Barco iCon H500 User guide

Category
Projectors
Type
User guide

This manual is also suitable for

RS 232 Serial C ommunications for iCon
H250/400/500
Reference Guide
Basic
R59770077/01
23/07/2007
Product revision
Softw a re version : V 1.00
Barco nv Presentations
Noordlaan 5, 8520 Kuurne
Phone: +32 56.36.82.11
Fax: +32 56.35.86.51
Visit us at the web: www.barco.com
Printed in Belgium
Changes
Barco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied war-
ranties or m erchantability and tness for a particular purpose. Barco m ay make improvements and/or changes to the pr oduct(s) and/or the
program(s) desc ribed in this publication at any time without n otice.
This publication c ould c ontain technical inaccuracies or typographical errors. Changes are periodically made to the information in this
publication; these changes are incorporated in new editions of this publication.
Copyright ©
All rights reserved. No part of this documen t m ay be copied, reproduced or translated. It s hall not other
wise be recorded, transmitted or
stored in a retrieval system without the prior written consent of Barco.
EN55022/CISPR22 Class A ITE (Information Technology Equipment)
Class A ITE is a category o f all other ITE which satises the class A ITE limits b ut not the class B IT E limits. Such equipment should not
be restricted in its sale but the following warning shall be included in the ins tructions for u se:
Warning : This is a class A product. In a domestic environment this product may cause radio interference in which case the us er may be
required to take adequate measures.
Federal Communications Commis sion (FCC Statement)
This equipment h as been tested and found to comply with the limits for a class A digital device, pursuant to Par t 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a com m ercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in a ccordance with
the instruction manual, may c ause harmful interference to radio communications. Oper ation of this equipment in a residential area may
cause harmful interference, in which case the user will be responsible for correcting any interference at his own expense
Guaran tee and Compensation
Barco provides a guarantee relating to perfect manufacturing as pa
rt of the legally stipulated terms of guarantee. On receipt, the purchaser
must immediately inspect all delivered goods for damage incurred during transport, a s well as for material and manufacturing faults Barco
must be informed im mediately in writing of any complaints.
The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning,
at latest 30 days after the transfer of risks. In the event of justied notice of complaint, Barco can repair the fault or provide a replacement
at its own discretion within an appropriate period. If this measure proves to be impossible or uns uccessful, the purchaser ca n demand a
reduction in the purchase pr ice or cancellation of the c ontract. All other claims, in particular those relating to compensa tion for direct or
indirect damage, and also damage attributed to the operation of s oftware as well as to other services provided by Barco, being a component
of the system or independent service, will be deemed invalid provided the dam age is n ot pro ven to be attributed to the absence of properties
guaranteed in writing or due to the intent or gross negligence or part of Barco.
If the purchaser or a third party carries out m odications or repairs on goods delivered by Barco, or if the goods are ha ndled incorrectly,
in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goo ds are subject to inuenc es not
agreed upon in the contract, all guarantee claims of the purchaser will be r endered invalid. Not included in the guarantee coverage are
system failures which are a ttributed to programs or special electronic c ircuitry provided by the purchaser, e.g. interfaces. Normal wear as
well as normal maintenance are not subject to the guarantee provided by Barco either.
The environmental conditions as well as the servicing and maintenance regulations specied in the this m anual must be complied with by
the customer.
Trademarks
Brand and product name s mentioned in t
his manual may be trademarks, registered tradem arks or copyrights of their respective holders.
All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for
the products or their m anufacturers.
1. Serial communication basics
1. SERIAL COMMUNICATION BASICS
Overview
Serial c omm unication Protocol
Data words
Communication se ttings
Hardware
Serial comms comm ands
•Syntax
1.1 Serial communication Protocol
Communication protocol summary
Like every commun ication method the serial communication uses a particular protocol ( ANS I) which must be respected in orde r to
allow communication to take place, following table gives a sum mary of the predened comm unication terms.
Start byte \xfe
Projector address
Command b yte(s)
Data bytes
1
Checksum byte
Stop byte \xff
ANSI
American National standards Institute
Start byte
The “Start byte” informs the projector (in case of transmission) or the computer (in case of reception) that a new data transfer w ill
take place
Projector address
The “projector address” denes the ad dress o f th e computer the projector wants to talk to (in case of transmission) or the address
of the projector that answer s (in case of reception).
The maximu m number of p rojectors that can be addressed by one co mpu ter is 256.
Command byte(s)
There is at least on e command byte to dene the action to be performed. C omm ands that are not o ften used or c omplex commands
can take more than one byte. All command bytes that are sent b y the computer to get information out of the projector are repeated
in the an swer-data-transfer of the projector.
Data bytes (optional)
Whether the command bytes are followed by one or more data bytes depends on the co ntents of the command bytes.
Data which contains more than one byte is called a word and can also b e signed or unsigned.
Some commands do not require a data eld (s)
1. optional
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 1
1. Serial communication basics
Checksum byte
The “Checksum byte” is used to detect errors during transmission or r eception
Checksum byte = (projectoraddress + command bytes + Data bytes) Modulo \x100
Stop byte
The “Stop byte” informs the projector (in case of transmission) or the computer (in c ase of reception) that the data trans fer is c omplete
and that the interpretation of the c omm and and data by tes can start.
Acknowledge (ACK)
If the c omm unication link and if the sent commands can be interpreted by the projector an ACK com mand is sent back. In case the
commands cannot be interpreted a NACK command is se nt back.
End of process (EOP)
When the end of process command is activated, an EOP is send after the ACK command to signify the com pletion of the process.
for m ore information about this, see the EOP command.
Note
Any command byte, data byte or checksum byte that equals \x80, \xfe, \xff hastobeconverted!
1. Transm is sio n
- instead of \x80, send \x80 followed by \x00
- instead of \xfe, send \x80 followed by \x7e
- instead of \xff, send \x80 followed by \x7f
2. Reception
- replace \x80 followed by \x00 with \x80
- replace \x80 followed by \x7e with \xfe
- replace \x80 followed by \x7f with \xff
1.2 Data words
msb
The mos t signicant byte, is the byte with the greatest weight (value).
lsb
The less signicant byte, is the byte with t he smallest weight (value).
Description
A word contains more than one b yte, the rst byte is the msb, the last byte is t he lsb.
Examples of data words
The projector runtime parameter is described using an unsigned double w ord where 2 bytes (msb ...lsb) represent the value of
the runtime in seconds.
How to calculate the v alue of a w ord ?
Lets take the exam ple of a double word returned by the projector runtim e, read commando.
returned data = Data[0]....Data[3]
value = Data[0]*256
3
+ Data[1]*256
2
+ Data[2]*256 + Data[3].
2
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
1. Serial communication basics
1.3 Communication settings
Baud r ate
Denes the speed of the data transfer. The baud rate can be set using the menu structure.
Consult the Owner’s manual of the projector on how to change the baud rate setting.
Data Bits
Eight data bits are used for each character of the data transfer.
Parity
There is n o parity bit used to perform error c hecking.
Stop Bits
One stop b it is used to dene the end of a character.
1.4 Hardware
Overview
Female D9–pin connector labelled “RS232 IN” used to connect the pr ojector with the com puter.
Pin ou t of the D9 connector:
Pin Name Full Name
1
CD Carrier Detect
2 RxD Rece ived Data
3 TxD Transmitted Data
4 DTR Data Terminal R eady
5
GND Signal G round
6
DSR Data Set Ready
7
RTS Request To Send
8
CTS Clear To Send
9 RI Ring Indicator
Standard serial Cable
- order number R9827560 (cable length = 15m )
- order number R9827570 (cable length = 30m )
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
3
1. Serial communication basics
1
CD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
1
CD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
D9
female
D9
male
Image 1-1
connection: IBM PC or compatible projector
1
HSKo
2
HSKi
3
TxD-
4
GND
5
RXD-
6
TXD+
7
n.c.
8
RXD+
4
DTR
8
CTS
3
TxD
5
GND
2
RxD
DIN
mini 8
D9
male
Image 1-2
connection: MAC projector
Signal levels
Following table gives the signal levels co rresponding to the different s tates:
State Voltage
Off = 1 -9V
On = 0 +9V
4 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
1. Serial communication basics
1.5 Serial comms commands
Basic Commands
Basic commands are the c omm ands used to c ontrol the basic parameters of the projector.
The Contrast increment command is a basic c omm and.
Advanced Commands
Advanced c omm ands are used to control advanced parameters of the pro jector.
The Piploopfocusis an advanced parameter
This manual is divided in two parts, the rst part contains the basic (elementary) co mm and s w h ile the se cond
part gives an overview of the a vailable adv anced comman ds.
Some comm ands are illustrated w ith an example.
1.6 Syntax
Characters
In this manual, all characters are expressed using the C- language syntax:
decimal values ddd
2
hexadecimal values \xhh
3
The characters that can be used are
For text elds: "AB CDEFG HIJKLMNO PQR STUVW X YZ012345678 9+-/&@#_:;abcdefghijklmnopqrstuvwxyz”
For lenames: "?*ABCDEFGHIJKL MNOP QR STUVW XYZ abcdefghijklmnopqrstuvwxyz0123456789_ -"
Negative values /numbers
The 2s complemen t number sy stem is u sed to express negative num bers
Pascal- language string
A Pascal-language s tring consists of one or more characters. T he rst character of the string co ntains the length of the string.
Therefore, a Pascal-language string is limited to 255 characters.
Pascal string ’Hello world”
length
\x0b
’h’
\x68
’e’
\x65
’l’
\x6c
’l’
\x6c
’o’
\x6f
\x20
’w’
\x77
’o’
\x6f
’r
\x72
’l’
\x6c
’d’
\x64
C-language string
A C-language string consists of one or mo
re characters. The last character of the string is a lways the NULL character \x00. There-
fore, the length of a C-language s tring is de termined by the position of the NULL character.
2. ddd=0...255
3. hh=00...ff
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 5
1. Serial communication basics
Cstring’Helloworld
’h’
\x68
’e’
\x65
’l’
\x6c
’l’
\x6c
’o’
\x6f
\x20
’w’
\x77
’o’
\x6f
’r
\x72
’l’
\x6c
’d’
\x64
NULL
\x00
Image les
The image les are described as ASCII text in XML format i.e. a header and the different elements and their value placed between
tags :
<?xml version="1.0" encoding="UTF-8" ?>
<ImageFile>
<FileSelection>
<InputLayer />
<SourceType />
<LineDuration Discrepancy="427" Unit="ns">20677</LineDuration>
<TotalLines Discrepancy="0">806</TotalLines>
<Interlaced>no</Interlaced>
</FileSelection>
<ImageDefinition>
<TotalPixels>1344</TotalPixels>
<ActivePixels>1024</ActivePixels>
<PixelStart>135</PixelStart>
<ActiveLines>768</ActiveLines>
<LineStart>29</LineStart>
<AspectRatio>4:3</AspectRatio>
</ImageDefinition>
</ImageFile>
Since the XML le is parsed internally in the pr ojector it will return a NACK if the data is not valid (does not respect the XML com-
pleteness rules).
Desktop error strings
The operating s ystem (Windows
TM
) uses a yellow notication arrea to display errors and messages. These mes sages appear in the
lower right corner o f the desktop.
The acknowledge bytes are followed by a character string r epresenting the actual messag e or error displayed.
An example is the error “No image le found” that can be generated when selecting a inactive (not present) source.
The character string sent is the following :
\x2b\x00\xff\xff\xff\xf1\x00\x4e\x00\x6f\x00\x20\x00\x49\x00\x6d\x00\x61\x00\x67\x00\x65\x00\x66\x00\x69\x0
0
Note that each character is followed by the \x00, the string being als o ended with \x00.
6 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
2. Basic commands
2. BASIC COMMANDS
Overview
Identication c omm ands
RCU command s
•ProjectorON/OFF,Write
Projector’s Status, Read
Lens Commands
Picture setting
•MenuExit
Background, Write
Background, Read
Source selection
Scan inputs
Scanned inputs, read
Orientation, Write
Orientation, Read
Freeze, Write
Freeze, Read
Aspect ratio, Write
Aspect Ratio, Read
Lamp comm ands
Image les c omm ands
Standby Timer, Write
Standby Timer, Read
Filmmode detection, Increment/Decrement
Filmmode detection, Write
Filmmode detection, Read
2.1 Identication commands
2.1.1 Device type, Read
Description
Reads the device (projector) type, the returned string is a Pascal-language string.
Command
Command [0]
\x6b
Returned Data
Data[0] = byLength = 1 byte describing the length of the string.
Data[1] = s trDeviceType = pascal-language string describing the device type.
An example of device type is “IQ”
2.1.2 Projector ’s Software version, Read
Description
Reads the P rojector ’s S oftware version, the returned string is a Pas cal-language s tring.
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
7
2. Basic commands
Command
Command [0]
\x60
Returned Data
Data[0] = by Length = 1 byte describing the length of the software version string.
Data[1] = strSoftwareVersion
2.1.3 Projector ’s Serial number, Read
Description
Reads the P rojector’s serial number, the r eturned string is a Pascal-language string.
Command
Command [0]
\x61
Returned Data
Data[0] = \x07 = length of the serial number = 7 c haracters
Data[1] = string of length 7
2.1.4 Projector’s runtime, Read
Description
Reads the Projector’s runtime in seconds
Command
Command [0]
\x62
Returned Data
unsigned double word (4 bytes).
Data[0] = msb
Data[1]
Data[2]
Data[3] = lsb
2.1.5 Projector address, Write
Description
Writes a new addr ess to the projector
Command
Command [0]
\x6D
Data
Data[0] = unsigned byte
Example
Writes a new address to the projector, being “1”
Transmit
Start
\xfe
Projector address
\x01
Command[0] \x6d
Data[0]
\x01
8 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
2. Basic commands
Transmit
Che cksum
\x6f
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
2.1.6 Projector la nguage, Read
Description
Reads the active language for the projector
Command
Command [0]
\x71
Returned Data
Data[0] = unsigned byte
byte value language
0 English
1 Français
2 Deutsch
3 Español
4 Japanese
5
Chinese
Example
reads the ac tive language, being “Français”
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x71
Che cksum
\x72
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
Receive (answer)
Start
\xfe
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 9
2. Basic commands
Receive (answer)
Projector address
\x01
Command[0]
\x71
Data[0]
\x01
Che cksum
\x73
Stop
\xff
2.1.7 Projector language, Write
Description
Sets a new language for the projector
Command
Command [0]
\x70
Data
Data[0] = unsigned byte
byte value language
0 English
1 Français
2 Deutsch
3 Español
4 Japanese
5
Chinese
Example
Sets the language to “Français”
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x70
Data[0]
\x01
Che cksum
\x72
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
2.1.8 Baudrate, Write
Description
Sets the baudrate
10
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
2. Basic commands
Command
Command [0]
\x75
Data
string = C-language string
possible string values
9600
19200
38400
57600
115200
2.2 RCU commands
Description
Simulation of the RCU c odes sent by the RCU remote control.
"RCU command s", page 67
Command
Command [0]
\x30
Data
Data[0] = byIRcode = 1 byte representing the RC5 co de of the function to be executed.
Wrepeat (optional) = word (2 bytes) representing the dur ation.
2.3 Projector ON/OFF, Write
Description
Switching ON/OFF the projector
Command
Switching the projector ON
Command [0]
\x65
Switching the projector OFF
Command [0]
\x66
Example
Switches the projector ON
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x65
Che cksum
\x66
Stop
\xff
Receive (acknowledge)
Start
\xfe
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 11
2. Basic commands
Receive (acknowledge)
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
2.4 Projectors Status, Read
Description
Reads the Projector’s Status
Command
Command [0]
\x67
Returned Data
Data [0] = unsigned by te
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
Not used Not used Cool down cycle
active = 0
inactive = 1
Not used Not used Not used Textbox
ON = 1
OFF = 0
Projector
ON = 1
OFF = 0
bit5 gives an indication on whether the projector ca n be (re)started or not (ho t restrike), if the cool down cycle
is active (bit5 = 0) the projector can not be restarted until the cool down cycle has been completed.
Example
Read the status being : \x23:
projector is ON
textbox is on
cool down cy cle is inactive
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x67
Che cksum
\x68
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
Receive (Awnser)
Start
\xfe
12 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
2. Basic commands
Receive (Awnser)
Projector address
\x01
Command[0]
\x67
Data[0]
\x23
Che cksum
\x8b
Stop
\xff
2.5 Lens Commands
2.5.1 Lens Zoom
Description
To Zoom the image in or out depending on the data sent.
Command
Command [0]
\xf4
Command [1]
\x82
Data
Data[0] = byDirection = 1 byte, gives the Zoom direction (in/out):
0 = out ; 1 = in
2.5.2 Lens Focus
Description
To Focus the image.
Command
Command [0]
\xf4
Command [1]
\x83
Data
Data[0]=byDirection=1byte: 0=“-”;1=“+
2.5.3 Lens vertical shift
Description
Shifts the lens down or up depen ding on the data sent.
Command
Command [0]
\xf4
Command [1]
\x81
Data
Data[0] = byDirection = 1 byte, give s the shif
t direction:
0 = down ; 1 = up
2.5.4 Lens horizontal shift
Description
Shifts the lens left or right depending on the data sent.
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 13
2. Basic commands
Command
Command [0]
\xf4
Command [1]
\x80
Data
Data[0] = byDirection = 1 byte, give s the shift direction:
0 = Left ; 1 = Right
2.6 P icture setting
Overview
Contrast, Increment
Contrast, decrement
Cont ra st , writ e
Contrast, Read
Minimum C ontrast, Read
Maximum Contrast, Read
Brightness, increment
Brightness decrement
Brightness, Write
Brightness, Read
Minimum B rightness, Read
Maximum Brightness, Read
Saturation increment
Saturation, decrement
Write Sat u ra ti on
Saturation, Read
Minimum S aturation, Read
Maximum Saturation, Read
Tint, increment
Tint, decrement
Tint, Write
Tint, Read
Minimum Tint, Re ad
Maximum Tint, Read
Gamma, increment
Gamma, decrement
Gamma, Write
Gamma, Read
Minimum Gamma, Read
Maximum G amm a, Read
Phase, increment
Phase, decrement
•Phase,Write
Phase, R ead
Minimum Phase, Re ad
Maximum P hase, Read
2.6.1 Contrast, Increment
Description
Increments the contrast by one.
14
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
2. Basic commands
Command
Command [0]
\x22
Command [1]
\x01
Example
Increment con trast of a projector with address \x01 by one .
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x22
Command[1]
\x01
Che cksum
\x24
Stop
\xff
2.6.2 Contrast, decrement
Description
Decrements the contrast by one.
Command
Command [0]
\x23
Command [1]
\x01
2.6.3 Contrast, write
Description
Writes a new contrast value to the projector
Command
Command [0]
\x20
Command [1]
\x01
Data
Data [0] = contrast value
Data[0] = unsigned byte
Example
Writes a new contrast value of \x20 to the projector
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x20
Command[1]
\x01
Data
\x20
Che cksum
\x42
Stop
\xff
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007 15
2. Basic commands
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
2.6.4 Contrast, Read
Description
Reads the actual contrast value of the projector
Command
Command [0]
\x21
Command [1]
\x01
Returned Data
Data [0] = contrast value
Example
Reads the actual contrast v alue of the projector, the aw nser being \x20
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x01
Che cksum
\x23
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Che cksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x01
Data [0]
\x20
Che cksum
\x43
Stop
\xff
16 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400/500 23/07/2007
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75

Barco iCon H500 User guide

Category
Projectors
Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI