Contec DI-16(FIT)GY Owner's manual

Category
Digital & analog I/O modules
Type
Owner's manual

This manual is also suitable for

F&eIT Series
Isolated Digital Input/Output Module
DIO-8/8x(FIT)GY
Isolated Digital Input Module
DI-16x(FIT)GY
Isolated Digital Output Module
DO-16(FIT)GY
User’s Manual
CONTEC CO.,LTD.
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
i
Check Your Package
Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing
items, contact your retailer.
Product Configuration List
- Module [DIO-8/8(FIT)GY, DIO-8/8H(FIT)GY,
DI-16(FIT) GY, DI-16H(FIT)GY or DO-16(FIT)GY]...1
- First Step Guide … 1
- CD-ROM [F&eIT Series Setup Disk] *1…1
- Interface connector plugs...2
*1 The CD-ROM contains various software and User’s Guide (this manual)
Interface connector plugs
Module
DIO-8/8
Devi ce
ID
4567
4567
Y
0123
X
0123
0
1
2
3
4
5
6
7
COM 0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM 1
X
Y
CD-ROM
First step guide
[F&eIT Series Setup Disk]
ii
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
Copyright
Copyright 2001 CONTEC CO., LTD. ALL RIGHTS RESERVED
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this
document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
F&eIT is a registered trademark or trademark of CONTEC CO., LTD. Other company and product
names that are referred to in this manual are generally trademarks or registered trade trademark.
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
iii
Table of Contents
Check Your Package................................................................................................................................i
Copyright.................................................................................................................................................ii
Trademarks..............................................................................................................................................ii
Table of Contents...................................................................................................................................iii
1. BEFORE USING THE PRODUCT 1
About the Module....................................................................................................................................1
Features.............................................................................................................................................1
Functions ..........................................................................................................................................2
Functions and control method by controller connected..................................................................3
Customer Support....................................................................................................................................5
Web Site ...........................................................................................................................................5
Limited One-Year Warranty...................................................................................................................5
How to Obtain Service............................................................................................................................5
Liability ...................................................................................................................................................5
Safety Precautions...................................................................................................................................6
Safety Information ...........................................................................................................................6
Handling Precautions.......................................................................................................................6
Environment.....................................................................................................................................8
Inspection .........................................................................................................................................8
Storage..............................................................................................................................................8
Disposal............................................................................................................................................8
2. MODULE NOMENCLATURE AND SETTINGS 9
Nomenclature of Module Components ..................................................................................................9
Setting a Device ID...............................................................................................................................10
Setup Method .................................................................................................................................10
LED Indicator........................................................................................................................................11
3. CONNECTING TO AN EXTERNAL DEVICE 13
Interface Connector...............................................................................................................................13
How to Connect an Interface Connector.......................................................................................13
Signal Layout on the Interface Connector ....................................................................................14
External I/O Circuits .............................................................................................................................15
Surge Voltage Countermeasures...........................................................................................................18
iv
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
4. USING THE I/O ADDRESS MAP 19
Starting I/O Address..............................................................................................................................19
List of I/O Address Maps......................................................................................................................20
Specifications Common to F&eIT Products.........................................................................................26
Product Information........................................................................................................................26
Digital Filter(Hardware)........................................................................................................................28
Data I/O Operations that Directly Access an I/O Port......................................................................30
Data Input .......................................................................................................................................30
Data Output.....................................................................................................................................31
Monitoring the Output Data...........................................................................................................32
Examples................................................................................................................................................33
Software Mode................................................................................................................................33
5. USING THE MEMORY ADDRESS MAP 35
DIO-8/8x(FIT)GY .................................................................................................................................36
Module Settings Area.....................................................................................................................36
Module Information Area...............................................................................................................39
Basic I/O Data Area........................................................................................................................41
DI-16x(FIT)GY .....................................................................................................................................42
Module Settings Area.....................................................................................................................42
Module Information Area...............................................................................................................45
Basic I/O Data Area........................................................................................................................46
DO-16(FIT)GY......................................................................................................................................47
Module Settings Area.....................................................................................................................47
Module Information Area...............................................................................................................49
Basic I/O Data Area........................................................................................................................50
Examples................................................................................................................................................51
6. USING THE MODULE TO INCREASE THE NUMBER OF DIGITAL USB SERIES55
DIO-8/8x(FIT)GY .................................................................................................................................55
DI-16x(FIT)GY .....................................................................................................................................55
DO-16(FIT)GY......................................................................................................................................56
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
v
7. SYSTEM REFERENCE 57
DIO-8/8x(FIT)GY Circuit Block Diagram ..........................................................................................57
DIO-8/8x(FIT)GY Specifications.........................................................................................................58
DI-16x(FIT)GY Circuit Block Diagram...............................................................................................59
DI-16x(FIT)GY Specifications.............................................................................................................60
DO-16(FIT)GY Circuit Block Diagram...............................................................................................62
DO-16(FIT)GY Specifications .............................................................................................................63
External Dimensions.............................................................................................................................65
vi
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
1. Before Using the Product
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
1
1. Before Using the Product
This chapter provides information you should know before using the product.
About the Module
The Module, which is an interface module that sends and receives digital signals to and from external
devices, can be used by connecting it to F&eIT series controller modules <CPU-CA10(FIT)GY,
CPU-SB10(FIT)GY etc>. The DIO-8/8(FIT)GY, DI-16(FIT)GY, and DO-16(FIT)GY can be
connected to the DIO-8/8(USB)GY, DI-16(USB)GY, and DO-16(USB)GY, respectively, to increase the
number of I/O channels.
Since a opto-coupler is used to insulate the CPU controlling the Module and external signals, it does not
produce external electric effects directly on the host computer.
The <DIO-8/8x(FIT)GY> can perform a maximum of 8 points of input and 8 points of output per
module.
The <DI-16x(FIT)GY> can perform a maximum of 16 points of input per module.
The <DO-16(FIT)GY> can perform a maximum of 16 points of output per module.
By reading this manual carefully, please build a system by creating applications programs, setting the
switches, and connecting the module to external devices.
* This module is available in different product models. "x" in each model number represents a
blank or one alphanumeric character. This is applicable to the rest of this document.
About the Isolated Digital I/O Module
DIO-8/8(FIT)GY, DI-16(FIT)GY : 12 - 24VDC specification
DIO-8/8H(FIT)GY, DI-16H(FIT)GY : 36 - 48VDC specification
DO-16(FIT)GY : 12 - 48VDC specification
Features
- Isolated I/O operations using an opto-coupler improves noise immunity.
- The <DIO-8/8x(FIT)GY> can perform 8-point digital signal input and 8-point digital output,
treating 8 points as a group.
- The <DI-16x(FIT)GY> can perform 16-point digital signal input, treating 8 points as a group and
handling two groups per operation.
- The <DO-16(FIT)GY> can perform 16-point digital signal output, treating 8 points as a group and
handling two groups per operation.
- Input section is ready to accept both the current sinking output and current source output.
- The output section is a high sink current, open collector type using high-capacitance transistors.
<DIO-8/8(FIT)GY> : 150mA/24VDC (par channel)(Max.)
<DIO-8/8H(FIT)GY> : 50mA/48VDC (par channel)(Max.)
<DO-16(FIT)GY> : 150mA/24VDC (par channel)(Max.), 50mA/48VDC (par channel)(Max.)
- A rotary switch allows you to set device IDs to help you keep track of device numbers.
- The system incorporates a screwless connector plug that allows you to easily attach and detach
wires without using any special tools.
- Like other F&eIT series products, the module has a 35mm DIN rail mounting mechanism as
standard. A connection to a controller module can be effected on a lateral, stack basis in a unique
configuration, which permits a simple, smart system configuration without the need for a backplane
board.
1. Before Using the Product
2
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
Functions
Generic I/O functions (data I/O operations that directly access the I/O ports)
- Input
The Module reads a maximum of 16 points (<DI-16x(FIT)GY>) or 8 points (<DIO-8/8x(FIT)GY>) of
externally supplied digital signals in groups, with each group comprising 8 points, and transmits them to
a controller module that is connected to it. Access to the Module from a controller module is
performed through the input port that is specified by means of a Device ID. When an input port is read
by the execution of an input command, the buffer gate associated with the input port is opened, and the
digital signals supplied from an external device are fetched in groups. During this operation, signals
that are transmitted to the controller module will be [ON (closed): 1, OFF (open): 0].
- Output
The Module writes a maximum of 16 points (<DO-16(FIT)GY>) or 8 points (<DIO-8/8x(FIT)GY>) of
digital signals in groups of 8 points to an external device. Access to the Module from a controller
module is performed through the output port that is specified by means of a Device ID. When data is
written to the output port by the execution of an output command, the data is held on the latch circuit
that is associated with the output port. After being electrically isolated by an opto-coupler, the digital
signals are transmitted to the connected external device through transistors. During this operation,
signals that are transmitted to the external device will be [ON (closed): 1, OFF (open): 0]. The data
being held on the latch circuit remains in that state until another execution of the output command.
When the power is turned on or the reset switch is pressed, all output will be in the [OFF] state.
Output data monitoring function
This function allows you to keep track of the signal data that is being output.
1. Before Using the Product
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
3
Functions and control method by controller connected
There DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY can be connected to a variety of controllers.
Micro Controller Unit : CPU-SBxx(FIT)GY
I/O Controller Module : CPU-CAxx(FIT)GY
Monitoring & Control Server Unit : SVR-MMF2(FIT)
Monitoring & Control Server Unit : SVR-MMF(FIT)GY
Isolated Digital I/O Module for USB : DIO-8/8(USB)GY
Isolated Digital Input Module for USB : DI-16(USB)GY
Isolated Digital Output Module for USB : DO-16(USB)GY
I/O Controller Module with USB : CPU-CA10(USB)GY
Check each controller to which the module can be connected as well as the method of controlling the
module when connected to that controller.
Connections to controllers
Connections to controllers
o: Permitted
×: Not permitted
C
P
U
-
S
B
x
x
(
F
I
T
)
G
Y
C
P
U
-
C
A
x
x
(
F
I
T
)
G
Y
S
V
R
-
M
M
F
2(
F
I
T
)
S
V
R
-
M
M
F
(
F
I
T
)
G
Y
D
I
O
-
8/
8
(
U
S
B
)
G
Y
D
I
-
16
(
U
S
B
)
G
Y
D
O
-
16(
U
S
B
)
G
Y
C
P
U
-
C
A
1
0(
U
S
B
)
G
Y
DIO-8/8(FIT)GY
ooooo××o
DIO-8/8H(FIT)GY
oooo×××o
DI-16(FIT)GY
oooo×o×o
DI-16H(FIT)GY
oooo×××o
DO-16(FIT)GY
oooo××oo
Device ID setting range
0 - 7 0 - 7 0 - 7 0 - 7 1 - 3 1 - 3 1 - 3 0 - 7
1. Before Using the Product
4
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
Control method by controller connected
C
P
U
-
S
B
x
x(
F
I
T
)
G
Y
C
P
U
-
C
A
x
x
(
F
I
T
)
G
Y
S
V
R
-
M
M
F
2
(
F
I
T
)
S
V
R
-
M
M
F
(
F
I
T
)
G
Y
D
I
O
-
8
/
8
(
U
S
B
)
G
Y
D
I
-
1
6
(
U
S
B
)
G
Y
D
O
-
1
6
(
U
S
B
)
G
Y
C
P
U
-
C
A
1
0
(
U
S
B
)
G
Y
Control using the I/O address map
o
Control using the memory address map
o
FIT Protocol
o
API-CAP(W32)
o
API-SBP(W32)
o
API-USBP(WDM)
oooo
Control over the web
oo
Control via the Windows driver *
* The API-SBP(W32) is included in the development kit
DTK-SBxx(FIT)GY; the other drivers are bundled with each controller.
Control using the I/O address map
When connected to the CPU-SBxx(FIT)GY, the module can receive I/O instructions directly from the
controller module. For details, see Chapter 4 “Using the I/O Address Map”.
Control using the memory address map
When connected to the CPU-Caxx(FIT)GY, the module) can be accessed from the host computer over
the network. The module is assigned with its device ID in the memory managed by the controller
module. The application running on the host computer controls the module by reading/writing the
memory managed by the controller module. For details, see Chapter 5 “Using the Memory Address
Map”.
Control via the Windows driver
For the functions and settings available when using the Windows driver, refer to the reference manual
and online help for each module.
Control over the web
You can monitor collected data and manage the log over the web. You can use your familiar browser
to easily make various settings. For details, refer to the reference manual for the SVR-MMF2(FIT),
SVR-MMF(FIT)GY.
1. Before Using the Product
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
5
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently
and comfortably.
Web Site
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available in
several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited One-Year Warranty
CONTEC F&eIT products are warranted by CONTEC CO., LTD. to be free from defects in material
and workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office,
from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization number (RMA) from the CONTEC group office where you
purchased before returning any product.
* No product will be accepted by the CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the warrantor
be liable for any incidental or consequential damages due to such defect or consequences that arise from
inexperienced usage, misuse, or malfunction of this device.
1. Before Using the Product
6
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting in
injury or death and the destruction of equipment and resources. Understand the meanings of these
labels to operate the equipment safely.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
Handling Precautions
CAUTION
- Do not modify the module. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this module.
- Do not use or store the equipment in a hot or cold place, or in a place that is subject to severe
temperature changes.
(Operating temperature range: 0 - 50°C)
- Do not use or store the equipment in a place subject to direct sunlight or near a heating device, such
as a stove.
- Do not use or store the equipment in a dusty or humid place.
(Operating humidity range: 10 - 90%RH, No condensation)
- As this product contains precision electronic components, do not use or store in environments
subject to shock or vibration.
- Do not use or store the product near equipment generating a strong magnetic field or radio waves.
- If you notice any strange odor or overheating, please unplug the power cord immediately.
- In the event of an abnormal condition or malfunction, please consult the dealer from whom the
equipment was purchased.
- To avoid electric shock, please do not touch the system with a wet hand.
- Do not open the module casing. CONTEC will disclaim any responsibility for equipment whose
casing has been opened.
- Do not strike or bend the module. Doing so could damage the module.
1. Before Using the Product
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
7
- To prevent contact malfunction, please do not touch the metallic pins on the external module
connector.
- The module contains switches that need to be properly set. Before using the module, please check
its switch settings.
- To avoid malfunction, please do not change the module switch settings in an unauthorized manner.
- Do not operate the device module when the power for the Controller Module is on. To avoid
malfunction, please be sure to turn off the power for the Controller Module.
FCC PART 15 Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in commercial
environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference at his own expense.
NOTE
Change or modifications not expressly approved the manufacturer can void the user's
authority to operate this equipment.
WARNING TO USER
1. Before Using the Product
8
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
Environment
Use this product in the following environment. If used in an unauthorized environment, the board may
overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
DIO-8/8
Device
ID
4567
4567
Y
0123
X
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
X
Y
- Check that the ventilation slit has no obstruction and
has no dust or foreign matter adhering.
Storage
When storing this product, keep it in its original packing form.
(1) Put the board in the storage bag.
(2) Wrap it in the packing material, then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
2. Module Nomenclature and Settings
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
9
2. Module Nomenclature and Settings
Nomenclature of Module Components
Figure 2.1 shows the names of module components.
In the figure, the indicated switch settings represent factory settings.
DIO-8/8(FIT)GY DIO-8/8H(FIT)GY
LED
indicator
DIO-8/8
Device
ID
4567
4567
Y
0123
X
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
Device ID
Input
Output
X
Y
LED
indicator
DIO-8/8H
Device
ID
4567
4567
Y
0123
X
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
Device ID
Input
Output
X
Y
DI-16(FIT)GY DI-16H(FIT)GY
LED
indicator
DI-16
Device
ID
4567
4567
X
0123
X
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
Device ID
Input
X0
X1
LED
indicator
DI-16H
Device
ID
4567
4567
X1
0123
X0
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
Device ID
Input
X0
X1
Figure 2.1. Names of Module Components < 1 / 2 >
2. Module Nomenclature and Settings
10
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
DO-16(FIT)GY
LED
indicator
DO-16
Device
ID
4567
4567
Y
0123
Y
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
Device ID
Output
Y0
Y1
Figure 2.1. Names of Module Components < 2 / 2 >
Setting a Device ID
The controller module distinguishes and keeps track of the modules that are connected to it by assigning
device IDs to them. Each module, therefore, should be assigned a unique ID.
A Device ID can be assigned in a 0 - 7 range, so that a maximum of eight modules can be distinguished.
To connect the module to the USB module, assign a device ID between 1 and 3. The factory setting
for the Device ID is [0].
Setup Method
A Device ID can be set by turning the rotary switch that is located on the module face.
A Device ID can be assigned by turning the switch.
Device
ID
0
4
0
4
6
2
5
1
3
7
Factory setting:
(Device ID = 0)
Figure 2.2. Setting a Device ID
2. Module Nomenclature and Settings
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
11
LED Indicator
DIO-8/8x(FIT)GY
Table 2.1. LED Indicator <DIO-8/8x(FIT)GY>
ON: Output ON
OFF: Output OFF
ON: Output ON
OFF: Output OFF
Name Function LED indicator
Output indicator (Y0 - Y7): red
Input indicator (X0 - X7): green
Status LED
DI-16x(FIT)GY
Table 2.2. LED Indicator <DI-16x(FIT)GY>
Input indicator (X0 - X7, X10 - X17) ON: Input ON
: green OFF: Input OFF
Name Function LED indicator
Status LED
DO-16(FIT)GY
Table 2.3. LED Indicator <DO-16(FIT)GY>
Output indicator (Y0 - Y7, Y10 - Y17) ON: Output ON
: red OFF: Output OFF
Name Function LED indicator
Status LED
2. Module Nomenclature and Settings
12
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
3. Connecting to an External Device
DIO-8/8x(FIT)GY, DI-16x(FIT)GY, DO-16(FIT)GY
13
3. Connecting to an External Device
Interface Connector
How to Connect an Interface Connector
When connecting the Module to an external device, you can use the supplied connector plug. When
wiring the Module, strip off approximately 7 - 8 mm of the covering for the cable, and insert the bare
wire by pressing the orange button on the connector plug. Releasing the orange button after the wire is
inserted fixes the cable. Compatible wires are AWG 28 - 20.
Press this section to insert
the wire material.
7 - 8mm
DIO-8/8
Device
ID
4567
4567
Y
0123
X
0123
0
1
2
3
4
5
6
7
COM0
0
4
0
4
6
2
5
1
3
7
0
1
2
3
4
5
6
7
COM1
X
Y
Applicable plug :
Front-operable spring gauge type
FK-MC0,5/9-ST-2,5 plug(made by Phoenix Contact Corp.)
Applicable wire : AWG 28 - 20
Figure 3.1. Connecting an Interface Connector and Connectors That Can Be Used
CAUTION
Removing the connector plug by grasping the cable can break the wire.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73

Contec DI-16(FIT)GY Owner's manual

Category
Digital & analog I/O modules
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI