  • Hello! I am an AI chatbot trained to assist you with the Broan E(1,2) Coil Furnace Cabinet Kit Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Electric Furnace Coil Cabinet
Installation Instructions
For Use with E2 Series Electric Furnaces
Cabinet P/N 902976
These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes
require licensed installation/service personnel for this type of equipment. Read all instructions carefully before starting the installation.
INTRODUCTION
This coil cabinet is designed for upflow or downflow instal-
lations.
The cabinet is factory equipped with insulation, and to as-
sure a sealed fit with the electric furnace, the outside top and
bottom are factory equipped with gasketing (see Figure 1).
Review the furnace installation instructions for specific details
on return air, filtering systems, and installation requirements
before proceeding.
TYPICAL INSTALLATION OF UPFLOW SYSTEMS
NOTES:
• Systemsmaybeinstalledwithnon-ductedorducted
return air.
• Returnairprovisionsandltersarenotprovidedwith
the coil cabinet; the additional accessory upflow stand
provides both the return air and filtering systems and
must be used for non-ducted return air unless additional
provisions are made in the home.
• Removerefrigerantlineknockoutsonlywheninstalling
indoor coil of a air conditioning or heat pump system.
Refer to coil instructions for further coil installation details.
Non-Ducted Return Air System
1. After meeting all requirements from the furnace instal-
lation instructions, position coil cabinet, with inside
gasketed surface toward bottom, on top of optional
upflow stand or mounting platform (See Figure 2). En-
sure gasket on outside of cabinet remains intact (See
Figure 1). Secure with three or more fasteners at holes
provided.
2. Position furnace onto coil cabinet in upflow mode and
secure with two or more fasteners at holes provided
ensuring gasket on outside of cabinet remains intact.
3. Use optional upflow duct connector or field supplied
connector to attach furnace to overhead supply duct.
Ducted Return Air System
1. After meeting all requirements from the furnace instal-
lation instructions, mark floor opening(s) as shown in
Figure 3.
a. Provide minimum clearances at rear and left side walls
of closet for installation of furnace and wiring.
b. Cut floor opening on outside edge of marked line so
that opening is slightly larger than area marked.
Figure 2. Upflow Installation
Figure 1. Coil Cabinet
Inside Gasket
(MUST be on
bottom surface
for coil installa-
tion)
29"
(737 mm)
Insulation
Inside Gasket
(bottom only)
Outside Gasket
(bottom)
Outside Gas-
ket (top)
Optional Upflow
Duct Connector
Optional
Upflow
Stand
23 3/4"
(603 mm)
20"
(508 mm)
c. Additional provisions may be necessary for optional
air conditioning if refrigerant lines are installed other
than at the front of the furnace.
2. Position coil cabinet, with inside gasketed surface toward
bottom (see Figure 2), over floor cutout and secure with
three or more fasteners ensuring gasket on outside of
cabinet remains intact. (See Figure 1.)
3. Position furnace onto coil cabinet and secure with two
or more fasteners ensuring gasket on outside of cabinet
remains intact.
4. Use optional upflow duct connector or field supplied
connector to attach furnace to overhead supply duct.
TYPICAL INSTALLATION OF DOWNFLOW SYSTEMS
NOTES:
• Systemsmaybeinstalledwithnon-ductedorducted
return air.
• Filtersarenotprovidedwithcoilcabinet.
• Removerefrigerantlineknockoutsonlywheninstall-
ing indoor coil of a air conditioning or heat pump sys-
tem. Refer to coil instructions for further coil installa-
tion details.
Non-Ducted Return Air System (Alcove or Closet)
NOTE: The return air grille mounting frame is not needed
in this application since the filter will be accessed through
the coil cabinet door. The wall mount grille is recommend-
ed in place of the grille and frame assembly.
1. After securing the furnace as stated in its installation
instructions (with the exception of the attachment of the
return air grille mounting frame), position coil cabinet,
7076000
with inside gasketed surface toward bottom, on top of
furnace (See Figure 4). Ensure gasket on outside of
cabinet remains intact. Secure with two or more fasten-
ers at holes provided.
2. Remove filter and filter retainer from furnace and install
in top of coil cabinet. Blower may need to be removed
in order to remove filter retainer from furnace.
3. Ensure that the duct system is properly sized so as to
account for any additional external static pressure pro-
duced from this more restrictive filtering method with a
coil.
Ducted Return Air System (Alcove or Closet)
1. After securing the furnace as stated in its installation
instructions (with the exception of the attachment of the
return air grille mounting frame), position coil cabinet,
with inside gasketed surface toward bottom, on top of
furnace (See Figure 4). Ensure gasket on outside of
cabinet remains intact (see Figure 1). Secure with two
or more fasteners at holes provided.
2. Connect the field fabricated duct to top of coil cabinet
ensuring gasket on outside of cabinet remains intact.
3. A field supplied filter with a minimum unrestricted medium
area of 324 square inches must be installed in the duct
above coil and must be accessible for monthly cleaning
or replacement by the homeowner.
Figure 3. Floor Openings.
Figure 4. Downflow Installation
Inside Gasket
(MUST be on
bottom surface
for future coil
installation)
MIN1 3/4"
(45 mm)
23 3/4"
(604 mm)
3/4" (20 mm)
20"
(508 mm)
17 1/2"
(445 mm)
14"
(356 mm)
5 3/4"
(147 mm)
3 1/8"
(80 mm)
18 5/8"
(474 mm)
3"
(73 mm)
Furnace
Outline
Furnace
Outer Door
For
Optional
A/C Or H/P
REAR WALL OF ENCLOSURE
CENTER LINE
Specifications & illustrations subject to change
without notice or incurring obligations (01/14).
/