Carson MS-040 User guide

  • Hello! I am an AI chatbot trained to assist you with the Carson MS-040 User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How to turn on the light on the Carson MS-040 microscope?
    How to focus using the Carson MS-040 microscope?
    How to change the magnification on the Carson MS-040 microscope?
    How to clean the Carson MS-040 microscope?
    How to store the Carson MS-040 microscope when not in use?
7. Die geeignete(n) Lichtquelle(n) einschalten.
i. Bei durchscheinenden Präparaten wie biologischen Schnitten die Leuchtkrafteinstellung für die Durchlich-
tquelle drehen. Sie schaltet die Lichtquelle ein und regelt die Lichtstärke.
ii. Bei lichtundurchlässigen oder spiegelnden Präparaten die Leuchtkrafteinstellung für die Auichtquelle drehen.
Sie schaltet die Lichtquelle ein und regelt die Lichtstärke.
iii. Bei gemischt lichtdurchlässigen und undurchlässigen Präparaten können die Durchlicht- und Auichquelle
Okularleich eingeschaltet werden.
8. Fokussierung:
i. Ins Okular schauen. Es sollte ein weißes Bildfeld zu sehen sein.
ii. Den Fokussierknopf langsam drehen, bis das Bild vom Präparat scharf und kontrastreich dargestellt wird.
iii. Die Leuchtkraft der Lichtquelle einstellen, bis das Bild bestmöglich dargestellt wird.
ACHTUNG: Beim Fokussieren immer darauf achten, dass das Objektiv nicht bis auf das Präparat herunterstößt,
da dabei sowohl das Präparat als auch das Objektiv beschädigt werden können.
9. Vergrößerung:
i. Zur Änderung der Vergrößerung den Objektivrevolver so drehen, dass das gewünschte Objektiv senkrecht zum
Objekttisch steht. Fokussierung je nach Bedarf nachführen.
10. Farblter eignen sich zur Kontrasterhöhung, besonders bei Farbpräparaten. Zur Verwendung von Farbltern das
Filterrad drehen, bis der gewünschte Farblter hörbar einrastet.
Pege & Wartung:
• MitdemMikroskop sollte immervorsichtigumgegangenwerden.BerührungmitSchmutz,körnigenFragmenten,
Staub oder Feuchtigkeit ist zu vermeiden.
• Reinigung:
—Mikroskopkorpus:Gerätvom Netztrennen undSchmutzbzw.Staub miteinemweichen, leicht feuchten
Lappen abwischen.
Linsenoberächen (Okular oder Objektiv): Staub und körnige Fragmente vorsichtig mit einem leicht
feuchten MikrofasertuchoderCarsons Lens Cleanerentfernen.
• BeiNichtgebrauch dasMikroskop ambesten imOriginalbehältnis aufbewahren.
• BeimVersetzendasMikroskop amMetallhalsoderF desGrätekorpus’anfassen.DasGerätnicht anOkular,
Okularrohr oder Objektivrevolver anheben.
Technische Daten Carson Mikroskop MS-040:
• Einzelokular,Rohrneigung45°,360°drehbar
• Gesamtvergrößerung:40fach-400fach
• Okulare: WF10X
• Objektive: 4X,10X,40X
• Objekttisch:90mmx90mm
• KondensorNA0.65,Scheibenblende
• Beleuchtung: Auf- undDurchlicht, elektrischeLED-Beleuchtung
Okular Objektiv Gesamt-vergrößerung
10x 4x 40x
10x 10x 100x
10x 40x 400x
360°
Rotatable
Draw Tube
Reective Light Source
Focus Knob
Filter Wheel
Power
Intensity Knob
for Reective
Light Source
Base
Standard Included Accessories: 10xWideFieldEyepiece
Eyepiece
Objective Lens Turret
Stage Clips
Stage
Transmitted
Light Source
Intensity Knob for
Transmitted Light Source
(on opposite side)
Quick-Start Guide:
1. Placemicroscopeonasecuresurface.Youmayrotatethedrawtubetothefrontfacingpositionoranypreferred
360°position.
2. Inserttheroundendofthepowercordintothemicroscopespowerportontherearbottomsideofthemicro-
scope,andplugtheoppositeendofthepowercordintoanystandard110Voutlet.
3. Gentlyplacethenarrowendoftheeyepieceintothedrawtube.
4.
Rotatetheobjectivelensturretsothattherstobjectivelens(4xlabeledbyaredline)isperpendiculartothestage.
5. Positionyourdesiredspecimenonthestage,withyourareaofinterestlocatedinthecenterofthestage.
6. Usethestageclipstosecurelyholddownyourslideorspecimen.
INSTRUCTION MANUAL | MS-040
8
2070 5th Avenue
Ronkonkoma, NY 11779
Phone: 631-963-5000 • Toll Free: 1-800-967-8427
Email: [email protected] • Fax: 631-427-6749
Website: www.carson.com
Quick-Start Guide:
1. Placemicroscopeonasecuresurface.Youmayrotatethedrawtubetothefrontfacingpositionoranypreferred
360°position.
2. Inserttheroundendofthepowercordintothemicroscopespowerportontherearbottomsideofthemicroscope,
andplugtheoppositeendofthepowercordintoanystandard110Voutlet.
3. Gentlyplacethenarrowendoftheeyepieceintothedrawtube.
4.
Rotatetheobjectivelensturretsothattherstobjectivelens(4xlabeledbyaredline)isperpendiculartothestage.
5. Positionyourdesiredspecimenonthestage,withyourareaofinterestlocatedinthecenterofthestage.
6. Usethestageclipstosecurelyholddownyourslideorspecimen.
7. Turn on appropriate light source(s).
i. Fortransparentspecimenssuchasbiologicalslides,rotatetheintensityknobforthetransmittedlightsourceto
turnonthelightandtochangelightintensity.
ii.
Foropaque
orreflective specimens,rotate the intensityknob for thereflectivelightsourcetoturnonthelight
andtochangelightintensity.
iii. Formixedtransparentandopaquespecimens,youmayturnonboththereectiveandtransmittedlight
sources.
8. Focusing:
i.
Lookint
o
theeyepiece andyoushouldsee awhitefieldimage.
ii. Gentlyadjustthefocusknobuntiltheimageofthespecimencomesintoacrispfocus.
iii. Adjustlightintensityonlightsourcestoachievebestimage.
CAUTION: Alwaystakecarewhenfocusing,sothattheobjectivelensdoesnotcollidedownonthespecimen,as
youmaycausedamagetoobjectivelensand/orspecimen.
9. Magnication:
i. To change magnication, rotate the objective lens turret so that the desired objective lens is perpendicular to
thestage.Refocusasneeded.
10. Colorltersmaybeusedtoenhancecontrast,especiallyifusingstainedslides.Tousecolorlters,rotatelterwheel
until the wheel clicks into the desired color lter.
Care & Maintenance:
• Pleasetakecarewhenusingourmicroscope.Trytoavoidbringingyourmicroscopeintocontactwithanydirt,
debris, dust or moisture.
• Cleaning:
—Formicroscopebody,unplugpoweranduseasoftslightlydampclothtocleandustordirt.
—Foropticalsurfaces,suchastheeyepiecelensorobjectivelens,useaslightlydampmicroberclothor
CarsonsLensCleanerstogentlyremovedustordebris.
• Whennotinuse,itisbesttostoreyourmicroscopeinoriginalpackage.
Whenmovingthemicroscope,holdbythemetalneckorbaseofthemicroscopebody.
Donotholdbytheeyepiecelens,drawtube,orobjectiveturret.
Lens
Magnication
10x 4x
40x
10x
10x 100x
400x
2
360°
Drehbares
Okularrohr
Auicht-quelle
Fokussier-knopf
Filterrad
Ein / Aus
Leuchtkraft-einstellung für
Auicht-quelle
F
Standardlieferunfang: 10fach-Weitfeldokular
Okular
Objektiv-revolver
Klemm-halter für
Objekt-träger
Objekttisch
Durchlicht-quelle
Leuchtkraft-einstellung für
Durch-lichtquelle
(gegenüber)
Schnellstart-Anleitung:
1. Mikroskop aufsicherem Untergrundaufstellen.DasOkularrohr kanninFrontalstellungoderjedebeliebige360°-Po-
sition gedreht werden.
2. DasrundeEndedesNetzkabelsindieNetzbuchsehintenunteninsMikroskop einstecken, dasandere Endedes
Netzkabelsineinenormale110V-Netzsteckdosestecken.
3. DasrundeEndedesOkularsvorsichtiginsOkularrohr einführen.
4. DenObjektivrevolver sodrehen, dassdaserste Objektiv(4x,mitroterLiniegekennzeichnet) senkrechtzumObjek-
tivtisch steht.
5. DasgewünschtePräparataufdemObjekttischpositionieren. Derzubetrachtende Bereich kommt indieMitte des
Objekttisches.
6. DenSchnittoderdieProbemitdenKlemmhalternfürdenObjektträger sicherfestklemmen.
BedIeNUNgSANLeITUNg | MS-040
7
Eyepiece
Objective
10x
40x
Total
MS-040 ©2018-REV1
/