Allen-Bradley 140G-G Installation guide

Type
Installation guide
(3)
DIR 1000719R0001 Version 02
3
1
2
4
OK
0.98"/25 mm0.98"/25 mm
3
1,1 Nm
8,9 lb-in
4.21"/107 mm
Ø 0.18"
Ø 4.5 mm-M4
B
D
E
C
A
X
X
Y
Y
Y
Y
X
X
IV ONLY
IV ONL
Y
IV ONL
Y
IV ONL
Y
0.49"/12.5 mm
0.49"/12.5 mm
1.97"/50 mm
2.11"/53.5 mm
IV ONL
Y
NOT REQUIRED FOR
IEC APPLICATIONS
MANDATORY FOR
UL APPLICATIONS
A B C D E
III-IV
3.11"
79 mm
1.69"
43 mm
1.85"
47 mm
0.59"
15 mm
0.93"
23.5 mm
III
2.79"
71 mm
1.85"
47 mm
2.87"
73 mm
0.67"
17 mm
1.44"
36.5 mm
IV
2.79"
71 mm
1.85"
47 mm
3.86"
98 mm
0.67"
17 mm
1.44"
36.5 mm
III
2.91"
74 mm
2.16"
55 mm
3.19"
81 mm
0.83"
21 mm
1.59"
40.5 mm
IV
2.91"
74 mm
2.16"
55 mm
4.17"
106 mm
0.83"
21 mm
1.59"
40.5 mm
WITH ESCUTCHEON
WITHOUT ESCUTCHEON
4
140G-G
140MG-G
7.5
6
A
0.29"
0.24"
A max
min 6,5
Ø min 6,5
0.14"(3.5) min
0.2"(5) max
Ø min 0.26"
max 0.63"
max 16
min 0.26"
Ø 6.5
16
Ø 0.26"
A
0.63"
140G-G THERMOMAGNETIC TRIP UNIT
*IEC ONLY
In
Fixed
Fixed
Fixed
Fixed
Type
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
500
100
110
125
160*
50
60
63
70
80
90
500
500
600
1600112Adjustable
30
32
35
I3
500
500
500
500
630
Min Med Max I3
500
500
136 160
I1
15
16
20
25
30
1250
110
125
32
35
40
50
60
63
700
800
900
1000
1100
Type
70
80
90
100
In
15
16
20
25
40
Fixed
Fixed
Fixed
Fixed
Fixed
1000
I1(A)
100
In=100A
I3(A)
5
ONLY REQUIRED FOR THROUGH THE DOOR APPLICATION
(WITH DOOR OF THE PANEL ≤0.98"/25 mm FROM THE FRONT)
6
1
2
(4)
DIR 1000719R0001 Version 02
7
In A B C D E F G H I
3 from 4 In to 11 In 12 15 17 20 23 25 28 30 33
7 from 4 In to 11 In 28 34 40 46 53 59 65 71 77
15 from 3 In to 11 In 45 60 75 90 105 120 135 150 165
30 from 3 In to 11 In 90 120 150 180 210 240 270 300 330
50 from 3 In to 11 In 150 200 250 300 350 400 450 500 550
70 from 3 In to 11 In 210 280 350 420 490 560 630 700 770
80 from 3 In to 11 In 240 320 400 480 560 640 720 800 880
100 from 3 In to 11 In 300 400 500 600 700 800 900 1000 1100
125 from 3 In to 11 In 375 500 625 750 875 1000 1125 1250 1375
I3
- Manually trip the breaker prior to any adjustment of the magnetic trip settings.
- E’obbligatorio mettere l'interruttore in posizione Trip test prima di regolare il termomagnetico.
- Der Leistungsschalter muss vor Einstellung des thermomagnetischen Auslösers zwingend in die Prüfstellung geschaltet werden.
- Il est obligatoire de mettre le disjoncteur en position de Test de Déclenchement avant de régler le déclencheur magnétothermique.
- Es obligatorio situar el interruptor en posición “Test de Disparo” antes de realizar el ajuste del relé termomagnético.
CLACK
USE FLAT BLADE
SCREW DRIVER
140MG-G MAGNETIC ONLY TRIP UNIT
In=200A
F
C
D
B
E
H
G
A
I
HĊ ĂĖ Å
F G H I
800 900 1000 1100
A B C D E
300 400 500 600 700
2
1
DIR 1000719R0001 Version 02 (L9694) - B0301
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Printed in Italy.
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 140G-IN076C-MU-P - September 2015
Rockwell Automation maintains current product environmental compliance information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/
sustainability-ethics/product-environmental-compliance.page
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Allen-Bradley 140G-G Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI