American Standard 2645VA User manual

Type
User manual
753737-100 Rev. B
1
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the
whirlpool installation are your selected fittings and electrical connections.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
MODEL 2422L / LA / V / VA 5' x 32"
MODEL 6060L / V CORNER
MODEL 2771L / LA / V / VA 5' x 36"
MODEL 2645L / LA / V / VA OVAL
MODEL 7236L / LA / V / VA 6' x 36"
MODEL 2425L / V - LHO 5' x 32" IA-LHO
MODEL 2425L / V - RHO 5' x 32" IA-RHO
MODEL 2732 RENAISSANCE
MODEL 2901L SAVONA
MODEL 2908L / LA REMINISCENCE
MODEL 2711L ELLISSE
MODEL 2773L CADET 6' x 36"
MODEL 2774L / LA CADET 6' x 42"
MODEL 2775L CADET CORNER
MODEL 2805L 5' x 42"
© AS Americas Inc.00
All product names listed herein are trademarks
of AS Americas Inc. unless otherwise noted.
FOR AFTER-SALES SERVICE CALL 1 (00) -10 WEEKDAYS.
INSTALLATION GUIDE FOR
LIFETIME/ EVOLUTION™
AND RENAISSANCE
WHIRLPOOLS AND BATHTUBS
753737-100 Rev. B
TABLE OF CONTENTS:
Safety Instructions............................................................................Page 3
General Information..........................................................................Page 
Optional Components.......................................................................Page 
Specifications....................................................................................Page 5
Roughing-in Reference.....................................................................Page -
Framing and Support Instructions.....................................................Page 
Mounting Instructions........................................................................Page 10
Electrical Connections.......................................................................Page 11
00L/V Corner EZ-Install Heater.....................................................Page 1
Drain Connection and System Test...................................................Page 13
Care and Cleaning.............................................................................Page 13
Warranty............................................................................................Page 1-15
753737-100 Rev. B
3
!
!
!
!
!
!
!
SAVE THESE INSTRUCTIONS
WARNING:
Risk of personal injury.
Do not permit children to use this unit without adult supervision.
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING:
Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
0 inches (15mm) of this unit.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than /3
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING:
No Food or Alcoholic Beverages.
Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or
hyperthermia resulting in loss of consciousness or even drowning.
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by
American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button
being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this hydromassage
bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no.  AWG solid
copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as
needed to comply with local requirements. To reduce the risk of an electric shock, connect this connector the
grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors
supplying this unit.
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
753737-100 Rev. B
Lifetime™/Evolution™ Corner
Renaissance
Lifetime™/Evolution™ 5' x 3"
Lifetime™/Evolution™ 5' x 3"
Lifetime™/Evolution™ ' x 3"
Lifetime™/Evolution™ 5' x 3" IA
Lifetime™/Evolution™ Oval
Lifetime™ Savona
Lifetime™ Reminiscence
Lifetime™ Ellisse
Lifetime™ Cadet ' x 3"
Lifetime™ Cadet ' x "
Lifetime™ Cadet Corner
Lifetime™ 5' x "
00
73

771
73
5
5
01
0
711
773
77
775
05
INCLUDED
NOT AVAILABLE
X
X
X
X
X
X
X
X
X
X
X
X
0707.00
0.01
1.01
1.01
71.01
INTEGRAL
.01
NOT
AVAILABLE
NOT
AVAILABLE
NOT
AVAILABLE
7.01
7.01
NOT
AVAILABLE
10.00
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
15.500.00
15.500.00
15.500.00*
15.500.00*
15.500.00*
15.500.00*
15.500.00
15.500.00
15.500.00
15.500.00
15.500.00
15.500.00
15.500.00
153.70.00
Optional Components
(Not Included)
Required Components
(Not Included)
E-Z
Install
Heater
Apron
Kit
Tile
Bead
Kit
Bath
Filler
153.70.XXX
153.70.XXX
15.05.XXX*
15.05.XXX*
15.05.XXX*
15.05.XXX*
153.70.XXX
153.70.XXX
153.70.XXX
153.70.XXX
153.70.XXX
153.70.XXX
153.70.XXX
153.70.XXX
Drain
(Specify
Finish)
Drain
(White)
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x  Stringers
• Drop Cloth
• Cement, Plaster, Grout
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your
vendor immediately. After inspection and during installation, protect the bath from construction damage. Before
installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to
check for leaks that may have resulted from shipping damage or mishandling! Do not make modifications to
the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance
of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others.
For electrical requirements, refer to section titled “Whirlpool Electrical Installation Instructions”.
Check for availability of optional American Standard wall tiling bead (required for recess installation).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
Description
Model
Number
LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):
• For these components please see your Vendor.
* These models require American Standard Lifetime™ Drain 15.05 or 15.500
!
WARNING: Do not lift whirlpool by the piping harness at any time.
753737-100 Rev. B
5
SPECIFICATIONS:
GENERAL SPECIFICATIONS FOR LIFETIME / EVOLUTION / RENAISSANCE WHIRLPOOLS AND BATH TUBS
TABLE 1
SIDE VIEW
DRAIN / OVERFLOW
END VIEW
L
H
W
C
A
B
J
00L / V
Corner*
L / LA /
V / VA
5' x 3"
771L / LA /
V / VA
5' x 3"
73L / LA /
V / VA
' x 3"
5L / V
5' x 3”
IA-LHO /
IA-RHO
5L / LA /
V / VA
Oval
73
Renaissance
01L
Savona
0L / LA
Reminiscence
711L
Ellisse
773L
Cadet ' x 3"
77L / LA
Cadet ' x "
775L
Cadet Corner
05L
5' x "
A 1"
(57 mm)
B 13-3/"
(3 mm)
A 0-1/"
(511 mm)
B 11"
(7 mm)
A 0-1/"
(511 mm)
B 11"
(7 mm)
A 0-1/"
(511 mm)
B 11"
(7 mm)
A 1-1/"
(5 mm)
B 10-1/"
( mm)
A 15-1/"
(37 mm)
B -1/"
(0 mm)
A 1-1/"
(1 mm)
B -1/"
(15 mm)
A 1-1/"
(13 mm)
B -1/"
(15 mm)
A 15-1/"
(3 mm)
B "
(15 mm)
A 17-3/"
(1 mm)
B "
(10 mm)
A 17"
(3 mm)
B 1"
(305 mm)
A 1-1/"
(13 mm)
B -1/"
(15 mm)
A 1-1/"
(1 mm)
B -1/"
(15 mm)
A 1-1/"
(13 mm)
B -1/"
(15 mm)
130mm
(5-5/)
3mm
(3-1/)
3mm
(3-1/)
3mm
(3-1/)
73mm
(-7/)
mm
(1-3/)
3mm
(1-1/)
10mm
(5-1/)
15mm
()
10mm
()
57mm
(-1/)
57mm
(-1/)
7mm
(11)
15mm
()
C 1-1/"
(5 mm)
C 0"
(50 mm)
C 0"
(50 mm)
C 0"
(50 mm)
C 0-1/"
(515 mm)
C 1-1/"
( mm)
C 1-1/"
( mm)
C 0"
(50 mm)
C 1-1/"
( mm)
C 1-1/"
(5 mm)
C 1-1/"
( mm)
C 1-1/"
( mm)
C 1-1/"
( mm)
C 1-1/"
(5 mm)
Template
provided
5-1/"
(15 mm)
x 30-1/"
(77 mm)
5-1/"
(15 mm)
x 3-1/"
(7 mm)
70-1/"
(170 mm)
x 3-1/"
(7 mm)
N/D
"
(15 mm)
x 3"
(3 mm)
5-1/"
(15 mm)
x 31-1/"
(00 mm)
-3/"
(177 mm)
x " (107
mm)
Template
provided
70-1/"
(171 mm)
x -1/"
(111 mm)
70-1/"
(171 mm)
x 3-1/"
(70 mm)
70-1/"
(171 mm)
x 0-1/"
(1537 mm)
Template
provided
5-1/"
(1 mm)
x 0-1/"
(10 mm)
Template
7510-100
0-3/1"
(15 mm)
x 30-1/"
(77 mm)
0-3/1"
(15 mm)
x 3-1/"
(7 mm)
7-3/1"
(133 mm)
x 3-1/"
(7 mm)
0-3/1"
(15 mm)
x 30-1/"
(77 mm)
-3/1"
(11 mm)
x 3-1/"
(7 mm)
0-3/1"
(15 mm)
x 31-1/"
(7 mm)
7-3/1"
(133 mm)
x -1/"
(100 mm)
AS
DESIRED
7-3/1"
(133 mm)
x "
(11 mm)
7-3/1"
(133 mm)
x 3"
(1 mm)
7-3/1"
(133 mm)
x "
(107 mm)
0-3/1"
(15 mm)
x "
(107 mm)
L 1mm (7-3/")
W 11mm (5-3/")
H 5mm (1-1/")
L 15mm (0")
W 13mm (3")
H 5mm (1-1/")
L 15mm (0")
W 1mm (3")
H 5mm (1-1/")
L 1mm (7")
W 1mm (3")
H 5mm (1-1/")
L 15mm (0")
W 13mm (3")
H 51mm (0-1/")
L 17mm (")
W 1mm (3")
H 50mm (1-3/")
L 15mm (0")
W 3mm (3-3/")
H 50mm (1-3/")
L 1mm(7")
W 111mm(")
H 55mm(")
L 17mm (")
W 1mm (3")
H 1mm (-1/")
L 1mm (7")
W 11mm (")
H 5mm (1-1/")
L 1mm (7")
W 1mm (3")
H 50mm (1-3/")
L 1mm (7")
W 107mm (")
H 50mm (1-3/")
L 15mm (5")
W 15mm (0")
H 50mm (1-3/")
L 15mm (0")
W 107mm (")
H 5mm (1-1/")
10 lb.
( kg.)
7 lb.
(3 kg.)
75 lb.
(3 kg.)
10 lb.
( kg.)
 lb.
( kg.)
 lb.
( kg.)
5 lb.
(30 kg.)
15 lb.
( kg.)
5 lb.
(3 kg.)
1 lb.
(7 kg.)
101 lb.
(5 kg.)
137 lb.
( kg.)
130 lb.
(5 kg.)
130 lb.
(5 kg.)
 lb. (37 kg)/
(117 kg/sq.m)
5 lb./sq.ft.
0 lb. (313 kg)/
(0 kg/sq.m)
53 lb./sq.ft.
00 lb. (33 kg)/
(0 kg/sq.m)
53 lb./sq.ft.
1031 lb. (7 kg)/
(0 kg/sq.m)
57 lb./sq.ft.
75 lb. (30 kg)/
( kg/sq.m)
5 lb./sq.ft.
50 lb. (3 kg)/
(175 kg/sq.m)
3 lb./pies
cuadrados
5 lb. (37 kg)/
(13 kg/sq.m)
 lb./sq.ft.
3 lb. (1 kg)/
(11 kg/sq.m)
3 lb./sq.ft.
5 lb. ( kg)/
(11 kg/sq.m)
0 lb./sq.ft.
5 lb. (3 kg)/
(15 kg/sq.m)
0 lb./sq.ft.
751 lb. (31 kg)/
(10 kg/sq.m)
0 lb./sq.ft.
1 lb. (37 kg)/
(03 kg/sq.m)
 lb./sq.ft.
75 lb. (33 kg)/
(115 kg/sq.m)
3 lb./sq.ft.
 lb. (310 kg)/
(11 kg/sq.m)
3 lb./sq.ft.
Optional
Optional
Optional
Optional
Included
Optional
Optional
Optional
Optional
Optional
Optional
Included
Optional
Optional
Optional
Optional
Optional
Not
Available
Optional
Optional
Optional
Optional
Optional
Optional
Optional
 gal.
(35 l.)
7 gal.
(0 l.)
7 gal.
(3 l.)
111 gal.
(0 l.)
70 gal.
(5 l.)
5 gal.
(1 l.)
55 gal.
(0 l.)
 gal.
(35 l.)
 gal.
(57 l.)
5 gal.
(30 l.)
7 gal.
( l.)
 gal.
(310 l.)
75 gal.
( l.)
 gal.
(3 l.)
71 gal.
( l.)
33 gal.
(15 l.)
50 gal.
(1 l.)
53 gal.
(01 l.)
3 gal.
(1 l.)
 gal.
(15 l.)
1 gal.
(155 l.)
 gal.
(3 l.)
55 gal.
(0 l.)
7 gal.
(0 l.)
 gal.
(3 l.)
 gal.
(5 l.)
0 gal.
(7 l.)
5 gal.
(17 l.)
Description
Drain /
Overflow
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product
Weight
Apron /
Mounting
Heater Ready
for Field
Installation
Gallon to
Overflow
Whirlpool
Operating
Volume
Height to
Underside
of Deck: C
Dimensions
L-W-H
753737-100 Rev. B
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z1.1 AND A11.1.7.
ROUGHING-IN REFERENCES
5' x 32" (MODEL 2422L / LA / V / VA)
CUT OUT IN FLOOR
FOR DRAIN
0"
(15mm)
3"
(13mm)
7-1/"
(11mm)
10-1/"
(7mm)
3"
(7mm)
-7/"
(73mm)
"
(15mm)
13-1/"
(33mm)
1"
(0mm)
5' x 32" IA-LHO (MODEL 2425L/V-LHO) - shown
5' x 32" IA-RHO (MODEL 2425L/V-RHO)
0"
(15mm)
3"
(1mm)
3"
(7mm)
7-1/"
(11mm)
"
(15mm)
11"
(7mm)
13-3/"
(3mm)
CUT OUT IN FLOOR
FOR DRAIN
5' x 36" (MODEL 2771L / LA / V / VA)
7"
(1mm)
3"
(1mm)
7-3/"
(17mm)
11"
(7mm)
3-1/"
(3mm)
3"
(7mm)
"
(15mm)
13-3/"
(3mm)
CUT OUT IN FLOOR
FOR DRAIN
6' x 36" (MODEL 7236L / LA / V / VA)
"
(17mm)
5-3/"
(137mm)
"
(15mm)
3"
(1mm)
-1/"
(10mm)
3"
(7mm)
11-1/"
(mm)
1-3/"
(mm)
1"
(57mm)
CUT OUT IN FLOOR
FOR DRAIN
OVAL (MODEL 2645L / LA / V / VA)
0"
(15mm)
3"
(13mm)
11"
(7mm)
7-3/"
(17mm)
13-3/"
(3mm)
"
(15mm)
3"
(7mm)
3-1/"
(3mm)
CUT OUT IN FLOOR
FOR DRAIN
3-1/"
(3mm)
753737-100 Rev. B
7
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
ROUGHING-IN REFERENCES
SAVONA (MODEL 2901L)
CORNER (MODEL 6060L / V)
7"
(178mm)
76-3/4"
(1949mm)
54-1/2"
(1384mm)
65-3/8"
(1661mm)
3"
(76mm)
7" (178mm)
15"
(381mm)
5-5/8"
(143mm)
17-3/4"
(451mm)
10"
(254mm)
13-3/4" (349mm)
CUT OUT
IN FLOOR FOR DRAIN
72”
(1829mm)
44”
(1118mm)
3”
(76mm)
12”
(305mm)
8”
(203mm)
RECOMMENDED FITTING LOCATION
64 X 279mm (2-1/2 X 11)
6”
(152mm)
11-1/2”
(292mm)
5-1/2"
(140mm)
CADET CORNER (MODEL 2775L)
1
52
4
m
m
(60)
70mm REF.
(2-3/4)
165mm
(6-1/2)
279mm
(11)
229 X 305mm
(9 X 12)
CUTOUT IN
FLOOR FOR
DRAIN
OUTLINE OF
CUTOUT
2159mm
(85)
1080 mm
(42-1/2)
C/L
1524mm
(60)
1076mm
(42-3/8)
1080mm
(42-1/2)
PUMP
C/L OF DRAIN OUTLET
5X42 (MODEL 2805L)
1524mm
(60)
INTEGRAL
FITTING DECK
762mm
(30)
1067mm
(42)
PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
C/L OF
DRAIN
19mm
(3/4)
PUMP
305mm
(12)
152mm
(6)
RENAISSANCE (MODEL 2732)
60"
(1524mm)
33"
(838mm)
5-7/8"
(149mm)
12"
(305mm)
6"
(152mm)
3"
(76mm)
8-1/2"
(216mm)
16-1/2"
(419mm)
CUT OUT IN FLOOR
FOR DRAIN
1-1/2"
(38mm)
PROVIDE ACCESS TO
PUMP FOR
SERVICING ON ALL
INSTALLATIONS
RECOMMENDED
FITTING
LOCATION
64 X 330mm
(2-1/2 X 13)
OUTLINE OF CUTOUT
1486mm x 1029mm
(58-1/2 x 40-1/2)
178mm x 381mm
(7 x 15)
FLOOR
CUTOUT
753737-100 Rev. B
REMINISCENCE (MODEL 2908L / LA)
 x 305mm
(X 1)
FLOOR
CUTOUT
mm REF.
(-1/)
17mm
()
PUMP
1mm
(3)
57mm
(1)
330mm
(13)
INTEGRAL
FITTING
DECK
15mm
()
OUTLINE OF
CUTOUT
C/L OF DRAIN
OUTLET
PROVIDE ACCESS TO
PUMP FOR SERVICE
ON ALL INSTALLATIONS
CADET 6 x 36 (MODEL 2773L)
RECOMMENDED FITTING LOCATION
 X 330mm (-1/ x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING
LOCATION #1
1 mm
(7)
0 mm
(35-3/)
OUTLINE OF CUTOUT
171 mm x 70 mm
(70-1/ X 3-1/)
5 mm
(17-7/)
mm
()
305 mm
(1)
57mm
(-1/)
() JETS
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
1 mm
(3/)
 mm
()
C/L OF DRAIN
() AIR VALVES
PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS
ELLISSE (MODEL 2711L)
1mm
(7)
7mm
(3-1/)
OUTLINE OF CUTOUT
171 X 111
(70-1/ X -1/)
C/L OF
DRAIN
10mm
()
PUMP
305mm
(1)
11mm
()
mm x 35mm
(x 1) FLOOR
CUTOUT
RECOMMENDED
FITTING LOCATION
 X 7mm (-1/ X 11)
OPTIONAL DECK
FITTING AREA
GRAB BAR
FITTING AREA
PROVIDE ACCESS TO
PUMP FOR SERVICE
ON ALL INSTALLATIONS
CADET 6 x 42 (MODEL 2774L / LA)
C/L OF DRAIN
RECOMMENDED FITTING LOCATION
 X 330mm (-1/ x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING
LOCATION #1
1 mm
(7)
107mm
()
533mm
(1)
mm
()
305 mm
(1)
57mm
(-1/)
() JETS
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
1 mm
(3/)
 mm
()
() AIR VALVES
PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS
OUTLINE OF
CUTOUT
171mm x 10mm
(70-1/ X 0-1/)
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z1.1 AND A11.1.7.
ROUGHING-IN REFERENCES
753737-100 Rev. B
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure
roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump
and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used
as the primary access opening.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
AS DESIRED
G
CUTOUT
C

(10 mm)
1
(305 mm)
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
TYPICAL RECESS INSTALLATION

(10 mm)
1
(305 mm)
C
E
D
W
LEVELING
STRINGERS
TILE
TILE
BEAD
STRIP
LEVELING STRINGER
1 x  (not for support)
BATH
ADHESIVE
SEALANT
WALLBOARD
NOTE: Tile bead kit not included and
must be purchased separately.
C
TYPICAL INSTALLATION
FIGURE 1
This bath must be supported along its entire bottom. Use mortar as bedding
material (do not use sand or foam). Apply enough mortar to support the complete
bottom of the bath. After the mortar has been poured, and before it sets, position
whirlpool or bath within recess until the rim is leveled against the leveling stringers (see
"Typical Recess Installation") shown below.
The rim of the bath must not support weight. Allow the mortar material to completely
harden before applying weight to the rim or bottom of the bath. Any finish material such
as tile or wall board must be self-supporting if it contacts the deck of the bath.
Replace whirlpool and re-shim the integral support feet, shimming the entire length of
the support feet. Secure the shims using construction adhesive, silicone, mortar or
equivalent materials. While not a necessity, the use of a foundation base consisting of
cement, mortar, or grout will help provide a solid and secure installation.
3. Install drain components to the whirlpool following the drain installation instructions. Before
replacing your whirlpool for final installation, be certain that an opening has been provided in
the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening
size (shadowed) and location dimensions. The drain/overflow of the bath extends below the
bottom of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath, water, and
bather. Refer to Table 1 under total weight for your model.
For Models:
2425L/V-LHO, 2425L/V-RHO and 2732L/V;
For Models:
2645L/V, 2771L/V, 6060L/V, 7236L/V, 2422L/V and 2422LA/VA;
. Remove the whirlpool and attach a 1 x  stringer to the studs, with the top of the stringer touching the traced line.
The rim of the bath must not support weight.
1. Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
!
!
!
!
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR
END FOR SERVICE.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 5.
FOR G & F DIMENSIONS SEE TABLE 1 ON PAGE 5.
NOTE:
FRONT EDGE
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
AMERICAN STANDARD
APRON KIT
The rim of the bath must not support weight. If foundation base is used, allow the
bedding material to completely harden before applying weight to the rim or bottom of
the bath. Any finish material such as tile or wall board must be self-supporting if it
contacts the deck of the bath.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
(EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
10
753737-100 Rev. B
SUGGESTED WHIRLPOOL / BATH
INSTALLATION METHOD
SECURE THE BATH TO THE STUDS AS SHOWN
FOR WOOD OR STEEL STUD CONSTRUCTION.
TYPICAL FLANGE MOUNTING DETAIL
UNLESS AN ACCESS OPENING OF AT LEAST
12" x 24" (305 x 610mm) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
1-1/
(5mm)
WHIRLPOOL
ACCESS PANEL
Please note that care must be taken to protect the surface of the tub during all aspects of the installation.
Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
1. Install the tub per the installation instructions provided with the unit.
. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.
3. Cut bath deck to your specifications.
. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath
deck with the tub directly beneath it as damage to the tub may result.
5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.
. Replace the bath deck and secure it into place.
7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.
. Remove excess sealant per the manufacturer's instructions.
Finished bath deck surface material must be
self-supporting and secured per local codes
Tub support structure per installation
instructions provided with the tub
Bath deck support material
Bathtub
Waterproof
Sealant
* SEE CUTOUT TEMPLATE
PROVIDED ON UNDERSIDE
OF BOX LID
UNDER DECK MOUNTING INSTRUCTIONS
STUD
WATERPROOF DRYWALL
OR CEMENT BOARD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
SEALANT
TUB
ROOFING NAIL
1 x 3 (5 x 7mm) WOOD
STRINGER FULL LENGTH
1 x 3 (5 x 7mm) WOOD
STRINGER FULL LENGTH
STEEL
STUD
WASHER
TILE
SEALANT
TUB
" (10mm)
DRYWALL
SCREW
WOOD
STUDS
STEEL
STUDS
TYPICAL INSTALLATION -
CORNER
753737-100 Rev. B
11
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
. All building materials and wiring should be routed away from the pump body and heater (if equipped).
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BLACK
WHITE
120 VA C
GND .
PUMP/MOTOR
WIRE S ELECTI ON GUI DE
Maximu m dist ance f rom
fusebo x to m otor
The si zes sh own on this
chart are re commen dation s
for co pper c onduct ors
only. Alway s foll ow
local and na tional
electr ical c odes
Motor
Hi Per forman ce
Rating
2.1 H. P.,
1.4 H. P.,
and 1. 25 H.P .
50' 100'
115V P ower L ine
150' 200 '
12 10 8 8
!
The whirlpool should be installed on a 120 vac,
15
amp dedicated
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
The whirlpool should be installed on a 120 vac, 20 amp dedicated
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
GFCI CIRCUIT REQUIREMENTS: FOR MODEL NUMBERS:
2732, 2422, 2425, 2645,
2771, 2805, 2908
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
LA, LAC, VA, VAC
6060, 2775, 2773, 2711, 2901
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
L, LC, V, VC
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
1
753737-100 Rev. B
For 6060L/V Corner Only
OPERATION
ELECTRICAL CONNECTIONS
Install a separate 10VAC / 15AMP dedicated circuit with GFCI (Ground Fault Circuit Interrupter) protection.
At initial start-up with power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset. If the GFCI fails to
operate in this manner, there is a ground fault or malfunction, indicating the possibility of electrical shock. Turn off the power and do not
use the bath until the source of the problem has been identified and corrected.
1. Route two separate branch circuits to the junction box near the whirlpool as shown in Figure . Each branch circuit MUST BE GFCI
PROTECTED and must use copper conductors only.
. Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the  AWG solid copper conductor supplied with
the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. The conductor is secured to the lugs using set
screws. The motor frame shall have a second  AWG solid copper conductor connected from the frame bonding lug to the homes electrical
panel or approved local bonding point as shown in Figure 3.
Fig. 2 Fig. 3
Fig. 1
WARNING: Prior to operation, review the Important Safety Instructions
listed at the beginning of this instruction manual.
Once the heater is installed and the whirlpool pump is operating, the heater is
totally automatic. The heater will help maintain the temperature of the water in
the bath.
Pressure Switch
The heater is equipped with a preset pressure switch. The pump must be
running with water flowing in the whirlpool to allow the heater to turn on.
Indicator Light
This light turns on whenever the heater is operating.
High-Limit Switch
The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater
off if the thermostat fails. If the high-limit trips frequently, call a service technician.
To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. () Drain
water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. () The heater circuit will
automatically reset in less than 15 minutes. (5) Restore power to the heater. () Whirlpool bath is now ready to use.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BL AC K
WH IT E
12 0 VA C
GN D.
SEPARATE 20 AMP GFCI OUTLET
for2.1 H.P. PUMP
SEPARATE 15 AMP GFCI OUTLET
for 1.6 H.P. PUMP
PUMP/MOTOR
ELECTRICAL INSTALLATION
HEATER
BL AC K
WH IT E
12 0 VA C
GN D.
SEPARATE
15 AMP GFCI OUTLET
HEATER “ON” LIGHT
Bonding Lug on
Heater Housing
E-Z INST
AL
L
WHIRLPOOL
HEA
TE
R
RUN  AWG SOLID COPPER
CONDUCTORS FROM
HEATER BONDING LUG TO
PUMP/MOTOR FRAME LUG
AND FROM PUMP/MOTOR
LUG TO APPROVED
GROUND AS SHOWN
(PUMP/MOTOR)
TO GROUND
SECOND
COPPER
CONDUCTOR
FIRST COPPER
CONDUCTOR
PUMP/MOTOR FRAME WITH
BONDING LUGS
HEATER ON
E-
Z
IN
S
TA
L
L
W
H
IR
L
P
O
O
L
HE
AT
ER
FACTORY INSTALLED - NOT FOR RESALE
HEATER P/N: 753174-100
(HEATER)
753737-100 Rev. B
13
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions.
Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with
water to a point " above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking.
(Although the pump couplings are factory tightened and inspected, some loosening may have occurred during transit.) Make sure
the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use
wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains
may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
AFTERCARE and CLEANING
The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and
maintenance.
Always fill the tub with temperate water. Excessively hot water may cause surface damage
Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray or
concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner, or
cleaning products in aerosol cans.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other surface blemishes.
Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses
its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and
waxing with a "liquid wax."
Do not wax areas where you walk or stand.
Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into
contact with the surface.
Clean the surrounding surface immediately after using caustic drain cleaners.
Burning cigarettes will damage the surface.
Should damage to the fixture occur, repairs can be made quickly and easily.
Your distributor or builder can provide details.
Do not permit drain cleaner to enter the circulation system.
CIRCULATION SYSTEM CLEANING-PURGING PROCEDURES
STEP 1. Once every month purge and clean the circulating system. Fill whirlpool with warm water and add two teaspoons
of dishwasher detergent and one-half cup of house hold bleach.
STEP 2. Activate whirlpool system in accordance with operating instructions or two minutes.
STEP 3. Drain and refill whirlpool with cool water and circulate for additional five minutes.
STEP 4. Drain whirlpool completely.
1
753737-100 Rev. B
B
y Mail: American Standard Inc.
P.O. Box 5
West Caldwell, N.J. 07007
Attention: Customer Care Center
American Standard Limited Lifetime Warranty for Lifetime™ / Evolution™ Acrylic Whirlpools
American Standard warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are
found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original
consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof
of purchase.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE
INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of repair or replacement of any installation materials
including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper maintenance and cleaning as directed
in the owner’s manual and use of other than genuine American Standard replacement parts, in all cases whether caused by a plumbing contractor,
service company, the owner or any other person.
. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
. Options and accessories. American Standard’s limited warranty on these items is one year for parts only and excludes labor. This one year limited
warranty covers accessories manufactured by American Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against defects of material or
workmanship. Warranty coverage begins on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in
connection with product removal or installation under this limited warranty.
. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED, OR THE
EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF
MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an implied warranty
lasts, or the exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly distributors, retailers, dealers, installation
contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product.)
This warranty gives you specific legal rights. You may have other legal rights that vary from state to state. For service under this warranty, you should
contact the following:
By Telephone:
1-800-442-1902
American Standard Limited Five (5) Year Warranty for the Renaissance Whirlpools
American Standard warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found
by American Standard, in its sole judgment, to be defective under normal residential use and maintenance for a period of five (5) years from date of
purchase so long as it is owned by the original consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof of
purchase.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE
INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of repair or replacement of any installation materials
including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper maintenance and cleaning as directed in
the owner’s manual and use of other than genuine American Standard replacement parts, in all cases whether caused by a plumbing contractor, service
company, the owner or any other person.
. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
. Options and accessories. American Standard’s limited warranty on these items is one year for parts only and excludes labor. This one year limited
warranty covers accessories manufactured by American Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against defects of material or
workmanship. Warranty coverage begins on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection
with product removal or installation under this limited warranty.
. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED, OR THE
EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF
MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an implied warranty lasts,
or the exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly distributors, retailers, dealers, installation
contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product.)
This warranty gives you specific legal rights. You may have other legal rights that vary from state to state.
For service under this warrant you should contact the following:
In the United States:
American Standard Inc.
P.O. Box 5
West Caldwell, New Jersey 07007
Attention: Director of Consumer Affairs
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (00) -10
www.americanstandard-us.com
In Canada:
American Standard
0 Stanfield Rd.
Mississauga, Ontario
Canada LY 1S
Toll Free: (00) 37-03
www.americanstandard.ca
In Mexico:
Customer Service Manager
Ideal Standard, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 5550 Edo. Mexico
www.americanstandard.com.mx
753737-100 Rev. B
15
If inspection of this American Standard plumbing product, within one year after its initial purchase, confirms that it is defective in materials or
workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This warranty applies only to the original purchaser and installation of these products.
This limited warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser of this
product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance,
abuse, misuse, accident or other damages; if it was not installed in accordance with American Standard's instructions; or if it has been modified in a
manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or
installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect
or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not
allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in
which case this warranty does not affect such statutory rights.
For service under these warranties, it is suggested that a claim be made through the contractor or dealer from or through whom the product was
purchased, or that a service request (including a description of the product model and of the defect) be sent to:
AMERICAN STANDARD ONE YEAR LIMITED WARRANTY
FOR E-Z INSTALL WHIRLPOOL HEATER
Product names listed herein are trademarks of American Standard Inc.
American Standard Inc. 007
C
HOTLINE FOR HELP
For toll-free information and answers to your questions, call 1 (800) 442-1902
weekdays: :00 a.m. to 5:00 p.m. Eastern Time
SERVICE: For service or repair contact the number below. The model number and
serial number for your whirlpool are located on a label near the motor.
By Mail: American Standard Inc.
P.O. Box 5
West Caldwell, N.J. 07007
Attention: Customer Care Center
By Telephone:
1-800-442-1902
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

American Standard 2645VA User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI