AND AD-4430C User manual

Type
User manual

AND AD-4430C provides versatile functionality for industrial weighing applications. With its RS-232C interface, you can easily connect it to various devices like PLCs, label printers, or indicators. The front panel buttons and clear LCD display allow for intuitive operation and monitoring of weighing data. Additionally, the AD-4430C offers multiple functions, including accumulation, checkweighing, and auto zero tracking, making it ideal for various industrial weighing tasks.

AND AD-4430C provides versatile functionality for industrial weighing applications. With its RS-232C interface, you can easily connect it to various devices like PLCs, label printers, or indicators. The front panel buttons and clear LCD display allow for intuitive operation and monitoring of weighing data. Additionally, the AD-4430C offers multiple functions, including accumulation, checkweighing, and auto zero tracking, making it ideal for various industrial weighing tasks.

AD4430C USB Connection Instructions
Connecting AD4430C to PC by USB cabl
e
AD4430C Side
USB Micro B Male
PC Side
USBA Male
Turn on power of the AD4430C and connect the
USB cable
A software installation message will appear
shortly as shown below
Open the control panel window and click
device manager
Expand the COM LPT Port option to
reveal USB Serial Port (COM). The number
after COM is the port number
Access the following link http://www.ftdichip.com/FTDrivers.htm
Press click here
③Select setup executable and download
④After downloading CDM v2.12.00 WHQL Certified.exe click the file and
install
What to do if the COM Port is not known
What to do if drivers were not installed automatically
Device Installation
Note: When CDM v2.12.00 WHQL Certified.exe is updated the version number, 2.12.00, will change
USB Cable
WinCT-UFC (Can read and alter multiple settings at once)
AD4430C USB Connection Instructions
Select WinCT-UFC 1.8MB ZIP file on our homepage
(http://www.aandd.jp/products/software/winctufc.html)
Unzip WinCT-UFC_E100.zip and run SETUP.EXE.
Press Ok
Click the computer icon to begin
installation.
Downloading WinCT-UFC
Select “A&D WinCT-UFC”
Installation is complete
AD4430C USB Connection Instructions
WinCT-UFC (Can read and alter multiple settings at once)
WinCT-UFC Connection Settings
Port: Select the number corresponding
to port number noted earlier.
Baud Rate:9600
Stop Bit:1
Terminator:CR/LF
Length:7bit
Parity:E
WinCT-UFC (Can read and alter multiple settings at once)
AD4430C USB Connection Instructions
Connection Operation Instructions
Note: Select multiple rows to change more than one function setting at a time
Enter 0999 into the Send Data
box to read out all functions
Function settings will display in
the Received Data box
Copy the function row for the
setting that is to be altered
Press Send
WinCT-UFC (Can read and alter multiple settings at once)
AD4430C USB Connection Instructions
Paste the data into the Send
Data box to overwrite the
selected value(s)
If the same element is
displayed in the Received Data
box settings were changed
Press stop to finish
Write the new setting data and
press send
Note: Send data and Received Data can be saved to a text editor through the File menu.
WinCT (Can read and alter settings for a single element)
AD4430C USB Connection Instructions
Select WinCT from our company homepage
(http://www.aandd.jp/products/software/winct.html)
WinCT511_Setup_E.zip and click WinCT_Setup.msi in the
WinCT511_Setup folder to install
Click next
Confirm the install destination
and click next
Downloading WinCT
Click next to begin installation
Note: This operation explains how to use WinCT5.11
Users with Windows XP or older operating systems should use WinCT3.00
Users with Windows Vista, 7, 8.1 should use WinCT5.11
Installation is complete
WinCT (Can read and alter settings for a single element)
AD4430C USB Connection Instructions
WinCT-RsCom Connection Settings
Port:Select the port noted earlier.
Baud Rate:9600
Stop Bit:1
Terminator:CR/LF
Length:7bit
Parity:E
Click the RsCom executable from WinCT
WinCT (Can read and alter settings for a single element)
AD4430C USB Connection Instructions
Operation Instructions
Press Start to begin connection
Enter the desired setting
function code into the Command
Data box and press Command
The value displayed in the box
at the bottom of the window is
the current function setting
When the mark at the top left
of the window flickers
connection has been established
WinCT (Can read and alter settings for a single element)
AD4430C USB Connection Instructions
Paste the current function,
change the last 2 digits to the
desired setting and press
Command.
If the settings data appears in
the box at the bottom of the
window settings were changed
successfully. Press stop to finish
editing settings.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

AND AD-4430C User manual

Type
User manual

AND AD-4430C provides versatile functionality for industrial weighing applications. With its RS-232C interface, you can easily connect it to various devices like PLCs, label printers, or indicators. The front panel buttons and clear LCD display allow for intuitive operation and monitoring of weighing data. Additionally, the AD-4430C offers multiple functions, including accumulation, checkweighing, and auto zero tracking, making it ideal for various industrial weighing tasks.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI