1. Prior to Installation:
• Remove protective plastic and packaging and carefully inspect for any
damage.
• Check tub for correct model name, size, color and trim nish.
• The tub MUST be tested while pump, electrical systems, and piping
(plumbing) are accessible.
• If there are any issues, do not install and report the issues immediately
to our factory or the authorized dealer.
2. WARNING: To avoid injury, exercise caution when entering or exiting the
bathtub.
3. DANGER/WARNING: To reduce the risk of injury, do not permit children or
persons with a disability to use this unit unless they are closely supervised
at all times. Risk of accidental injury or drowning. Children should not use
hydromassage bathtub without adult supervision.
4. WARNING: Risk of accidental injury or drowning; Do not use hydromassage
bathtub unless all suction guards are installed to prevent body and hair
entrapment.
5. This product is for indoor use only. Use the bathtub only for its intended
purpose as described in this manual and do not use attachments or accessories
which are not recommended by manufacturer.
6. Never drop or insert any objects into any openings.
7. Persons with long hair should wear a bathing cap when using the bathtub.
8. WARNING: Risk of accidental injury or drowning; do not use drugs or alcohol
before or during the use of a bathtub or hydromassage bathtub equipped
with heater to avoid unconsciousness or possible drowning.
9. WARNING: Risk of Fetal Injury; pregnant or possibly pregnant women should
consult a physician before using a hydromassage bathtub equipped with
heater.
10. The bathtub must be connected to an electrical supply circuit that is
protected by a ground fault circuit interrupter (GFCI) which is provided
by the installer. The GFCI should be tested periodically to ensure that it is
working properly.
11. Keep all appliances, such as radios and hair dryers, a safe distance from the
bathtub.
12. For permanently connected units, green colored terminal (or a wire connector
marked “G”, “GR”, “Ground”, or “Grounding”) is provided within the terminal
compartment. To reduce the risk of electrical shock, connect this terminal or
connector to the grounding terminal of your electrical service or supply panel
with a conductor equivalent in size to the circuit conductors supplying this
equipment.
13. Install in accordance with manufacturers installation instructions. Failure
to comply with all instructions, requirements and warnings contained in this
manual creates a serious hazard to the bathtub user and may result in serious
personal injury.
Warning: The causes, symptoms, and eects of hyperthermia may be described
as follows: Hyperthermia occurs when the internal temperature of the body
reaches a level several degrees above the normal body temperature of 98.6. The
symptoms of hyperthermia include an increase in the internal temperature of the
body, dizziness, lethargy, drowsiness, and fainting. The eects of hyperthermia
include (1) failure to perceive heat, (2) failure to recognize the need to exit
the spa or hot tub, (3) unawareness of impending hazard, (4) fetal damage
to pregnant women, (5) physical inability to exit the spa or hot tub, and (6)
unconsciousness resulting in the danger of drowning.
Warning: The use of alcohol, drugs, or medication can greatly increase the risk
of fatal hyperthermia.
SAVE THESE INSTRUCTIONS
Americh baths are assembled complete and ready for installation.
Immediately upon receiving the bath and removal of packing, INSPECT
the unit for freight damage. Any claims for damage, whether apparent
or hidden, must be made to freight carrier immediately, in order for them
to assume all associated costs. Should inspection reveal any defect in the
nish, DO NOT INSTALL THE BATH. Damage or defect to the nish claimed
after the bath is installed is excluded from the warranty. The warranty DOES
NOT cover labor or materials to remove or re-install the bath.
PRIOR TO INSTALLATION
Check to ensure that:
1. The installation will conform with all applicable Federal, State and Local
Building Codes & Regulations;
2. The unit is the correct model and color;
3. There has been no shipping damage;
4. The “notice or warning” tags on the bathtub have been read and thoroughly
understood;
5. The interior of the tub will be protected during installation;
6. Make sure sub oor is level.
DURING INSTALLATION
Check to ensure that:
1. Bathtub is not hanging from the rim. Bath must be supported from the oor
(See Figure 1, Page 4.)
2. An access panel with minimum dimensions of 16” height by 20” width is
required. See specication sheet for proper access panel location.
3. All Bathtubs with seats must have additional support for each seat.
4. All building materials and wiring should be routed away from the pump body
or other heat producing components of the unit.
ELECTRICAL REQUIREMENTS
Manufacturer recommends a dedicated 20 amp circuit breaker for each power
cord supplied on your whirlpool bathtub. WARNING - When using electrical
products, basic precautions should always be followed, including the following:
1. DANGER: Risk of electric shock. Connect only to a supply circuit protected
by a Class A ground-fault circuit-interrupter (GFCI). Test on a routine basis.
2. Grounding is required. The unit should be installed by a qualied service
representative and grounded.
3. (For built-in and custom units) install to permit access for servicing.
4. Supply 110 Volt electrical outlet. This circuit must be protected by a ground
fault circuit interrupter (GFCI.)
5. Plug supply cord(s) into electrical outlet.
6. To test the GFCI, do the following:
a. Push the test button;
b. Check to see that power has been interrupted;
c. Push the reset button;
d. Check to see that power has been restored.
If the GFCI does not operate properly during the test, there is a ground current
owing indicating the risk of electric shock. Do not use this unit. Disconnect the
unit and have the problem corrected by a qualied service representative before
using.
Refer to Operating Instructions for system operations and wiring diagrams.
Warning: Whirlpool bathtubs utilize acrylic and fiberglass materials (which are inherently slippery surfaces), electricity, water, air pressure and suction. The
following basic safety precautions should always be followed when using your bathtub.
CAREFULLY
READ AND FOLLOW ALL INSTRUCTIONS
before attempting to operate your whirlpool or Airbath® Bathtub.
IMPORTANT SAFETY INSTRUCTIONS:
pertaining to a risk of re, electric shock, or injury to persons
03
installation instructions
PREPARE SETTING BED
1. Prepare tub setting bed using lightweight cement, plaster, gypsum or x-all
bed approximately 1” or 2” thick (gure 1).
2. Place the tub in the proper position using the oor, not the deck or rim, as
the support, and set it in the bedding compound (gure 2).
COMPLETE BATH INSTALLATION
Level the top of the bathtub in both directions, using a 4 ft. level, to ensure
drainage. Bring the tile or nished surface to tub deck and then seal. Seal
edges as shown (See Figures 3, 4 or 5.)
CLEAN-UP AFTER INSTALLATION
When cleaning up after installation, do not use abrasive cleaners as they
may scratch and dull the surface. Use warm water and a liquid non-abrasive
detergent to clean the surface.
Stubborn stains, paint or tar can be removed with turpentine or paint
thinner. Do not allow cleaners containing petroleum distillates to remain in
contact with bath surface for long periods of time. Plaster can be removed by
scraping with a wood edge. Do not use metal scrapers, wire brushes, or other
metal tools.
TESTING OPERATIONS
To check proper function of your newly installed bathtub take the
following steps:
1. Remove all debris and residue before lling the tub with water
2. Fill the tub with water until the highest whirlpool jet is covered by at least
2” of water.
3. Examine tub and system carefully for leaks.
4. Turn on system and allow tub to run approximately 2-3 minutes
(Whirlpool only).
5. Allow water to sit for 10 minutes and check for leaks.
6. Open drain and empty tub.
7. Wipe up excess water with a soft, damp sponge.
When cleaning up after installation do not use abrasive cleaners, steel wool,
scouring pads or harsh chemicals. For cleaning procedures refer to the “Care
and Maintenance section.
gure 1
Choose the installation option that applies to your particular installation and follow the instructions. Be sure to take any necessary precautions to keep tub
protected during installation.
gure 2
gure 5
gure 4
gure 3
TECHNICAL SERVICE
For technical service or eld service, you must:
1. Locate the product identication tag. This tag includes all pertinent
information specic to your product, including the model, size, color, date
of manufacture and ID number.
2. Write down all information and have it available when contacting the
manufacturer.
The manufacturer maintains strict guidelines for eld service and will require
this information in order to facilitate your request and determine if a eld
service representative is required.
Warning: Any service should be performed by a qualied licensed service
agent.
CARE AND MAINTENANCE
Soap residues and mineral deposits are the enemies of your bathtub, particularly in areas where there is hard water. However, cleaning your bathtub at regular intervals
and using proper cleaning agents, you can help your bathtub retain its original sparkling look. DO NOT USE abrasive cleaners, as these products will damage the
bathtub surface and metallic nishes. A non-abrasive cleaner is recommended.
Your bathtub does not require the use of special cleaning agents or chemicals.
Normal cleaning is simple and easy.
operating instructions
04
1 Engages the system with jets on HIGH
2 Engages the system with the jets on LOW
3 Engages the system and pulsates the water ow
4 OFF Button Turns the jets OFF
1 2 3 4
5
5 LIGHT Button used to control the optional mood light.
• Pressthe“Lightbuttontoturnonthemoodlight
• Thelightdisplays7vividcolorsand2sequencingsettings.
Tochangethelightcolor,pressthe“Lightbuttontoturnitoandafteronesecondpressitagaintoturniton.
• Thecolorsequenceisasfollows:BrightWhite,AquaBlue,SoothingBlue,OceanBlue,MajesticGold,ShamrockGreen,FieryRed,ChameleonMode,Party
Mode
• Intheeventthatthelightisleftturnedon,itwillautomaticallyturnoafter2hourscontinuousoperation.
1. Preparation and Cleaning
• Drain the bathing well of all water.
• Rotate the jet assembly to remove from jet case.
• Disassemble the jet assemblies (3 pieces each) and place them in the sink. Use a non-abrasive antibacterial cleaner to
remove any visible residue - rinse with fresh water.
• Use a non-abrasive antibacterial cleaner to clean the bathing vessel, jet cases, drain stopper and overow mechanism–
rinse with fresh water.
2. Disinfection
• Spray the surface area of the jet assemblies and bathing vessel until thoroughly coated with a registered disinfectant.
• Allow to set for the required disinfection contact period (refer to manufacturers specications) then rinse surfaces with
fresh water.
3. Reassembly
• Dry the jet assemblies and bathing vessel.
• Reassemble and replace jets by aligning the 11 oclock
To preserve the surface nish, annual waxing is recommended. Use a high-grade paste-type automotive wax.
©01/14
WHISPER COLLECTION
Residential Limited Warranty
Americh Corp. warrants that its bathtubs are free of defects in manufacture and materials so long as (1) the bathtub is installed and maintained according to Americh Corp.
recommended installation and maintenance procedures, (2) use of the bathtub is limited to personal, family or household purposes and (3) any defects are not the result
of unauthorized or unreasonable use.
This warranty applies only to the rst consumer purchaser and is limited in time from the date of original purchase for a period of ve (5) years with respect to the tub and
twelve (12) months with respect to the electronics and accessories. This warranty does not apply to subsequent owners, transferees or users.
This warranty does not apply to or cover defects, damage or failure caused by the freight carrier, installer, user or other person, or resulting from, without limitation, any
of the following: improper handling, modication of any type, improper installation, misuse, incorrect operation, lack of proper routine maintenance, the use of improper
cleaners or abrasives, accidents or acts of God. Nor does it apply to eects of normal wear and tear.
Alteration, customization or modication of the tub, the water system, the electronics, any accessory or any other part voids this warranty.
If a defect or malfunction is discovered during normal residential use notify Americh Corp. in writing within ten (10) days of discovery, setting forth the date of discovery,
a description of the defect or malfunction, the name and address of the installer of the bathtub, electronics and accessories and the date and address of installation and
the type or style of the bathtub. Americh Corp., will, at its election, repair, replace or make appropriate adjustments. In all cases a reasonable time must be allowed for
commencement and completion of warranty repairs.
Americh Corp. is not responsible for labor charges or other charges related to the removal or installation or other costs involved in repairing or replacing the bathtub or the
expense of shipment to or from the factory, except where provided by applicable law.
To obtain information about or performance of warranty obligations contact Americh Corp. 13212 Saticoy Street, North Hollywood, CA 91605 or by calling (818) 982-1711
and asking for Customer Service.
No other company or person has any authority to make any warranties or representations concerning Americh Corp. or the product. Accordingly, Americh Corp. is not
responsible for any such warranties or representations.
THIS LIMITED WARRANTY IS THE SOLE WARRANTY FOR YOUR AMERICH CORP. PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
AMERICH CORP. HAS NOT MADE AND DOES NOT MAKE ANY WARRANTY OR REPRESENTATION, WHATSOEVER, EXPRESS OR IMPLIED, ABOUT THE CONDITION, MERCHANTABILITY, DESIGN, OR OPERATION OF THE
BATHTUB OR ITS FITNESS FOR ANY PARTICULAR USE OR PURPOSE, OR THE QUALITY OF THE MATERIALS OR WORKMANSHIP IN THE BATHTUB, THE ELECTRONICS OR THE ACCESSORIES OR ANY OTHER REPRESENTATION
OR WARRANTY BEYOND THE TERMS OF THIS LIMITED WARRANTY.
AMERICH CORP. DISCLAIMS AND SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION, IN WHOLE OR IN PART, OF WARRANTIES OR THE EXCLUSION OF SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES. THEREFORE, THE ABOVE
LIMITATIONS OR EXCLUSIONS MAY NOT BE APPLICABLE TO YOU.
West Coast
13212 Saticoy Street
N. Hollywood, CA 91605
818.982.1711 Tel
818.982.2764 Fax
East Coast
10700 John Price Road
Charlotte, NC 28273
704.588.3075 Tel
704.588.3166 Fax
800.453.1463
www.americh.com
Standard for Hydromassage
Bathtubs, UL 1795
Standard for Hydromassage
Bathtub Appliances CSA C22.2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

AMERICH Whisper Collection User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI