1 Introduction
1.1 Purpose of the Operating Guide
This operating guide provides information for safe instal-
lation and commissioning of the frequency converter.
The operating guide is intended for use by
qualied
personnel.
Read and follow the instructions to use the frequency
converter safely and professionally, and pay particular
attention to the safety instructions and general warnings.
Always keep this operating guide available with the
frequency converter.
VLT
®
is a registered trademark.
1.2 Additional Resources
Other resources are available to understand advanced
frequency converter functions and programming.
•
The VLT
®
AQUA Drive FC 202 Programming Guide
provides greater detail on working with
parameters and many application examples.
•
The VLT
®
AQUA Drive FC 202 Design Guide
provides detailed information about capabilities
and functionality to design motor control
systems.
•
Instructions for operation with optional
equipment.
Supplementary publications and manuals are available
from Danfoss. See www.vlt-drives.danfoss.com/Support/
Technical-Documentation/ for listings.
1.3
Manual and Software Version
This manual is regularly reviewed and updated. All
suggestions for improvement are welcome.
Table 1.1 shows the manual version and the corresponding
software version.
Edition Remarks Software
version
MG20MDxx The parameter list is updated to
reect software version 2.6x. Editorial
update.
2.6x
Table 1.1 Manual and Software Version
1.4
Product Overview
1.4.1 Intended Use
The frequency converter is an electronic motor controller
intended for:
•
Regulation of motor speed in response to system
feedback or to remote commands from external
controllers. A power drive system consists of the
frequency converter, the motor, and equipment
driven by the motor.
•
System and motor status surveillance.
Depending on
conguration, the frequency converter can
be used in standalone applications or form part of a larger
appliance or installation.
The frequency converter is allowed for use in residential,
industrial, and commercial environments in accordance
with local laws, standards, and emission limits as described
in the design guide.
Single-phase frequency converters (S2 and S4) installed
in the EU
The following limitations apply:
•
Units with an input current below 16 A and an
input power above 1 kW (1.5 hp) are only
intended for professional use in trades,
professions, or industries and not for sale to the
general public.
•
Designated application areas are public pools,
public water supplies, agriculture, commercial
buildings, and industries. All other single-phase
units are only intended for use in private low-
voltage systems interfacing with public supply
only at a medium or high-voltage level.
•
Operators of private systems must ensure that
the EMC environment complies with IEC
610000-3-6 and/or the contractual agreements.
NOTICE
In a residential environment, this product can cause
radio interference, in which case supplementary
mitigation measures may be required.
Foreseeable misuse
Do not use the frequency converter in applications, which
are non-compliant with specied operating conditions and
environments. Ensure compliance with the conditions
specied in chapter 8 Specications.
Introduction
VLT
®
AQUA Drive FC 202
4 Danfoss A/S © 10/2016 All rights reserved. MG20MD02