Stabila 196 electronic IP65 Operating Instructions Manual

Type
Operating Instructions Manual

Stabila 196 electronic IP65

The Stabila 196 electronic IP65 is an electronic spirit level with 2 digital displays for quickly and easily measuring inclinations and angles.

Some of its features include:

  • vertical and horizontal vials for leveling in any position
  • electronic module with 2 digital displays
  • IP 65 water and dust resistant
  • automatic display inversion for overhead measurements
  • alignment guides to help with leveling
  • various measurement modes, including degrees, percent, and millimeters per meter
  • reference angle function to set a custom zero point
  • lighting for working in low-light conditions

Stabila 196 electronic IP65

The Stabila 196 electronic IP65 is an electronic spirit level with 2 digital displays for quickly and easily measuring inclinations and angles.

Some of its features include:

  • vertical and horizontal vials for leveling in any position
  • electronic module with 2 digital displays
  • IP 65 water and dust resistant
  • automatic display inversion for overhead measurements
  • alignment guides to help with leveling
  • various measurement modes, including degrees, percent, and millimeters per meter
  • reference angle function to set a custom zero point
  • lighting for working in low-light conditions
Operating Instructions196 electronic IP65
196 M electronic IP65
EN
196 / 196 M electronic IP65
1
en
The STABILA 196 electronic IP65 is an electronic spirit level
with 2 digital displays for quickly and easily measuring
inclinations and angles.
If you still have any questions aer reading the
operating instructions, feel free to call our hotline:
0049 / 63 46 / 3 09 - 0
Equipment and functions:
• vertical vial(s) for vertical levelling, in reverse position too
• horizontal vial for horizontal levelling, in reverse position too
• electronic module with 2 digital displays for accurately
determining inclinations and angles
Operating Instructions
196 / 196 M electronic IP65
2
en
Components of the unit
Buttons:
On/Off
Operating mode selection
Reference
Measurement memory
Lighting
Acoustic signal
Calibration
Button lock
1. 2 Displays
2. Battery compartment lid
3. Magnet (196 M electronic IP65)
4. Vials - vertical and horizontal
5. Removable, shock-absorbing end caps
6. Anti-slip stopper
7. Electronic module
- dust-proof and waterproof in accordance with IP 65
IP 65
IP 65
196 / 196 M electronic IP65
3
en
2x 1.5V
alkaline
AA, LR6, Mignon
MN 1500
Unscrew battery compartment lid on rear, insert new
batteries according to symbol in battery compartment.
Suitable rechargeable batteries can also be used.
LCD:
low battery charge - insert new battery
Dispose of used batteries at suitable collection
points - not with household waste.
Do not leave in unit!
Remove the batteries if you do not intend
to use the unit for some time!
Insert batteries / Battery replacement
196 / 196 M electronic IP65
4
en
After switching on, an automatic self-test is carried out.
All the display's segments are shown.
After the end of the test, the version number S x.xx of the
measurement program is briefly displayed and the saved
automatic switch-off time of 1/8 or 2 hours displayed.
An acoustic signal indicates that the unit is ready for
operation.
The display shows the angle measured in the set unit
of measurement.
Commissioning
test
off
Software Version
196 / 196 M electronic IP65
5
en
Automatic display inversion
The two displays are inverted for overhead measurements
so they are always legible.
Alignment guides
Arrows in the display show which way to turn the
spirit level to the horizontal (-15°/0 °/+ 15°) or
vertical (+75°/90°/-75°).
The acoustic alignment guide is activated /
deactivated using the "Acoustic signal" button.
If the acoustic signal is activated, the tone
sequence speeds up as the 0° or 90° position is
approached in a range of ± 2° to the horizontal
or vertical. A change in the pitch indicates that
these positions have been exceeded.
A continuous tone confirms the precise point
at which the horizontal / vertical is reached.
This is also indicated on the display with 2
"centre display" bars.
The electronic spirit level can also be aligned using the vial.
196 / 196 M electronic IP65
6
en
0,05˚
0,1˚
The unit of measurement is set by pressing
the MODE button several times.
° Rough: Display in 0.1° steps
° Fine: Display in 0.05° steps
%: Display in 0.1 % steps
mm/m: Display in 1 mm/m steps
in/ft decimal: Display in 0.01 in/ft steps
in/ft fraction: Display in 1/8 in/ft steps
The set unit of measurement is retained after the unit is
switched off.
Setting the unit of measurement
MODE
196 / 196 M electronic IP65
7
en
The REF button can be used to select any set angle as
0° reference. The angle details now displayed relate to
this reference angle. The display flashes in this setting.
The original reference angle value is displayed for 2 seconds
by briefly pressing the REF button.
The reference angle is deleted by:
• Pressing and holding (≥ 3 sec) the REF button
If the button lock is active, this must be disabled first.
• Switching off
• The automatic switch-off function
The zero position again refers to the calibrated setting.
The alignment selected for the electronic spirit level must
not be changed during the reference function!
Reference angle
- freely selectable zero position
+5°
(= 25° )
(= 20° )
20°
( + 5° )
RESET
REFERENCE
REFERENCE
20°
3 sec
1x
1x
1x
3 sec
2 sec
196 / 196 M electronic IP65
8
en
Briefly pressing the "Lighting" button switches the display
lighting on for approx. 60 seconds.
Pressing and holding the "Lighting" button switches the
lighting permanently on or off.
The pressing of this button is confirmed by an acoustic signal.
Lighting
1x
1x
1x
on = 60 sec
on =
Button lock
Pressing and holding ( ≥ 3 sec ) the "Key" button locks the
Operating mode selection
Reference
Measurement memory
Calibration
buttons. The button lock remains active after switching the
unit off and back on again!
Pressing and holding the "Key" button disables the button
lock. The pressing of this button is confirmed by an acoustic
signal.
1x
1x
5 sec
196 / 196 M electronic IP65
9
en
1x
1x
HOLD
Measurement memory
The current measurement can be saved by pressing the
HOLD button. The arrows and the "centre display" bars
flash. The measurement is displayed continuously.
Close to 0° and 90° the arrows flash to indicate direction.
The saved measurement is deleted by again pressing the
HOLD button or switching the unit off.
196 / 196 M electronic IP65
10
en
Setting switch-off time
The electronic spirit level is switched off automatically if
not used or moved for a long while. Pressing the "Lighting"
and "Acoustic signal" buttons at the same time allows the
automatic switch-off time to be changed from 1/8 hours
(approx. 7.5 minutes) to 2 hours. The set switch-off time
is retained after the unit is switched off and is displayed
briefly when it is switched on again.
8
1
h
= 7.5 min
2h
2
1
1x
1x
Acoustic signal
The acoustic alignment guide is activated / deactivated
using the "Acoustic signal" button.
196 / 196 M electronic IP65
11
en
Tilt function
The measuring surfaces of the electronic spirit level should
be positioned precisely for all measurement work.
If positioned at too great an angle, the tilt function prevents
incorrect measurements. The display doesn't then show any
measurements.
196 / 196 M electronic IP65
12
en
0° - 0.05° = OK
> 0.05° CAL.
Accuracy check
To prevent incorrect measurements, before starting work
or after hard knocks, large changes in temperature and
a change of user, the accuracy must always be checked.
1. Switch on the electronic spirit level. Use the vial to
accurately align the unit to a wall, for example, until
the vial bubble is in the middle between the vial rings.
2. Wait 10 seconds. If the value displayed is > 0.05°,
the electronic spirit level must be recalibrated.
If mainly used for vertical measurements, the accuracy
check can also be undertaken with the vertical vial.
10 sec
196 / 196 M electronic IP65
13
en
Calibration
1. Switch on the electronic spirit level. Use the vial to
accurately align the unit to a wall, for example, until
the vial bubble is in the middle between the vial rings.
If mainly used for vertical measurements, the calibration
can also be undertaken with the vertical vial.
2. Hold the electronic spirit level in this position and
press the CAL button.
The CAL display shows calibration mode.
3. Calibration starts when the CAL button is pressed again.
CALIBRATE
1x
1x
1x
Newly calibrated value with
deviation of ≥ 1° from
factory setting
Recalibrate spirit level
Vibration during
calibration
Recalibrate spirit level
Calibration completed
successfully
Spirit level ready
The reverse test checks the calibration.
Angle ≤ 0.1° to normal
position
Spirit level ready
1x
5 sec
180°
196 / 196 M electronic IP65
14
en
Calibration in 4 positions:
Calibration in 4 positions is needed if the following is
displayed:
1. The reverse test angle is ≥ 0.1° to the normal position
--> too great a deviation.
2. Change in internal reference
3. Change in temperature since last calibration.
The electronic spirit level is calibrated in 4 measuring positions
consecutively, turning 90° / 180° each time.
Calibration in 4 positions: Step 1
Press CAL and MODE buttons at the same time. Align the
electronic spirit level accurately against a wall and press
the CAL button to confirm.
Only the 1st calibration step is performed with the
vial.
1x
Flashing segments indicate the positions still to be calibrated.
Non-flashing segments indicate the positions already
calibrated.
196 / 196 M electronic IP65
15
en
180°
1x
Calibration in 4 positions: Step 2
The electronic spirit level is turned 180° and aligned using
the arrows displayed.
The electronic spirit level is aligned horizontally using the
arrows displayed.
The 2 "centre display" bars indicate the precise position at
which the horizontal is reached.
Confirm with the CAL button.
Flashing segments indicate the positions still to be calibrated.
Non-flashing segments indicate the positions already
calibrated.
196 / 196 M electronic IP65
16
en
1x
90°
Calibration in 4 positions: Step 3
The electronic spirit level is turned 90° and aligned vertically
using the arrows displayed.
The 2 "centre display" bars indicate the precise position at
which the vertical is reached. Confirm with the CAL button.
The flashing segment indicates the position still to be
calibrated.
Non-flashing segments indicate the positions already
calibrated.
196 / 196 M electronic IP65
17
en
1x
180°
Calibration in 4 positions: Step 4
The electronic spirit level is turned 180° and aligned vertically
using the arrows displayed.
The 2 "centre display" bars indicate the precise position at
which the vertical is reached. Confirm with the CAL button.
"rdy" display:
Calibration in 4 positions successfully completed!
196 / 196 M electronic IP65
18
en
Maintenance and upkeep
The electronic spirit level is a precision instrument and should therefore be
handled with care.
Display window:
Dirty window glass impairs the optical function.
Only clean with a soft cloth, a little water or, if required, a mild detergent!
Casing:
Clean the unit with a damp cloth.
• Do not use solvents or thinners!
• Do not immerse the unit in water
• Do not unscrew the electronic spirit level!
Transport and storage
• Remove the batteries if you do not intend to use the unit for some time!
• Do not store the unit when damp!
• Allow the unit and carry case to dry first if
necessary.
Recycling programme for our EU customers
In accordance with WEEE rules, STABILA oers to dispose of electronic products
at the end of their useful service life.
For more information call: 0049 / 6346 / 309-0
STABILA warranty declaration
In addition to the statutory rights of buyers, which are not limited by this
warranty, STABILA guarantees that the unit is free from defects and has
assured features in the event of material or manufacturing defects for a
period of 24 months from the date of purchase. Any defects / errors will
be remedied at our discretion through reworking or replacement.
STABILA will not assume liability for further claims. Defects resulting
from improper handling (e.g. damage due to application of serious force,
operation with incorrect voltage / current type, use of unsuitable power
source) and unauthorised modifications to the unit by the buyer or a third
party shall invalidate the warranty.
STABILA does not provide a warranty for natural signs of wear and minor
defects that do not affect the operation of the unit. Any warranty claims
should be made through your dealer and be accompanied by your sales
receipt, completed certificate of warranty (see last page of operating
instructions) and the unit itself.
Certicate of warranty for 196 / 196 M electronic IP65
Customer:
Address:
Date of purchase:
Dealer (stamp, signature):
Technical data
Accuracy:
Electronic module
0° + 90° : ± 0.05°
1° .... 89° : ± 0.2°
Spirit level
in normal position: 0.5 mm / m = 0.029°
in reverse position: 0.5 mm / m = 0.029°
Batteries : 2 x 1.5 V alkaline, size Mignon, AA, LR6
Operating life : ≥ 150 hours
Operating temperature range: -10 °C to +50 °C
Storage temperature range: -20 °C to +65 °C
Protection class: IP 65
Subject to technical modifications. 2015
STABILA Messgeräte
Gustav Ullrich GmbH
P.O. Box 13 40 / D-76851 Annweiler
Landauer Str. 45 / D-76855 Annweiler
Tel.: + 49 63 46 309 - 0
Fax: + 49 63 46 309 - 480
E-mail: info@stabila.de
www.stabila.de
STABILA Inc.
332 Industrial Drive
South Elgin , IL 60177
1.800.869.7460
www.stabila.com
USA
Canada
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Stabila 196 electronic IP65 Operating Instructions Manual

Type
Operating Instructions Manual

Stabila 196 electronic IP65

The Stabila 196 electronic IP65 is an electronic spirit level with 2 digital displays for quickly and easily measuring inclinations and angles.

Some of its features include:

  • vertical and horizontal vials for leveling in any position
  • electronic module with 2 digital displays
  • IP 65 water and dust resistant
  • automatic display inversion for overhead measurements
  • alignment guides to help with leveling
  • various measurement modes, including degrees, percent, and millimeters per meter
  • reference angle function to set a custom zero point
  • lighting for working in low-light conditions