Unical FIREX 2S Installation guide

Type
Installation guide
INSTALLATION AND MAINTENANCE INSTRUCTIONS
FIREX 2S
34 - 45 - 55
-
1 GENERAL INFORMATION .................................................................................................................................................................................4
1.1 General warnings .......................................................................................................................................................................................... 4
1.2 Symbols used in the manual ......................................................................................................................................................................... 5
1.3 Appropriate use of appliance ........................................................................................................................................................................ 5
1.4 Information for the user ................................................................................................................................................................................. 5
1.5 Safety warnings ............................................................................................................................................................................................. 6
1.6 Technical data plate ......................................................................................................................................................................................7
General informationTechnical FeaturesInstallation instructionsMaintenance instructions
4 INSPECTION AND MAINTENANCE ................................................................................................................................................................52
Inspection and maintenance instructions ...........................................................................................................................................................52
Boiler body maintenance ................................................................................................................................................................................... 53
Cleaning and routine maintenance ..................................................................................................................................................................... 53
Maintenance operations .....................................................................................................................................................................................53
3 INSTRUCTIONS FOR THE INSTALLER ................................. 18
3.1 General warnings ............................................................. 18
3.2 Installation standards ....................................................... 18
3.3 Installationonoldorretrottablesystems ........................ 18
3.4 Packaging ........................................................................ 19
3.5 Transportation .................................................................. 19
3.6 Installation ....................................................................... 20
3.7 Connecting boiler to system .............................................21
3.8 Hydraulic connections .....................................................21
3.9 Chimney connection ........................................................26
3.10 Electrical connections ...................................................... 29
3.11 Connections .................................................................... 30
3.12 Hydraulic base diagrams .................................................31
3.13 Panel board ..................................................................... 38
3.14 Filling the system .............................................................44
3.15 Boiler start-up ................................................................... 45
3.16 Summer mode ................................................................. 48
3.17 Warnings.......................................................................... 48
2 TECHNICAL FEATURES AND DIMENSIONS ...................................................................................................................................................8
2.1 Technical features ......................................................................................................................................................................................... 8
2.2 Dimensions and hydraulic connections ......................................................................................................................................................... 9
2.3 Technical data ............................................................................................................................................................................................. 10
2.4 Main components ....................................................................................................................................................................................... 14
2.5 General Information .................................................................................................................................................................................... 14
2.6 Features of the wood ...................................................................................................................................................................................17
3.18 Eliminating faults .............................................................. 49
3.19 Alarm diagram and troubleshooting ................................. 50
3.20 Audible alarms ................................................................. 51
1.2 - SYMBOLS USED IN THE MANUAL

1.3 - APPROPRIATE USE OF THE APPLIANCE
The
technical safety rules.

damage to the appliance or other property.
The appliance is designed to operate in hot water circulation heating systems.
Any other use must be considered improper.
UNICAL will not be held liable for any damage resulting from improper use.
Use according to the intended purposes also includes strict compliance with the instructions in this manual.
The user must be instructed on use and operation of the heating system, in particular:
• Delivertheseinstructionstotheuser,aswellasotherdocumentsconcerningtheapplianceinsertedintheenvelope
inside the packaging. .
• Informtheuserabouttheimportanceoftheairventsandtheuegasexhaustsystem,highlightingtheiressential
features and the absolute prohibition of modifying them.
• Informtheuseronhowtocontrolthesystem'swaterpressureaswellasoperationstorestoreit.
• Informtheuseroncorrecttemperaturecontrol,controlunits/thermostatsandradiatorsforsavingenergy.
• Rememberthatthesystemmustreceiveregularmaintenanceatleastonceayearandacombustionanalysismust
be performed every two years (as per national law).
• Shouldtheappliancebesoldortransferredtoanewownerorifyoumoveandleavetheappliance,alwaysmake
sure that the instruction manual accompanies the appliance so that it can be consulted by the new owner and/or
installer.

failure to comply with the instructions contained in this manual.

NOTE!
Tips
for the user
ATTENTION!
Possible dangerous
situation for the product
and the environment
DANGER!
Serious danger for
personal safety and life

ATTENTION!
-

animals and property for which the manufacturer will not be held liable.
DANGER!

recommend stipulating a maintenance contract.
-

Modifying parts connected to the appliance
Do not modify the following parts:
- the boiler
- the air, water and electrical current lines
- theuegaspipe,thesafetyvalveandtheexhaustpipe
- theconstructionpartswhichaecttheoperatingsafetyoftheappliance
Attention!
Useonlyappropriatexedspannerstotightenorloosenthescrewedttings.
Incompliant use and/or inappropriate tools can cause damage (e.g. water or gas leakage).

Donotuseorstoreexplosiveoreasilyammablematerials(e.g.petrol,paints,paper)intheroomwheretheappli-
ance is installed.
ATTENTION!


operations. Children must be supervised so that they do not play with the appliance.

The technical data plate is adhesive and is included in the
document case; it must be applied by the installer on the
outside of the casing.
The serial number of the boiler is on the riveted plaque on
the front plate of the body (front right bottom side).
Key
Destination country
2
TECHNICAL FEATURES
AND DIMENSIONS
2.1 - TECHNICAL FEATURES
The heat generator mod. FIREX 2S is a steel boiler running with
naturalwoodenlogs,totalgasication,ameinverted,withthe
combustion chamber under negative pressure.
It is supplied in the following models:
FIREX 2S 34
FIREX 2S 45
FIREX 2S 55
DESCRIPTION OF COMPONENTS:
• Steelboilerbodywithcombustionchamberpartiallycovered
with refractory material
• Burnerinrefractorymaterial
• Horizontalsmokeducts
• Frontdoorforloadingwoodcoveredwithrefractorymaterial
• Bottomdoorcoveredwithrefractorymaterial,completewith
combustionairadjustmentsandttedwithamesightglass
• Rearsmokechamberwithsideinspectionandashremoval
doors
• Fluegasextractionwithintakemodulatingfan
• Safetyheatexchanger
• Boilerbodyinsulatedwith50mmthickmineralwoolpanels
• Powderpaintedsheetsteelcasing
PANEL BOARD COMPONENTS:
• Mainswitchwithlightindicatingpresenceofvoltage
• Safetythermostatforboileroverheating
• Generalfuse
• Display
2.2 - HYDRAULIC DIMENSIONS AND CONNECTIONS
1. Panel board
2. Primary air adjustment
3. Secondary air adjustment
4. Flame sight glass
5. Cleaning doors
6. Rear smoke chamber
7. Loading door
8. Modulating fan
9. Bottom inspection and cleaning door
DIMENSIONS
A
B
C
D
E
F
G
510
680
610
680
610
880
1230 1380
190
81
190
78
1025
628
1380
190
81
11501150
628 828
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
CONNECTIONS
T1 - T2
T5
T6
T3 - T4 - T7 - T8
UNI ISO 228/1
(Ø mm)
UNI ISO 228/1
G 1¼
150
G ½
G ½
G 1½
200
G ½
G ½
UNI ISO 228/1
H
65 65
(mm)
G 1½
200
G ½
G ½
65
FIREX 2S 34 FIREX 2S 45 FIREX 2S 55
T1. Centralheatingow
T2. Central heating return
T3. Safetythermostatprobebulbholder,boilerowprobe
T4. Connection for any temperature relief valve probe bulb
holder
T5. Chimney connection
T6. Safety heat exchanger connections
T7. Boiler drain
T8. Return probe connection
T7T8
FIREX 2S 34 FIREX 2S 45 FIREX 2S 55MODELS
MAXIMUM NOMINAL OUTPUT*
(kW)
30.6 40.1 49.10
FURNACE MAXIMUM OUTPUT
(kW)
34.2 45.0 55.16
* Powerachievedwithgoodqualitywoodcontaining15%humidity.
** Consideringathermalpowerrequirementof34kcal/m
3
WATER SIDE PRESSURE DROPS (10K)
WATER SIDE PRESSURE DROPS (20K)
BOILER WATER CONTENT
EMPTY BOILER WEIGHT
MAXIMUM OUTPUT
OUTPUT IN STAND-BY
BOILER CLASS ACCORDING TO EN 303-5 (2012)
(m.w.c. - Pa)
0.2 - 1961 0.4 - 3922 0.5 - 4903
0.07 - 4860.07 - 4860.05 - 490
(m.w.c. - Pa)
(l)
(kg)
(W)
(W)
59
363
146
5
71
475
146
5
93
623
146
5
5 5 5
DURATION OF COMBUSTION
WOOD STORAGE VOLUME
MAX OPERATING PRESSURE
LOADING OPENING
LOG LENGTH
(h)
5 6 6
218160108
(l)
(bar)
(mm)
(cm)
3
334 x 419
50
3
434 x 519
50
3
434 x 519
70
NOISE LEVEL
(dB)
<50 <50
<50
MINIMUM DRAUGHT REQUIRED BY CHIMNEY
(Pa)
20 20 20
MIN. FLOW TEMPERATURE
(°C)
70 70 70
MAX. FLOW TEMPERATURE
(°C)
85 85 85
MIN. RETURN TEMPERATURE
(°C)
55 55 55
NOMINAL LOADING FLUE GAS TEMPERATURE
(°C)
171 177
178
NOMINAL LOADING FLUE GAS MASS FLOW RATE
(kg/s)
0.02 0.026
0.032
EFFICIENCY
(%)
89.5 89.1 89.1
O2
(%)
4.73 5.10 6.10
CO2
(%)
13.9 13.74 13.6
2.3 - TECHNICAL DATA
CO 10%
(mg/Nm
3
)
361 469 367
CO 13%
(mg/Nm
3
)
262 341 267
NOx 10%
(mg/Nm
3
)
180 183 189
NOx 13%
(mg/Nm
3
)
131 133 137
Hc 10%
(mg/Nm
3
)
1.1 10 11
Hc 13%
(mg/Nm
3
)
0.8 7.3 8
Dust 10%
(mg/Nm
3
)
27 25 27
Dust 13%
(mg/Nm
3
)
19 18 19
FUEL CHARACTERISTICS
See par. 2.7
THERMAL STORAGE VOLUME (Recommended)
(If Qmin > 30% of Qn)
(l)
1256 1682 2089
MAX. FEED WATER TEMPERATURE
SAFETY HEAT EXCHANGER
(°C)
15 15 15
FEED WATER PRESSURE
SAFETY HEAT EXCHANGER
(bar)
1.5 1.5 1.5
BOILER OPERATION
WITH FAN
COMBUSTION CHAMBER OPERATION
UNDER NEGATIVE PRESSURE
OPERATION IN CONDENSATION
NO
MAXIMUM HEATABLE VOLUME **
(m
3
)
876 1149 1408
2.3.1 - TECHNICAL DATA ACCORDING TO ErP DIRECTIVE
FIREX 2S 34
Fuel Preferred fuel
(only one):
Others
suitable fuels:
Seasonal emissions
mg / m³ 10%
PM OGC CO NOX
Logs moisture content ≤ 25 % X 27 1.1 361 180
Chips, moisture content 15-35 %
Chips, moisture content > 35 %
Compressed wood in the form of
pellets or briquettes
Sawdust, moisture content ≤ 50 %
Other wood biomass
Non-wood biomass
Bituminous coal
Lignite (including briquettes)
Coke
Anthracite
Briquettes of fossil fuel mixture
Other fossil fuels
Briquettes of biomass mixture (30-70 %)
and fossil fuels
Other mixtures of biomass and fossil fuels
Commission Delegated Regulation (EU) 2015/1187 of 27 April 2015 supplementing Directive 2010/30/EU with regard to the
energy labelling of solid fuel boilers and packages of a solid fuel boiler, supplementary heaters, temperature controls and solar
devices (1).
Operating characteristics with preferred fuel:
Seasonal energy eciency of central heating ηs [%]:
79
Energy eciency index EEI:
117
Entry Symbol Value U.M. Entry Symbol Value U.M.
Eective heat Output Useful Eciency
At nominal
heat output
P
n
30.62 kW
At nominal heat
output
η
n
83.4 %
At [30 %/50 %] of
nominal heat output, if
pertinent
P
p
n.p kW
At [30 %/50 %] of
nominal heat output,
if pertinent
η
p
n.p %
For solid fuel cogeneration boilers:
Electrical eciency
Auxiliary electricity consumption
At nominal heat
output
el
max
0.146 kW
At nominal heat output η
el,n
n.p %
At [30 %/50 %] of
nominal heat output,
if pertinent
el
min
0.000 kW
If required, integrated equipment
for the abatement of secondary
emissions
n.p. kW
Standby mode P
SB
0.005 kW
FIREX 2S 34
Manual loading type
Manual loading puer volume l. 1256 Automatic loading puer volume l. 612
Non-condensation boiler type
Cogeneration NO
Combined boiler NO
FIREX 2S 45
Fuel Preferred fuel
(only one):
Others
suitable fuels:
Seasonal emissions
mg / m³ 10%
PM OGC CO NOX
Logs moisture content ≤ 25 % X 25 10 469 183
Chips, moisture content 15-35 %
Chips, moisture content > 35 %
Compressed wood in the form of
pellets or briquettes
Sawdust, moisture content ≤ 50 %
Other wood biomass
Non-wood biomass
Bituminous coal
Lignite (including briquettes)
Coke
Anthracite
Briquettes of fossil fuel mixture
Other fossil fuels
Briquettes of biomass mixture (30-70 %)
and fossil fuels
Other mixtures of biomass and fossil fuels
Entry Symbol Value U.M. Entry Symbol Value U.M.
Eective heat Output Useful Eciency
At nominal
heat output
P
n
40.1 kW
At nominal heat
output
η
n
82.9 %
At [30 %/50 %] of
nominal heat output, if
pertinent
P
p
n.p kW
At [30 %/50 %] of
nominal heat output,
if pertinent
η
p
n.p %
For solid fuel cogeneration boilers:
Electrical eciency
Auxiliary electricity consumption
At nominal heat
output
el
max
0.146 kW
At nominal heat output η
el,n
n.p %
At [30 %/50 %] of
nominal heat output,
if pertinent
el
min
0.000 kW
If required, integrated equipment
for the abatement of secondary
emissions
n.p. kW
Standby mode P
SB
0.005 kW
FIREX 2S 45
Manual loading type
Manual loading puer volume l. 1682 Automatic loading puer volume l. 802
Non-condensation boiler type
Cogeneration NO
Combined boiler NO
Operating characteristics with preferred fuel:
Seasonal energy eciency of central heating ηs [%]:
79
Energy eciency index EEI:
116
FIREX 2S 45
Fuel Preferred fuel
(only one):
Others
suitable fuels:
Seasonal emissions
mg / m³ 10%
PM OGC CO NOX
Logs moisture content ≤ 25 % X 27 11 367 189
Chips, moisture content 15-35 %
Chips, moisture content > 35 %
Compressed wood in the form of
pellets or briquettes
Sawdust, moisture content ≤ 50 %
Other wood biomass
Non-wood biomass
Bituminous coal
Lignite (including briquettes)
Coke
Anthracite
Briquettes of fossil fuel mixture
Other fossil fuels
Briquettes of biomass mixture (30-70 %)
and fossil fuels
Other mixtures of biomass and fossil fuels
Entry Symbol Value U.M. Entry Symbol Value U.M.
Eective heat Output Useful Eciency
At nominal
heat output
P
n
49.1 kW
At nominal heat
output
η
n
82.9 %
At [30 %/50 %] of
nominal heat output, if
pertinent
P
p
n.p kW
At [30 %/50 %] of
nominal heat output,
if pertinent
η
p
n.p %
For solid fuel cogeneration boilers:
Electrical eciency
Auxiliary electricity consumption
At nominal heat
output
el
max
0.146 kW
At nominal heat output η
el,n
n.p %
At [30 %/50 %] of
nominal heat output,
if pertinent
el
min
0.000 kW
If required, integrated equipment
for the abatement of secondary
emissions
n.p. kW
Standby mode P
SB
0.005 kW
FIREX 2S 55
Manual loading type
Manual loading puer volume l. 2089 Automatic loading puer volume l. 982
Non-condensation boiler type
Cogeneration NO
Combined boiler NO
Operating characteristics with preferred fuel:
Seasonal energy eciency of central heating ηs [%]:
79
Energy eciency index EEI:
116
2.4 - MAIN COMPONENTS
2.5 - GENERAL INFORMATION
1. Panel board
2. Top cover
3. 2 side panels
4. Anti-smoke door
5. Woodstoragedoorwithrefractorymaterialandgasket
6. Primary and secondary air adjustment unit
7. Fan
8. Combustionchamberdoorwith
refractorymaterial,gasket,amesightglass
9. Steel combustion chamber
10.Heatexchangen
11. Boiler drain
12. Safety heat exchanger
13.Boilerbodyinsulationinmineralwool
14. Steel boiler body
15.Burnerbuiltwithrefractorymaterialwithbarsandgrate
16. Smoke chamber
17. By pass
M Heatingsystemow
R Heating system return
N.B.:Therebarsandtherefractorysteelgratearesubjecttowear;itisthereforead-
visable to carry out an annual inspection to prevent faulty boiler operation.

FLAME COMBUSTION
Everybody knows that to make a match last it must be held with
its head upwards. This is because in its convective motion, the
amemustnotmeetfuelotherthanthatwhichhasgeneratedit.
As in residential heating the fuel is usually in the form of wood
logswhichareloadedfromthetop,theamehastogointhe
opposite direction, i.e. downwards.
Natural draught is a source of negative pressure which varies
greatly depending on the type of chimney, on weather conditions,
on the type of fuel, etc.
Therefore, it is necessary to integrate it with a forced ventilation
unittostabiliseitseects.
Byttingafan,itispossibletoconsiderablyreducethesectionof
the gas ducts on the grate and, furthermore, there are no problems
with cold chimney starts.
The small grate permits more controlled passage of combustion
air, contrarily to what happens with large traditional grates.
The air can be perfectly adjusted because the grate, covered
with burning wood, has the same crossing resistance and thus
combustion will always be optimal.
FIREX 2S BOILER STRUCTURE
The boiler body is composed of two oval elements placed one
inside the other so that a water cavity is created between the two.
The large capacity wood storage has a special thermal and
mechanical high resistance refractory press, for the purpose of
keeping the bypass area dry in all operating conditions.
The following parts can be distinguished:
1. Wood storage, drying zone
2. Gasicationzone
3. Embers zone
4. Burner in refractory material
5. Combustion chamber
6. Heat exchange surface
7. Cradle in refractory material
8. Boilerwater
9. Safety heat exchanger
M Systemhotwaterow
R System return
GASIFICATION ZONE (2)
Gasicationtakesplace in the lowerpart of the woodstorage
compartment.
Itisveryimportantforgasicationtobeasregularaspossible,
so as not to overload the burner with gas.
Gasicationspeeddependsontheamountoffuelandthesize
of the drying area. Generally, it is better to use large logs if they
are dry and small logs if the wood is moist. The quantity of pri-
mary air, proportional to the delivered output, is regulated via the
adjustment system.
EXCHANGE SURFACE (6)
Operating on wood and without very high sulphur percentages,
itisimportanttoachieveverylowuetemperaturestoimprove
watereciency.Accordingly,adry-passageexchangesurface
wasadopted,whichisalreadywelltestedfordiesel-redboilers
operatingwith lowtemperaturewater, providinglowue gas
temperatures without the risk of condensation.
The surfaces of the dry ducts "A" feature cuts, to avoid dilation
issues.
The solid combustion residues (ashes), laid on the high tem-
perature refractory cradle will become, over time, increasingly
lighter until they are carried by the gas speed and deposited in
the lowest area of the rear smoke chamber, from which they will
be removed during cleaning.

Wood is formed mainly by cellulose and lignite. It
alsocontainsothersubstances,suchasresin(r-
pine), tannin (oak - chestnut) and, obviously, a large
quantity of water.
Good quality woods are oak, ash, beech, maple
andfruittrees,exceptcherry;mediumqualitywood
is:chestnutandbirch;sucientqualitywood:lime
tree, poplar and willow. Resinous trees are, normally,
second-rate quality fuels.
Wood is therefore an extremely heterogeneous
fuel, due to dierent essences (beech, oak, fruit,
resinous),dierent moisture content, and due to
dierentshapesanddimensions.
Boiler operation will inevitablybe eected by all
these factors. Especially by the log dimensions, the
moisture content and the way wood is loaded in the
boiler.

The caloric value of the dierent types of wood
depends on their moisture content, as illustrated in
the table. Boiler output and autonomy will diminish as
the moisture increases. The table provides the power
reduction factor based on the moisture of the wood
being used. The heat output of the FIREX 2S boiler
is calculated for wood with a 17% moisture content.
As an example, wood which has been dried for
2 years in a sheltered area has a 25% moisture
content.
Example:
moisture of the wood being used = 25%
output = nominal output x 0.86
Correction factors for wood moisture
% OF
HUMIDITY
CALORIFIC
VALUE
kWh/kg
CORRECTION
FACTOR
15
20
25
4.50
4.18
3.87
1
0.93
0.86
DIMENSIONS
The dimensions, together with the moisture content,
contribute to determine the boiler’s output. Small
pieces (with a length, however, conforming to indi-
cationsindicatedhereby)aremoreeasilyammable
and therefore have the tendency to increase the
boiler’s output and therefore to reduce its auton-
omy. Moreover, they fall with greater facility, in the
lower chamber, reducing the risk of the formation of
“bridges”. The so-called “bridge” is an empty space
in the wood storage compartment, where unburnt
wood logs remain. In this case, the bed of embers
is not fed with continuity and the refractory burner’s
slot is uncovered. In these conditions, preferential
airductsarecreatedwithaverysmallamedueto
an excess of air.
CALORIFIC
VALUE
MJ/kg
16.20
15.05
13.93
3
INSTRUCTIONS FOR
INSTALLATION

ATTENTION!
This boiler is intended solely for the use it
was expressly designed for. Any other use
is to be considered improper and therefore
dangerous.
This boiler heats water at a temperature
lower than the atmospheric pressure boiling
temperature.
ATTENTION!
The appliances are designed to be installed
inside suitable rooms or technical spaces
only. The appliances cannot be installed or
operate outdoors. Outdoor installation can
cause malfunctioning and be dangerous.

outdoor installation.
Before connecting the boiler, have professionally
qualiedpersonnel:
a) Thoroughly wash all the piping of the system to
remove any residue or impurities which could
jeopardiseproperoperationoftheboiler;
 b) Checkthatthechimney/uehasan
appropriate draught, without any bottlenecks,
and that no exhausts from other appliances are
inserted,unlesstheuehasbeenimplement-
ed to accommodate several utilities according
to specific standards and prescriptions in
force.Onlyafterthischeckcanthettingbe-
tweentheboilerandchimney/uebemounted;
ATTENTION!
The appliance must be installed by a qual-
    -
sional requirements according to Italian
     
 
with the standards according to good prac-
tice rules.
The boiler must be connected to a central heating
system and/or domestic hot water production
networkcompatiblewithitseciencyandoutput.
3.2 - INSTALLATION STANDARDS
Itmustbeinstalledbyaprofessionallyqualiedtechnician,who


applicable technical standards.
3.3 - INSTALLATION ON
OLD OR RETROFITTABLE SYSTEMS
Before installing this appliance on old systems, check that:
- The chimney is able to withstand the temperature generated
by the combustion products, has been measured and de-
signed according to the regulations in force, is airtight and
insulated, and does not have any obstructions or constrictions.
- The chimney has a connection for draining condensation.
- Theelectricalsystemhasbeensetupbyaqualiedtechnician
in compliance with the rules in force.
- Therate,head and directionof the owof the circulation
pumps are appropriate.
- The expansion vessel(s) can fully absorb any dilation of the
uidinthesystem.
- Theexpansionvesselscanfullyabsorbdilationoftheuidin
the system.
- The system has been cleaned and cleared of all sludge
and scale, has been vented, and all of its seals have been
checked.
- There is a treatment system for feed/recirculation water.
3.4 - PACKAGING
FIREX 2S boilers are delivered unassembled: the casing, fan,
panel board, handles and cleaning accessories are all shipped
in separate boxes.
After having removed all packaging, make sure that
the supply is complete and undamaged.
If in doubt, do not use the appliance and contact
the supplier.
Keep the packaging material (cardboard boxes,
straps, plastic bags, etc.) out of the reach of
children as they are potential sources of
danger.
Unical will not be held liable for damage to per-
sons, animals or objects due to failure to comply
with the instruction above.
3.5 - TRANSPORTATION
To make boiler transport, loading and unloading easier, it features
special "G" hooks on the top for lifting.
The document envelope, inserted in the wood storage compart-
ment, contains:
- Hydraulictestcerticate
- User/System manager instruction manual
- Installation and maintenance instruction manual
- Warranty
- Coupons for returned spare parts
- Technical data adhesive label

be adequately protected.
Description of packs:
1. Boiler body
2. Package containing casing and boiler insulation
3. Package containing casing and smoke chamber insulation
4. Package containing the panel board
5. Packagecontainingtheuegassuckingfan
6. Package containing: air intake header, smoke chamber inspec-
tioncovers,turbulators,handles,sundryscrews,amecontrol
mirror, cleaning accessories. This package is sent inside the
woodstoragecompartment(topdoor).
6
1
2
G
5
4
3
6
1
2
G
5
4
3
3.6 - INSTALLATION
FIREX 2S is a heat generator which withdraws the combustion air
required for the combustion process directly from the environment
in which it is installed.
For this reason, and above all for the safety of the persons using
FIREX 2S, it must be installed in a ventilated room so that a
continuousowofcombustionairisalwaysassured.
It is therefore essential to make air vents linked with the outside
which, in compliance with that indicated by Standard UNI 10683,
have the following features:
1. A minimum free section of 100 cm
2
, or regardless preventing
pressureintheinstallationareafromexceeding4Pa;
2. Bemadeclosetotheoor;
3. Be appropriately protected by metallic mesh or grate so that
theminimumairpassagecross-sectionisnotreduced;
4. Be positioned in such a way that it cannot be obstructed.

by using openings towards an adjacent room
as long as that room is provided with direct


as regulated by standard UNI 10683.
FIREX 2S should be installed in rooms without natural draught
equipment or appliances which can create a vacuum in the room
in relation to the outside environment and therefore hinder the
draughtoftheuegasexhaustsystem(UNI10683).

in front of the boiler no less than the length of the stove itself. You
must at least make sure that the door can open 90° unobstructed.
FIREX 2Scanbeplaceddirectlyontheoorasitisequipped
with a self-supporting frame.
When inspecting compatibility of the heating
system, you should make sure that the support
surface(oor)hasasupportcapacity(kg)suit-
able to bear the weight of the product. If it is not
adequate, suitable safety measures should be
taken (e.g. load distribution plate).
Furthermore,shouldtheoorbemadeofcombustiblematerial
(such as parquet) it should be protected by placing a sheet of
reproofmaterial underneath the FIREX 2S and adequately
wider than the base.
When installation is complete, the boiler must be horizontal and
stable, in order to reduce vibrations and noise.
However, clearance space must be left behind the boiler and on
both sides to allow the casing to be opened for maintenance.
Theremustalsobesucientclearanceforloadingthepellettank.
Do not approach or touch the outer surfaces of the com-

high temperatures following continuous use.
600
1000
1300
600
600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Unical FIREX 2S Installation guide

Type
Installation guide