Pure Blue H2O PB-1DCS4M114M User manual

Type
User manual
Pure Blue H2O, LLC
13813 Monroes Business Park
Tampa, FL 33635 USA
www.pureblueh2o.com • [email protected]
(844) 787-3148 • (844) PURE-1-4-U 2017.11 #E1616
SINGLE STAGE DIRECT CONNECT
WATER FILTRATION SYSTEM
INSTRUCTION MANUAL for MODEL(s):
PB-1DCS2M114M, PB-1DCS4M114M and PB-1DCS6M114M
Read this Manual BEFORE using this equipment.
This will not only familiarize you with the system, but it will help you determine the best location for
installation whether under a sink or in a remote location. Helpful diagrams follow. Keep this manual
for future reference.
WARNING: Do not use with microbiologically unsafe water or of unknown quality without adequate
disinfection before or after the system. System is intended to be installed using the cold water supply
only.
Operational Parameters
Installation must be in compliance with state and local plumbing regulations.
21
Maximum Minimum
Operating Temperatures: 100°F (37.8°C) 40°F (4.4°C)
Operating Pressure: 100 psi (7.03 kg/cm2) 30 psi (2.11 kg/cm2)
pH Parameters: 11 2
Maintenance of System Replacement for Filters as follows:*
System Part Number Filter Part Number Replacement
PB-1DCS2M114M PB-2CBM114 Every 6 months
PB-1DCS4M114M PB-4CBM114 Every 6 months
PB-1DCS6M114M PB-6CBM114 Every 6 months
*May vary, depending on quality of incoming water.
(A). System Head with
Attachable Bracket Assembly
(B). Direct Connect Filter
(C). Direct Connect Fitting
(D). Mounting Screws
(E). 3/8” White Tubing
(F). 3/8” Blue Tubing
(G). 3/8” Elbow Adapter
(H). Electronic Monitor
A.
B.
C.
D.
E.
F.
G.
H.
(System Head)
(Mounting Bracket)
ElbowAdapter.pdf 1 6/30/17 11:40 AM
ElbowAdapter.pdf 1 7/7/17 9:29 AM
REQUIRED TOOLS & MATERIALS
Phillips Head Screwdriver • Tape Measure
Adjustable Wrench • Safety Glasses
Utility Knife • Pencil
Drill and 1/8” Drill Bit • Pan or Bucket
22
PACKAGE CONTENTS
PRECAUTIONS
For cold water use only. Do not use on hot water line.
After prolonged periods of non-use (such as vacation) it is recommended that the system be ushed
thoroughly. Let water run 5-6 minutes before using.
The lters recommended for use with this system carry a limited service life. Changes in taste, odor,
color and/or ow of the water being ltered indicate that the cartridge should be replaced.
Make certain that installation complies with all state and local laws and regulations.
See the Performance Data Sheet for contaminants and reduction performance.
WARNING: Filter system must be protected against freezing temperatures, frost, snow, sleet, and ice.
Exposure to these elements can produce cracks and product failures.
CAUTION: Please wear safety glasses to protect eyes when drilling.
NOTE: Turn o water supply to head and remove the lter if it must be left unattended for an extended
period of time.
23
SPECIFICATIONS
System Part Number Certication Flow Rate (GPM) Capacity
PB-1DCS2M114M 0.75 389
PB-1DCS4M114M 1.25 651
PB-1DCS6M114M 1.50 784
PREPARE SITE FOR INSTALLATION
Prior to starting, close the cold water shut-o valve.
NOTE: You must check and comply with all local plumbing codes.
Consult your local plumbing codes and install accordingly.
Position on cabinet wall in a space that provides easy access for future lter replacements and is within
reach of water supply using tubing provided.
If you have anything other than exible hose under your sink, check to see if you need to purchase
special ttings.
24
(C)
Direct
Connect
Fitting
3/8 White Tube
3/8 Blue Tube
STANDARD INSTALLATION
FILTER INSTALLATION
NOTE: Mount the lter system to a solid cabinet or wall. If a solid surface is not available, use hollow-wall
anchor bolts or toggle bolts (not included) to secure to the wall. May stand freely.
25
1. Turn o the cold water supply line, then turn on the kitchen faucet and
allow water to drain from line.
2. Disconnect the cold water faucet supply line from the cold water supply
angle stop.
3. Connect the Direct Connect Fitting to the cold water supply angle stop
as shown. Connect the cold water faucet supply line onto the top of the
Direct Connect Fitting. With an adjustable wrench, tighten the adapters
until secure. NOTE: Do not over tighten or strip threads as leaking may
occur.
4. Choose an easy-to-access area under the sink to mount the lter system.
NOTE: Allow a 2” clearance below the system to allow space for lter
replacements. The lter system must be mounted in a vertical position
and the lter head should be mounted on a stud or rm surface. Please
be advised that the lter can stand freely if mounting is not an option,
but be sure it remains in a verticle upright position.
5. Using the mounting bracket, mark with a pencil the holes for the
mounting screws on the wall surface. Using a 1/8” drill bit, drill two pilot
holes for the mounting screws. Insert mounting screws into the wall
with a screwdriver leaving approximately 1/4” of each mounting screw
exposed and hang the System Head on the eyes of the bracket.
NOTE: Image shown, is one (1) of three (3) mounting style brackets.
(C)
(A)
26
Questions? Call Product Support Toll-Free at 1-844-787-3148
(A)
(F)
(A)
(E)
(C)
NOTE A.
COLLAR
COLLET/PORT
6. Determine lengths of 3/8” tubing needed to connect the System Head
inlet (white collet/tubing) and outlet (blue collet/tubing) to the water
supply adapter (reference image left for inlet (white collet) and outlet
(blue collet) location). Be sure to allow enough tubing to prevent kinking
in the line. If necessary, cut each 3/8” plastic tubing squarely on both
ends with a utility knife, making sure not to crimp the tubing during
cutting. Make sure tube edges are even and smooth. Reference image 6
on left for inlet and outlet location.
7. Insert the 3/8” white tubing into the white inlet port/collet of the System
Head approximately 5/8” until it stops. Connect the other end of the
tubing to the bottom inlet side of the Direct Connect Fitting (C) adapter.
Repeat same process with outlet side (3/8” blue tubing and blue outlet
port/collet). NOTE: 3/8” Elbow adapter (G) has been included to use in
System Head for tubing connection, if necessary.
8. Line up lter head inlet and outlet ports and key with the inlet/outlet
ports on System Head, insert lter by pushing upward, and turning right
until the lter stops in the locked position. The lter should be tight
with no movement. If the lter is dicult to insert into the System Head,
check the lter and head ports for debris and make sure they are clean;
make sure both the inlet/outlet ports and O-rings are clean for easier
insertion and repeat this step.
9. Turn on the cold water supply at angle stop valve. Check for leaks. Turn
on faucet and allow water to run for 5 minutes to ush air and carbon
nes (very ne black powder). Check for leaks before leaving installation.
If problems exist, refer to troubleshooting on page 9.
NOTE: Routine maintenance and lter replacement will not require that
you disconnect the tubing from the System Head. If necessary, tubing
may be easily removed from the tting. First turn o the water supply to
the lter. Open the kitchen faucet to release water pressure. Using your
ngers, press in the collet holding it rmly against the tting, with your
other hand pull the tubing out of the collet, away from the head assembly.
See collet/port location in the image on the left, labeled NOTE A.
27
1. INSTALLING BATTERIES
To install the battery pull out the battery tray and insert the battery into the designated slot.
NOTE: Battery size: CR2032
2. MONITOR SETUP
Press the Reset Button to start time calculation. You should hear one beep and see a green light on
the LED display.
3. MONITOR NOTIFICATIONS
a. The light will blink green once every 60 seconds and will maintain that status for approximately
5 1/2 months.
b. Once the 5 1/2 month time limit has been reached the LED light will blink yellow once every
60 seconds.
c. Once the full 6 month time limit has been reached the Led light will blink red once every 60
seconds. You will also hear two beeps once an hour until the lter is changed and the battery
is reset/replaced or until the battery dies.
4. RESET THE MONITOR
To reset the monitor, press the Reset Button, you will hear one beep and the LED light will ash green
one time.
5. LOW BATTERY ALERT
This Electric Monitor does not have a low battery alert. You can easily check that your battery is still
running by looking at the monitor for one full minute. You will see the LED light ash once every
60 seconds. NOTE: To avoid the risk of the battery dying we recommend replacing the battery every
6 months. We highly recommend you write the lter installation date in a visible spot on the lter body.
USER’S INSTRUCTION MANUAL FOR ELECTRONIC MONITOR
Buzzer
Hole
LED
Reset
Top Case
Bottom
Case
Battery
Tray
28
1. Turn o incoming water supply from the cold water supply line.
2. Drain the excess cold water from the faucet supply line.
a. Turn the cold water faucet on (opening cold water ow) until no more
water comes out.
b. Turn o the faucet.
3. Remove the lter from the System Head/Mounting Bracket Assembly.
a. Turn the lter body one quarter turn to the left until it stops and pull
lter straight down.
b. Discard used/old lter.
4. Insert the new lter into the System Head/Mounting Bracket Assembly.
d. Align lter ports with the System Head port connections and push
lter upward into the System Head until it stops.
e. Turn the lter one quarter turn to the right until it stops in the locked
position.
CAUTION: Make sure there is no debris on the lter ports or in the
System Head ports when inserting the lter into the head, as it will not
seal properly. Repeat step 4 until it is inserted with a proper seal.
5. Turn on the incoming water supply from the cold water supply line.
a. Turn the cold water faucet on SLOWLY (opening cold water ow)
until water comes out smoothly.
b. Run water for 5 minutes, to ush air and carbon nes from lter.
c. Turn o the faucet.
CAUTION: Be sure to check system for leaks immediately after
installation or lter replacement, and periodically throughout the day to
ensure there is not an installation or lter replacement concern.
FILTER REPLACEMENT INSTRUCTIONS
NOTE: Preparing for lter removal, use a small pan, large bowl or towel to catch potential water drizzle from
pressurized water in lter system.
TROUBLESHOOTING
LEAKS BETWEEN THE SYSTEM HEAD ASSEMBLY AND THE FILTERS:
1. Turn o water supply to the lter system and dispense water from kitchen faucet until water and airow stops.
2. Remove lter and inspect o-rings to make sure they are in place and clean.
3. Install lter making sure the lter is pushed all the way into the head and turned all the way into the
open/locked position.
4. Turn on the water supply and check for leaks.
29
ADDITIONAL SYSTEM PERFORMANCE INFORMATION
Systems certied for cyst reduction may be used on disinfected water that may contain lterable cysts.
NOTE: See Product Data Sheet (PDS) for specications.
LEAKS AROUND THE FITTINGS:
1. Turn o the water supply to the lter system to relieve pressure.
2. While pressing the collet rmly against its inlet/outlet port of the direct connect tting or System Head
on the inlet/outlet port using your ngers, use your other hand to pull the 3/8” plastic tube straight out
of the inlet/outlet collet/port.
3. Check the inlet/outlet ports and 3/8” tubing to make sure that all is clear of debris.
4. Check the 3/8” tubing to make sure the end is evenly cut (at), free of scratches or jagged edges, and is
not crimped.
5. If any of the above damage to the 3/8” tube exists, use a utility knife or tube cutters to evenly cut the
damaged tubing o.
6. Re-install the 3/8” tubing into the inlet/outlet collet/port of the direct connect tting or System Head.
7. Turn the water supply to the system back on and check for leaks.
Call Customer Support for assistance at 1-844-787-3148
Visit us online at www.pureblueh2o.com
1-YEAR LIMITED MANUFACTURER’S WARRANTY
This warranty applies to the filter housing. It does not apply to any disposable filter cartridge where life expectancy varies
with the water being filtered. This warranty covers defects in material and workmanship only for a period of 1-year from
the original date of delivery. Pure Blue H2O, LLC agrees, during the warranty period, to replace or repair any part which
is deemed to be defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or
improper use after delivery, or (2) it has been repaired by someone not approved by Pure Blue H2O, LLC. Pure Blue H2O,
LLC is not responsible for damage in transit. Claims for such damage should be presented to the carrier by customer. This
warranty does not cover any labor, transportation, or shipping expenses incurred. The hiring of any individual or service
to install or maintain this product is done at the discretion and expense of the purchaser.
This product has been designed solely for use as a housing for a disposable filter cartridge. It is NOT warranted
against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or
deterioration caused by uses for which the product was not expressly intended.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION,
ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASER’S SOLE AND
EXCLUSIVE REMEDY, IN NO EVENT SHALL PURE BLUE H2O, LLC BE LIABLE FOR ANY ANTICIPATED OR LOST
PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER THEORY,
INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT.
PURE BLUE H2O, LLC DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS
BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF.
For servicing under this warranty, YOU MUST call Pure Blue H2O, LLC Product Support at 1-844-787-3148 for instructions
and authorization to return this product within the 1-year warranty period. Any items returned to Pure Blue H2O, LLC
without an authorized return identication number will not be accepted and returned to purchaser as undeliverable.
Make sure you retain a copy of the original purchase order included in delivery.
For servicing under this warranty, return any defective part to the
address listed below within 1-year from date of purchase.
Pure Blue H2O, LLC
13813 Monroes Business Park
Tampa, FL 33635 • USA
Technical Support: M-F 8:30am - 5:00pm (EST)
1-844-787-3148 • (844) PURE-1-4-U
www.pureblueh2o.com • [email protected]
10
Pure Blue H2O, LLC
13813 Monroes Business Park
Tampa, FL 33635 USA
www.pureblueh2o.com
(844) 787-3148 • (844) PURE-1-4-U
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Pure Blue H2O PB-1DCS4M114M User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI