JB SH-35N Wireless Digital Gauge User manual

Type
User manual

JB SH-35N Wireless Digital Gauge will allow the user to accurately and quickly measure superheat and subcooling. The device connects to a smartphone via Bluetooth allowing the user to monitor data and manage settings remotely through the dedicated app. It features a temperature clamp for precise temperature measurement, a large display for easy reading, and a long battery life for extended use. The gauge is compatible with various refrigerants and allows the user to store their preferred refrigerants for quick access.

JB SH-35N Wireless Digital Gauge will allow the user to accurately and quickly measure superheat and subcooling. The device connects to a smartphone via Bluetooth allowing the user to monitor data and manage settings remotely through the dedicated app. It features a temperature clamp for precise temperature measurement, a large display for easy reading, and a long battery life for extended use. The gauge is compatible with various refrigerants and allows the user to store their preferred refrigerants for quick access.

QUICK START GUIDE
WIRELESS DIGITAL GAUGE FOR SUPERHEAT AND SUBCOOLING
SH-35N
1/4" Female Flare Fitting
1/4" Male Flare Fitting
Display Screen
Temperature Clamp
Power Button
Menu Selection Button
2JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
OPERATING INSTRUCTIONS
Powering On the SH-35N
Press and hold the Power Button for five seconds. A startup screen will display JB logo, Just Better™ and
product version number.
Powering Off the SH-35N
Press and hold the Power Button for four seconds.
SH-35N Display Features
Reading Measurements from SH-35N Display
Once the SH-35N is powered on it will display system pressure. Pressing the Menu Selection Button will cycle
through the different measurements available:
System pressure display
Temperature from temperature clamp
Battery Status Indicator
Refrigerant Selection
Superheat/Subcooling Selection
Bluetooth Connection Indicator
3
JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
Saturation temperature for selected refrigerant at the given pressure
Calculated superheat or subcooling based on selection
Changing Measurement of Superheat or Subcooling
Press the Power Button to enter menu options. Press the Power Button again to scroll between superheat and
subcooling.
Changing Favorite Refrigerant
Press the Power Button to scroll through the available refrigerants.
Press the Menu Selection Button to select refrigerant. The unit will store five refrigerants in the local memory.
The available refrigerants can be changed and updated through the SH-35N app.
4JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
CONNECTING TO SH-35N APP
1. Download the SH-35N app to your smart device from the Apple® Store or Google™ Play.
2. Open the SH-35N app and power on the SH-35N unit.
3. Enable Bluetooth® in your smart device settings and search for available units broadcasting. Select the
SH-35N unit you would like to pair with.
4. The SH-35N is now connected and ready for use—readings from the device will display on the app.
MAIN MENU OPTIONS
Apple and Apple Store are registered trademarks of Apple. Google and the Google Logo are registered trademarks of Google Inc.
JB Main Menu
Theme
Device Settings
About
Manual
Social Media
Advanced
Bluetooth Connection
Battery Status
5
JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
APP SETTINGS
Setting Atmospheric Pressure
1. Select the JB icon at upper left to expand menu and select Device Settings.
2. Set Atmospheric Pressure will be displayed and can be manually updated based on location.
Selecting Refrigerant Menu Options
1. Select the JB icon at upper left to expand menu and select Device Settings.
2. Go to Set Refrigerants and select up to five refrigerants for storage in the SH-35N unit memory. Only five
refrigerants may be selected at one time or an error message to deselect a refrigerant will display.
3. Once refrigerants are selected, press update to save or cancel to clear and exit.
JB Main Menu
Atmospheric Pressure
Refrigerant Selection
Cancel
Bluetooth Connection
Battery Status
Update
6JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
Selecting Refrigerant
1. From the main display screen, press the down arrow under Select Refrigerant at the upper left to access
saved refrigerant options.
2. Select refrigerant.
3. Once refrigerant is selected, the SH-35N unit display will also update.
Selecting Superheat or Subcooling
1. From the main display screen, press the down arrow under What Are You Measuring at the upper right to
access superheat or subcooling options.
2. Once superheat or subcooling is selected, the SH-35N unit display will also update.
JB Main Menu
Refrigerant Selection
Bluetooth Connection
Battery Status
Superheat/Subcooling
Selection
Update
7
JB INDUSTRIES • SH-35N Quick Start Guide • 630.851.9444 • [email protected]
MAINTENANCE
Cleaning Vacuum Sensor
1. Fill brass sensor fitting with a few drops of isopropyl alcohol.
2. Cover the opening with a finger and gently shake to allow alcohol to rinse the sensor.
3. Pour out alcohol and allow sensor to dry for 20 minutes before using gauge.
PARTS LIST
PART NO. DESCRIPTION
SH-35N Digital vacuum gauge for superheat/subcooling includes temperature
clamp, power charger and carrying case
SH-35CL Temperature clamp
SH-56 Wet socks (5)
SH-35N-CS Carrying case
8SH-35N Quick Start Guide • 630.851.9444 • [email protected]
RETURN FOR REPAIR
Every effort has been made to provide reliable, superior quality products. However, in the event your instrument
requires repair, please contact JB Customer Service Department to obtain a Return Goods Authorization (RGA)
number. Ensure that all returned products are packed to avoid any damage in shipment. Paperwork should be
placed in a separate plastic bag and should include JB’s assigned RGA number, a description of the problem
and any customer assigned repair or purchase order number, if applicable.
Contact Customer Service for RGA number:
800.323.0811 Toll
800.552.5593 Toll Fax
Products should be shipped with freight prepaid to:
JB Industries
RGA#_________
601 N. Farnsworth Ave.
Aurora, IL 60505
630.851.9444 Tel
630.851.9448 Fax
WARRANTY
The SH-35N is warrantied against defects in materials and workmanship for one year from date of purchase. JB
products are guaranteed when used in accordance with guidelines and recommendations. Warranty is limited
to the repair, replacement, or credit at invoice price, (our option) of products which, in our opinion, are defective
due to workmanship and/or materials. In no instance will we allow charges for labor, expense or consequential
damage. Repairs performed on items out of warranty will be invoiced on a nominal basis; contact wholesaler
for details. Additional product information available online at www.jbind.com.
WARNING: This product can expose you to chemicals including lead which are known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
JB INDUSTRIES
0518
©2018 JB Industries, Inc. Printed in the USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

JB SH-35N Wireless Digital Gauge User manual

Type
User manual

JB SH-35N Wireless Digital Gauge will allow the user to accurately and quickly measure superheat and subcooling. The device connects to a smartphone via Bluetooth allowing the user to monitor data and manage settings remotely through the dedicated app. It features a temperature clamp for precise temperature measurement, a large display for easy reading, and a long battery life for extended use. The gauge is compatible with various refrigerants and allows the user to store their preferred refrigerants for quick access.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI