  • Hello! I am an AI chatbot trained to assist you with the Honeywell Midas-M Quick Reference Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What installation safety precautions should be taken?
    Where can the Midas-M detector be installed?
    What approvals does the device have?
    What's included in the box with the transmitter?
    How do I mount the transmitter device?
    How do I connect the electrical wires?
    What commissioning steps should be taken?
    What are the physical specifications of the transmitter?
    What are the power requirements for the device?
3016M5000 Rev 01
MIDAS-M MULTI GAS TRANSMITTER
Fixed Single Point Extractive
Multi Gas Transmitter
QUICK
REFERENCE
GUIDE
Introduction
The Midas-M® is a Fixed Extractive Single Point with 4-in1 Multi Gas
Detector that draws a sample locally or from a remote point to a sensor
cartridge that is located inside the detector’s chassis. A wide range of toxic,
flammable and oxygen gas sensor cartridges are available that enable
detection of gases used or generated in the Semiconductor and other
manufacturing industries.
NOTE: MidasM is shipped from the factory with the security function
disabled. We strongly recommend enabling this function for safe use of
the detector. To enable it, select Set up > Security and type an 8 character
password.
Safety
CAUTION
Failure to observe the following precautions can cause injury to persons or
damage to property:
To minimize the risk of electrostatic charging, provide a suitable
ground connection, and install the equipment in such a way that no
accidental discharges occur.
When MidasM reaches the end of its life, it should be disposed of by
local regulations.
Do not use cleaning solvents or abrasives to clean the gas detector.
Do not attempt to modify the product in any way from the manufactur-
ers design or specification. Warranty will be void and malfunction of
the gas detector may result.
Use only genuine spare parts and accessories with MidasM. Malfunc-
tion may result if non-standard parts are used.
MidasM is suitable for ordinary locations only and must not be in-
stalled in hazardous locations.
Installation must be by the recognized standards of the appropriate
authority in the country concerned. For Europe, see EN6007914,
EN60079292, and EN6124114. For installations in North America,
the National Electrical Code (NFPA 70) should be strictly observed. All
the appropriate local and national regulations should be observed.
Sécurité
MISE EN GARDE
Le non-respect des précautions suivantes peut causer des blessures cor-
porelles ou des dégâts matériels:
Pour minimiser les risques de charge électrostatique, veillez à ce que
la mise à la terre soit adéquate et installez l’équipement de manière à
éviter toute décharge accidentelle.
Lorsque le MidasM arrive en fin de vie, il doit être éliminé conformé-
ment à la réglementation locale.
N’utilisez pas de solvants de nettoyage ou d’abrasifs pour nettoyer le
détecteur de gaz.
Ne tentez en aucun cas de modifier le produit à partir de la conception
ou des spécifications du fabricant. La garantie sera annulée et un
dysfonctionnement du détecteur de gaz pourrait en résulter.
Utilisez uniquement des pièces de rechange et des accessoires d’orig-
ine avec MidasM. Un dysfonctionnement peut survenir si des pièces
non standard sont utilisées.
MidasM ne convient qu’aux emplacements ordinaires et ne doit pas
être installé dans des endroits dangereux.
L’installation doit être conforme aux normes reconnues par l’autorité
compétente du pays concerné. Pour l’Europe, voir EN6007914,
EN60079292 et EN6124114. Pour les installations en Amérique du
Nord, le code national de l’électricité (NFPA 70) doit être strictement
observé. Toutes les réglementations locales et nationales appropriées
doivent être observées.
Approvals
Electrical UL/CSA/IEC/EN 610101
EMC EN 50270
ROHS
What’s in the Box
1 Transmitter device
2 Tubes (Large box only)
1 Quick Reference Guide
Overview
Mounting bracket assembly
Pump Module
Sensor cartridge
Main Module
1
2
3
4
5
6
7
8
9
10
11
12
Power LED
Alarm 1 LED
Alarm 2 LED
Fault LED
Selected channel number
indicator for menu operation
Device status icons
Bar graph for gas concentration display
Entry indicator for menu operation
Gas concentration
Unit
Gas name, menu, fault message
Buttons
Fault
Inhibit
Wireless Connected
Bluetooth Connected
Internal pump runningGas Calibration
in progress
Cancel
Device Status LED’s
Device Status Icons
Channel #1 Status
Channel #2 Status
Channel #3 Status
Channel #4 Status
Accept
Up
Down
12
1
5
7
8
6
9
10
11
2 3 4
Mounting the Transmitter Device
Open the door
Remove two screws
1
2
Carefully pull main chassis forward
3
4
5
Drill two holes 2.2 in
Partially screw the fixings into the mounting surface.
Place the mounting bracket assembly over the screws, so they pass
through the mounting holes and then slide down to locate in the slots.
Tighten the screws to secure the mounting bracket assembly.
1
2
3
4
5
2 X
Align the rounded corner at the lower of the main module with the sim-
ilar rounded corner at the bottom of the mounting bracket assembly
Slide the main module backward while pushing the main module up
after connecting with a mounting bracket so that the PCB and con-
nector and tubes engage simultaneously.
Ensure the PCB, connector, and tubes are fully engaged by firmly push-
ing the main chassis horizontally backward on the mounting bracket
assembly. DO NOT PUSH ON THE LCD AS THIS MAY DAMAGE IT.
Align the two fixing screws located at the bottom of the chassis with
the screw threads on the mounting bracket assembly.
Tighten the screws to secure the chassis to the mounting bracket
assembly.
6
7
8
7
6
8
2 X
Mounting the Transmitter Device
Remove the internal packing card securing the pump. Failure to
remove this packing will result in damage to the MidasM detector.
9
9
Mounting the Transmitter Device
Electrical Installation
Access for the electrical wires to the terminal module is made via the PG16
cable gland located at the bottom of the mounting bracket assembly. The
cable gland can be removed and replaced with a suitable conduit fitting if
required. The wire routing of a typical installation is shown in the following
diagram.
4-20mA
Controlled
Current Source
SWITCH
EXT
EXT
INT
INT
SWITCH
+
Internal
Power
Loads
-
Relay
Contact
Terminals
4-20mA Analog Output
Switches (4 Channels)
24Vdc Power Terminals
4-20mA Analog Output
Switches (4 Channels)
RJ45 Connector
Optimal
Relays
Connector
Power Switch
Cable Gland
The terminals used are suitable for conductors of 24 to 14 AWG (0.5 to
1.8mm Dia.). We recommend using the 16 AWG (1.5 mm Dia.) conductors.
If Power over Ethernet (PoE) is used to power the device, then 24 VDC
power must not also be connected to the device, (or conversely if 24 VDC
is used to power the MidasM, then electrical power via the Ethernet port
must not be applied). Failure to observe this requirement may cause dam-
age to the gas detection system and will not be covered by the standard
warranty.
When connecting the wires, ensure that the power switch is in the off
position.
Comissioning
WARNING
Before carrying out any work, ensure local and site procedures are
followed. Ensure that the associated control panel is inhibited to
prevent false alarms.
The following procedure should be followed carefully and only performed by
suitably trained personnel.
1. Ensure the detector is wired correctly.
2. Ensure that the correct sensor cartridge is fitted. (If the
cartridge has not been stored at room temperature, allow one
hour for equilibration.)
3. Ensure the on/off switch on the bottom of the mounting
bracket assembly is in the on position.
4. Apply power to the system.
5. After the startup routine, the detector will display the normal
operating mode.
6. Perform a leak test to ensure all connections are secure.
7. ‘Waiting…’ will be displayed on booting time.
8. Allow the detector to stabilize until the ‘Warm-up’ message
is no longer displayed after booting. The maximum warm-up
time is dependent on sensor type. Refer to individual cartridge
datasheets. Warm-up times are typically much faster.
9. Ensure the correct ID code is selected in Set-up -> alarm
menu
10. If this is a first-time startup, the “Detect New Cartridge ~”
message could be displayed. Press the ‘O’ button to clear the
message.
Mise en service
ATTENTION
Avant de réaliser tout travail, s’assurer que les procédures locales
et de chantier sont suivi. Assurez-vous que le panneau de com-
mande associé est empêché de prévenir les fausses alarmes.
La procédure suivante doit être suivie attentivement et ne doit être effec-
tuée que par personnel convenablement formé.
1. Assurez-vous que le détecteur est câblé correctement.
2. Assurez-vous que la bonne cartouche de capteur est installée.
(Si la la cartouche n’a pas été conservée à la température
ambiante, laissez-la heure d’équilibration.)
Specifications
Part Numbers: MMT001: Transmitter (Main unit) of TCP/IP
MMT002: Transmitter (Main unit) of 420mA
output
MMC001: MidasM Sensor cartridge
Operating
Temperature:
0°C~40°C
Physical:
Size (unit with Sensor
cartridge)
136 mm(H) x 83 mm(W) x 152 mm (D) (5.35 x
3.27 x 5.98 in)
Weight – Transmitter 1.3 kg (2.87 lb)
Weight – Sensor
cartridge
0.17 ~ 0.22 kg (0.38 ~ 0.49 lb) dependent on
sensor type
Optional Relay
Dimensions:
Size 137 mm (H) X 84 mm (W) X 41 mm (D) (5.39 X
3.31 X 1.61 in)
3. Assurez-vous que l’interrupteur marche / arrêt est situé au
bas de la fixation. le support est en position de marche.
4. Mettez le système sous tension.
5. Après la routine de démarrage, le détecteur affichera le mes-
sage normal mode de fonctionnement.
6. Effectuez un test d’étanchéité pour vous assurer que toutes
les connexions sont sécurisées.
7. ‘Waiting…’ sera affiché au moment du démarrage.
8. Laissez le détecteur se stabiliser jusqu’à ce que le mes-
sage «Préchauffage» n’est plus affiché après le démarrage.
Léchauffement maximum le temps dépend du type de cap-
teur. Voir la cartouche individuelle feuilles de données. Les
temps de réchauffement sont généralement beaucoup plus
rapides.
9. Assurez-vous que le bon code d’identification est sélectionné
dans Configuration -> Alarme menu
10. S’il s’agit d’un premier démarrage, le message “Détecter nou-
velle cartouche ~” le message pourrait être affiché. Appuyez
sur le bouton ‘O’ pour effacer le message.
Weight 0.31 kg (0.68 lb)
Power Requirements:
Operating Voltage 24 VDC Nominal 15 to +10% (20.4 to 26.4 VDC)
Operating Voltage
with Power over
Ethernet (PoE)
48 VDC PoE (IEEE 802.3af compliant)
Power Consumption:
Transmitter unit
(normal condition)¹
Typ. 5W
Transmitter unit
(full load condition)²
< 11.45W
Transmitter with
optional relay
< 12.9 W
Outputs:
Visual Alarm, power, fault LEDs, and LCD with all the
gas readings and events.
LEDs: Power(Green), Alarm 1 (Red), Alarm 2
(Red), Fault (Yellow)
Relays Alarm1, Alarm2, Fault Relays (3) rated 1.0 A @
30VDC or
1.0A @ 30Vdc or 0.5A @ 125Vac Max
10 uA @ 10 mV minimum, configurable as nor-
mally open or closed, latched or unlatched.
Analog 3 wire sink, 3 wire source, or 4 wire fully isolated;
0 to 21 mA. for each channel.
Digital
Communications
Modbus / TCP Ethernet / Power over Ethernet
(PoE)
¹ Normal condition:
(1) No gas alarm
(2) Without tube and pressure/vacuum
²Full load condition:
(1) 4-ch gas alarms are on
(2) Maximum tubing length and pressure/vacuum on the inlet/exhaust line
Contact Us
Americas
Honeywell Analytics
405 Barclay Boulevard
Lincolnshire, IL 60069
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Europe, Middle East, and Africa
Life Safety Distribution AG(LSD)
Javastrasse 2
8604 Hegnau
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Manuals and other information about this product are available at:
www.honeywellanalytics.com/en/products/MidasM
© 2019
Asia Pacific
Honeywell Analytics Asia Pacific Co. Ltd.
7F SangAm IT Tower, 434 Worldcup Buk-ro,
Mapo-gu, Seoul 03922
South Korea
Mainland China
Honeywell Industrial Safety Gas Detectors
Building#1, 555 Huanke Road Zhang Jiang
HiTech Park Pudong New Area Shanghai
201203, China
Tel: 02180386800
Fax: 02160246070
gaschina@honeywell.com
Taiwan
Honeywell Taiwan Ltd
6F2, No.8, ZiQiang S. Road, Jubei City,
30264 Taiwan
Tel: +88635169284
Fax: +88635169339
analytics.tw@honeywell.com
/