alarm lamp
Long-distance on-off controller
Dimensions
Indoor Units 13
3. Dimensions
12K, 18K
Panel
E-parts box
Gas side
Liquid side
4-install hanger
Body
Wiring connection port
Drain pipe
32
Fresh air intake
65
570
545
570
523
260
647
647
50
150
Distribution duct
170
2-
2-
4-Screw hole
(for install panel)
Drain hole
( for Service )
75
156
125
68
40
44
Dimensions
14 Indoor Units
24K,36K,48K
840
840
950
950
C
Test mouth &
Test cover
Drain hole
32
Wiring connection port
680
780
780
680
136
126
91
196
132
A
A
B
A
A
B
A
A
B
A
B
Service hole for
draining pump
Fresh air intake
75
55
80
80
4-install hanger
Gas side
Liquid side
E-parts box
135
90
Panel
Body
92929292
D
D
92 92
D
D
D
D
92
9292
92
92 92
92
92
D
D
Unit: mm
Capacity(KBtu/h)
A B C D
24 160 75 205 50
36 160 95 245 60
48 160 95 287 60
Service Space
Indoor Units 15
4. Service Space
Wiring Diagrams
16 Indoor Units
5. Wiring Diagrams
KTIM012-H2 KTIM018-H2
KTIM012-H2(B)
Wiring Diagrams
Indoor Units 17
KTIM024-H2 KTIM036-H2 KTIM048-H2
Electric Characteristics
18 Indoor Units
6. Electric Characteristics
Model
Indoor Unit
Hz Voltage Min Max
KTIM012-H2
60 208-230V 187V 253V
KTIM012-H2(B)
60 208-230V 187V 253V
KTIM018-H2
60 208-230V 187V 253V
KTIM024-H2
60 208-230V 187V 253V
KTIM036-H2
60 208-230V 187V 253V
KTIM048-H2
60 208-230V 187V 253V
7. Sound Levels
1.4m
Microphone
Model
Noise level dB(A)
H M L
KTIM012-H2
51 46 40.5
KTIM012-H2(B)
51 46 40.5
KTIM018-H2
51 46 40.5
KTIM024-H2
51 47 43
KTIM036-H2
52 47 44
KTIM048-H2
52 48 44
/