Charlotte Pipe PVC 00304 1200 User guide

Type
User guide
DIMENSIONAL CATALOG
DWV
© 1977-2020 Charlotte Pipe and Foundry Company
DC-DWV
ConnecTite® Push-Fit DWV
Fittings
ABS-DWV Pipe and Fittings
PVC-DWV Pipe and Fittings
PVC Sewer Pipe
PVC Schedule 30 DWV Thin
Wall 3.25 in. O.D. Pipe and
Fittings
(Updated July 14, 2020)
Plastic DWV Pipe and Fitting Dimensions
All products manufactured by Charlotte Pipe and
Foundry Company are proudly made in the U.S.A.
This catalog accurately reflects dimensional information to the best
of our knowledge. If the dimensions on your job are critical, please
verify dimensional information with our factory.
This dimensional catalog accurately reflects our product line at the
time the catalog was printed. However, we add and delete items on
an ongoing basis to better serve our customers. Please refer to our
current list price sheets for an accurate listing of items offered.
Charlotte Pipe® products are manufactured to the applicable ASTM
standard. Charlotte Pipe and Foundry cannot accept responsibility
for the performance, dimensional accuracy, or compatibility of pipe,
fittings, gaskets, or couplings not manufactured or sold by Charlotte
Pipe and Foundry.
Page
ABS “Foam Core” Schedule 40 DWV
Pipe Data ..................................................4
ABS Plus® “Foam Core” Schedule 40 DWV
Pipe Data ..................................................5
PVC “Foam Core” Schedule 40 DWV
Pipe Data ..................................................6
PVC Schedule 40 DWV Pipe Data ......................7
D 3034 PVC Sewer Pipe Data ............................8
PVC D 2729 Sewer and Drain Pipe Data ............. 9
ConnecTite® Push-Fit DWV Fittings .............10-11
PVC and ABS DWV Fittings Dimensions ......12-66
PVC Thin Wall Sch. 30 Pipe Data .....................67
PVC Thin Wall Sch. 30 Fittings
Dimensions .........................................68-74
Certification ................................................75-76
Warranty .........................................................77
Table of Contents
Charlotte Pipe, ABS Plus and ConnecTite are registered trademarks of
Charlotte Pipe and Foundry Company.
Download our Tech Tools App for dimensional
info, tech calculators and more on your
mobile device.
4
ABS Foam Core Pipe
ABS Schedule 40 DWV Pipe
(For Non-Pressure Applications)
ABS 3112 1
1
2
x 10 03132 2590 1.900 0.145 27.1
ABS 3112 1
1
2
x 20 03133 5180 1.900 0.145 27.1
ABS 3200 2 x 10 03134 1670 2.375 0.154 37.7
ABS 3200 2 x 20 03135 3340 2.375 0.154 37.7
ABS 3300 3 x 10 03136 750 3.500 0.216 74.5
ABS 3300 3 x 20 03137 1500 3.500 0.216 74.5
ABS 3400 4 x 10 03138 480 4.500 0.237 107.1
ABS 3400 4 x 20 03139 960 4.500 0.237 107.1
ABS 3600 6 x 10 03140 200 6.625 0.280 187.8
ABS 3600 6 x 20 03141 400 6.625 0.280 187.8
Pipe Data
NOT FOR PRESSURE
Do not use PVC / ABS / ABS Plus® cellular core (foam core)
pipe for pressure applications. The use of cellular core pipe
in pressure applications may result in system failure and
property damage.
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
NSF Listed. Meets All Requirements of ASTM F 628.
ABS SCHEDULE 40 FOAM CORE (BLACK) PLAIN END ASTM F 628
MIN. WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT.
611942- SKID (FT.) (IN.) (IN.) (LBS.)
5
ABS Plus® Foam Core DWV Pipe
ABS Plus Schedule 40 DWV Pipe
(For Non-Pressure Applications)
APA 17112 1
12
x 10 12495 2590 1.900 0.145 31.4
APA 17112 1
12
x 20 12494 5180 1.900 0.145 31.4
APA 17200 2 x 10 12497 1670 2.375 0.154 41.9
APA 17200 2 x 20 12496 3340 2.375 0.154 41.9
APA 17300 3 x 10 12499 750 3.500 0.216 84.0
APA 17300 3 x 20 12498 1500 3.500 0.216 84.0
APA 17400 4 x 10 12501 480 4.500 0.237 118.80
APA 17400 4 x 20 12500 960 4.500 0.237 118.80
Pipe Data
NOT FOR PRESSURE
Do not use PVC / ABS / ABS Plus® cellular core (foam core)
pipe for pressure applications. The use of cellular core pipe
in pressure applications may result in system failure and
property damage.
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
NSF Listed. Meets All Requirements of ASTM F 1488.
ABS PLUS SCHEDULE 40 FOAM CORE (BLACK) PLAIN END ASTM F 1488
MIN. WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT.
611942- SKID (FT.) (IN.) (IN.) (LBS.)
ABS Plus is a registered trademark of Charlotte Pipe and Foundry Company.
A
B
S
-
D
W
V
P
I
P
E
6
PVC Foam Core Pipe
PVC Schedule 40 DWV Pipe
(For Non-Pressure Applications)
PVC SCHEDULE 40 FOAM CORE (WHITE) PLAIN END ASTM F 891
NOTE: When ordering, please specify plain end or
bell end.
PVC 4112 1
1
2
x 10 04178 1650 1.900 0.145 32.3
PVC 4112 1
1
2
x 20 04177 3300 1.900 0.145 32.3
PVC 4200 2 x 10 04174 1110 2.375 0.154 43.9
PVC 4200 2 x 20 04173 2220 2.375 0.154 43.9
PVC 4300 3 x 10 03934 1130 3.500 0.216 89.7
PVC 4300 3 x 20 03935 1000 3.500 0.216 89.7
PVC 4400 4 x 10 03936 670 4.500 0.237 123.8
PVC 4400 4 x 20 03937 1340 4.500 0.237 123.8
PVC 4600 6 x 10 03938 330 6.625 0.280 235.0
PVC 4600 6 x 20 03939 660 6.625 0.280 235.0
PVC 4800 8 x 20 03941 360 8.625 0.322 371.0
PVC 4910 10 x 20 03942 220 10.750 0.365 566.3
PVC 4912 12 x 20 03943 120 12.750 0.406 700.0
PVC 4300B
3 x 20 04782 1000 3.500 0.216 89.7
PVC 4400B
4 x 10 04783 670 4.500 0.237 123.8
PVC 4400B
4 x 20 04784 1340 4.500 0.237 123.8
PVC 4600B
6 x 10 09904 330 6.625 0.280 235.0
PVC 4600B
6 x 20 04786 660 6.625 0.280 235.0
PVC SCHEDULE 40 FOAM CORE (WHITE) BELL-END
Pipe Data
NSF Listed. Meets All Requirements of ASTM F 891.
NOT FOR PRESSURE
Do not use PVC / ABS / ABS Plus® cellular core (foam core)
pipe for pressure applications. The use of cellular core pipe
in pressure applications may result in system failure and
property damage.
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
MIN. WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT.
611942- SKID (FT.) (IN.) (IN.) (LBS.)
MIN. WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT.
611942- SKID (FT.) (IN.) (IN.) (LBS.)
7
PVC 7100* 1
1
4
x10 03945 2120 1.660 .140 42.4
PVC 7100* 1
1
4
x20 03946 4240 1.660 .140 42.4
PVC 7112* 1
1
2
x10 03947 1650 1.900 .145 51.8
PVC 7112* 1
1
2
x20 03948 3300 1.900 .145 51.8
PVC 7200* 2x10 03949 1110 2.375 .154 69.5
PVC 7200* 2x20 03950 2220 2.375 .154 69.5
PVC 7300* 3x10 03951 1130 3.500 .216 144.2
PVC 7300* 3x20 03952 1000 3.500 .216 144.2
PVC 7400
4x10 03953 670 4.500 .237 205.5
PVC 7400
4x20 03954 1340 4.500 .237 205.5
PVC 7500
5x20 04837 760 5.563 .258 272.5
PVC 7600
6x10 03955 330 6.625 .280 361.2
PVC 7600
6x20 03956 660 6.625 .280 361.2
PVC 7800
8x10 13087 180 8.625 .322 543.6
PVC 7800
8x20 03958 360 8.625 .322 543.6
PVC 7910
10x20 03959 220 10.750 .365 770.7
PVC 7912
12x20 03961 120 12.750 .406 1019.0
PVC 7914
14x20 04862 60 14.000 .437 1205.0
PVC 7916
16x20 04918 60 16.000 .500 1575.7
PVC Schedule 40 DWV Pipe
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PVC Schedule 40 DWV Pipe
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
WT. PER
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL 100 FT.
611942- SKID (IN.) (IN.) (LBS.)
* Dual Marked ASTM D 1785 & ASTM D 2665.
Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480.
NSF Listed. Meets All Requirements of
ASTM D 1784, ASTM D 1785, and
ASTM D 2665.
Pipe Data
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
P
V
C
S
C
H
4
0
D
W
V
P
I
P
E
8
PVC Sewer Pipe
PVC SDR 35 PSM Pipe
SDR-35 GASKETED - PS 46
PART NO. NOM. SIZE UPC # QTY. PER LAYING WT. PER AVG. OD MIN. WALL
611942- SKID (FT.) LENGTH 100 FT. (LBS.) (IN.) (IN.)
S/M 6004G 4x14 11920 840 14-0 110.4 4.215 .120
S/M 6004G 4x20 04012 1200 20-0 109.7 4.215 .120
S/M 6006G 6x14 11921 462 14-0 249.6 6.275 .180
S/M 6006G 6x20 04016 660 20-0 247.0 6.275 .180
S/M 6008G 8x14 11922 140 14-0 451.0 8.400 .240
ASTM D 3034 & ASTM F 477
Weight is approximate and is for shipping purposes only.
SDR-35 SOLVENT WELD - PS 46
S/M 6004 4x10 04008 600 10-0 108.3 4.215 .120
S/M 6004 4x20 04009 1200 20-0 108.3 4.215 .120
S/M 6006 6x10 04013 330 10-0 241.7 6.275 .180
S/M 6006 6x20 04014 660 20-0 241.7 6.275 .180
Weight is approximate and is for shipping purposes only.
Meets All Requirements of ASTM D 3034.
SDR 35 Gaskets meet or exceed ASTM F 477. Gasketed joints meet ASTM D 3212.
Pipe Data
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
NOT FOR PRESSURE
Do not use PVC Sewer pipe for pressure applications. The
use of sewer pipe in pressure applications may result in
system failure and property damage.
PART NO. NOM. SIZE UPC # QTY. PER LAYING WT. PER AVG. OD MIN. WALL
611942- SKID (FT.) LENGTH 100 FT. (LBS.) (IN.) (IN.)
9
PVC ASTM D 2729 Pipe
SOLVENT WELD BELLED END ASTM D 2729
PVC 30030 3 x 10 10903 810 3.250 0.070 3.00 52.8
PVC 30040 4 x 10 10905 500 4.215 0.075 3.50 70.4
PVC 30060 6 x 10 15149 330 6.275 0.100 4.00 129.0
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL BELL DEPTH WT. PER
611942- SKID (IN.) (IN.) (IN.) 100 FT. (LBS.)
PVC Sewer and Drain Pipe
Pipe Data
Perforated PVC ASTM D 2729 Pipe
SOLVENT WELD BELLED END ASTM D 2729
PVC 30030P
3 x 10 11814 1040 3.250 0.070 3.00 52.8
PVC 30040P
4 x 10 11815 500 4.215 0.075 3.50 70.4
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL BELL DEPTH WT. PER
611942- SKID (IN.) (IN.) (IN.) 100 FT. (LBS.)
Weight is approximate and is for shipping purposes only.
Pipe listed in this section meets or exceeds the requirements of ASTMD 2729.
All products manufactured by Charlotte Pipe and Foundry Company are proudly made
in the U.S.A.
NOT FOR PRESSURE
Do not use PVC Sewer pipe for pressure applications. The
use of sewer pipe in pressure applications may result in
system failure and property damage.
Failure to follow safety precautions may result in
misapplication or improper installation and testing which
can cause severe personal injury and / or property damage.
Primers and cements are extremely flammable and may
be explosive. Do not store or use near heat or open
flame, or death or serious injury may occur.
• Solvent fumes created during the joining process are
heavier than air and may be trapped in newly installed
piping systems.
• Ignition of the solvent vapors caused by spark or flame
may result in injury or death from explosion or fire.
• Read and obey all manufacturers' warnings and any
instructions pertaining to primers and cements.
• Provide adequate ventilation to reduce fire hazard and
to minimize inhalation of solvent vapors when working
with cements, primers and new piping systems.
Perforated pipe is supplied with two rows of 1/2 diameter holes every five inches.
Rows are parallel to the pipe axis and are 120° apart.
P
V
C
S
E
W
E
R
&
D
R
A
I
N
10
ConnecTite® Push-Fit DWV Fittings*
PART NO. CTT 100
ConnecTite Coupling
HUB X HUB
SIZE A B
1
12
18
2
1532
2
18
2
1932
3
632
3
2132
PART NO. CTT 300
ConnecTite 1/4 Bend
HUB X HUB
SIZE A
1
12
1
34
2 2
516
3 3
PART NO. CTT 321
ConnecTite 1/8 Bend
HUB X HUB
SIZE A
1
12
1
332
2 1
1532
3 1
1116
* ConnecTite ttings may be used in PVC-DWV and ABS-DWV systems.
ConnecTite is a registered trademark of Charlotte Pipe and Foundry Company.
11
ConnecTite® Push-Fit DWV Fittings*
PART NO. CTT 400
ConnecTite Sanitary Tee
ALL HUB
SIZE A B
1
12
1
2332
2
2132
2 2
932
3
1932
3 3
132
4
2532
PART NO. CTT 800S
ConnecTite Closet Flange
HUB
SIZE A B C D
4 x 3 7
2
1532 716
1
2332
* ConnecTite ttings may be used in PVC-DWV and ABS-DWV systems.
ConnecTite is a registered trademark of Charlotte Pipe and Foundry Company.
C
O
N
N
E
C
T
I
T
E
F
I
T
T
I
N
G
S
12
PVC and ABS DWV Fittings
ABS
SIZE A B C D
1
1
2
1.910 1.895 .687 .156
2 2.385 2.370 .750 .156
3 3.515 3.495 1.500 .218
4 4.515 4.495 1.750 .250
6 6.647 6.614 3.000 .281
PVC
SIZE A B C D
1
1
4
1.675 1.650 .687 .156
1
1
2
1.915 1.895 .687 .156
2 2.390 2.370 .750 .156
3 3.520 3.495 1.500 .218
4 4.520 4.495 1.750 .250
6 6.647 6.614 3.000 .281
8 8.655 8.610 4.000 .322
10 10.776 10.737 5.000 .365
12 12.778 12.736 6.000 .406
14 14.035 13.985 7.000 .437
16 16.045 15.980 8.000 .500
HUB DIMENSIONS
13
PVC and ABS DWV Fittings
PART NO. 100
Coupling
HUB X HUB
SIZE A B
1
14
18
1
58
1
12
(PVC)
18
1
916
1
12
(ABS)
18
1
58
2
(PVC)
1564
1
34
2 (ABS)
18
1
1316
3
316
3
316
4
14
3
34
6
14
6
14
8
(PVC)
14
8
14
10
(PVC)
516
10
38
12
(PVC)
38
13
716
14(F)
(PVC)
3 17
16(F)
(PVC)
3
38
19
38
(F) Fabricated
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
P
V
C
&
A
B
S
D
W
V
F
I
T
T
I
N
G
S
14
PART NO. 101
Female Adapter
FPT X HUB
SIZE A
1
12
(PVC)
14
1
12
(ABS)
316
2
(PVC)
14
2 (ABS)
532
3
(PVC)
516
3 (ABS)
732
4
1132
6
(PVC)
14
6 (ABS)
332
8
(PVC)
916
10(F)
(PVC)
2
78
12(F)
(PVC)
3
316
PART NO. PVC 101X
Female Adapter with Cleanout Plug
FPT X HUB
SIZE
8
(PVC)
See Part No. 101 and 106
10(F)
(PVC)
12(F)
(PVC)
PVC and ABS DWV Fittings
(F) Fabricated
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
15
PVC and ABS DWV Fittings
PART NO. 102
Pipe Increaser–Reducer
HUB X HUB
SIZE A N
1
12
x 2
(PVC)
2
532
1732
1
12
x 2
(ABS)
2
332
58
1
12
x 3 3
1132
1
332
2 x 3
(PVC)
3
532
78
2 x 3
(ABS)
3
1732
1
18
2 x 4
(PVC)
4 1
38
2 x 4
(ABS)
4
116
1
38
3 x 4 4
316
1516
3 x 6
(PVC)
6
12
2
4 x 6
(PVC)
6
932
1
34
4 x 8
(PVC)
7
12
1
2332
6 x 8
(PVC)
8
1332
1
1332
4 x 10**
(PVC)
11
2564
4
1532
4 x 12**
(PVC)
13
38
5
1932
4 x 14(F)
(PVC)
19 9
34
4 x 16(F)
(PVC)
20
58
10
14
6 x 10
(PVC)
9
2732
1
78
6 x 12**
(PVC)
13
38
4
38
6 x 14(F)
(PVC)
20
34
10
1532
6 x 16(F)
(PVC)
22
18
10
2332
8 x 10
(PVC)
10
34
1
116
8 x 12
(PVC)
12
34
2
116
8 x 14(F)
(PVC)
22
12
11
38
8 x 16(F)
(PVC)
24
14
12
18
10 x 12
(PVC)
12
34
1
1116
10 x 14(F)
(PVC)
17
34
5
34
10 x 16(F)
(PVC)
25 12
12 x 14(F)
(PVC)
16
1116
3
316
12 x 16(F)
(PVC)
20
34
6
716
14 x 16(F)
(PVC)
19
78
4
716
(F) Fabricated
** Assembled from two molded components
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
P
V
C
&
A
B
S
D
W
V
F
I
T
T
I
N
G
S
16
PVC and ABS DWV Fittings
PART NO. 103R
Trap Adapter–Male, with 1
12
PVC Nut &
Washer & 1
12
x 1
14
Washer
DWV SPIGOT X TUBULAR SLIP WITH PVC NUT
SIZE A
1
12
316
PART NO. 103P
Trap Adapter–Male, with Washer &
Polyethylene Nut
DWV SPIGOT X TUBULAR SLIP
SIZE A
1
12
x 1
14
1364
1
12
1364
2
(PVC)
316
PART NO. 103
Trap Adapter–Male, Less Washer &
Metal Nut
DWV SPIGOT X TUBULAR SLIP
SIZE A
1
12
x 1
14
(PVC)
1364
1
12
1364
2
316
PART NO. 103W
Trap Adapter–Male, with Washer & PVC Nut
DWV SPIGOT X TUBULAR SLIP WITH PVC NUT
SIZE A
1
12
x 1
14
1364
1
12
1364
2
316
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
17
PVC and ABS DWV Fittings
PART NO. 104P
Trap Adapter–Female, with Washer
& Polyethylene Nut
DWV HUB X TUBULAR SLIP
SIZE A
1
14
(PVC)
316
1
12
x 1
14
516
1
12
316
PART NO. 104R
Trap Adapter–Female, with 1
12
PVC Nut
& Washer & 1
12
x 1
14
Washer
DWV HUB X TUBULAR SLIP WITH PVC NUT
SIZE A
1
12
316
PART NO. 104
Trap Adapter–Female
NOTE: NOT A MALE ADAPTER.
DWV HUB X TUBULAR SLIP
SIZE A
1
12
x 1
14
516
1
12
316
PART NO. 103X
Trap Adapter–Male, with Washer &
Chrome Nut
DWV SPIGOT X TUBULAR SLIP
SIZE A
1
12
x 1
14
1364
1
12
1364
2
(PVC)
316
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
P
V
C
&
A
B
S
D
W
V
F
I
T
T
I
N
G
S
18
PVC and ABS DWV Fittings
PART NO. 105
Fitting Cleanout Adapter
SPIGOT X FPT
SIZE A B
1
14
(PVC)
316
34
1
12
(PVC)
532
58
1
12
(ABS)
316
2332
2
(PVC)
532
58
2
(ABS)
116
2732
3
(PVC)
732
34
3
(ABS)
732
1
532
4
(PVC)
14
78
4
(ABS)
732
1
932
6
(PVC)
516
1
716
8
(PVC)
38
1
12
10(F)
(PVC)
1516
2
14
12(F)
(PVC)
1
18
2
716
PART NO. 104X
Trap Adapter–Female, with Washer &
Chrome Nut
DWV HUB X TUBULAR SLIP
SIZE A
1
14
(PVC)
316
1
12
x 1
14
516
1
12
316
2
332
PART NO. 104W
Trap Adapter–Female, with Washer
& PVC Nut
DWV HUB X TUBULAR SLIP WITH PVC NUT
SIZE A
1
14
(PVC)
316
1
12
x 1
14
516
1
12
316
2
332
(F) Fabricated
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
19
PVC and ABS DWV Fittings
PART NO. 105X
Fitting Cleanout Adapter with
Cleanout Plug
SPIGOT X FPT
SIZE A
For dimensions see part numbers 105 and 106.
PART NO. 106
Cleanout Plug
MPT
SIZE A B
1
12
1
38
58
2
1
38
58
2
12
(ABS)
1
12
34
3 1
34
34
4 1
78
78
6
(PVC)
2 1
6
(ABS)
1
78
3132
8
(PVC)
2
38
1
38
10
(PVC)
2
716
1
716
12
(PVC)
2
1732
1
1732
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
P
V
C
&
A
B
S
D
W
V
F
I
T
T
I
N
G
S
20
PVC and ABS DWV Fittings
PART NO. 107
Flush Bushing
SPIGOT X HUB
SIZE C
1
1
2
x 1
1
4
3
16
2 x 1
1
4
5
16
2 x 1
1
2
(PVC)
5
16
2 x 1
1
2
(ABS)
1
8
3 x 1
1
2
(PVC)
1
3 x 1
1
2
(ABS)
25
32
3 x 2
(PVC)
7
8
3 x 2
(ABS)
23
32
4 x 2
(PVC)
1
1
8
4 x 2
(ABS)
1
3
16
4 x 3
(PVC)
1
2
4 x 3
(ABS)
1
4
6 x 4
(PVC)
1
3
4
6 x 4
(ABS)
1
21
32
8 x 4
(PVC)
2
7
8
8 x 6
(PVC)
1
5
8
10 x 4**
(PVC)
4
7
16
10 x 6**
(PVC)
3
5
32
10 x 8
(PVC)
1
1
2
12 x 4**
(PVC)
5
5
32
12 x 6**
(PVC)
4
5
32
12 x 8
(PVC)
2
1
2
12 x 10
(PVC)
1
1
2
** Assembled from two molded components
Note: If PVC or ABS is not listed for a specic size, that size tting is available in PVC and
ABS materials, and the dimensions listed are the same for both materials.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Charlotte Pipe PVC 00304 1200 User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI