Plastics Technical Manual
INTRODUCTION
Charlotte Pipe
®
has been relentless in our commitment
to quality and service for more than a century. Through
the years we have broadened and enhanced our product
lines to better serve our customers. As the leading full-line
manufacturer of PVC, CPVC, and ABS piping systems
for drainage and pressure applications, we welcome
the opportunity to be the one-stop source for all your
thermoplastic piping systems. Charlotte
®
is the only
company that manufactures pipe and fittings to exacting
TrueFit tolerances. Our systems are designed to fit together
precisely for easier installation, fewer callbacks and a
lifetime of trouble-free service - the major benefits of a
Charlotte Pipe TrueFit
®
system.
Monroe, North Carolina
Cameron, Texas
Muncy, Pennsylvania
Wildwood, Florida
Manufacturing
Facilities
• Monroe,NorthCarolina
• Muncy,Pennsylvania
• Cameron,Texas
• Wildwood,Florida
• Huntsville,Alabama
• CedarCity,Utah
CharlottePipe,Charlotte,CharlottePipeTrueFit,RePVC,ReUze,and“Youcan’tbeatthesystem”
are registered trademarks of Charlotte Pipe and Foundry Company.
Huntsville, Alabama Cedar City, Utah
3
TABLE OF CONTENTS
GENERAL INFORMATION Page
Introduction ...................................................................................................................... 2
Understanding Safety-Alert Messages .............................................................................. 5
Major Advantages of ABS, PVC and CPVC Pipe .............................................................. 6
Handling and Storage of ABS, PVC and CPVC Pipe ......................................................... 7
Physical Properties of ABS and PVC Materials ................................................................ 8
ABS and PVC Standards ................................................................................................... 8
Physical Properties of FlowGuard Gold
®
, ReUze
®
and Corzan
®
CPVC Materials .............. 9
CPVC Standards ................................................................................................................ 9
Product Specifications ............................................................................................... 10-21
ABSCellularCore(FoamCore)PipeandABSDWVFittingSystem ............................ 10
PVCSchedule40SolidWallPipeandPVCDWVFittingSystem ................................. 11
PVCCellularCore(FoamCore)PipeandPVCDWVFittingSystem ............................ 12
RePVC
®
-PVCSchedule40PipewithRecycledContentandPVCDWV
Fitting System ..................................................................................................... 13
PVC Schedule 40 Pressure Pipe and Fitting System ...................................................... 14
PVC SDR Pressure Pipe and Fitting System ................................................................. 15
PVC Schedule 80 Pressure Pipe and Fitting System ...................................................... 16
FlowGuard Gold CPVC CTS Pipe and Fitting System .................................................... 17
ReUze
®
CPVC CTS Pipe and Fitting System ................................................................. 18
PVC SDR 35 Gravity Sewer Pipe ................................................................................. 19
PVC D 2729 Sewer and Drain Pipe .............................................................................. 20
Product Certification ...................................................................................................... 21
PRODUCT DATA
Pipe Reference Guide ...................................................................................................... 22
Product Data (Dimensions, Weight and Pressure Ratings) ........................................ 23-39
Socket Dimensions for Belled-End Pipe .......................................................................... 34
DESIGN AND ENGINEERING DATA
Pressure/Temperature Relationship ............................................................................ 40-41
MaximumOperatingTemperaturesforVariousPipingSystems ..................................... 40
Temperature De-Rating for PVC and CPVC................................................................... 40
MaximumOperatingTemperaturesforCTSCPVCSDR11PipingSystems ................... 41
Low Temperature Recommendations ............................................................................. 41
Fluid Flow Properties ................................................................................................. 42-51
Gravity Flow and Fluid Flow Rate ............................................................................... 42
Pressure Flow Rate ..................................................................................................... 43
WaterVelocities ......................................................................................................... 43
Friction Loss Through Fittings ..................................................................................... 43
WaterHammer ...................................................................................................... 44-45
Entrapped Air ............................................................................................................. 46
Weathering/UVExposure/HeatBuild-Up .................................................................. 46
Friction Loss and Flow Velocity Table ..................................................................... 47-51
Support Spacing for ABS, PVC and CPVC Pipe ........................................................ 52-53
Typical Pipe Hangers, Clamps, and Supports .................................................................. 53
Expansion and Contraction of Iron Pipe Size ABS, PVC and CPVC .......................... 54-56
ThermalExpansioninDWVSystems............................................................................ 55
ThermalExpansioninUndergroundSystems ................................................................ 55
Expansion and Contraction of CTS CPVC ..................................................................... 56
Permissible Bending Deflections for FlowGuard Gold
®
Pipe ........................................... 57
Flame Spread and Smoke Development Rating for ABS, PVC and CPVC ...................... 58
Chemical Resistance Chart of ABS, PVC, and CPVC ................................................ 59-79
Helpful Reference Standards ..................................................................................... 80-83
Conversion Charts ...................................................................................................... 84-85
ReUzeandRePVCareregisteredtrademarksofCharlottePipeandFoundryCompany.
CorzanandFlowGuardGoldareregisteredtrademarksofLubrizolCorp.
4
Plastics Technical Manual
INSTALLATION
Installation Procedures for ABS, PVC and CPVC Piping Systems ............................ 86-94
FlowGuardGoldandReUze
®
CTS CPVC Pipe and Fitting Systems ........................... 86-88
1/2”-4”ABS,PVCandCPVCPipeandFittingSystems .......................................... 88-90
6”andLargerABS,PVCandCPVCPipeandFittingSystems................................. 90-93
Solvent Cements .......................................................................................................... 94
Applicator Types .......................................................................................................... 94
Joint Curing .................................................................................................................... 95
Flanges ............................................................................................................................ 96
Threaded Joints and Threading of PVC and CPVC Pipe .......................................... 97-100
Taper Thread Dimensions .......................................................................................... 100
ImportantInformationforFittingswithPlasticorMetalNuts ................................... 100
Joining Roll-Grooved Pipe ............................................................................................. 101
Antifreeze Solutions - Pressure Testing CPVC and PVC at Reduced Temperatures ...... 101
Antifreeze Solutions for ABS DWV Systems ................................................................. 102
Underground Installation .............................................................................................. 102
Trenching .................................................................................................................. 102
Bedding and Backfilling ............................................................................................. 102
CTS CPVC Under-Slab Installations ............................................................................. 103
ABS and PVC Under-Slab Instalations ........................................................................... 103
In-Slab Installations ...................................................................................................... 103
Testing and Inspection .................................................................................................. 103
Testing DWV System ..................................................................................................... 103
Testing Pressure System ............................................................................................... 104
SPECIAL CONSIDERATIONS
FlowGuard Gold
®
Domestic Water Systems .................................................................. 105
Advantages of a FlowGuard Gold CPVC System ........................................................... 105
Chemical Compatibility with CPVC Products ............................................................... 105
CTS CPVC Pipe Passing Through Studs ........................................................................ 106
Closed-Loop Systems .................................................................................................... 106
Connecting CTS CPVC to Fixtures or Other Materials .......................................... 106-107
Disinfection ................................................................................................................... 107
Elevated-Temperature Performance ....................................................................... 107-108
Horizontal and Vertical Support .................................................................................... 108
HVAC Condensate Drain Lines ...................................................................................... 108
Low Temperature Recommendation .............................................................................. 108
Cold Weather Considerations for CPVC ........................................................................ 109
Heat Build-Up ............................................................................................................... 109
Thermal Conductivity and Sweating of CTS CPVC ................................................ 109-110
Water Hammer Arrestors .............................................................................................. 110
FlowGuard Gold and Corzan Domestic Water Systems Do’s and Dont’s ................ 110-111
Hydronic Heating, Chilled Water or Geothermal Applications .............................. 112-113
Material Selection, Special System Design and Engineering Considerations ........ 114-115
SelectionofMaterialforSanitaryandStormDrainage ............................................. 114
Engineered Applications ........................................................................................... 114
UnstableSoil ........................................................................................................... 115
UsingPlasticsinMulti-StoryConstruction ................................................................ 115
UsingPlasticsforVentingCombustionGases ............................................................. 115
Repairs or Modifications to Existing CPVC CTS Systems ............................................. 115
LIMITED WARRANTY ......................................................................................................... 116
FLOWGUARD GOLD CPVC CTS LIMITED WARRANTY ...................................................... 117
TABLE OF CONTENTS
CorzanandFlowGuardGoldareregisteredtrademarksofLubrizolCorp.
5
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid
personal injury or death.
It is important to read and understand this manual. It contains information to help protect your safety and prevent
problems.
GENERAL INFORMATION
Understanding Safety Alert Messages
WARNING Indicates a hazardous situation which, if not
avoided, could result in severe injury or death.
CAUTION Indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE Indicates a hazardous situation which, if not
avoided, may result in system failure and property damage.
6
Plastics Technical Manual
• WhileABS,PVCandCPVCareverydifferentmaterials,
they share numerous advantages common to plastic piping
systems. Advantages include ease of installation, corrosion
resistance, low friction loss, initial cost, and longevity.
Easy Installation
ABS, PVC and CPVC systems are light in weight
(approximately one-half the weight of aluminum and
one-sixth the weight of steel) reducing transportation,
handling, and installation cost. They have smooth,
seamlessinteriorwalls.Nospecialtoolsarerequiredfor
cutting. These materials can be installed using the solvent
cement joining technique.
Strength
• ABS,PVCandCPVCproductsarehighlyresilient,tough
and durable with high tensile and high impact strength.
Freedom from Toxicity, Odors, Tastes
• PVCandCPVCpipingsystemsdesignedfordomesticwater
applicationsarelistedtoconformtoNSFInternational
Standard61.ThisHealthEffectsstandardensuresthe
safety of products coming into contact with drinking
water.
Corrosion Free External and Internal
• With many other pipe materials, slight corrosion may
occur. The corroded particles can contaminate the
piped fluid, complicating further processing, or causing
bad taste, odors, or discoloration. This is particularly
undesirable when the piped fluid is for domestic
consumption.WithPVCandCPVC,therearenocorrosive
by-products, therefore, no contamination of the piped
fluid.
Immunity to Galvanic or Electrolytic Attack
• ABS,PVCandCPVCareinherentlyimmunetogalvanic
or electrolytic action. They can be used underground,
underwater, in the presence of metals, and can be
connected to metals.
Fire Resistance
• PVC and CPVC piping systems are self extinguishing
andwillnotsupportcombustion.TheASTME84test
protocol is used to determine the flame and smoke rating
for various materials.
• PVCwillnotpasstheASTME-8425/50amespread
/smokedevelopedtestandisnotacceptableforusein
plenum areas.
• Consult Charlotte Pipe for additional information on
CPVC in plenum applications.
For plenum applications, follow prevailing code
requirements.
Low Friction Loss
• The smooth interior surfaces of ABS, PVC and CPVC
assure low friction loss and high flow rate. Additionally,
since ABS, PVC and CPVC pipe resist rusting, pitting,
scaling and corrosion, the high flow rate can be maintained
for the life of the piping system.
Low Thermal Conductivity
PVC and CPVC pipe have a much lower thermal
conductivity factor than metal pipe. Therefore, fluids
being piped maintain a more constant temperature. In
many cases, pipe insulation is not required.
Major Advantages of ABS,
PVC and CPVC Pipe
GENERAL INFORMATION
Tothebestofourknowledgetheinformationcontainedinthispublicationisaccurate.However,CharlottePipeandFoundrydoesnot
assume any liability whatsoever for the accuracy or completeness of such information. Final determination of the suitability of any
information or product for the use to be contemplated is the sole responsibility of the user. The manner of that use and whether there is
any infringement of patents is also the sole responsibility of the user.
To reduce the risk of death or serious injury from an explo-
sion, collapse or projectile hazard and to reduce the risk of
property damage from a system failure:
Always follow the warnings and procedures provided in
this manual.
Only use PVC/ABS/CPVC pipe and fitting for the
conveyance of fluids as defined within the applicable
ASTM standards.
Never use PVC/ABS/CPVC pipe and fittings for the
conveyance of gasses.
Never use PVC/ABS/CPVC pipe or fittings in structural
application or in any load-bearing applications.
Never strike the pipe or fittings or drive them into the
ground or into any other hard substance.
7
GENERAL INFORMATION
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
• NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe for water
or approved chemicals.
• Refer to warnings in PPFA User Bulletin
4-80 and ASTM D 1785.
Cost Effective
• ABS,PVCandCPVCproductsareextremelylightweight,
convenient to handle, relatively flexible, and easy to
install. These features lead to lower installed cost than
other piping systems.
Virtually Maintenance Free
• OnceanABS,PVCorCPVCsystemisproperlyselected,
designed, and installed, it is virtually maintenance free.
Therefore, years of trouble-free service can be expected
when using Charlotte Pipe and Foundry ABS, PVC and
CPVC systems.
Handling and Storage of ABS,
PVC and CPVC Pipe
Receiving Pipe
As pipe is received, it must always be thoroughly inspected,
prior to unloading. The person receiving the pipe must look for
any transportation damage caused by over-tightened tie-down
straps, improper treatment, or a shift in the load.
Pipe received in a closed trailer must be inspected as the trailer
is opened. Take extra time to ensure that the pipe has not been
damaged by other materials having been stacked on top of it,
load shift, or rough handling.
Visually examine the pipe ends for any cracks, splits, gouges,
or other forms of damage. Additionally, the pipe should be
inspected for severe deformation which could later cause
joining problems. The entire inside diameter of larger diameter
pipe(4”andabove)mustbecheckedforanyinternalsplitsor
cracks which could have been caused by loading or transit. The
use of a flashlight may be necessary to perform this inspection.
Any damages must be observed by all parties involved,
including the driver, and should be clearly noted on the bill of
ladingand/ordeliveryticket.Acopyofthisdocumentshould
be retained by the receiver. In addition, the manufacturer and
carrier should be notified, within 24 hours, of any damages,
shortages, or mis-shipped products.
Handling Pipe
The pipe should be handled with reasonable care. Because
thermoplastic pipe is much lighter in weight than metal pipe,
there is sometimes a tendency to throw it around. This should
be avoided.
The pipe should never be dragged or pushed from a truck bed.
Removing and handling pallets of pipe should be done with a
forklift. Loose pipe lengths require special handling to avoid
damage. Precautions to follow when unloading and handling
loose pieces include not banging lengths together or dropping
lengths, even from low heights, on hard or uneven surfaces.
In all cases, severe contact with any sharp objects (rocks,
angle irons, forks on forklifts, etc.) should be avoided. Also,
the pipe should never be lifted or moved by inserting the forks
of a forklift into the pipe ends.
HandlingPVCandparticularlyCPVCpipediametersgreater
than 4-inch requires extra care as the added pipe weight can
cause cracking from relatively minor impacts. Also, plastic
pipe becomes more brittle as the temperature decreases. The
impact strength and flexibility of PVC and especially CPVC
pipe are reduced. Therefore, take extra care when handling
skids or loose lengths when the temperature drops below 50°F.
Storing Pipe
If possible, pipe should be stored inside. When this is not
possible, the pipe should be stored on level ground which is
dry and free from sharp objects. If different schedules of pipe
are stacked together, the pipe with the thickest walls should
be on the bottom.
If the pipe is in pallets, the pallets should be stacked with the
pallet boards touching, rather than pallet boards being placed
on the pipe. This will prevent damage to or bowing of the pipe.
If the pipe is stored in racks, it should be continuously
supported along its length. If this is not possible, the spacing
ofthesupportsshouldnotexceedthreefeet(3’).
The pipe should be protected from the sun and be in an area
with proper ventilation. This will lessen the effects of ultraviolet
rays and help prevent heat build-up.
8
Plastics Technical Manual
ABS DWV
Schedule40DWVFoamCorePipe ASTMD3965 ASTMF628
Schedule40DWVFittings ASTMD3965 ASTMD2661
PVC DWV
Schedule40DWVPipe ASTMD1784
ASTMD2665&ASTMD1785
Schedule40DWVFoamCorePipe ASTMD4396 ASTMF891
Schedule40DWVPipewithRecycledContent ASTMD4396 ASTMF1760
Schedule40DWVFittings ASTMD1784 ASTMD2665
FabricatedSchedule40DWVFittings ASTMD1784 ASTMF1866
PVC Pressure
Schedule40PlainEndPipe ASTMD1784 ASTMD1785
Schedule40BellEndPipe ASTMD1784 ASTMD1785
Schedule40BellEndWellCasing ASTMD1784 ASTMD1785&ASTMF480
SDR21(PR200)BellEndPipe ASTMD1784 ASTMD2241
SDR26(PR160)BellEndPipe ASTMD1784 ASTMD2241
Schedule40Fittings ASTMD1784 ASTMD2466
Schedule80PlainEndPipe ASTMD1784 ASTMD1785
Schedule80Fittings ASTMD1784 ASTMD2464&ASTMD2467
SpecicGravity g/cc 1.05 D792 1.40 D792
TensileStrength(73°F)Minimum Psi 4,500 D638 7,000 D638
ModulusofElasticityinTension(73°F)Minimum Psi 240,000 D638 400,000 D638
Flexural Strength (73°F) Psi 10,585 D 790 14,000 D 790
IzodImpact(notchedat73°F)Minimum ftlb/in.ofnotch 6.00 D256 0.65 D256
Hardness(DurometerD) 70 D2240 80±3 D2240
Hardness(RockwellR) 100 D785 110-120 D785
Compressive Strength (73°F) Psi 7,000 D 695 9,600 D 695
HydrostaticDesignStress Psi N/A 2,000 D1598
CoefcientofLinearExpansion in./in./°F 5.5x10
-5
D 696 3.0 x 10
-5
D 696
HeatDistortionTemperatureat264psiMinimum degreesF 180 D648 160 D648
CoefcientofThermalConductivity BTU/hr/sqft/°F/in. 1.1 C177 1.2 C177
SpecicHeat BTU/°F/lb 0.35 D2766 0.25 D2766
WaterAbsorption(24hrsat73°F) %weightgain 0.40 D570 .05 D570
Cell Classification - Pipe 42222 D 3965 12454 D 1784
Cell Classification - Fittings 32222 D 3965 12454 D 1784
Burning Rate Self Ext. D 635
BurningClass V-0 UL94**
MATERIAL DIMENSIONS
PROPERTY UNITS ABS ASTM NO. PVC ASTM NO.
ABS and PVC Standards
*Abovedataisbaseduponinformationprovidedbytherawmaterialmanufacturers.Itshouldbeusedonlyasa
recommendationandnotasaguaranteeofperformance.**UnderwritersLaboratoriesstandard
TYPE PIPE / FITTING
STANDARD SPECIFICATIONS
GENERAL INFORMATION
Physical Properties of Charlotte Pipe
®
ABS and PVC Materials
*
9
CPVC Pressure
CPVCSchedule80PlainEndPipe(Corzan) ASTMD1784 ASTMF441
CPVCSchedule80Fittings(Corzan) ASTMD1784 ASTMF437andASTMF439
CPVCCTSTubeandFittings(FlowGuardGold,ReUze
®
) ASTMD1784 ASTMD2846
PROPERTY CPVC 4120 UNITS ASTM No.
CPVC Standards
*Abovedataisbaseduponinformationprovidedbytherawmaterialmanufacturers.Itshouldbeusedonlyasa
recommendationandnotasaguaranteeofperformance.**UnderwritersLaboratoriesstandard
TYPE PIPE / FITTINGS
STANDARD SPECIFICATIONS
MATERIAL DIMENSIONS
SpecicGravity 1.55 g/cc D792
TensileStrength(73°F)Minimum 7,000 psi D638
ModulusofElasticityinTension(73°F) 360,000 psi D638
Flexural Strength (73°F) 15,100 psi D 790
IzodImpactCellClass23447(notchedat73°F)Minimum 1.5 ftlb/in.ofnotch D256
IzodImpactCellClass24448(notchedat73°F)Minimum 5.0 ftlb/in.ofnotch D256
Hardness(DurometerD) — D2240
Hardness(RockwellR) 119 D785
Compressive Strength (73°F) 10,100 psi D 695
HydrostaticDesignStress 2,000 psi
Coefficient of Linear Expansion 3.4 x 10
-5
in./in./°F D696
HeatDistortionTemperatureat264psiMinimum 212(CellClass23447) degreesF D648
HeatDistortionTemperatureat264psiMinimum 230(CellClass24448) degreesF D648
CoefcientofThermalConductivity .95 BTU/hr/sqft/°F/in. C177
SpecicHeat .34 BTU/°F/lb D2766
WaterAbsorption(24hrsat73°F) .03 %weightgain D570
Cell Classification 23447 - 24448 D 1784
Burning Rate Self Extinguishing D 635
BurningClass V-0 UL94**
GENERAL INFORMATION
Physical Properties of FlowGuard Gold
®
, ReUze
®
& Corzan
®
CPVC Materials
*
CorzanandFlowGuardGoldareregisteredtrademarksofLubrizolCorp.
10
Plastics Technical Manual
Product Specifications
System: ABS Cellular Core (Foam Core) Pipe and ABS DWV Fitting System
Scope: ThisspecicationcoversABScellularcore(foamcore)pipeandABSDWVttingsusedinsanitary
drain,waste,andvent(DWV),sewer,andstormdrainageapplications.Thissystemisintendedforusein
non-pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe shall be manufactured from virgin rigid ABS (acrylonitrile-butadiene-styrene) compounds with a
CellClassof42222asidentiedinASTMD3965.FittingsshallbemanufacturedfromvirginrigidABS
compoundswithaCellClassof32222asidentiedinASTMD3965.
ABScellularcorepipeshallbeIronPipeSize(IPS)conformingtoASTMF628.ABSDWVttings
shallconformtoASTMD2661.Pipeandttingsshallbemanufacturedasasystemandbetheproduct
ofonemanufacturer.AllpipeandttingsshallbemanufacturedintheUnitedStates.Allsystemsshall
utilizeaseparatewasteandventsystem.PipeandttingsshallconformtoNSFInternationalStandard
14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall
beinstalledinaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemade
withasolventcementconformingtoASTMD2235.Thesystemshallbeprotectedfromchemicalagents,
fire stopping materials, thread sealant, or other aggressive chemical agents not compatible with ABS
compounds. Systems shall be hydrostatically tested after installation. WARNING!Nevertestwithor
transport/storecompressedairorgasinABSpipeorttings.
Referenced Standards*:
ASTMD3965 RigidABSCompounds
ASTMF628 Co-extrudedABSPipewithCellularCore
ASTMD2661 ABSDrain,Waste,andVentFittings
ASTMD2235 SolventCementsforABSPipeandFittings
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
Pipe and fittings shall be manufactured from ABS compound with a cell class of 42222
for pipe and 32222 for fittings as per ASTM D 3965 and conform with NSF International
Standard14.Pipeshallbeironpipesize(IPS)conformingtoASTMF628.Fittingsshallconformto
ASTMD2661.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements.Buriedpipeshallbeinstalled in
accordancewithASTMD2321andASTMF1668.SolventcementshallconformtoASTMD2235.The
system is to be manufactured by Charlotte Pipe and Foundry Company and is intended for non-pressure
drainage applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
11
Product Specifications
System: PVC Schedule 40 Solid Wall Pipe and PVC DWV Fitting System
Scope: ThisspecicationcoversPVCSchedule40solidwallpipeandPVCDWVttingsusedinsanitarydrain,
waste,andvent(DWV),sewer,andstormdrainageapplications.Thissystemisintendedforuseinnon-
pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with
aCellClassof12454asidentiedinASTMD1784.
PVCSchedule40pipeshallbeIronPipeSize(IPS)conformingtoASTMD1785andASTMD2665.
InjectionmoldedPVCDWVttingsshallconformtoASTMD2665.FabricatedPVCDWVttingsshall
conformtoASTMF1866.Pipeandttingsshallbemanufacturedasasystemandbetheproductofone
manufacturer.AllpipeandttingsshallbemanufacturedintheUnitedStates.Allsystemsshallutilize
aseparatewasteandventsystem.PipeandttingsshallconformtoNSFInternationalStandard14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be
installedinaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemadein
atwostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTM
D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant,
plasticizedvinyl products, orotheraggressivechemicalagents notcompatiblewithPVCcompounds.
Systems shall be hydrostatically tested after installation. WARNING! Nevertestwithortransport/store
compressed air or gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD1785 PVCPlasticPipe,Schedule40
ASTMD2665 PVCDrain,Waste,andVentPipe&Fittings
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
ASTMF1866 FabricatedPVCDWVFittings
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeandttingsshallbemanufacturedfromPVCcompoundwithacellclassof12454perASTMD1784
andconformwithNSFInternationalStandard14.Pipeshallbeironpipesize(IPS)conformingtoASTM
D1785andASTMD2665.InjectionmoldedttingsshallconformtoASTMD2665.Fabricatedttings
shallconformtoASTMF1866.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements. Buried pipe shall be installed in
accordancewithASTMD2321andASTMF1668.SolventcementsshallconformtoASTMD2564,primer
shallconformtoASTMF656.ThesystemistobemanufacturedbyCharlottePipeandFoundryCompany
and is intended for non-pressure drainage applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
12
Plastics Technical Manual
Product Specification
System: PVC Cellular Core (Foam Core) Pipe and PVC DWV Fitting Systems
Scope: Thisspecication coversPVCcellularcore(foam core)pipeandPVC DWVttingsusedinsanitary
drain,waste,andvent(DWV),sewer,andstormdrainageapplications.Thissystemisintendedforusein
non-pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class
of11432asidentiedinASTMD4396.FittingsshallbemanufacturedfromvirginrigidPVC(polyvinyl
chloride)vinylcompoundswithaCellClassof12454asidentiedinASTMD1784.
PVCcellularcorepipeshallbeIronPipeSize(IPS)conformingtoASTMF891.InjectionmoldedPVC
DWVttingsshallconformtoASTMD2665.FabricatedPVCDWVttingsshallconformtoASTMF
1866. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All
pipeandttingsshallbemanufacturedintheUnitedStates.Allsystemsshallutilizeaseparatewaste
andventsystem.PipeandttingsshallconformtoNSFInternationalStandard14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall be
installedinaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemadein
atwostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTM
D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant,
plasticizedvinyl products, orotheraggressivechemicalagents notcompatiblewithPVCcompounds.
Systems shall be hydrostatically tested after installation. WARNING! Nevertestwithortransport/store
compressed air or gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD4396 CompoundsforCellularCorePipe
ASTMF891 Co-extrudedPVCPipewithCellularCore
ASTMD2665 PVCDrain,Waste,andVentFittings
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
ASTMF1866 FabricatedPVCDWVFittings
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeshallbemanufacturedfromPVCcompoundwithacellclassof11432perASTMD4396and12454
perASTMD1784forttingsandconformwithNSFInternationalStandard14.Pipeshallbeironpipe
size(IPS)conformingtoASTMF891.InjectionmoldedPVCDWVttingsshallconformtoASTMD
2665.FabricatedPVCDWVttingsshallconformtoASTMF1866.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements. Buried pipe shall be installed in
accordancewithASTMD2321andASTMF1668.SolventcementsshallconformtoASTMD2564,primer
shallconformtoASTMF656.ThesystemistobemanufacturedbyCharlottePipeandFoundryCompany
and is intended for non-pressure drainage applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
13
GENERAL INFORMATION
System: RePVC
®
– PVC Schedule 40 Pipe with Recycled Content and PVC DWV Fitting System
Scope:
ThisspecicationcoversPVCSchedule40pipewithrecycledcontentandPVCDWVttingsusedinsanitary
drain,waste,andvent (DWV),sewerandstorm drainageapplications. Thissystemisintendedfor usein
non-pressure applications where the operating temperature will not exceed 140°F.
Specification:
Inside and outside layers of pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl
compoundswithaminimumcellclassof11432perASTMD4396.Centerlayerofpipeshallbemanufactured
fromrecycledPVCcompoundswithaminimumcellclassof11211perASTMD4396.Fittingsshallbe
manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of 12454 as
identiedinASTMD1784.
Centerlayerofpipeshallbecomprisedof100%recycledmaterialandmakeup30–80%ofthepipe’soverall
wall thickness.
CoextrudedPVCpipewithrecycledcontentshallbeSchedule40ironpipesize(IPS)conformingtoASTM
F1760.InjectionmoldedPVCDWVttingsshallconformtoASTMD2665.FabricatedPVCDWVttings
shallconformtoASTMF1866.Pipeandttingsshallbemanufacturedasasystemandbetheproductof
onemanufacturer.AllpipeandttingsshallbemanufacturedintheUnitedStates.Allsystemsshallutilize
aseparatewasteandventsystem.PipeandttingsshallconformtoNSFInternationalStandard14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall be
installedinaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemadeina
twostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTMD2564.
The system shall be protected from chemical agents, re stopping materials, thread sealant, plasticized
vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be
hydrostatically tested after installation. WARNING!
Nevertestwithortransport/storecompressedairor
gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD4396 CompoundsforCellularCorePipe
ASTMF1760 Co-extrudedPVCPipewithRecycledContent
ASTMD2665 PVCDrain,Waste,andVentFittings
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
ASTMF1866 FabricatedPVCDWVFittings
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
Pipe shall be manufactured from PVC compound with a minimum cell class of 11432 for the inside and
outsidelayersand11211forthecenterlayerperASTMD4396.Centerlayerofpipeshallbecomprisedof
100%recycledmaterialandmakeup30–80%oftheoverallwallthickness.PipeshallbeSchedule40iron
pipesize(IPS)conformingtoASTMF1760.
Fittingsshall be manufactured from virgin rigid PVCcompound with a cellclass of 23447 per ASTM D
1784andconformwithNSFInternationalStandard14.InjectionmoldedPVCDWVttingsshallconform
toASTMD2665.FabricatedPVCDWVttingsshallconformtoASTMF1866.
All pipe and fittings shall be produced by a single manufacturer and be installed in accordance with manufac-
turer’srecommendationsandapplicablecoderequirements.Buriedpipeshallbeinstalledinaccordancewith
ASTMD2321andASTMF1668.SolventcementsshallconformtoASTMD2564,primershallconform
toASTMF656.ThesystemtobemanufacturedbyCharlottePipeandFoundryCo.andisintendedfornon-
pressure drainage applications where the temperature will not exceed 140°F.
RePVC is a registered trademark of Charlotte Pipe and Foundry Company.
Product Specification
14
Plastics Technical Manual
Product Specifications
System: PVC Schedule 40 Pressure Pipe and Fitting System
Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is
intended for pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with
aCellClassof12454asidentiedinASTMD1784.
PVCSchedule40pipeshallbeIronPipeSize(IPS)conformingtoASTMD1785.PVCSchedule40
ttingsshallconformtoASTMD2466.Pipeandttingsshallbemanufacturedasasystemandbethe
productofonemanufacturer.AllpipeandttingsshallbemanufacturedintheUnitedStates.Pipeand
ttingsshallconformtoNSFInternationalStandard61orthehealtheffectsportionofNSFStandard
14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be
installedinaccordancewithASTMF1668andASTMD2774.Solventcementjointsshallbemadein
atwostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTM
D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant,
plasticizedvinyl products, orotheraggressivechemicalagents notcompatiblewithPVCcompounds.
Systems shall be hydrostatically tested after installation. WARNING! Nevertestwithortransport/store
compressed air or gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD1785 PVCPlasticPipe,Schedule40
ASTMD2466 PVCPlasticFittings,Schedule40
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2774 UndergroundInstallationofThermoplasticPressurePiping
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
NSFStandard61 DrinkingWaterSystemComponents-HealthEffects
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeandttingsshallbemanufacturedfromPVCcompoundwithacellclassof12454perASTMD1784
andconformwithNSFInternationalStandards14and61.Pipeshallbeironpipesize(IPS)conforming
toASTMD1785.FittingsshallconformtoASTMD2466.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements.Buriedpipeshallbeinstalled in
accordancewithASTMF1668andASTMD2774.SolventcementsshallconformtoASTMD2564,
primershallconformtoASTMF656.ThesystemistobemanufacturedbyCharlottePipeandFoundry
Company and is intended for pressure applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
15
Product Specifications
System: PVC SDR Pressure Pipe and Fitting System
Scope: This specification covers PVC Standard Dimensional Ratio (SDR) pipe and fittings for pressure applications.
This system is intended for pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with
aCellClassof12454asidentiedinASTMD1784.
PVCSDRpipeshallbeIronPipeSize(IPS)conformingtoASTMD2241forplainendpipeandASTM
D2672forbelled-endpipe.PVCSchedule40(IPS)ttingsshallconformtoASTMD2466.Pipeand
fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings
shallbemanufacturedintheUnitedStates.PipeandttingsshallconformtoNSFInternationalStandard
61orthehealtheffectsportionofNSFStandard14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be
installedinaccordancewithASTMF1668andASTMD2774.Solventcementjointsshallbemadeina
twostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTMD2564.
Thesystemshallbeprotectedfromchemicalagents,restoppingmaterials,threadsealant,plasticized
vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall
be hydrostatically tested after installation. WARNING! Nevertestwithortransport/storecompressedair
or gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD2241 PVCPressureRatedPipe(SDRSeries)
ASTMD2672 JointsforIPSPVCPipeUsingSolventCement
ASTMD2466 PVCPlasticFittings,Schedule40
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2774 UndergroundInstallationofThermoplasticPressurePiping
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
NSFStandard61 DrinkingWaterSystemComponents-HealthEffects
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeandttingsshallbemanufacturedfromPVCcompoundwithacellclassof12454perASTMD1784
andconformwithNSFInternationalStandards14and61.Pipeshallbeironpipesize(IPS)conforming
toASTMD2241forplain-endpipeandASTMD2672forbelled-endpipe.PVCSchedule40ttingsshall
conformtoASTMD2466.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements. Buried pipe shall be installed in
accordancewithASTMF1668andASTMD2774.SolventcementsshallconformtoASTMD2564,
primershallconformtoASTMF656.ThesystemistobemanufacturedbyCharlottePipeandFoundry
Company and is intended for pressure applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
16
Plastics Technical Manual
Product Specifications
System: PVC Schedule 80 Pressure Pipe and Fitting System
Scope: This specification covers PVC Schedule 80 pipe and fittings for pressure applications. This system is intended
for pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a
CellClassof12454asidentiedinASTMD1784.
PVCSchedule80pipeshallbeIronPipeSize(IPS)conformingtoASTMD1785.PVCSchedule80ttings
shallconformtoASTMD2467.PVCSchedule80threadedttingsshallconformtoASTMD2464.Pipe
and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings
shallbemanufacturedintheUnitedStates.PipeandttingsshallconformtoNSFInternationalStandard
61orthehealtheffectsportionofNSFStandard14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be
installedinaccordancewithASTMF1668andASTMD2774.Solventcementjointsshallbemadeinatwo
stepprocessusingIPSP-70orOateyIndustrialGradeprimersandsolventcementconformingtoASTMD
2564.Thesystemshallbeprotectedfromchemicalagents,restoppingmaterials,threadsealant,plasticized
vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be
hydrostatically tested after installation. WARNING! Nevertestwithortransport/storecompressedairor
gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD1785 PVCPlasticPipe,Schedule80
ASTMD2464orD2467 PVCThreadedFittings,Schedule80
ASTMD2467 PVCSocketFittings,Schedule80
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMD2774 UndergroundInstallationofThermoplasticPressurePiping
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
NSFStandard61 DrinkingWaterSystemComponents-HealthEffects
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeandttingsshallbemanufacturedfromPVCcompoundwithacellclassof12454perASTMD1784
andconformwithNSFInternationalStandards14and61.Pipeshallbeironpipesize(IPS)conforming
toASTMD1785.SocketttingsshallconformtoASTMD2467;threadedttingsshallconformtoASTM
D2464orD2467.FlangesshallmeettheboltpatternrequirementsofANSI/ASMEB16.5.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
manufacturer’s recommendations and applicable code requirements. Buried pipe shall be installed in
accordancewithASTMF1668andASTMD2774.SolventcementsshallconformtoASTMD2564,primer
shall be IPS P-70 or Oatey Industrial Grade. The system is to be manufactured by Charlotte Pipe and Foundry
Company and is intended for pressure applications where the temperature will not exceed 140°F.
GENERAL INFORMATION
17
System: FlowGuard Gold® CPVC Copper Tube Size (CTS) Hot and Cold Domestic Water Distribution
System
Scope: ThisspecicationcoversCopperTubeSize(CTS)CPVCmanufacturedtostandarddimensionalratio(SDR)
11 for hot and cold domestic water distribution. This system is intended for pressure applications where
the operating temperature will not exceed 180°F at 100 psi.
Specification: Pipe and fittings shall be manufactured from virgin rigid Chlorinated Poly (Vinyl Chloride) (CPVC)
compoundswithaCellClassof24448forpipeand23447forttingsperASTMD1784.
FlowGuardGoldCTSCPVCpipeandttingsshallconformtoASTMD2846.Pipeandttingsshallbe
manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured
intheUnitedStates.PipeandttingsshallconformtoNSFInternationalStandards14and61.
Installation shall comply with latest installation instructions published by Charlotte Pipe and Foundry and
shall conform to all applicable plumbing, building and fire code requirements. Buried pipe shall be installed
inaccordancewithASTMF1668andASTMD2774.SolventweldjointsshallbemadeusingCPVCcement
conformingtoASTMF493.Yellowone-stepcementmaybeusedwithoutprimer.Ifaprimerisrequired
byapplicableplumbingorbuildingcodes,thenaprimerconformingtoASTMF656shouldbeused.The
systemshallbeprotectedfromchemicalagents,restoppingmaterials,threadsealant,plasticizedvinyl
products or other aggressive chemical agents not compatible with CPVC compounds. Systems shall be
hydrostatically tested after installation. WARNING! Nevertestwithortransport/storecompressedairor
gas in CPVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD2774 UndergroundInstallationofThermoplasticPressurePiping
ASTMD2846 CPVCPlasticHotandColdWaterDistributionSystem
ASTMF493 SolventCementsforCPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
NSFStandard61 DrinkingWaterSystemComponents-HealthEffects
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
Specification for FlowGuard Gold CPVC Copper Tube Size (CTS) Hot and Cold Domestic Water
Distribution System
All pipe and fittings shall be manufactured from CPVC compound with a cell class of 24448 for pipe and
23447forttingsasperASTMD1784andconformwithNSFInternationalStandards14and61.
Pipe and fittings to be FlowGuard Gold
®
CPVCCopperTubeSizemanufacturedtostandarddimensionratio
(SDR)11andshallconformtoASTMD2846.Transitionttingstohavebrassmaleorfemalethreads
with integral CPVC socket connections as manufactured by Charlotte Pipe and Foundry Company.
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance
withmanufacturer’srecommendationsandapplicablecoderequirements.Buriedpipeshallbeinstalled
inaccordancewithASTMF1668andASTMD2774.SolventcementshallconformtoASTMF493
and system may be installed with approved one-step cement. Pipe and fittings are to be manufactured by
Charlotte Pipe and Foundry Company and are intended for hot and cold water distribution systems.
Product Specifications
GENERAL INFORMATION
FlowGuardGoldandCorzanareregisteredtrademarksofLubrizolCorp.
18
Plastics Technical Manual
System: ReUze
®
CPVC Copper Tube Size (CTS) Non-Potable Water Distribution System
Scope: ThisspecicationcoversCopperTubeSize(CTS)CPVCmanufacturedtostandarddimensionalration
(SDR) 11 for non-potable water distribution. This system is intended for pressure applications where the
operating temperature will not exceed 180˚F at 100 psi.
Specification: Pipe and fittings shall be manufactured from virgin rigid Chlorinated Poly (Vinyl Chloride) (CPVC)
compoundswithaCellClassof24448asidentiedinASTMD1784.
ReUzeCTSCPVCpipeandttingsshallconformtoASTMD2846.Pipeandttingsshallbemanufactured
as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the
UnitedStates.PipeandttingsshallconformtoNSFInternationalStandard14.Thepipeshallbelisted
byNSFInternationalforreclaimedwaterandbearthemark“NSF-rw.”
Installation shall comply with latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, building and fire code requirements. Buried pipe shall
beinstalledinaccordancewithASTMF1668andASTMD2774.Solventweldjointsshallbemade
usingCPVCcementconformingtoASTMF493.Yellowone-stepcementmaybeusedwithoutprimer.
Ifaprimerisrequiredbyapplicableplumbingorbuildingcodes,thenaprimerconformingtoASTM
F 656 should be used. The system shall be protected from chemical agents, fire stopping materials,
threadsealant,plasticizedvinylproductsorotheraggressivechemicalagentsnotcompatiblewithCPVC
compounds. System shall be hydrostatically tested after installation. WARNING! Never testwith or
transport/storecompressedairorgasinCPVCpipeorttings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD2774 UndergroundInstallationofThermoplasticPressurePiping
ASTMD2846 CPVCPlasticHotandColdWaterDistributionSystem
ASTMF493 SolventCementsforCPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
NSFStandard14 PlasticPipingComponentsandRelatedMaterials
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
All pipe and fittings shall be manufactured from CPVC compound with a cell class of 24448 for pipe and
23447forttingsasperASTMD1784,conformwithNSFInternationalStandard14.Thepipeshall
belistedbyNSFInternationalforreclaimedwaterandbearthemark“NSF-rw.”
1⁄2”through2”sizes:ReUze
®
made with FlowGuard Gold
®
CPVCCopperTubeSizemanufacturedto
standarddimensionratio(SDR)11andshallconformtoASTMD2846.Pipeshallbepurplepigmented
andhavetworowsofmarking180˚aparttoincludeWARNING: NON-POTABLE WATER DO NOT
DRINK”.Fittings shall be either tan or purple in color.Transition ttings shall have brass male or
female connections with integral CPVC socket connections as manufactured by Charlotte Pipe and
Foundry Company.
All pipe and fittings shall be produced by a single manufacturer and be installed in accordance with
manufacturer’s recommendations and applicable code requirements. System shall be joined using
approvedone-stepsolventcementconformingtoASTMF493.Pipeandttingsshallbemanufactured
by Charlotte Pipe and Foundry Company and are intended for hot and cold non-potable water distribution
systems.
Product Specifications
GENERAL INFORMATION
ReUzeisaregisteredtrademarkofCharlottePipeandFoundryCompany.
19
Product Specifications
System: PVC SDR 35 Gravity Sewer Pipe
Scope: ThisspecicationcoversPVCStandardDimensionRatio(SDR)35PSMpipeforgravitysewerandsurface
water applications with a pipe stiffness of 46. This product is intended for gravity applications where the
operating temperature will not exceed 140°F.
Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class
of12364asidentiedinASTMD1784.Therequirementsofthisspecicationareintendedtoprovide
pipe suitable for non-pressure drainage and surface water.
PVCSDR35PSMpipeshallconformtoASTMD3034forgasketorsolventweldpipewithaminimum
pipestiffnessof46.GasketsshallconformtoASTMF477.Theterm“PSM”isnotanacronym,but
rather an arbitrary designation for a product having certain dimensions.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, and building requirements. Buried pipe shall be installed
inaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemadeinatwostep
processwithprimerconformingtoASTMF656andsolventcementconformingtoASTMD2564.The
pipeshallbeprotectedfromchemicalagents,plasticizedvinylproducts,orotheraggressivechemical
agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation.
WARNING! Nevertestwithortransport/storecompressedairorgasinPVCpipeorttings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD3034 PVCGravitySewerPipe(SDR)35PS46
ASTMD2855 JointsForSewerPipeUsingSolventCement
ASTMD2564 SolventCementsForPVCSewerPipe
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF477 ElastomericSeals(Gaskets)ForJoiningPlasticPipe
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
*Note:Latestrevisionofeachstandardapplies.
Short Specification:
PipeshallbemanufacturedfromPVCcompoundwithacellclassof12364asperASTMD1784.PVC
SDR35PSMpipeshallconformtoASTMD3034forgasketorsolventweldpipewithaminimumpipe
stiffness of 46. Pipe shall be plastic sewer main outside diameter with a standard dimension ratio (SDR)
of35.GasketsshallconformtoASTMF477.
Allpipeshallbeproducedbyasinglemanufacturerandshallbeinstalledinaccordancewithmanufacturer’s
recommendations and applicable code requirements. Buried pipe shall be installed in accordance with
ASTMD2321andASTMF1668.SolventcementsshallconformtoASTMD2564,primershallconform
toASTMF656.PipeistobemanufacturedbyCharlottePipeandFoundryCompanyandisintendedfor
non-pressure gravity sewer and surface water applications.
GENERAL INFORMATION
20
Plastics Technical Manual
GENERAL INFORMATION
System: PVC D 2729 Sewer and Drain Pipe
Scope: This specification covers PVC D 2729 Sewer Pipe for drainage applications. This pipe is intended for
drainage applications where the operating temperature will not exceed 140°F.
Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class
of12454asidentiedinASTMD1784.
PVCD2729SewerPipedimensionsandphysicalpropertiesshallconformtoASTMD2729.Allpipe
shallbemanufacturedintheUnitedStates.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Found-
ry and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall
beinstalledinaccordancewithASTMD2321andASTMF1668.Solventcementjointsshallbemade
inatwostepprocesswithprimerconformingtoASTMF656andsolventcementconformingtoASTM
D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant,
plasticizedvinyl products, orotheraggressivechemicalagents notcompatiblewithPVCcompounds.
Systemsshallbehydrostaticallytestedafterinstallation.WARNING!Nevertestwithortransport/store
compressed air or gas in PVC pipe or fittings.
Referenced Standards*:
ASTMD1784 RigidVinylCompounds
ASTMD2729 PVCSewerPipe
ASTMD2564 SolventCementsforPVCPipeandFittings
ASTMF656 PrimerforPVCPipeandFittings
ASTMD2321 UndergroundInstallationofThermoplasticPipe(non-pressureapplications)
ASTMF656 PrimersforPVCPipeandFittings
ASTMF1668 ProceduresforBuriedPlasticPipe
*Note:Latestrevisionofeachstandardapplies.
3” PVC30030 10903 Solid 3.250 0.070 810 52.8
3” PVC30030P 11814 Perforated 3.250 0.070 810 52.8
4” PVC30040 10905 Solid 4.215 0.075 500 70.4
4” PVC30040P 11815 Perforated 4.215 0.075 500 70.4
PVC Sewer and Drain ASTM D 2729
Nominal UPC O.D. Min. Wall Wt/100
Size Part No. 611942- Type (In.) (In.) Ft/Skid (Lbs.)
Short Specification:
PipeshallbemanufacturedfromPVCcompoundwithacellclassof12454perASTMD1784.Pipe
dimensionsandphysicalpropertiesshallconformtoASTMD2729.
Allpipetobeproducedbyasinglemanufacturerandtobeinstalledinaccordancewithmanufacturer’s
recommendations and all applicable code requirements. Solvent cements shall conform to ASTM D
2564,primershallconform to ASTMF656.ThepipeistobemanufacturedbyCharlottePipeand
Foundry Company and is intended for drainage applications where the temperature will not exceed
140°F.
Perforation Detail
2-Hole 120 Degree
Product Specifications
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120

Charlotte Pipe CTS 12010 0500 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI