ADTRAN T1 Quick start guide

Type
Quick start guide

This manual is also suitable for

ADTRAN T1 is a versatile and reliable T1 device that provides high-speed data transmission and connectivity options for various applications. With its comprehensive features, it caters to the communication needs of businesses and organizations. Here are some of its key capabilities:

  • T1 Connectivity: ADTRAN T1 establishes a T1 connection, enabling high-speed data transfer over a dedicated line, ensuring reliable and efficient data transmission.

  • Network and CPE Interfaces: It features modular jacks for both network and customer premises equipment (CPE) connections. The network interface allows seamless integration with T1 circuits, while the CPE interface facilitates the connection of customer equipment, such as routers, switches, or PBX systems.

ADTRAN T1 is a versatile and reliable T1 device that provides high-speed data transmission and connectivity options for various applications. With its comprehensive features, it caters to the communication needs of businesses and organizations. Here are some of its key capabilities:

  • T1 Connectivity: ADTRAN T1 establishes a T1 connection, enabling high-speed data transfer over a dedicated line, ensuring reliable and efficient data transmission.

  • Network and CPE Interfaces: It features modular jacks for both network and customer premises equipment (CPE) connections. The network interface allows seamless integration with T1 circuits, while the CPE interface facilitates the connection of customer equipment, such as routers, switches, or PBX systems.

TSU CSU ACE P/N 1202022L1
For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide, 61202022L1-13A, September 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved
N
ETWORK
C
ONNECTION
P
INOUT
Pin Name Description
1 R1 RXDATA Receive data from the Network - Ring
2 T1 RXDATA Receive data from the Network - Tip
3, 6, 7, 8 UNUSED n/a
4 R TXDATA Transmit data towards the Network -
Ring
5 T TXDATA Transmit data towards the Network - Tip
Network
T1
T1
CPE T1 Device
PWR
12-48V- - -
350 mA
I
NSTALLATION
I
NFORMATION
An eight-position modular jack (labeled N
ETWORK
) is provided to
connect to the network T1 circuit. The pinout is provided on this Quick
Start Guide. See
Chapter 2, Installation
,of the TSU User Manual for
more information. An eight-position modular jack (labeled CPE) is
provided to connect to the customer equipment. The pinout is provided
on this Quick Start Guide. See
Chapter 2, Installation
,of the TSU CSU
ACE User Manual for more information.
The rear panel contains LBO dip switches for both the Network and CPE
interfaces. Detailed instructions on setting the switch positions are found
on the back of this sheet.
The TSU CSU ACE can be powered by either of the following methods:
1. Use the included NEC Class 2, 12V at 400 mA wall mount power
supply.
2. Connect to a reliably grounded 12-48 Vdc source which is electrically
isolated from the AC source.
Note: The branch circuit overcurrent
protection shall be a fuse or circuit breaker rated 48V, minimum to
10A, maximum.
Additional information can be found on the product CD which contains
the TSU User Manual, FAQs, Data Sheets, Applications, and White
Papers.
CPE C
ONNECTION
P
INOUT
Pin Name Description
1 R TXDATA Transmit data towards the Network -
Ring
2 T TXDATA Transmit data towards the Network - Tip
3, 6, 7, 8 UNUSED n/a
4 R1 RXDATA Receive data from the Network - Ring
5 T1 RXDATA Receive data from the Network - Tip
TSU CSU ACE P/N 1202022L1
Quick Start Guide, 61202022L1-13A, September 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved
N
ETWORK
LBO S
WITCH
P
OSITION
S
ETTINGS
Position 1 Position 2 Attenuation (dB)
On On 0
On Off 7.5
Off On 15
Off Off 22.5
CPE LBO S
WITCH
P
OSITION
S
ETTINGS
Position 3 Position 4 Position 5 Cable Length (feet)
Off Off On 0-133
On On Off 134-265
Off On Off 266-399
On Off Off 400-533
Off Off Off 534-655
T
EST
AND
M
ONITOR
A
CCESS
Two monitor jacks are provided on the rear panel for bridging the
received signals to allow in service circuit monitoring.
Four break-and-test jacks are provided on the rear panel for use in out-
of-service testing. These jacks bypass the connections of the modular
jacks. N
ET
I
N
and N
ET
O
UT
are used to simulate the network input and
output of the TSU CSU ACE. To test the CPE, a T1 Bit Error Rate Test
(BERT) test set can be used to simulate the network. E
Q
I
N
and E
Q
O
UT
can be used to simulate the CPE with a BERT test set, allowing the
network to be tested. The TSU CSU ACE on the other end of the circuit
can be looped back to test only the network.
  • Page 1 1
  • Page 2 2

ADTRAN T1 Quick start guide

Type
Quick start guide
This manual is also suitable for

ADTRAN T1 is a versatile and reliable T1 device that provides high-speed data transmission and connectivity options for various applications. With its comprehensive features, it caters to the communication needs of businesses and organizations. Here are some of its key capabilities:

  • T1 Connectivity: ADTRAN T1 establishes a T1 connection, enabling high-speed data transfer over a dedicated line, ensuring reliable and efficient data transmission.

  • Network and CPE Interfaces: It features modular jacks for both network and customer premises equipment (CPE) connections. The network interface allows seamless integration with T1 circuits, while the CPE interface facilitates the connection of customer equipment, such as routers, switches, or PBX systems.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI