VS1 Troubleshooting Manual Responding to alarms
Page 1-10 Issue 10.0 2018-10-29
+15V Supply
Fail
(+15V Fail)
PS (amber) This alarm occurs if the +15 V supply from the PS distribution
PWB (A2) is outside of its acceptable voltage range (between
+13.5 V and +16.5 V). The VS1 takes no action on this alarm.
Check for a +48V Supply Fail alarm: If present, follow the
associated troubleshooting procedure. If not present, use a digital
multimeter to measure between TP1 (+15 V) and TP8 (ground) of
the PS distribution PWB. If the measured value is not within the
acceptable range, the power supply circuitry on the PS distribution
PWB has likely failed. If the measured value is within the
acceptable range, check ribbon cable W2 for damage and that
connectors W2P1 and W2P2 are properly seated in A1J12 and
A2J2 respectively. If there are no visible problems with the ribbon
cable, suspect the sampling circuitry on the PS distribution PWB.
If necessary, replace the PS distribution PWB (see “PS
Distribution PWB Replacement” on page 1-46). If the alarm
persists after replacing the PS distribution PWB, suspect the
exciter/control PWB (A1).
-15V Supply
Fail
(-15V Fail)
PS (amber) This alarm occurs if the -15 V supply on exciter/control PWB (A1)
is outside of its acceptable voltage range (between -13.5 V and
-16.5 V). The VS1 takes no action on this alarm. Check for a +15V
Supply Fail alarm: If present, follow the associated
troubleshooting procedure. If not present, use a digital multimeter
to measure between TP11 and TP7 (ground) of the exciter/control
PWB. If the measured value is within the acceptable range,
suspect the sampling circuitry on the exciter/control PWB. If not,
use a digital multimeter to measure between TP23 and TP4
(ground). The measured voltage should be between +13.5 V and
+16.5 V. If the measured voltage is within the acceptable range,
the power supply circuitry on the exciter/control PWB has failed.
Replace the exciter/control PWB (see “Exciter/Control PWB
Replacement” on page 1-43). If not, check ribbon cable W4 for
damage and that connectors W4P1 and W4P2 are properly
seated in A1J11 and A2J3 respectively. If there are no visible
problems with the ribbon cable, contact Nautel for further support.
Alarm Name
AUI and
(Front Panel)
Front Panel
LED (color) Description and Troubleshooting Action