BCM 4.0 for BCM1000 Installation and
Maintenance Guide Addendum
Copyright © 2006 Nortel Networks, All Rights Reserved
All rights reserved.
The information in this document is subject to change without notice. The statements, configurations, technical data, and
recommendations in this document are believed to be accurate and reliable, but are presented without express or implied
warranty. Users must take full responsibility for their applications of any products specified in this document. The
information in this document is proprietary to Nortel Networks.
Trademarks
Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks.
Microsoft, MS, MS-DOS, Windows, and Windows NT are trademarks of Microsoft Corporation.
All other trademarks and registered trademarks are the property of their respective owners.
3
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Subject to the terms hereinafter set forth, NORTEL NETWORKS grants
to CUSTOMER and/or its representatives, with a "need to know," a
personal, non-exclusive license (1) to use the licensed software,
proprietary to NORTEL NETWORKS or its suppliers and (2) to use the
associated documentation. CUSTOMER is granted no title or ownership
rights, in or to the licensed software, in whole or in part, and CUSTOMER
acknowledges that title to and all copyrights, patents, trade secrets and/or
any other intellectual property rights to and in all such licensed software
and associated documentation are and shall remain the property of
NORTEL NETWORKS and/or NORTEL NETWORKS’ suppliers. The
right to use licensed software may be restricted by a measure of usage of
applications based upon number of lines, number of ports, number of
terminal numbers assigned, number of users, or some similar measure.
Expansion beyond the specified usage level may require payment of an
incremental charge or another license fee.
NORTEL NETWORKS considers the licensed software to contain "trade
secrets" of NORTEL NETWORKS and/or its suppliers. Such "trade
secrets" include, without limitation thereto, the specific design, structure
and logic of individual licensed software programs, their interactions with
other portions of licensed software, both internal and external, and the
programming techniques employed therein. In order to maintain the "trade
secret" status of the information contained within the licensed software,
the licensed software is being delivered to CUSTOMER in object code
form only.
NORTEL NETWORKS or any of its suppliers holding any intellectual
property rights in any licensed software, and/or any third party owning
any intellectual property rights in software from which the licensed
software was derived, are intended third party beneficiaries of the License.
All grants of rights to use intellectual property intended to be
accomplished by this License are explicitly stated. No other grants of such
rights shall be inferred or shall arise by implication.
CUSTOMER warrants to NORTEL NETWORKS that CUSTOMER is
not purchasing the rights granted by this License in anticipation of
reselling those rights.
CUSTOMER shall:
Hold the licensed software in confidence for the benefit of NORTEL
NETWORKS and/or NORTEL NETWORKS’ suppliers using no
less a degree of care than it uses to protect its own most confidential
and valuable information; and
Keep a current record of the location of each copy of licensed
software made by it; and
Install and use each copy of licensed software only on a single CPU
at a time (for this purpose, single CPU shall include systems with
redundant processing units); and
Affix to each copy of licensed software made by it, in the same form
and location, a reproduction of the copyright notices, trademarks, and
all other proprietary legends and/or logos of NORTEL NETWORKS
and/or NORTEL NETWORKS’ suppliers, appearing on the original
copy of such licensed software delivered to CUSTOMER; and retain
the same without alteration on all original copies; and
Issue instructions to each of its authorized employees, agents and/or
representatives to whom licensed software is disclosed, advising
them of the confidential nature of such licensed software and to
provide them with a summary of the requirements of this License; and
Return the licensed software and all copies through an Authorized
Distributor to NORTEL NETWORKS at such time as the
CUSTOMER chooses to permanently cease using it.
CUSTOMER shall not:
Use licensed software (i) for any purpose other than CUSTOMER’s
own internal business purposes and (ii) other than as provided by this
License; or
Allow anyone other than CUSTOMER’s employees, agents and/or
representatives with a "need to know" to have physical access to
licensed software; or
Make any copies of licensed software except such limited number of
object code copies in machine readable form only, as may be
reasonably necessary for execution or archival purposes only; or
Make any modifications, enhancements, adaptations, or translations
to or of licensed software, except as may result from those
CUSTOMER interactions with the licensed software associated with
normal use and explained in the associated documentation; or
Attempt to reverse engineer, disassemble, reverse translate,
decompile, or in any other manner decode licensed software, in order
to derive the source code form or for any other reason; or
Make full or partial copies of any documentation or other similar
printed or machine-readable matter provided with licensed software
unless the same has been supplied in a form by NORTEL
NETWORKS intended for periodic reproduction of partial copies; or
Export or re-export licensed software and/or associated
documentation by downloading or otherwise from the fifty states of
the United States and the District of Columbia.
PLEASE REFER TO THE NEXT PAGE
SOFTWARE LICENSE
NORTEL NETWORKS INC. (“NORTEL NETWORKS”) TELECOMMUNICATION PRODUCTS
THIS LEGAL DOCUMENT IS A LICENSE AGREEMENT ("License") BETWEEN YOU, THE END-USER
("CUSTOMER") AND NORTEL NETWORKS. PLEASE READ THIS LICENSE CAREFULLY BEFORE USING
THE SOFTWARE. BY USING THIS SOFTWARE, YOU, THE CUSTOMER, ARE AGREEING TO BE BOUND BY
THE TERMS OF THIS LICENSE. IF YOU DO NOT AGREE TO THE TERMS OF THIS LICENSE, RETURN THE
UNUSED SOFTWARE AND THE ASSOCIATED DOCUMENTATION TO NORTEL NETWORKS THROUGH A
NORTEL NETWORKS AUTHORIZED DISTRIBUTOR WITHIN FIVE (5) DAYS OF YOUR ACQUISITION OF
THE SOFTWARE FOR A REFUND.
N0060603
4
Except for Java Product (as defined herein below), CUSTOMER may
assign collectively its rights under this License to any subsequent owner
of the associated hardware, but not otherwise, subject to the payment of
the then current license fee for new users, if any. No such assignment shall
be valid until CUSOMTER (1) has delegated all of its obligations under
this License to the assignee; and (2) has obtained from the assignee an
unconditional written assumption of all such obligations; and (3) has
provided NORTEL NETWORKS a copy of such assignment, delegation
and assumption; and (4) has transferred physical possession of all licensed
software and all associated documentation to the assignee and destroyed
all archival copies. Except as provided, neither this License nor any rights
acquired by CUSTOMER through this License are assignable. Any
attempted assignment of rights and/or transfer of licensed software not
specifically allowed shall be void and conclusively presumed a material
breach of this License.
If NORTEL NETWORKS (i) claims a material breach of this License, and
(ii) provides written notice of such claimed material breach to
CUSTOMER and (iii) observes that such claimed material breach remains
uncorrected and/or unmitigated more than thirty (30) days following
CUSTOMER’s receipt of written notice specifying in reasonable detail
the nature of the claimed material breach, then CUSTOMER
acknowledges that this License may be immediately terminated by
NORTEL NETWORKS and CUSTOMER further acknowledges that any
such termination shall be without prejudice to any other rights and
remedies that NORTEL NETWORKS may have at law or in equity.
EXPRESS LIMITED WARRANTIES FOR ANY ITEM OF LICENSED
SOFTWARE, IF ANY, WILL BE SOLELY THOSE GRANTED
DIRECTLY TO CUSTOMER BY DISTRIBUTOR. OTHER THAN AS
SET FORTH THEREIN, THIS LICENSE DOES NOT CONFER ANY
WARRANTY TO CUSTOMER FROM OR BY NORTEL NETWORKS.
THE LICENSED SOFTWARE IS PROVIDED BY NORTEL
NETWORKS "AS IS" AND WITHOUT WARRANTY OF ANY KIND
OR NATURE, WRITTEN OR ORAL, EXPRESS OR IMPLIED,
INCLUDING (WITHOUT LIMITATION) THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE.
THIS LIMITATION OF WARRNATIES WAS A MATERIAL
FACTOR IN THE ESTABLISHMENT OF THE LICENSE FEE
CHARGED FOR EACH SPECIFIC ITEM OF SOFTWARE
LICENSED.
IN NO EVENT WILL NORTEL NETWORKS AND/OR NORTEL
NETWORKS’ SUPPLIERS AND THEIR DIRECTORS, OFFICERS,
EMPLOYEES OR AGENTS BE LIABLE TO OR THROUGH
CUSTOMER FOR INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL, PUNITIVE, OR EXEMPLARY DAMAGES OF
ANY KIND, INCLUDING LOST PROFITS, LOSS OF BUSINESS OR
BUSINESS INFORMATION, BUSINESS INTERRUPTION, OR
OTHER ECONOMIC DAMAGE, AND FURTHER INCLUDING
INJURY TO PROPERTY, AS A RESULT OF USE OR INABILITY TO
USE THE LICENSED SOFTWARE OR BREACH OF ANY
WARRANTY OR OTHER TERM OF THIS LICENSE, REGARDLESS
OF WHETHER NORTEL NETWORKS AND/OR NORTEL
NETWORKS’ SUPPLIERS WERE ADVISED, HAD OTHER REASON
TO KNOW, OR IN FACT KNEW OF THE POSSIBILITY THEREOF.
Restricted Rights. Use, duplication or disclosure by the United States
government is subject to the restrictions as set forth in the Right in
Technical Data and Computer Software Clauses in DFARS
252.227-7013(c) (1) (ii) and FAR 52.227-19(c) (2) as applicable.
The rights and obligations arising under this License shall be construed in
accordance with the laws of the State of Tennessee. If for any reason a
court of competent jurisdiction finds any provision of this License or
portion thereof to be unenforceable, that provision of the License shall be
enforced to the maximum extent permissible so as to effect the intent of
the parties and the remainder of this License shall continue in full force
and effect.
This License constitutes the entire agreement between the parties with
respect to the use of the licensed software and the associated
documentation, and supersedes all prior or contemporaneous
understandings or agreements, written or oral, regarding such subject
matter. No amendment to or modification of this License will be binding
unless in writing and signed by a duly authorized representative of
NORTEL NETWORKS.
Contents 5
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Contents
Chapter 1
About this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
How to use this addendum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
What’s new in BCM 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 2
Documentation updates for BCM 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
General changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Page 3, Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Page 22, Data networking components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Page 23, MSC IP call processing hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Page 33, Chapter 2, Telephony hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Page 44, Analog station modules and analog devices . . . . . . . . . . . . . . . . . . . . . . . . 12
Page 52, Legacy mobility equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Page 55, Chapter 3, Auxiliary equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Page 64, Explaining double density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 64, Setting offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 69, Environment checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 70, Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 88, Double density example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 110, Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Performing a system shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pages 126–131, Setting initial system configurations . . . . . . . . . . . . . . . . . . . . . . . . . 16
Pages 131, Entering the software keycodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Pages 144-146, Telephone port and DN cross-reference . . . . . . . . . . . . . . . . . . . . . . 16
Pages 160–161, New chapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Pages 168–169, Shutting down the system software and
Shutting down the system hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Page 171, Software restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Page 179, Initializing the hard disk (single-disk system BCM 2.5/2.5.1) . . . . . . . . . . . 17
Page 182, Initializing the hard disk (single-disk system BCM 3.0) . . . . . . . . . . . . . . . 18
Page 184, Initializing the hard disk (single-disk system BCM 3.01
and newer systems) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Initializing the hard disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Page 196, Controlling and monitoring mirroring operations . . . . . . . . . . . . . . . . . . . . 18
Page 229, Determining the status of a telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Page 230, Moving telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Page 233, Appendix A, Defining region-based defaults . . . . . . . . . . . . . . . . . . . . . . . 20
Page 254, Set DNs and port numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6 Contents
N0060603N0060603
Appendix A
Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
About this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Symbols and conventions used in this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
How to get help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Appendix B
Initializing the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Data parameter requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Using the default BCM system IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Using the Ethernet crossover cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Setting the crossover connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Connecting through Ethernet crossover cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Connecting through the serial port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Null modem cable setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
To display the configuration menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Software keycode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Regenerating a keycode after system replacement . . . . . . . . . . . . . . . . . . . . . . . 34
Next step . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Appendix C
Configuring the BCM system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Initial parameters overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Startup parameters overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Appendix D
Using Telset Administration to set the basic parameters . . . . . . . . . . . . . 39
Configuring the initial parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Next step . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Appendix E
Using Element Manager to set the basic parameters. . . . . . . . . . . . . . . . . 45
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Accessing the BCM system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Configuring the initial parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Configuring the startup parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Next step . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Contents 7
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Appendix F
Completing the initial installation (optional) . . . . . . . . . . . . . . . . . . . . . . . . 57
Configuring the media bay module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Configuring modem settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Checking for software updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Configuring voice mail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Customizing security policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Performing a backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Appendix G
Market profile attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Media bay module availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
FEM MBM–Norstar trunk cartridge combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Time zones and language information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Time and date format based on language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Language support for South America and Central America . . . . . . . . . . . . . . . . . 64
Caller ID display formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Core parameters for market profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Global analog trunk parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
GASM8 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
ISDN line services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Analog and digital trunk types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
8 Contents
N0060603N0060603
9
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Chapter 1
About this document
The purpose of this addendum is to provide updates to the BCM1000 Installation and Maintenance
Guide (N0008587 01) for the release of BCM 4.0 software.
For information on upgrading to BCM 4.0 software, refer to the Upgrade Guide for BCM 4.0.
How to use this addendum
To perform installation and maintenance of a BCM1000 system running BCM 4.0 software, use
the BCM1000 Installation and Maintenance Guide (N0008587 01) for BCM 3.7 as the main
document. Then refer to this addendum for updates and changes to the installation and
maintenance information for BCM 4.0 software.
What’s new in BCM 4.0
The primary changes from BCM 3.7 to BCM 4.0 are:
Operating system: A Linux operating system (OS) replaces Windows NT® Embedded for
BCM 4.0 systems.
Element Manager: Element Manager replaces Unified Manager as the primary BCM
management tool. Use Element Manager to configure a BCM 4.0 system; Unified Manager
does not function with a BCM 4.0 system. If you need to configure a pre-BCM 4.0 system (for
example, BCM 3.6/3.7), then you must use Unified Manager; Element Manager does not
function with a pre-BCM 4.0 system.
New IP Phone support: BCM 4.0 supports the following new IP Phones: 1120, 1140, 2007,
2033, WLAN handset 2212, and the IP Phone KEM.
Administrator account: In a BCM 4.0 system, the default administrator account is nnadmin,
instead of ee_admin, and the password is PlsChgMe!.
Keycode functionality: You no longer require a keycode for each feature; you now require
only one keycode to enable software features on the BCM 4.0 system. The single keycode is
generated from multiple feature selections using the Nortel keycode retrieval system (KRS).
Market profiles and software loads: In BCM 4.0, there are only three software loads (instead
of the five for BCM 3.7); T1 CT2 and E1 CALA are removed. If the BCM 3.6/3.7 system was
running a T1 CT2+ load then it is upgraded with a T1 Etiquette load and if it was running an
E1 CALA load, then it is upgraded with an E1 Global load. These changes are automatically
implemented as part of the upgrade process; no user intervention is required.
Telset administration: BCM 4.0 supports Telset administration (see BCM 4.0 Telset
Administration Guide).
USB support: BCM 4.0 adds support for USB ports on the BCM200/400 systems (not
supported on BCM1000). This support includes file loading and UPS connection through the
USB port.
10 Chapter 1 About this document
N0060603N0060603
UPS support over USB: UPS connectivity through the USB port is supported in BCM 4.0 for
the BCM200/400 system for graceful shutdown (not supported on BCM1000).
Multimedia Contact Center: All custom files (html and txt) are case sensitive and must
match the format shown in default interface folder in CallPilot Manager after upgrading to
BCM 4.0. All custom interfaces created in BCM 3.6/3.7 are also case sensitive and must match
the format shown in CallPilot Manager after upgrading to BCM 4.0.
Note: The Startup Profile is not available for BCM1000 systems.
11
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Chapter 2
Documentation updates for BCM 4.0
This section provides updates to the BCM1000 Installation and Maintenance Guide
(N0008587 01).
General changes
The following changes apply throughout the document, even if not specifically identified:
Replace references to Unified Manager with Element Manager. Any related procedures are
documented, since Element Manager functions differently than Unified Manager.
•The Programming Operations Guide for BCM 3.7 does not exist in BCM 4.0. The content can
be found in the BCM 4.0 Administration Guide and the BCM 4.0 Networking Configuration
Guide.
You can also refer to the online Help within Element Manager for information on using
Element Manager to configure and maintain your system.
The Quick Start wizard (available in BCM 3.7) is not supported in BCM 4.0. The initial
configuration of the system is done using Element Manager.
Page 3, Preface
This chapter should be replaced with the chapter, “Getting started” on page 21.
Page 22, Data networking components
The sentence, “Modem card (North American systems only) — a V.90 modem that sends and
receives data using the public telephone system,”
should be, “Modem card (North American systems only) — a (V.90 or V.92) modem that sends
and receives data using the public telephone system.”
Page 23, MSC IP call processing hardware
The first bullet should be replaced with the following information.
DS30 buses are internal communication paths controlled by the MSC. Each DS30 bus
provides a possible 32 signaling channels (B1 and B2) and 32 media channels. In BCM 3.0
software, the B2 channels were reconfigured as B1 channels for station modules. As a result,
DS30 02 to 07 were configured to support 32 telephones on each bus configured with
DSM16+, DSM32+ modules set to double density. The ASM 8 module could also be
supported on all four offsets as of that software release.
12 Chapter 2 Documentation updates for BCM 4.0
N0060603N0060603
Page 33, Chapter 2, Telephony hardware
The following information should be deleted.
BCM 3.0 software introduced the concept of Full Double Density (FDD) and Partial Double
Density (PDD). On the default system, DS30 02 to 05 were defaulted to FDD, which provides 32
new ports for connecting digital telephones. To use the FDD feature, DSM16+, DSM32+ media
bay modules are configured to double density. DS30 06 and 07 default to PDD, but can be
configured to FDD.
Page 44, Analog station modules and analog devices
Table 6, Analog engineering specifications, should be replaced with the table below:
Warning: Changing DS30 06 and 07 to FDD
Once you change DS30 06 and 07 to FDD, Companion telephones can no longer
be supported. This change cannot be reversed.
Table 6 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 1 of 2)
Specification ATA2 ASM8 ASM8+ GASM8 GASI
Ringing frequency
(North America)
20 Hz ± 1 Hz 20 Hz ± 1 Hz 20 Hz ±1 Hz 20 Hz ±1 Hz 20 Hz ±1 Hz
Ringing frequency
(Europe)
25 Hz
± 1 Hz 25 Hz ± 1 Hz 25 Hz ± 1 Hz 25 Hz ± 1 Hz 25 Hz ± 1 Hz
Ringing voltage (North
America)
80 V rms
± 10% 55 V rms ± 10% 65 V rms ± 10% 65 V rms ± 10% 65 V rms ± 10%
Ringing voltage
(Europe)
75 V rms +/-
10%
N/A 65 V rms
± 10% 65 V rms ± 10% 65 V rms ± 10%
Loop current 20 mA minimum 20 mA minimum 20 mA minimum 20 mA minimum 20 mA minimum
Battery feed voltage -48 V dc
± 10% -48 V dc ± 10% -29 V dc ± 10% -48 V dc ± 10% -48 V dc ± 10%
FIC code OL13ABC N/A N/A N/A N/A
Ringer equivalency
number
31222
ATA2 to BCM loop
resistance (cable only)
135 ohms
(800 m of
0.5-mm wire or
2600 ft of 24
AWG wire)
N/A N/A N/A N/A
Analog loop resistance
on terminal side for
voice applications
(cable only)
1300 ohms
(7200 m of
0.5-mm wire or
26000 ft of 24
AWG wire)
250 ohms (1538
m of 0.5-mm
wire or 5000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
Analog loop resistance
on terminal side for
data applications
(cable only)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
250 ohms (1538
m of 0.5-mm
wire or 5000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
Chapter 2 Documentation updates for BCM 4.0 13
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Page 52, Legacy mobility equipment
This section should be removed.
The listed equipment, NetVision, Companion, and DECT, is not supported in BCM 4.0 (DECT is
still supported in European markets).
Page 55, Chapter 3, Auxiliary equipment
The first two paragraphs should be removed and replaced with the following information:
You require a personal computer to run Element Manager. You use Element Manager to configure
and manage the BCM system through a connection between your computer and the BCM system
(either through the LAN or using an Ethernet crossover cable). To work with Element Manager,
you require the correct version of Element Manager installed on your computer.
The computer you will use to run Element Manager must meet the following requirements:
Operating system: Windows 98SE, Windows 2000, Windows XP
RAM: minimum 256 MB (512 MB recommended)
Disk space: 150 MB
Browser: Internet Explorer (IE) 5.5 or IE 6.0 (recommended)
Input impedance at tip
and ring
600 ohms 600 ohms 600 ohms 600 ohms 600 ohms
Return loss > 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
Insertion loss on an
internal call
ATA2 to BCM
loss 3.0 dB
± 0.5
dB
ATA2 to BCM
loss 3.0 dB ± 0.5
dB
ATA2 to BCM
loss 3.0 dB ± 0.5
dB
ATA2 to BCM
loss 3.0 dB ± 0.5
dB
ATA2 to BCM
loss 3.0 dB ± 0.5
dB
Insertion loss on an
external call
ATA2 to BCM
loss 2.2 dB +/-
1.0 dB; BCM to
ATA2 loss 0.5 dB
± 1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
± 1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
± 1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
± 1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
± 1.0 dB
MWI type (see Note) Stutter tone Stutter tone Stutter tone/
/ Voltage MWI
(CO: 120 V)
Stutter tone/
Reverse polarity/
Voltage MWI
(CO: 120 V)
Stutter Tone/
Reverse polarity/
Voltage MWI
(PBX: 90 V)
Disconnect
supervision types
N/A N/A OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
N/A
Note: The MWI type depends on the country profile, and the MWI voltage shown is a maximum value.
Table 6 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 2 of 2)
Specification ATA2 ASM8 ASM8+ GASM8 GASI
14 Chapter 2 Documentation updates for BCM 4.0
N0060603N0060603
Element Manager access is also supported through a Citrix server
For information on downloading and installing Element Manager, refer to “Using Element
Manager to set the basic parameters” on page 45.
Page 64, Explaining double density
The paragraph at the top of page 64 should be deleted, since Companion is not supported and PDD
is not required.
Default BCM 3.0 and newer systems are configured as Partial Double Density (PDD) systems, in
that they maintain DS30 06 and 07 in the original configuration of 16 DNs per bus. This
accommodates those systems which use Companion. The system can be set to Full Double Density
(FDD) at system startup or once the system is setup. When the system is set to FDD, DS30 06 and
07 allow access to the second set of DNs, and they are no longer available for Companion
operation.
Page 64, Setting offsets
The following paragraph should be changed as follows:
For station modules, each bus supports 16 telephones or telephony devices for station modules that
support single density, or which are set to single density in the case of the DSM16+ and DSM32+,
or on DS30 06 and 07 if the system remains set to Partial Double Density (PDD)
. On each bus that
supports double density, DSM16+ and DSM32+ modules set to double density have access to
eight telephones per offset, for a total of 32 telephones per DS30 bus if the offsets are fully loaded.
Page 69, Environment checklist
The fourth bullet should be replaced with the following:
within the temperature ranges of 0°C and 40°C (32°F and 104°F)
Page 70, Electrical requirements
The second bullet should be replaced with the following:
The supplied power must be 100/240 V AC, 50/60 Hz, and 10 A minimum service with a
third-wire safety ground. The third-wire safety ground provides shock protection and prevents
electromagnetic interference.
Page 88, Double density example
Figure 38 should be deleted.
Chapter 2 Documentation updates for BCM 4.0 15
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Page 110, Shutting down the system
The procedure about how to shut down the system should be replaced with the following section.
Performing a system shutdown
If there is a need to perform maintenance, the system may already be powered down. If this is the
case, proceed to “To shutdown the system hardware” on page 16.
If the system is still operating, perform the following procedures:
“To shut down the system software” on page 15
“To shutdown the system hardware” on page 16
To shut down the system software
1 Check for a recent backup of the BCM system programming.
2 If there is no recent backup, use Element Manager to back up the system data. For information
about backing up the system data, refer to the BCM 4.0 Administration Guide.
3 In Element Manager, from the Administration tab, click the Utilities folder to expand it.
4 From the Utilities folder, select Reset.
5 Click Shutdown System to prepare the system for power disconnect.
This action will stop all services. All Element Manager sessions will be disconnected from the
system. The BCM system can be restored to service only by powering the BCM system off and
back on again.
6 Click Ok.
The progress update dialog box appears and the BCM system begins the shutdown process.
When the shutdown process is complete, the final warning dialog box appears, and the LEDs
enter the flashing state.
7 Click Ok to disconnect Element Manager.
When the shutdown Element Manager is disconnected, the system gives an audible beep. The
LEDs remain in the flashing state until the hardware is shutdown (see “To shutdown the
system hardware” on page 16).
If the system hardware is not shutdown within about 15 minutes, it automatically boots up
again.
16 Chapter 2 Documentation updates for BCM 4.0
N0060603N0060603
To shutdown the system hardware
1 Remove the DS256 cables from the front of the BCM main unit and, if present, the expansion
unit. This includes the data connections on the MSC.
Mark the cables to ensure correct reconnection.
2 Turn off the power switch located at the back of the BCM main unit and expansion unit.
3 Disconnect the BCM main unit and expansion unit power cords from the AC outlet.
4 Ensure you have room to access the part you are working on. Remove the BCM main unit
from the rack, if necessary.
Pages 126–131, Setting initial system configurations
This section should be removed. The initial system configuration will be done after the rest of the
equipment is installed.
Pages 131, Entering the software keycodes
This section should be removed. The keycode feature is discussed in another section of the
addendum.
Pages 144-146, Telephone port and DN cross-reference
The Note on page 144 should be modified as follows.
Warning: Remove all of the connections to the BCM system before you power down the
system.
Failure to disconnect lines before you power down the system can cause damage to the
system.
Warning: You must disconnect power from the main unit after you have performed an
Element Manager shutdown. The main unit cannot start operating again until after power
has been disconnected and then reconnected.
Note: The following table is based on a system with three-digit DNs, with a start
DN of 221. If your system has longer DNs, the system automatically adds a repeat
of the first digit for each additional DN length unit. i.e. 221 becomes 2221. Also,
note on the tables below that DN numbering differs between systems that were
upgraded from BCM 2.5 software and systems that were new with BCM 3.0 or
newer software.
Chapter 2 Documentation updates for BCM 4.0 17
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
In Tables 37 and 38 on page 145 and 146 respectively, the references to PDD should be deleted.
Pages 160–161, New chapters
The following chapters should be inserted between Chapter 13, “Installing optional telephony
equipment” and Chapter 14, “Troubleshooting.” These chapters are located at the back of this
addendum (the chapters should be viewed in the order given):
“Initializing the system” on page 29
“Configuring the BCM system” on page 35
“Using Telset Administration to set the basic parameters” on page 39
“Using Element Manager to set the basic parameters” on page 45
“Completing the initial installation (optional)” on page 57
Pages 168–169, Shutting down the system software and
Shutting down the system hardware
These sections should be replaced with the information in this section,“Page 110, Shutting down
the system” on page 15.
Page 171, Software restart
This procedure should be changed to:
If you did not shut down the system, restart the software:
1 In Element Manager, from the Administration tab, click the Utilities folder to expand it.
2 From the Utilities folder, select Reset.
3 Click Reboot BCM System to reboot the system.
Page 179, Initializing the hard disk (single-disk system BCM
2.5/2.5.1)
This section should be removed.
Warning: When you restart the system, all IP clients, voice mail, and VoIP ports
are not available until the system services restart.
If you have a mirrored disk system, once the services restart, the system
automatically ensures the mirrored disk is updated.
18 Chapter 2 Documentation updates for BCM 4.0
N0060603N0060603
Page 182, Initializing the hard disk (single-disk system BCM
3.0)
This section should be removed.
Page 184, Initializing the hard disk (single-disk system BCM
3.01 and newer systems)
This section should be removed and replaced with the following information.
Initializing the hard disk
The BCM system is normally initialized prior to shipment. However, if you have to replace the
hard disk in a standard single-disk system, use this procedure to initialize the BCM software.
After initialization, you must restore the configuration data to the BCM. Use the backup and
restore utility (BRU) to restore configuration data. Nortel recommends that you maintain a current
configuration backup. If you do not have a current backup, enter the configuration data manually.
Perform the following procedures after you replace the hard disk and the system has booted up.
To initialize the hard disk in a single disk configuration
1 Ensure the Power (LED 1), Temp (LED 9), and Fan (LED 10) LEDs on the BCM main unit are
lit.
2 Connect to the BCM system.
3 Do one of the following:
Manually reenter configuration data.
Restore system and data information (except Telephony and Registry) from your backup data.
For information on how to restore data to your system from a backup, refer to the BCM 4.0
Administration Guide.
Page 196, Controlling and monitoring mirroring operations
This section should be replaced with the following information:
Note: When you replace a hard disk, IP configuration data is lost. The BCM system IP
address defaults to 10.10.10.1.
Note: Perform a backup only on similar software versions.
Chapter 2 Documentation updates for BCM 4.0 19
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
You can monitor and control disk mirroring through a control screen in Element Manager.
Under Administration > System Status > Disk mirroring, you can access a screen that allows
you to control the mirroring operation from your desktop, as well as display the status of the hard
disks. Refer to Table 1 for a list of the fields and a description of their function.
Table 1 Disk mirroring settings
Tab Field Functions Description
Settings Version Read-only field Shows the current version of mirroring firmware.
Operation Mode Primary Master Mirror mode is disabled. The Primary disk is the
operating disk.
Mirror Master Mirror mode is disabled. The Mirrored disk is now
the operating disk.
Mirror Mode The system is in Mirror mode.
Ultra UDMA Auto The interface speed to the hard disk is set
automatically. This is the default.
Mode The interface speed to the hard disk is set to a
specific timing.
Note: Changing the speed from auto could
significantly affect system performance.
Beep Timing Disable The failure tone is disabled.
Continuous The audible tone will beep continuously if a failure
occurs.
XX seconds/minutes
Default: BEEP_30Seconds.
The audible tone will beep for the period chosen if
a failure occurs.
Status DuplWin Dll version <current version number>
N/A
Shows the version or N/A if no version is found.
Primary Master Status Good, Bad, or N/A Indicates the current status of the primary hard
disk.
Mirror Master Status Good, Bad, or N/A Indicates the current status of the secondary hard
disk.
Initialization Status Started, Finished, Failed,
Shutdown, or N/A
Indicates current status of the initialization
process.
Configuration menu item Set Buzzer ON
Set Buzzer OFF
If turned on, you can control the module buzzer
remotely.
If turned off, the module buzzer can only be
controlled from the front of the controller.
Report menu item Status Screen Launches a new browser window that displays
mirroring summary. The summary shows which
hard disks are installed, where they are placed,
and which is the active hard disk.
Drive Status Displays a status bar to indicate process of
mirroring.
View Refresh Use this to update the status screen.
20 Chapter 2 Documentation updates for BCM 4.0
N0060603N0060603
Page 229, Determining the status of a telephone
The procedure, “To find out the status of a set,” should be modified as follows.
To find out the status of a set
1 Open Element Manager and connect to your BCM system.
2 From the Configuration tab, click the Telephony folder to expand it.
3 From the Telephony folder, select Sets.
4 From the Sets subfolder, select Active Sets.
5 In the Active Sets panel, select the desired telephone.
6 Use the various tabs and the Details panel to view the status of the telephone.
Page 230, Moving telephones
The sentence, “You can move a Business Communications Manager digital telephone to a new
location within the system without losing its programmed settings if the telephone has been
enabled with Set relocation in system programming under Feature programming,”
should be, “You can move a BCM digital telephone to a new location within the system without
losing its programmed settings if the system has been enabled with Set relocation (Configuration
> Telephony > Global Settings > Feature Settings).”
Page 233, Appendix A, Defining region-based defaults
This appendix should be removed and replaced with the chapter, “Market profile attributes” on
page 61.
Page 254, Set DNs and port numbers
In Table 64 on page 254, the references to PDD should be deleted.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Nortel Networks Water System BCM 1000 User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI