Champion Power Equipment 41150 User manual

Type
User manual

Champion Power Equipment 41150 is a powerful portable generator that can provide backup power during outages or be used for recreational activities like camping or tailgating. With a running wattage of 4100 watts and a peak wattage of 5000 watts, it can power a variety of appliances and tools, including refrigerators, microwaves, power tools, and more. The generator is powered by a 208cc Champion single-cylinder OHV engine and has a runtime of up to 10 hours at 50% load. It features a convenient electric start, a built-in fuel gauge, and a low-oil indicator light.

Champion Power Equipment 41150 is a powerful portable generator that can provide backup power during outages or be used for recreational activities like camping or tailgating. With a running wattage of 4100 watts and a peak wattage of 5000 watts, it can power a variety of appliances and tools, including refrigerators, microwaves, power tools, and more. The generator is powered by a 208cc Champion single-cylinder OHV engine and has a runtime of up to 10 hours at 50% load. It features a convenient electric start, a built-in fuel gauge, and a low-oil indicator light.

Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to
strict specifications and with proper use and maintenance this generator should bring you years of satisfying service.
Read, study, and follow all instructions before operating this device. Failure to heed these instructions may
result in personal injury and/or property damage.
WARNING
Your generator can develop tremendous power forces and if used unsafely or improperly could result in property damage, serious
injury, or death. Throughout this manual you will find the following symbols for caution, warning, and danger. Pay particular attention to
the notes preceded by these symbols as they are written
for your safety. Ultimately, safe operation of this device rests with you, the
operator.
Indicates a hazard which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury or
equipment damage. This notation is also used to alert against unsafe practices.
CAUTION
SAFETY PRECAUTIONS
SAFETY AND OPERATION INSTRUCTIONS
Failure to follow these instructions and warnings may result in death, personal injury, or property damage.
WARNING
DANGER
Gasoline engines produce toxic carbon monoxide exhaust fumes. Breathing exhaust fumes will cause serious injury
or death.
WARNING
No modifications, alterations, or deviation to the generator are authorized by the manufacturer and should not be made.
Read, study, and understand the operator's manual prior to operation of this product. Read, study and understand the
engine manual prior to operation. Follow all warnings and instructions.
Know your equipment. Check
the applications, limitations, and potential hazards with this unit and its placement or
location.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or
other reproductive harm.
Gasoline is flammable. Check for spilled fuel or fuel leaks. Stop engine and allow to
cool at least 2 minutes before
refueling.
Equipment must be used on a hard, level surface, free from grease, fuel and other combustible materials.
Engine must not be run at excessive speeds. Operating an engine at excessive speeds increases the hazard of personal
injury. Do not tamper with the parts
which may increase or decrease the speed of the engine.
Do not operate this generator in the rain or unusually wet conditions.
This generator is designed for outdoor use only; do not use this generator inside any building or enclosure including the
generator compartment of a recreational vehicle (RV), garages, basements, crawl
spaces and other locations where CO
gas can collect and cause death or injury. Fire or an explosion may result.
No user-performed modifications, including venting of exhaust and/or cooling ventilation are authorized by the
manufacturer, Also, allow at least two feet of clearance on all sides of the generator even
while operating the unit
outdoors.
If this unit is used for backup power in the event of a utility power failure, the following step must be taken: Before
connecting the generator to an electrical system, open the main circuit breaker or main switch serving the system, to
isolate the generator
system from the electric utility. Failure to isolate the generator and utility systems may result in
damage to the generator and may also result in injury or death to electric utility workers, due to a back feed of electrical
energy.
This product is equipped with a spark-arresting muffler. If the
product will be used around flammable materials, or on land
covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then the approved spark
arrester must be installed. SPARK-ARRESTERS ARE REQUIRED IN THE STATE OF CALIFORNIA. Spark arresters are
also required on some U.S. Forest Service
land and may also be legally required under other statutes and ordinances.
Never step over a generator.
Failure to heed these warnings may result in personal injury and/or property damage. No modifications, alterations, or
deviations to the generator are authorized by the manufacturer and should not be made.
Engine speed has been
factory set to provide safe operation. Tampering with the engine speed adjustment could result in
overheating of attachments and could cause a fire. Never attempt to “speed up” the engine to obtain more performance.
Both the output voltage and frequency will be thrown out of standard by this practice,
endangering attachments and the
user.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
DANGER
WARNING
1
VHW
RUNNING WATTAGE GUIDE
Starting loads may need as much as 3 times the Running Wattage for Electrical Motors. Check your appliance rating before using generator.
0 4000500 1000 1500 2000 2500 3000 3500
Air Conditioner (12,000 BTU)
Air Conditioner (20,000 BTU)
Battery Charger 20 AMP
Battery Charger 12V DC
Belt Sander 3”
Bench Grinder 6”
Chain Saw
Circular Saw (6-12”)
Clothes Washer
Coffee Maker
Compressor (1HP)
Compressor HP)
Compressor (3/4 HP)
Curling Iron
Demolition Hammer
Disc Sander (9”)
Edge Trimmer
Electric Blanket
Electrical Nail Gun
Electric Range - One Element
Electric Skillet
Freezer
Furnace Fan (1/3 HP)
Hair Dryer
Hand Drill (1”)
Hand Drill (½”)
Hand Drill (1/4”)
Hand Drill (3/8”)
Hedge Trimmer
Home Security
Impact Wrench
Jet Pump
Jigsaw
Lawn Mower
Light Bulb
Microwave
Milk Cooler
Oil Burner on Furnace
Oil Fired Space Heater (140,000 BTU)
Oil Fired Space Heater (30,000 BTU)
Oil Fired Space Heater (85,000 BTU)
Paint Sprayer, Airless (1/3
HP)
Paint Sprayer, Airless (handheld)
Portable Heater (5,000 BTU)
Radio
Refrigerator
Refrigerator/Freezer
Slow Cooker
Small Refrigerator
Submersible Pump (1 HP)
Submersible Pump HP)
Submersible Pump (1-1/2 HP)
Sump Pump
Table Saw
Television
Toaster Oven
Water Heater
Weed Trimmer
1700
3300
500
110
1000
700
1200
800
1200
1000
2000
1400
1800
700
1300
1200
500
230
1200
1500
1250
500
1200
1200
1100
750
250
500
450
100
500
800
550
1200
100
700
1100
300
400
150
225
600
150
1550
50
600
1200
200
500
2000
1500
2800
600
1750
400
1500
4000
500
4
E)L[D[OHWRIRXUD[OHPRXQWLQJKROHVRQFUDGOHIUDPHE\IRXUEROWVDVVKRZQ)LJ
&
8
SERVICE INFORMATION
A = Intermittent use (less than 1 hour) or colder temperatures, below 60°F
B = Medium use (less than 3 hours) or seasonal temperatures 50°F 80°F
C = Extreme use (continuous use) or hot climates 80°F-100°F
Spark Plug, NGK or equivalent
Spark Plug Gap
Valve Clearance, Cold
A B6ES
B B7ES C B8ES
0.70 / 0.80mm (.028 / .031 in.)
Intake 0.13 / 0.17mm (.005 / .007 in.)
Exhaust 0.18 / 0.22mm (.007 / .009 in.)
ADDING / CHECKING OIL LEVEL
1)Remove oil fill cap / dipstick to add oil
2)Add 1.6 qts. (1.1 L) oil and replace cap / dipstick
3)To check oil level - remove cap/dipstick and wipe it clean. Insert
cap/dipstick into the filler, but do NOT screw it in. Oil should
appear
on dipstick.
4)If more oil is required add slowly
5)Oil should be filled at least to the bottom of the threads but not above the
top of the threads when on a level surface.
MAXIMUM FILL
MINIMUM FILL
DRAIN PLUG
DIP STICK
CAUTION
This engine is equipped with a “low oil shut-off” and the engine will stop when engine oil falls below the minimum safe
level. Add oil immediately then restart engine.
CHECK ENGINE OIL LEVEL DAILY AND ADD AS NEEDED!
REGULAR SERVICE PERIOD : Perform at every indicated month or operating hour interval, whichever comes first.
EACH USE
FIRST
MONTH OR
5 HOURS
FIRST 10
HOURS
EVERY
3 MONTHS
OR 50 HOURS
EVERY
6 MONTHS
OR 100 HRS
ITEM
Check level
Change
Check
Clean
Clean
Clean-Readjust
Check-Readjust
Clean
Clean
Replace if necessary
Engine Oil
Air Cleaner
Sediment cup
Spark plug
Valve clearence*
Spark Arrester
Fuel tank and filter*
Fuel Line
Every 3 years
°F-20 0 20 40 60 80 100 120
10W-30
5W-30
30
MAINTENANCE SCHEDULE:
* Recommended for experienced owner or service center.
Tampering with the factory set governor could void your warranty.
Improper maintenance will void your warranty.
1R 3DUW 'HVFULSWLRQ 4W\
67)' 6ZLWFK
67)'& &RQWURO3DQHO
67)'
$&$%UHDNHU
$&$%UHDNHU
'&$%UHDNHU
67)' 9ROW0HWHU
67)'& '&5HFHSWDFOH
67)'& '&5HFHSWDFOH
67)'& $&5HFHSWDFOH
67)'& (DUWK7HUPLQDO
67
)' &DVH
 *% %ROW0î
 67)' *HQHUDWRU(QG&RYHU
 *% %ROW0î
 67) 7HUPLQDO
 67)$ 'LRGH$VV\
 67)$ $95
 67)' %UXVK$VV\
 67)' (QG&RYHU
 *% )ODQJH%ROW0î
 67)' 6WDWRU&RYHU
 *
% )ODQJH%ROW0îî
 67)' 6WDWRU$VV\
 67)' 5RWRU&RPS
 67)' &RYHU
 67)'% &UDQNFDVH&RYHU
 673) 25LQJ
 67) 2LO)LOOHU&DS
 67)' (QJLQH
 67)'% +DQGOH
 67)'% )UDPH
 67)'$ %RWWRP
5XEEHU
 67)'% %RWWRP5XEEHU
 *% 1XW0
 *%7 5HWDLQ3LQî
 *% :DVKHU ĭ
 67)' :KHHO6ROLG
 *% 1XW0
 *% %ROW0î
 67) &OLS
 67)'&3( )XHO7XEH
 67)' )XHO&RFN
 67)' )XHO7DQN
 67) )XHO)LOWHU
 67)' )XHO7DQN&DS
 *% 6FUHZ0î
 67)' )XHO0HWHU$VV\
 *% %ROW0î
 *% :DVKHU ĭ
 67)' 7DQN5XEEHU
 67)' 5XEEHU7XEH
 67)' &OLS
 67)' 9DOYH
 67)' 5XEEHU7XEH
 *% 6FUHZ0î
 67)' 'LDSKUDJP$VV\
 67)' 3DFNLQJ
 67)' 6WD\$VV\
 67) *URPPHW
 67)'&3( &DUEXUHWRU
 67)' &DUEXUHWRU,QVXODWRU
 67)' &DUEXUHWRU,QVXODWRU3DFNLQJ
 67)' %ROW
 67)' $LU&OHDQHU6WD\
 67)' $LU
&OHDQHU&DVH&RPS
 67)' $LU&OHDQHU6HDO
 *% 1XW0
 67)' 6HSDUDWRU
 67)' (OHPHQW
 67)' $LU&OHDQHU&RYHU&RPS
 *% 1XW0
 67)' &RQWURO$VV\
 67)' %ROW
 67)' 0XIIOHU*DVNHW
 67)' ([3LSH
 *% %ROW0î
 67)' 0XIIOHU
 67)' 0XIIOHU2XWHU3URWHFWRU
 *% %ROW0î 
 67)' 0XIIOHU/LIH3URWHFWRU
 67)' 0XIIOHU,QQHU3URWHFWRU
 *% %ROW0î
 67)' 0XIIOHU6WD\
 *
% %ROW0î
 67)'& 9LEUDWLRQ0RXQW
 67)'& 6XSSRUW/HJ
 67)' $[OHLQ

6$
6SDUN$UUHVWHU&RPS
6$
6$
1R 3DUW 'HVFULSWLRQ 4W\


  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Champion Power Equipment 41150 User manual

Type
User manual

Champion Power Equipment 41150 is a powerful portable generator that can provide backup power during outages or be used for recreational activities like camping or tailgating. With a running wattage of 4100 watts and a peak wattage of 5000 watts, it can power a variety of appliances and tools, including refrigerators, microwaves, power tools, and more. The generator is powered by a 208cc Champion single-cylinder OHV engine and has a runtime of up to 10 hours at 50% load. It features a convenient electric start, a built-in fuel gauge, and a low-oil indicator light.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI