CONTENTS
4. Troubleshooting ....................................................................................69
4-1. Functions for failure diagnosis .................................................................................................................... 69
4-1-1. Test mode (manual operating / manual defrosting function) ...................................................... 69
4-1-2. Display function of Communication error ....................................................................................... 71
4-1-3. Self-diagnostic function ..................................................................................................................72
4-1-4. Display function of Load condition .................................................................................................77
4-1-5. Display function of Load condition (Sparkling water model) .......................................................79
4-1-6. Cooling Off Mode setting function ................................................................................................. 80
4-1-7.
AP Mode Function and E-Smart Icon ................................................................................................... 80
4-1-8. Option setting function .....................................................................................................................81
4-1-9. Option TABLE .................................................................................................................................. 83
4-2. Troubleshooting by symptom ..................................................................................................................... 88
4-2-1. When there is no power at Inverter PCB (F/R Room Inverter) .................................................. 88
4-2-2.
The LED blinking frequency depending on the protection functions (F/R Room Inverter PCB)
........... 90
4-2-3.
When a "1E","2E", "4E", "5E", "6E", "7E", ''9E, "11E", "13E", "24E", "29E" error occures(defrosting failure)
.........91
4-2-4. When occur the cooling defect by a lot of frosting on the Fridge compartment ........................92
4-2-5. When an error occurs in self diagnostic mode (in case of a sensor error) ............................ 93
4-2-6. When the Fan does now operate(F, R, CV, C-FAN) ................................................................. 94
4-2-7. When the Fan does now operate (ICE ROOM - FAN) .............................................................. 95
4-2-8. When the ICE MAKER does not operate ..................................................................................... 96
4-2-9. When water does not supply at Ice Maker ..................................................................................97
4-2-10. When Cubed or Crushed ice does not dispense properly ..................................................... 98
4-2-11. When COVER ICE ROUTE MOTOR (GEARED MOTOR) does not work properly ................... 99
4-2-12. When the alarm is heard continuously (buzzer sound) ...........................................................100
4-2-13. When the DISPENSER Panel PBA does not work properly ....................................................102
4-2-14. When the MAIN Panel PBA does not work properly ...............................................................103
4-2-15. When the Micro Hole Panel PBA does not work properly ......................................................104
4-2-16.
When the internal LED Lamp of the F-Room or R-Room or Cool select-room is not turned on
.............105
5. PCB Diagram ...................................................................................... 108
5-1. PCB Layout with part positions (Main Board) ...........................................................................................108
5-2. Inverter PCB Layout positions ...................................................................................................................109
5-3. Connector Layout with part positions (Main Board) ................................................................................ 110
5-4. Connector Layout with part positions ........................................................................................................ 111
6. Wiring Diagram .................................................................................... 112
6-1. Sparkling/Dispenser Model .........................................................................................................................112
6-2. Dispenser Display+SODA PBA .................................................................................................................113
7. BLOCK DIAGRAM ................................................................................. 114
7-1. Dispenser + Sparkling + MHD ....................................................................................................................114
7-2. Whole block diagram (ISB-LC5) ................................................................................................................115
8. References .......................................................................................... 116
8-1. Glossary .........................................................................................................................................................116
8-2. French Heater Control Using a Humidity Sensor .....................................................................................118
8-3. Model Numbering Convention ....................................................................................................................119
8-4. Troubleshooting. Check the following before calling the service centre .............................................120
8-5. Optimum Operating Environment for Sparkling water ............................................................................126