and end users to save energy
.
We’
d lo
ve to hear your comments. Please call the Mark
eting Department at 888-RAB-1000 or email: mar
[email protected]INSTRUCTIONS
3"/4" Premium Downlight FA
C3R5.5/7/8.59FAUNVW
C3R5.5/7/8.59FAUNVM
C4R8/10/119FAUNVW
C4R8/10/119FAUNVM
MI PORTANT
WARNINGS:
•
•
•
•
•
•
•
•
•
•
•
•
Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.
To prevent early lamp failure, lamp should only be installed in operating environments ranging between-30℃ and +40℃
(-22°F and+104°F).
No user serviceable parts inside. To avoid electrical shock do not disassemble product.
below
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder
terminals, Instead installers should cut existing lampholder leads away from the lampholder and make new electrical
connections to lampholder lead wires by employing applicable connectors.
by authorities having jurisdiction.
appropriate electrical codes. The installation guide does not supersede local national regulations for electrical installations.
This device is not intended for use with emergency exits.
.
Min.90°C supply conductors.
CAREFULLY BEFORE INSTALLING FIXTURE. R TAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. READ E
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WHAT’S IN THE BOX TOOLS NEEDED
OPTIONAL ACCESSORIES
Downlight (1)
Template (1)Lumi Sticker (1)
DO NOT TO INSTALL OR OPERATE INCANDESCENT LAMPS IN THIS LUMINAIRE
AT T TEMP
THIS LUMINAIRE HAS BEEN MODIFIED TO OPERATE LED LAMPS.
REPLACE ONLY WITH RAB Lighting Inc.
RABLIGHTING.COM 888 722-1000
MODEL#
DLPLATE/SJ
New construction plate for Stud/Joist
DLPLATE/T
New construction or remodel plate for
T-grid ceilings
Plate
MIN.LUMINAIRE DIMENSION
DLPLATE/C3468R/NB
Mounting plate with nailer bar
CUT-OUT
T
E
M
P
L
A
T
E
Screw (2)