Sego Lily SL-SS4FT-11-BLK-K Installation guide

Category
Fireplaces
Type
Installation guide

This manual is also suitable for

OWNER's INSTRUCTIONS MANUAL
Gas Fire Table
User Guide and Instruction Manual
1
SL-FT-1-BLK
SL-FT-1-BRN
SL-FT-1-GRY
LIMITATION OF WARRANTY AND LIABILITY
NOTICE: Read this Limitation of Warranty and Liability Before Using This
Product. If the Terms Are Not Acceptable, Return the Product at Once,
Unopened, and the Purchase Price Will Be Refunded.
It is impossible to eliminate all risks associated with the use of this product. Such
risks arise from weather conditions, the manner of use or application, or other
unknown factors, all of which are beyond the control of the Seller and Manufacturer.
These risks can cause bodily injury or death, ineffectiveness of the product, and
damage to other property. Seller and Manufacturer do not agree to be an insurer of
these risks, you agree to accept these risks.
Seller and Manufacturer warrant that this product is reasonably fit for the purpose
stated in the Owner’s Instructions Manual, subject to the inherent risks described
above, when used in accordance with the Owner’s Instructions Manual under normal
conditions. Seller and Manufacturer provide no other express or implied warranty of
fitness or of merchantability or any other express or implied warranty.
In no event shall Seller or Manufacturer be liable for any incidental, consequential, or
special damages resulting from the use or handling of this product. Buyer’s or user’s
bargained-for expectation is for home use of the product in accordance with the
Owner’s Instructions Manual and under normal conditions and that is the exclusive
remedy of the user or buyer and the exclusive liability of Manufacturer or Seller, for
any and all claims, losses, injuries or damages (including claims based on breach of
warranty or contract, negligence, tort or strict liability) resulting from the use or
handling of this product, shall be the return of the purchase price of the product or, at
the election of Manufacturer or Seller, the replacement of the product
Any claim by buyer or user of this product shall be filed within one (1) year of the date
of injury or damage or the claim will be barred. Buyer and user waive any right to file
any class action claim for product defect, design defect, or failure to adequately warn
of product hazards or safe installation.
This Limitation of Warranty and Liability may not be amended by any oral or written
agreement.
2
FOR OUTDOOR USE ONLY !
If you smell gas and/or hear a gas hissing sound:
1. Immediately, SHUT OFF gas to the appliance.
2.
Extinguish ALL open flames.
3. If odor continues, keep away from the appliance and immediately call your Gas
Supplier or Fire Department.
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity
of this unit and or any other appliance.
An LP Gas tank not connected for use shall not be stored in the vicinity of this or
any other appliance.
Improper installation, adjustment, alteration, service or maintenance can cause
injury or damage to property.
Read and understand the Owner’s Manual thoroughly before installing or
servicing this Fire Table / Column.
If the information in this Owner's Manual is NOT followed exactly, a fire or
explosion may result and cause property damage, personal injury or loss of life.
Save this Owner's Manual and these instructions for future use.
If you are assembling this unit for someone else, give this Owner's Manual to them to read.
CARBON MONOXIDE HAZARD.
This appliance can produce carbon monxide which is odorless.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as inside a camper, tent, car
or home.
3
Part A
.
SAFETY INFORMATION
Before you
assemble or operate this unit, please read carefully this entire Owner's Manual.
Failure to do so may result in a fire, explosion, injury or death.
The installation of this unit must adhere to local codes or either the National Fuel
Gas Code, ANSI Z223. 1/NFPA54, OR CAN/CGA-B149.1, National Gas and Propane
Installation Code.
THIS UNIT IS INTENDED FOR OUTDOOR USE ONLY!
This product shall be used outdoors, in a ventilated space and shall not be used in any enclosed area.
• This unit is to be used with LP Gas / Propane Gas only !
(Propane Gas tank is not attached and not delivered with this unit.
Propane and Gas Tank is sold separately).
• Do not attach a remote gas supply to this unit.
• This unit is NOT intended for Natural Gas.
• Converting this unit to Natural Gas is dangerous and not recommended.
The conversion of this unit shall void the manufacturer warranty.
Do not use any solid fuel or charcoal for this unit.
• When igniting this unit, exercise caution as some gas pooling from the Burner may cause the flame to
flare that could cause injury.
• LP GAS WARNING : Do not use more than 1/4 inch depth
of l
ava rocks / pumice stones above the burner
holes.
Excessive use of lava rocks / pumice stones, will suffocate the flame.
• If the Propane Gas Tank is leaking gas, you can smell, hear a hiss, or sense a leak at the source.
Do the following:
1. Disconnect the Propane Gas tank.
2. DO NOT attempt to fix the problem yourself.
3. Move yourself and all persons away from the immediate area.
4. Only when everyone is at a safe distance away from the Fire Table / Column, contact your Gas
Supplier or Fire Department for help.
• Applying too much Propane Gas may result in gas pooling and will NOT burn.
Allow fresh air into the unit so that the remaining gas may escape.
DO NOT use a flame to check for gas leaks.
• The maximum inlet supply pressure: maximum Gas supply 11 inch w.c. (2.74kPa)
• Use LP propane tanks with the following dimensions: diameter 12 in, height 18 in - capacity 20lbs.
• You must use a Propane Gas Tank that has a collar to protect the Gas Valve.
4
• DO NOT fill ta
nk over 80% full.
• T
he tank system must be set up for vapor withdrawal.
• STOP using if any part of the Propane Gas Tank is damaged.
Rust and dents in tank may be hazardous and should be inspected by a Gas Supplier.
• DO NOT burn anything other than the provided materials for this Fire Table.
• Keep away from the unit for the first 20 minutes after igniting your unit for the first time, as lava rocks /
pumice stones could pop out and cause injury.
Should any rocks pop out, discard them.
• Always ensure that lava rocks / pumice stones are completely dry
before use.
Failure
to do so will cause them to crack or pop.
• DO NOT operate unit until all parts are fully assembled.
• DO NOT paint or color any part of this Fire Table / Column.
• Unit may be hot while in use, DO NOT attempt to move it while in use.
• Never leave this Fire Table / Column unattended while in use.
• This unit is NOT intended for cooking.
• Keep all flammable items away and DO NOT use any other fireplace cover for this unit.
• Keep a safe distance to avoid burning skin or clothing.
• DO NOT sit or rest hands or feet on this Fire Table / Column.
• Never place hands or fingers onto upper portion of this unit while in use.
• Keep all electrical cords and fuel supply hose away from heated surfaces.
• Combustible material should NOT be within 72 inches of the top of the unit, and within 48 inches around
the entire unit.
5
• Keep the appliance area clear and free from combustible material, gasoline and other flammable vapors
and liquids.
• If the flame goes out while burning, turn the gas valve off.
Wait 5 minutes before repeating the initial lighting procedure.
Once you have a flame started, hold down the control knob for 1 minute.
• DO NOT add water into the unit.
• DO NOT operate unit if any part has been under water.
Immediately call for a Qualified Service Technician to inspect the appliance.
Where necessary, secure Qualified Service Technician to replace part(s) of the Control System and any
gas control parts that has been under water.
DO NOT disconnect any part while the unit is in use.
• DO NOT store a spare Propane Gas Tank on or near this unit.
• If the Fire Table / Column is placed indoors for storage, detach the Propane Gas Tank and leave the
tank outdoors.
This unit is for outdoor use ONLY.
• DO NOT operate on a boat or vehicle.
This unit can only be used on any stationary outdoor flat surface ONLY
• Always remove protective cover before operating (where applicable) and / or use of your Fire Table /
Column.
• DO NOT set the Protective Cover (E) over the unit until the Fire Table / Column is turned off and
completely cooled down (where applicable).
• Check for leaks after not using the unit for long periods of time.
• Children must never operate this Fire Table / Column.
Children must be supervised AT ALL TIMES while near this Fire Table / Column.
• The maximum gas supply pressure is 250psi.
• All installation and repair should be done by a Qualified Service Technician.
This unit should be inspected annually and cleaned regularly.
• Inspect all elements of this Fire Table / Column before each use.
If there is damage, the Burner must be replaced.
• Be aware of the hazards of high temperatures and stay away from the unit to avoid any burns or injury.
• The gas supply tank should be constructed and marked with the specifications for the LP Gas tanks of
the U.S. Department of Transportation or the National Standard of Canada CAN/CSA-B339, LP Gas tanks,
spheres and tubes for Transportation of Dangerous Goods and Commission.
The LP Gas tank must have a listed overfilling prevention device and a QCCI or Type I, LP Gas tank
connection.
• This heating appliance should NOT be used on plastic, artificial wood desks or any desk.
6
• Children and
adults should be alerted to the hazards of high surface temperatures and should stay away
to avoid burns
or clothing ignition.
• Young children
MUST BE carefully supervised at all times when they are in the area of this appliance.
• Clothing or
other flammable materials shall NOT be hung from the appliance or placed on or near the
appliance.
• Any guard
or other protective device removed for servicing the appliance shall be replaced prior to
operating and use
of this appliance.
• Installat
ion and repair(s) should be done by a Qualified Service Technician.
The appliance shoul
d be inspected before use. If you suspect there are issues, contact a Qualified
Service person.
More fr
equent cleaning may be required as necessary.
It is
imperative that the control compartment, burners and circulating airways of the appliance are kept
clean.
When APPLICABLE:
• Keep gas t
ank at least 5 feet away from unit when lit (if external tank).
Allow Fire Burner / Column to cool down completely before placing on lid.
• Keep the hose away from any pathways to eliminate any accidental damage (if external tank).
• DO NOT use Fire Table / Column while lid is installed.
Always remove the lid while Fire Table / Column is in use.
Use only the Regulator (12/19) and Hose (12) assembly provided with this unit. Replacement parts must
be supplied directly by manufacturer.
Inspect the Burner (8) before use of this unit.
If the Burner (8) shows any kind of damage, DO NOT operate the appliance. For assistance with repair or
replacement of the Burner (8) or any other parts, call : 1- 818-435-3985.
NOTE: You must follow all steps to properly assemble this Fire Table / Column. Make sure the Gas Valve
is turned “OFF” before assembling.
DO NOT attempt to assemble without proper tools.
7
Part B.
User's Guide to Parts and Accessories of The Regulator,
Charge Valve of the Cylinder and Steps to Connecting the
Gas Tank to the Fire Table /Column.
T
his Safety Information passage holds information that :
1 ) shows you the Regulator ( pre-connected to the Fire Table / Column )
2 ) the Charge Valve of the Gas Tank and its relevant Valves.
There are Fire Table / Column that holds the Gas Tank INTERNALLY
and EXTERNALLY.
The Ow
ner / User must know all the different parts : Charge Valves and Regulator.
This picture shows different parts of the Charge Valve of the Gas Tank and the Regulator (12/19 ) is pre-
connected to the Fire Table / Column. the different components and parts of the Gas Tank and the Fire
Table / Column Regulator, as show in the diagram below.
Pic. A : Shows the Charge Valve of the Cylinder with
the different Valves and Coupling Nut, these forms
the top of the Gas Cylinder.
Pic. B : Shows the Regular pre-connected to a hose.
This Regulator is pre-connected to the Fire Table /
Column.
There are 2 kinds of Fire Table / Column.
Type 1 : Fire Table / Column that has an internal housing for Gas Tank Cylinders, where the Gas Tank is
held inside the Table / Column. The Gas Tank is held and bound in place inside the Fire Table / Column
with the Metal Ring and locked down with a Wing Screw / Nut.
Type 2 : Fire Table / Column that has the Gas Tank externally visible, whereby the hose shall be NO
SHORTER than 5 feet.
In some cases, you may have purchased a separate Gas Tank Holder to hold the Gas Tank. In this case,
the 5 feet distance between the Fire Table / Column to the Gas Tank applies too.
8
Part C.
FIRE TABLE / COLUMN PARTS INTRODUCTION
Below is an introduct
ion to all the parts that forms your Fire Table / Column.
Each part is different and holds its own function.
DO NOT attempt to change and or remove any part(s) thereof.
In the event of servicing and or operational issues, contact Qualified Services Technical Support and or
seek Qualified Service Technician.
This line art below demonstrates the internal components of the Burner.
For your convenience all of the above components are individually described on the next page.
9
It
em Picture Description Qty
01 Guard 1
02 Thermocouple 1
04
Ignition Pin 1
05
1
06
Main Frame of Fire Table
07
Lava Rocks
1 box
08
Burner
1
09
Nozzle
1
10
Corrugated Pipe
1
11
Switching Valve 1
12
Regulator Valve with Gas
Hose
1
13
Control Knob
1
Ignitor
1
Foot
4
Part Descriptions
03
10
Part D.
Item Picture Description Qty
A
Metal lid
1
B
AA Battery
1
C
Panel
2
D
Panel D
1
E
Protective Cover
1
F
Panel F
1
G
1
H
Table Top
s 
Bolt (M6*0MM)
4
12
User's Guide Parts and Accessories of Fire Table / Column.
User's Guide to various Parts and Accessories to form your complete Fire Table /Column.
Before you start to assemble this product, make sure all parts are present. Compare
parts with package contents list.
If any parts are missing or damaged, DO NOT attempt to assemble the product.
Hardware
CONTENTS
Before Beginning Assembly:
Item Picture Description Qty
M6 Washer
Allen Wrench
1
Bolt (M6*35MM)
Bolt (M6*15MM)
8
8
11
1.
Attach panel (D) and the panel (F) to the table top (G) using 4pcs of Bolts (1) and 4pcs M6 washer (4)
with
Allen Wrench (5). Do not fully tighten.
2. Attach panel (C) with Panel (D ) and Panel (F ) together using 8pcs Bolts (2) and 8pcs M6 washer (4)
with Allen Wrench (5). Do not fully tighten.
ASSEMBLY INSTRUCTIONS
Part E.
12
4.
3.
Attach adjust foot (H ) to the botom of fire pit using 8pcs of Bolts (3) with Allen Wrench (5). Tighten the bolts.
Put the metal lid on the table top of fire pit.Then tighten all the bolts.
13
3DUWF
86(56,16758&7,216
+HUHDUHWKHEDVLFVWHSVWRKHOS\RXOLJKWDQGXVH\RXU)LUH7DEOH
67(3
 &KHFNWKDWWKH&RQWURO.QREIRUWKHJDVsXSSO\V\VWHPLVWXUQHGWRWKH³2))´SRVLWLRQEHIRUHVWDUWLQJDQ\
DVVHPEO\

Place a 20 lb Propane Gas Tank (not included) into a secure position
14
67(3
7XUQWKH&\OLQGHU9DOYHRQWKHWDQNLQDFORFNZLVHGLUHFWLRQWR78512))6833/<RIWKH/3*DVsXSSO\
-$WWDFKWKHSUHDVVHPEOHG5HJXODWRUIURPWKH)LUH7DEOHWRWKH&\OLQGHU9DOYHE\WXUQLQJWKH
%ODFN5HJXODWRU&RXSOLQJ1XWFORFNZLVH
0DNHVXUHLWLVIDVWHQHGVHFXUHO\DQGWLJKWHQFRQQHFWLRQVE\+$1'RQO\
67(3 4
4
5HPRYH WKH (OHFWURQLF ,JQLWHU &DS RQ WKH HOHFWURQLF ,JQLWHU E\ XQVFUHZLQJ DQG VOLGH WKH %DWWHU\% LQWR
WKH EDWWHU\ slot(14). Make sure the positive side of the Battery(B) faces outwards. Screw the Electronic Igniter
Cap(14) over the battery, tightly.
15
67(3 5
6XEMHFW WR \RXU SUHIHUHQFH \RX PD\ SRXU /DYD5RFNV RYHU WKH %XUQHU 5LQJ
7KH *XDUG 0867 127 %( BLOCKED.5HIHUWR JXLGDQFH EHORZ
'RQRW SODFHPRUHWKDQLQFKGHSWKRIODYDURFNV DERYHWKH EXUQHU KROHV'RLQJVR ZLOOVXIIRFDWHWKHIODPH
'RQRW SODFHPRUHWKDQ3kg RIODYDURFNV DERYHWKH EXUQHU KROHV 'RLQJVRZLOOVXIIRFDWHWKHIODPH
:$51,1* )LUH7DEOHDQG/3&\OLQGHUPXVWEHDWDPLQLPXPRILQFKHVDSDUW
7RHQVXUHSURSHUIXQFWLRQWKH*XDUG RQWKH%XUQHU VKRXOGQHYHUKDYHODYDURFNV$ FRYHUHGRYHULW
16
Part G.
Before performing a leak test, be sure:
1.
)
DO NOT press the Ignitor .
2.
) You are in a spacious outdoor area.
Connect the Propane Gas tank to the Regulator (12 /19) and turn the Valve (22) on the unit to the “OFF”
position.
Brush soap and water mixture onto all connections.
Turn the gas supply on;if extra large bubbles form on any connection there may be a leak. If you smell
gas or a leak is discovered, IMMEDIATELY turn the gas valve off, disconnect Propane Gas tank.
Do not use the appliance until the leak is repaired
The Fire Table / Column has a Door. Open the door. Inspect the Gas Hose (12) before use the Fire Table /
Column.
If there are signs of wear or abrasion on the hose, you must replace the Gas Hose (12).And the Gas Hose
must be supplied directly by manufacturer.
Lava rocks / pumice stones could pop up and strike somebody’s face during the process of lighting this
unit.
Stand away from the Fire Table / Column for the initial 20 minutes after igniting.
Observe flame colour and flame height when the
Fire Table/Column after being lit :
1.
) Flame color should be yellow / blue.
2. ) Flame height burns at 2 - 10 inches high.
Wait 10 minutes after extinguishing flame prior to replacing a lid (if applicable) or protective cover onto
the Fire Table / Column.
SAFETY INFORMATION - OPERATIONS
2inchesto10inches.
17
Part H.
SAFETY INFORMATION
USING YOUR FIRE TABLE / COLUMN
Before each use, inspect the Gas Hose (12). Replace Gas Hose(12) if there are any signs of cutting, wear
or abrasion.
Before you light your Fire Table / Column, please proceed / adopt the following steps :
1.
Make sure the Control Knob (13) is in the “OFF” position.
2. Open the Door (07) and slowly open the Valve (22) on the Propane Gas Tank by turning the Control
Knob (13) counterclockwise.
3.
Close the Door (07) on the Main Frame (06) of the Fire Table / Column.
4. Push and hold in the Electronic Ignitor (14 ) to create sparks within the electrode, continue to hold.
5. Push in the Control Knob (13) and turn to the “LOW” position.
Keep holding down the Control Knob (13) to allow gas to flow for 15 seconds.
6. If ignition doesn’t occur within a few seconds release the Control Knob (13) and rotate to the “OFF”
position.
Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
7.
On
ce the Fire Table / Column is lit, the flame intensity may be controlled by turning the Control Knob
(13) between the “LOW” and “HIGH” positions.
8.
O
bserve flame height when lit:
8.1. ) Flame color should be yellow / blue.
8.2. ) Flame height burns at 2 - 10 inches high.
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Sego Lily SL-SS4FT-11-BLK-K Installation guide

Category
Fireplaces
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI