Gefen GEF-DVIKVM-848DL-PB User manual

  • Hello! I am an AI chatbot trained to assist you with the Gefen GEF-DVIKVM-848DL-PB User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
8x8 DVIKVM
Du
a
l Link M
a
trix
w/ Push Button
Contro
l
G
EF-DVIKVM-
8
4
8
DL-P
B
Use
r M
a
n
ual
w
ww.
g
efen
p
ro.co
m
1080P
ASKING FOR ASSISTANC
E
Rev B
2
T
echnical Su
pp
or
t
:
Telephone
818
772-910
(
800
)
545-690
0
Fax
(
818
)
772-912
0
T
echnical Su
pp
ort Hours
:
8
:00 AM - 5:00 PM Monda
y
- Frida
y
, Paci
c Tim
e
For 24
/
7 support, see the back o
f
the product
f
or the support number
Write To
:
G
e
f
en LL
C
c/
o
C
ustomer
S
ervic
e
2
0600
Nordho
ff
S
t
C
hatsworth,
C
A 9131
1
www.
g
e
f
enpro.com
s
upport
@g
e
f
enpro.com
Notic
e
G
e
f
en LL
C
reserves the ri
g
ht to make chan
g
es in the hard ware, packa
g
in
g
and
an
y
accompan
y
in
g
doc u men ta tion without prior written notice.
8
x8 DVIKVM Dual Link Matrix with Push Button Contro
l
is a trademark o
f
G
e
f
en LL
C
©
2011
G
e
f
en LL
C
, All Ri
g
hts Reserve
d
All trademarks are the propert
y
o
f
their respective owners
CONTENT
S
1 Intr
oduc
ti
on
2
O
peration Notes
3
Features
4 Front Panel La
y
ou
t
5
Front Panel Descriptions
6
Back Panel La
y
ou
t
7 Back Panel Descriptions
8
C
onnectin
g
The 8x8 DVIKVM Dual Link Matri
x
8
Wirin
g
Dia
g
ram
9
Front Panel Displa
y
10 IR Remote
C
ontrol Unit La
y
ou
t
11 IR Remote
C
ontrol
U
nit Installatio
n
12 IR Remote
C
ontrol Unit
C
on
g
uratio
n
13 Usin
g
the IR Remote
C
ontrol Uni
t
14
O
peratin
g
The 8x8 DVIKVM Dual Link Matri
x
14 Routin
g
S
ources
15
Sy
stem Lock Mod
e
15 Returnin
g
to
S
tandb
y
Mod
e
16
Cy
clin
g
between In
f
ormation
S
creens
17 Activatin
g
/
Deactivatin
g
S
tandb
y
Mod
e
17
S
avin
g
the Downstream EDID to Local Memor
y
19
S
avin
g
the De
f
ault EDID to Local Memor
y
20
S
avin
g
the current Routin
g
S
tat
e
21 Recallin
g
a Routin
g
S
tat
e
22 Maskin
g
O
utputs
2
3
R
S
-2
3
2
S
erial
C
ontrol
24 R
S
-2
3
2
/
Telnet
C
ommands
24 EDID Mana
g
emen
t
29 IP
/
Telnet
C
on
g
uratio
n
37 Routin
g
40 Maskin
g
4
3
Miscellaneous
5
1 Web Inter
f
ac
e
5
1
C
on
g
urin
g
the IP Address
5
2 View Matrix
S
tatus
5
7 Mana
g
e EDID
6
3 Maskin
g
6
4 IP
C
on
g
uratio
n
6
5 Backup
/
Restor
e
6
6 Power Mana
g
emen
t
6
8 Network
C
able Wirin
g
Dia
g
ram
6
9 Firmware Updat
e
71 Rack Mount
S
a
f
et
y
In
f
ormatio
n
72
S
peci
cations
73 Warrant
y
74 Licensin
g
1
INTRODUCTIO
N
C
on
g
ratulations on
y
our purchase o
f
the 8x8 DVIKVM Dual Link Matrix. Your
c
omplete satis
f
action is ver
y
important to us.
G
efenPRO
In the realm o
f
video distribution, certain
f
eatures are invaluable in a commercial
or broadcast environment. Accommodations such as a built-in power suppl
y
and
at black rack-mount enclosures set
G
e
f
enPR
O
apart
f
rom our traditional
p
roducts.
C
omplex distribution units allow
f
or pro
f
essional DVI, 3
G
-
S
DI, and
H
DMI si
g
nals to be routed and converted easil
y
and seamlessl
y
, while bein
g
backed up b
y
a renowned and dependable technical support team.
G
e
f
en invites
y
ou to explore the
G
e
f
enPR
O
product line and hopes that
y
ou
nd the solution
that
ts
y
our needs.
T
he GefenPRO 8x8 DVIKVM Dual Link Matri
x
The
G
e
f
enPR
O
8x8 DVIKVM Dual Link Matrix with Push Button
C
ontrol provides
a pro
f
essional-
g
rade KVM solution to route DVI, U
S
B, and Audio
f
rom an
y
ei
g
ht
c
omputers to an
y
ei
g
ht Hi-De
f
workstations. Dual link resolutions up t
o
3
840 x 2400 are supported. Audio can be routed with the video or independentl
y
f
rom the video usin
g
mini-stereo cables to provide
f
ull multimedia content
f
or
di
g
ital si
g
na
g
e applications. The
f
ront panel displa
y
shows the current routin
g
s
tatus and the
f
ront panel push buttons are used to mana
g
e local source routin
g
.
Four methods are available
f
or controllin
g
the
G
e
f
enPR
O
8x8 DVIKVM Dual Link
M
atrix:
f
ront panel push buttons, an included IR remote, a built-in R
S
-23
2
inter
f
ace, or b
y
usin
g
IP control via the built-in Web inter
f
ace.
How It Works
C
onnect up to ei
g
ht KVM source devices to the
G
e
f
enPR
O
8x8 DVI KVM Dual
Link Matrix with Front Panel Push Button
C
ontrol usin
g
the supplied DVI cables.
C
onnect up to ei
g
ht monitors to the DVI outputs.
C
onnect the U
S
B devices
(
ke
y
board, mouse device, etc.
)
to the U
S
B input and output connectors.
For audio, connect mini-stereo cables between each audio source and the audio
inputs on the Matrix.
C
onnect the mini-stereo cables between the audio outputs
on the Matrix to the audio device. Plu
g
in the power cord and appl
y
power to the
M
atrix. The DVI, U
S
B and Audio sources will be routed accordin
g
to the current
r
outin
g
selection.
OPERATION NOTE
S
2
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE 8X8 DVIKVM DUAL LINK MATRIX WITH PUSH
BUTTON CONTROL
The 8x8 DVIKVM Dual Link Matrix will not pass HD
C
P content
.
There is no internal scalin
g
in the 8x8 DVIKVM Dual Link Matrix. All o
f
the
attached monitors must be able to displa
y
the resolutions output b
y
the
s
ource devices. For maximum compatibilit
y
it is recommended that onl
y
one
c
ompatible
/
common resolution be used b
y
all o
f
the source devices.
Advanced EDID
f
eatures and IP con
g
uration
f
eatures are accessible via the
RS
-232 serial communication port.
S
ee pa
g
e 23
f
or more in
f
ormation.
R
outin
g
and EDID
f
eatures can be accessed via a web browser usin
g
the IP
c
ontrol
f
eature, built into the 8x8 DVIKVM Dual Link Matrix.
IMPORTANT
:
I
f
the unit is installed in a closed or multi-rack assembl
y
, do
no
t
b
l
oc
k th
e
v
e
ntil
a
ti
o
n h
o
l
es
of
th
e
e
n
c
l
osu
r
e
.
3
FEATURE
S
Features
S
upports resolutions up to 2560x160
0
Front panel control buttons
f
or local switchin
g
S
tatus L
C
D
(
shows routin
g
status
)
Advanced EDID mana
g
ement permits uploadin
g
o
f
custom internal or
e
xternal EDID settin
g
s
S
erial R
S
-232 inter
f
ace
f
or remote control via a computer or control
au
t
o
m
a
ti
o
n
de
vi
ces
• IP
C
ontrol
O
utput maskin
g
comman
d
• IR Remote
C
ontrol
• IR Ext
e
n
de
r
• Power
O
n
/Off
switc
h
Internal power suppl
y
G
roundin
g
Terminal
S
tandb
y
mod
e
S
upports DDW
G
standards
f
or DVI
Rac
k m
ou
nt
ab
l
e
P
acka
g
e Includes
(
1
)
G
e
f
enPR
O
8x8 DVIKVM Dual Link Matri
x
(
8
)
6
f
t. DVI Dual Link cables
(
M-M
)
(
8
)
Audio
C
ables
(
8
)
U
S
B
C
ables
(
1
)
IR Remote
C
ontrol Uni
t
(
1
)
A
C
Power
C
or
d
(
1
)
User Manual
4
P
ANEL LAYOU
T
Front Panel
4
5
6
1
2
3
7
5
P
ANEL DESCRIPTION
S
Front Panel
1
Input Buttons
(
1 - 8
)
U
sed
f
or routin
g
an Input to an
O
utput. Each o
f
these buttons represents an
Input.
S
ee pa
g
e 14
f
or more in
f
ormation on routin
g
DVI sources.
2
IR Windo
w
R
eceives si
g
nals
f
rom the IR Remote
C
ontrol
u
nit.
3
Power Switch
Turn the power on or o
ff
usin
g
this switch.
4 LCD Displa
y
Displa
y
s the current routin
g
status o
f
the Matrix and is also used to mana
g
e
s
ource routin
g
.
5 Power Indicato
r
This LED indicator will
g
low bri
g
ht red when the power is turned on.
6 Output Buttons
(
1 - 8
)
U
sed
f
or routin
g
an Input to an
O
utput. Each o
f
these buttons represents an
O
utput.
S
ee pa
g
e 14
f
or more in
f
ormation on routin
g
DVI sources.
7 Control Button
s
These buttons are used to control other
f
eatures on the product.
S
ee pa
g
es 14
- 22
fo
r
de
t
a
il
s
.
6
P
ANEL LAYOU
T
Back Panel
4
2
1
5
6
7
8
9
101
1
3
7
P
ANEL DESCRIPTION
S
Back Panel
1
RS-232 Serial Por
t
C
onnects to the R
S
-232 control device. The 8x8 DVIKVM Dual Link Matrix ma
y
be controlled remotel
y
usin
g
this port.
S
ee pa
g
es 23 - 50
f
or details.
2
AC 110 / 220V
(
50/60 Hz
)
Power Cable Receptacle
C
onnect the included A
C
power cord
f
rom this receptacle to an available
e
l
ec
tri
ca
l
ou
tl
e
t.
3
Fuse Drawe
r
Each power receptacle houses a
f
use drawer. Within each
f
use drawer are two
(
2
)
250 V
f
uses.
O
ne
f
use is active and the other is a spare.
4 DVI Input Ports
(
1 - 8
)
C
onnect DVI source devices to these ports.
5 IP Control Interface
C
onnect to this port to control the 8x8 DVIKVM Dual Link Matrix usin
g
IP
C
ontrol.
S
ee pa
g
e 51
f
or more in
f
ormation.
6 IR Extender Por
t
C
onnect an IR extender cable to this port.
7 USB Output Ports
(
16
)
C
onnect U
S
B devices to these ports
(
two outputs per channel
)
.
8
DVI Output Ports
(
1 - 8
)
C
onnect DVI monitors to these ports.
9 USB Input Ports
(
1 - 8
)
C
onnect U
S
B source devices to these ports
1
0 Audio Output Connector
(
3.5 mm Mini-Stereo
)
C
onnect audio devices to these ports usin
g
3.5 mm mini-stereo cables.
1
1 Audio Input Connectors
(
3.5 mm Mini-Stereo
)
C
onnect audio output devices to these ports usin
g
3.4 mm mini-stereo cables.
8
CONNECTING THE 8X8 DVIKVM DUAL LINK MATRI
X
How to Connect the GefenPRO 8x8 DVIKVM Dual Link Matri
x
1.
C
onnect up to 8 DVI source devices to the DVI inputs on the rear panel o
f
the
G
e
f
enPR
O
8x8 DVIKVM Dual Link Matrix usin
g
the supplied DVI cables.
2.
C
onnect up to 8 DVI monitor to the DVI outputs on the rear panel o
f
the
G
e
f
enPR
O
8x8 DVIKVM Dual Link Matrix with user-supplied DVI cables.
3
.
C
onnect the included A
C
power cable to the power receptacle on the rear
p
anel o
f
the
G
e
f
enPR
O
8x8 DVIKVM Dual Link Matrix.
C
onnect the opposite
e
n
d
of
th
e
cab
l
e
int
o
a
n
a
v
a
il
ab
l
e
e
l
ec
tri
ca
l
ou
tl
e
t.
Wirin
g
Dia
g
ram for the GefenPRO 8x8 DVIKVM Dual Link Matri
x
GEF-DVIKVM-848DL-PB
DVI Dual Link Displays
USB Keyboards
USB Mice &
PoweredSpeaker
DVI DUAL LINK CABLE
AUDIO CABLE
USB CABLE
8x
DVI Dual Link
Sources
USB Sources
Audio Sources
8x
Matrix
M
atr
i
x
RS-232 Controller
RS-232 CABLE
ETHERNET CABLE
IP Control
WARNING
:
This product should alwa
y
s be connected to a
g
rounded electrical socket.
9
OPERATING THE 8X8 DVIKVM DUAL LINK MATRI
X
Bootin
g
Up / Standb
y
Screen
The
f
ront-panel L
C
D o
f
the 8x8 DVIKVM Dual Link Matrix is a 16 character 2
l
ine displa
y
. This displa
y
is used to aid in per
f
ormin
g
routin
g
commands, as well
as displa
y
in
g
additional s
y
stem in
f
ormation. When the unit is powered on, the
f
ollowin
g
screens are displa
y
ed
:
A
f
ter a
f
ew moments, the standb
y
screen is displa
y
ed
:






10
IR REMOTE CONTROL UNIT LAYOU
T
1
Activity Indicato
r
This LED will be activated momentaril
y
each time a button is pressed.
2
M
onitor and Source Selection Buttons
(
1 - 16
)
Th
ese
bu
tt
o
n
s
a
r
e
used
t
o
se
l
ec
t whi
c
h
sou
r
ce
i
s
r
ou
t
ed
t
o
a
m
o
nit
o
r.
S
ee pa
g
e 13
f
or in
f
ormation on usin
g
the IR Remote
C
ontrol unit.
RMT-16IR
Remote Control Uni
t
1
2
1
1
IR REMOTE CONTROL UNIT INSTALLATIO
N
Installin
g
the RMT-16416IR Batter
y
1.
R
emove the batter
y
cover on the back o
f
the IR Remote
C
ontrol unit.
2. Insert the included batter
y
into the open batter
y
slot. The positive
(
+
)
side o
f
the batter
y
should be
f
acin
g
up.
3
.
R
eplace the batter
y
cover
.
The Remote
C
ontrol unit ships with two batteries.
O
ne batter
y
is required
f
or
operation and the other batter
y
is a spare.
Batter
y
Slo
t
WARNING
:
Risk o
f
explosion i
f
batter
y
is replaced b
y
an incorrect
t
y
pe. Dispose o
f
used batteries accordin
g
to the instructions.
12
IR REMOTE CONTROL UNIT CONFIGURATIO
N
How to Resolve IR Code Con icts
In th
e
e
v
e
nt th
a
t IR
co
mm
a
n
ds
f
r
o
m
o
th
e
r r
e
m
o
t
e
co
ntr
o
l
s
int
e
r
fe
r
e
with th
e
s
upplied IR Remote
C
ontrol unit, chan
g
in
g
the IR Remote
C
ontrol’s IR channel
will
x the problem. The IR Remote
C
ontrol unit has a bank o
f
DIP switches used
f
or settin
g
the IR channel.
The DIP switch bank is located underneath the batter
y
cover.
1
2
1
2
1
2
1
2
R
emote
C
hannel 2
:
R
emote
C
hannel
0:
D
efau
l
t
R
emote
C
hannel 1
:
R
emote
C
hannel
3:
L
eft: Picture o
f
the opened rear batter
y
c
ompartment o
f
the IR remote showin
g
the
e
xposed DIP
S
witch bank between the batter
y
c
h
a
m
be
r
s
.
It is important that the IR channel on the Remote
C
ontrol unit, matches the
IR channel set on the 8x8 DVIKVM Dual Link Matrix. For example, i
f
both
DIP switches on the IR Remote
C
ontrol unit are set to IR channel 0
(
both DIP
s
witches down
)
, then the 8x8 DVIKVM Dual Link Matrix must also be set to IR
c
hannel 0.
S
ee pa
g
e 47 on how to chan
g
e the IR channel on the 8x8 DVIKVM
D
ua
l Link M
a
trix.
1
3
U
SING THE IR REMOTE CONTROL UNI
T
IR Remote Control Ke
y
Mappin
g
Each input and output on the 8x8 DVIKVM Dual Link Matrix is represented b
y
a
button on the IR Remote
C
ontrol unit. The table below lists the correspondin
g
inputs
and outputs.
Remote Button
M
onitor / Sourc
e
1
1
2
2
3
3
4
4
55
6
6
77
8
8
Routin
g
Sources usin
g
the IR Remote Control uni
t
Issuin
g
a routin
g
command is a two step process. The
rst step is to select the
m
onitor where the source will be routed. The second step is to select the source.
Example
1
R
oute the source device connected to In 7 to the monitor connected to
O
ut
3
.
1. Press button 3
(
monitor 3
)
on the IR remote control unit.
2. Press button 7
(
source 7
)
on the IR remote control unit.
The source connected to In 7 will be routed to the monitor connected to
O
ut
3
.
Example
2
R
oute the source device connected to In 1 to the monitor connected to
O
ut 1.
1. Press button 1
(
monitor 1
)
on the IR remote control unit.
2. Press button 1
(
source 1
)
on the IR remote control unit.
The source connected to In 1 will be routed to the monitor connected to
O
ut 1.
1
4
OPERATING THE 8X8 DVIKVM DUAL LINK MATRI
X
Routin
g
Sources
In order to chan
g
e current routin
g
state
:
1 Press
S
et Button to activate Routin
g
Mode.
2 Press an
y
Input on the bottom row o
f
buttons
(
1 - 8
)
. The s
y
stem indicates
the current routin
g
status.
3
Press the desired
O
utput button.
O
ne or more
O
utput buttons ma
y
be
se
l
ec
t
ed
.
4 Press the
S
et button to complete the operation. The s
y
stem will remain in
R
outin
g
Mode.
S
elect the Inpu
t
S
elect the
O
utpu
t
Press the Set button
Press
the
Set
button
15
OPERATING THE 8X8 DVIKVM DUAL LINK MATRI
X
S
y
stem Lock Mod
e
Lockin
g
the Matrix prevents chan
g
es to an
y
o
f
the Matrix settin
g
s. This
f
eature
is use
f
ul in case an
y
o
f
the
f
ront panel buttons are pressed b
y
accident. Lockin
g
the Matrix also prevents chan
g
es usin
g
the IR Remote
C
ontrol Unit.
1 Press the Lock button to activate
Sy
stem Lock Mode.
2 Press the Lock button a second time to deactivate
Sy
stem Lock Mode.
Returnin
g
to Standb
y
Mod
e
Press the
C
ancel button, while in an
y
mode, to return to the
S
tandb
y
Mode
screen
.
Pr
ess
th
e
L
oc
k
bu
tt
on
Press the
C
ancel butto
n
1
6
OPERATING THE 8X8 DVIKVM DUAL LINK MATRI
X
C
y
clin
g
between Information Screens
Press the
C
ancel button, while in
S
tatus
C
heck Mode, to c
y
cle throu
g
h the
In
f
ormation
S
creens.
C
a
nce
l
C
a
nce
l
C
a
nce
l
Press the
C
ancel butto
n


/