Carson MS-160 is a versatile binocular microscope with 40X-1600X magnification, allowing you to explore the microscopic world in great detail. Its 360° rotatable head and double-layer mechanical stage provide easy navigation and positioning of specimens. The Abbe condenser with iris diaphragm and filter holder ensures optimal illumination and contrast adjustment. Additionally, the LED illumination provides bright and consistent light for clear observations.

Carson MS-160 is a versatile binocular microscope with 40X-1600X magnification, allowing you to explore the microscopic world in great detail. Its 360° rotatable head and double-layer mechanical stage provide easy navigation and positioning of specimens. The Abbe condenser with iris diaphragm and filter holder ensures optimal illumination and contrast adjustment. Additionally, the LED illumination provides bright and consistent light for clear observations.

7. Fokussierung:
i. Ins Okular schauen. Es sollte ein weißes Bildfeld zu sehen sein.
ii. Den Abstand zwischen den beiden Okularen einstellen. Dazu die zwei Teile des Stereookularkopfes auseinanderziehen oder zusammen-
schieben, bis sich die zwei Bilder richtig überlagern.
iii. Den Fokussierknopf langsam drehen, bis das Bild vom Präparat scharf und kontrastreich dargestellt wird.
ACHTUNG: Beim Fokussieren immer darauf achten, dass das Objektiv nicht bis auf das Präparat herunterstößt, da dabei sowohl das Präparat als
auch das Objektiv beschädigt werden können.
iv. Die Leuchtkraft der Lichtquelle und/oder die Önungsgröße der Irisblende so einstellen, dass sich der maximal mögliche Kontrast ergibt.
ACHTUNG: Der Kondensor sollte möglichst 1-3 Millimeter von der Unterseite des Präparats entfernt sein. Diese Höhe lässt sich mit der Höhenein-
stellung des Kondensors regeln. Hier ist vorsichtig vorOkularehen, damit der Kondensor nicht gegen das Präparat stößt, sonst können sowohl der
Kondensor als auch das Präparat beschädigt werden.
8. Vergrößerung:
i.
Zur Änderung der Vergrößerung den Objektivrevolver so drehen, dass das gewünschte Objektiv senkrecht zum Objekttisch steht. Fokussier-
ung je nach Bedarf nachführen.
ii. Das 100fach-Objektiv ist ausschließlich für die Ölimmersionsmikroskopie konstruiert. Hier müssen sowohl Präparat als auch Objektiv mit Im-
mersionsölen benetzt werden (nicht im Lieferumfang enthalten).
iii. Die Okulare können auch gegen die mitgelieferten 16fach-Okulare ausgetauscht werden, um eine strärkere Gesamtvergrößerung zu erzielen.
9. Farblter eignen sich zur Kontrasterhöhung, besonders bei Farbpräparaten. Zur Verwendung der mitgelieferten Blaulter den Filterhalter (unter der
Irisblende) nach außen drehen, den Filter ach in das Oberteil des Halters einstecken und dann den Filterhalter ganz zurück in Stellung drehen.
Pege & Wartung:
• MitdemMikroskop sollte immervorsichtigumgegangenwerden.BerührungmitSchmutz,körnigenFragmenten, Staub oderFeuchtigkeitistzu
vermeiden. Bei Nichtgebrauch die Staubabdeckung über das Mikroskop stülpen.
• Reinigung:
Mikroskopkorpus: Gerät vom Netz trennen und Schmutz bzw. Staub mit einem weichen, leicht feuchten Lappen abwischen.
Linsenoberächen (Okular oder Objektiv): Staub und körnige Fragmente vorsichtig mit einem leicht feuchten Mikrofasertuch oder Carsons
Lens Cleaner entfernen.
• Beilängerem Nichtgebrauch dasMikroskop ambesten imOriginalbehältnis aufbewahren.
• BeimVersetzendasMikroskop amMetallhalsoderF desGrätekorpus’anfassen.DasGerätnicht anOkular,Okularrohr oderObjektivrevolver anheben.
• Wenn dieFokussierungoderVerschiebung desObjekttischessteif undschwergängigwird,benötigendiemechanischgleitenden Teile derFokus-
sierschiene bzw. des Objekttisches ein wenig Schmierung durch ein oder zwei Tropfen des mitgelieferten Öls.
• Esmusssichergestellt sein,dassdasMikroskop ausgeschaltet undvom Netzgetrenntist.
• Zum Austausch derSicherungdieBodenabdeckungönen.DazuerstdiesechsGummischrauben unddieKlappenschrauben entfernen.Dann
die alte Sicherung entfernen und gegen die mitgelieferte Ersatzsicherung austauschen. Bodenabdeckung und Schrauben wieder anbringen.
Technische Daten Carson Mikroskop MS-160:
• Stereookular,Rohrneigung30°,360°drehbar
• Gesamtvergrößerung:40fach-1600fach
• KoaxialeGrob-undFeineinstellungsknöpfe
• Okulare: 4X,10X,40X,100XOIL
Okular Objektiv Gesamt-vergrößerung
10x 4x 40x
10x 10x 100x
10x 40x 400x
10x 100x 1000x OIL
16x 4x 64x
16x 10x 160x
16x 40x 640x
16x 100x 1600x OIL
OIL
OIL
• Objekttisch:zweidimensional verstellbarer Objekttisch,130mmx140mm
• Abbe-KondensorNA1.25,mitIrisblendeundFilterhalter
• Beleuchtung: elektrischeLED-Beleuchtung
Standard Included Accessories:
10xand16xWideFieldEyepiece,
Dust Cover, Blue Color Filter, Spare LED and Fuse
Binocular
Head
Objective
Lens Turret
Slide Clip
Mechanical
Stage
Condenser
Diaphragm
With Iris Control
Filter Holder
Power Switch
& Condenser Height Knob
(on left side, not shown)
Eyepieces
360°
Rotatable
Draw Tube
Coarse Focus
Knob
Fine Focus
Knob
Stage Knob
Light
Intensity
Knob
Light Source
Base
Quick-Start Guide:
1. Place microscope on a secure surface.
2. Inserttherstendofthepowercordintothemicroscopespowerportontherearbottomsideofthemicroscope,andplugtheoppositeendof
thepowercordintoanystandard110Voutlet.
3. Gentlyplacethenarrowendofeach10xeyepieceintoeachofthedrawtubesinthebinocularheadofthemicroscope.
4. Turnonthelightsourcebyturningthepowerswitchtotheonposition.
5. Rotatetheobjectivelensturretsothattherstobjectivelens(4xlabeledbyaredline)isperpendiculartothestage.
6. Positionyourdesiredslideonthemechanicalstageandsecurewithslideclip.Usethestageknobsforfront-back(topknob)andleft-rightmo-
tion(lowerknob)untilyourareaofinterestislocatedinthecenterofthestage.
INSTRUCTION MANUAL | MS-160
8
2070 5th Avenue
Ronkonkoma, NY 11779
Phone:
631-963-5000 • Toll Free: 1-800-967-8427
Email: [email protected]Fax: 631-427-6749
Website: www.carson.com
7. Focusing:
i. Lookintotheeyepieceandyoushouldseeawhiteeldimage.
ii. Adjustthedistancesbetweenthetwoeyepiecesbypullingthetwopartsofthebinocularheadapartortogetheruntilthetwoimagesmerge.
iii. Gentlyadjustthefocusknobuntiltheimageofthespecimencomesintoacrispfocus.
iv. Adjustlightintensityonlightsourcestoachievebestimage.
CAUTION: Alwaystakecarewhenfocusing,sothattheobjectivelensdoesnotcollidedownonthespecimen,asyoumaycausedamageto
objective lens and/or specimen.
v. Adjustthelightintensityand/ortheirisofthediaphragmasneededtoachievemaximumcontrast.
CAUTION: Thecondensershouldideallybelocatedwith1-3millimetersofthebottomofspecimenslide.Theheightcanbeadjustedusing
condenserheightknob.Becarefulwhenadjustingthatthethatcondenserdoesnotcollidewiththespecimen,asyoumaycausedamageto
condenser and/or specimen.
8. Magnication:
i. Tochangemagnication,rotatetheobjectivelensturretsothatthedesiredobjectivelensisperpendiculartothestage.Refocusasneeded.
ii. The100xobjectiveisonlydesignedforoilimmersionmicroscopy,whereinthespecimenandobjectivelensarecoatedwithimmersionoils(notincluded).
iii. Youmayalsoswitchtheeyepiecestotheincluded16xeyepiecestoincreasetheoverallmagnication.
9. Colorltersmaybeusedtoenhancecontrast,especiallyifusingstainedslides.Tousetheincludedbluecolorlter,rotatethelterholder(lo-
catedunderthediaphragm)outwards,placethelteratinsidethetoppartoftheholderandthenfullyrotatethelterholderback
into position.
Care & Maintenance:
• Pleasetakecarewhenusingourmicroscope.Trytoavoidbringingyourmicroscopeintocontactwithanydirt,debris,dustormoisture.Placethe
dust cover the microscope when not in use.
• Cleaning:
Formicroscopebody,unplugpoweranduseasoftslightlydampclothtocleandustordirt.
Foropticalsurfaces,suchastheeyepiecelensorobjectivelens,useaslightlydampmicroberclothorCarsonsLensCleanerstogently
remove dust or debris.
Whennotinuseforlongperiods,itisbesttostoreyourmicroscopeinoriginalpackage.
Whenmovingthemicroscope,holdbythemetalneckorbaseofthemicroscopebody.Donotholdbytheeyepiecelens,drawtube,orobjec-
tive turret.
Ifthefocusingormechanicalstagemotionbecomesstiffandhardtomove,thesemechanicalslidingportionsonthefocusingtrackorthestage
maybelubricatedbyusingoneortwodropsofoil (not included).
Makesurethepowerisoffandthemicroscopeisunpluggedfromthepowersocket.
Toreplacefuse,openthebottomcoverbyfirstremovingthesixrubberscrewsandthedoorscrews.Thenremovetheoldfuseandreplacewith
includedspare.Replacebottomcoverandscrews.
Carson MS-160 Microscope Specications:
• BinocularInclinedTube30°,Rotatable360°
• TotalMagnication:40X-1600X
• CoaxialCoarseandFineAdjustmentKnobs
• Eyepieces:WF10X,WF16X
Eyepiece Objective Lens Total Magnication
10x 4x 40x
10x 10x 100x
10x 40x 400x
10x 100x 1000x OIL
16x 4x 64x
16x 10x 160x
16x 40x 640x
16x 100x 1600x OIL
OIL
OIL
Objectives:4X,10X,40X,100XOIL (oil not included)
WorkingStage:DoubleLayerMechanicalStage,130mmx140mm
NA1.25AbbeCondenser,withIrisDiaphragmandFilterHolder
Illumination:0.5WLEDElectricalIllumination
2
Okulare
360°
Drehbares
Okularrohr
Grobfokussier-knopf
Feinfokussier-knopf
Objekttisch
-einstellung
Leuchtkraft
-einstellung
Standardlieferunfang:
10fach-und16fach-Weitfeldokular,
Staubabdeckung, Blaulter, Ersatz-LED
und Sicherung
Stereo-okularkopf
Objektiv- revolver
Seitl. Klemm-halter
für Objektträger
Objekttisch,
verstellbar
Kondensor
Irisblende mit
Blenden-einstellung
Filterhalter
Netzschalter
& Höhenein-stellung Kondensor
(links, nicht abgebildet)
Lichtquelle
F
Schnellstart-Anleitung:
1. Mikroskop auf sicherem Untergrund aufstellen.
2. DaseineEndedesNetzkabelsindieNetzbuchsehintenunteninsMikroskop einstecken, dasandere Endedes
Netzkabels in eine normale 110V-Netzsteckdose.
3. Die runden Enden der zwei 10x-Okulare vorsichtig in die beiden Okularrohre des Stereo-Okularkopfs am Mikroskop einführen.
4. DieLichtquelleeinschalten. DazudenNetzschalter aufONstellen.
5. DenObjektivrevolver sodrehen, dassdaserste Objektiv(4x,mitroterLiniegekennzeichnet) senkrechtzumObjektivtischsteht.
6. Den gewünschten Schnitt auf dem Objekttisch positionieren und mit dem seitlichen Klemmhalter sicher
festklemmen. Mit der Objekttischeinstellung vor/zurück (oberer Knopf) und links/rechts (unterer Knopf) den zu betrachtenden Bereich in die
Mitte des Objekttisches bringen.
BedIeNUNgSANLeITUNg | MS-160
7
MS-160 ©2018-REV1
  • Page 1 1
  • Page 2 2

Carson MS-160 User guide

Category
Microscopes
Type
User guide

Carson MS-160 is a versatile binocular microscope with 40X-1600X magnification, allowing you to explore the microscopic world in great detail. Its 360° rotatable head and double-layer mechanical stage provide easy navigation and positioning of specimens. The Abbe condenser with iris diaphragm and filter holder ensures optimal illumination and contrast adjustment. Additionally, the LED illumination provides bright and consistent light for clear observations.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages