Tynetec ZXT900 D Advent XT2 Product information

Type
Product information

This manual is also suitable for

DIL SW
MAX 32 PER SITE
NETWORK
SYSTEM
REMOVE BOARD TO
TERMINATE THEN
REFIT AS SHOWN
USE TWISTED PAIR
24V
0V
SP1
SP2
MIC1
9V
0V
MIC
SPK
ADDRESS
SET
ZXT942/943 MOTOR ROOM INTERFACE
A00363
SPK
MIC
0V
9V
ZXT942/943 LIFT CALLPOINT
4 WIRES VIA LIFT CAR
TRAVELLING CABLE
87654321
ON
NOTE
NOT SUITABLE FOR
EXTERNAL USE.
1
2
3
4
5
7
"8"
"4"
"2"
"1"
SET ADDRESS 0 TO 31
ALL OFF
ALL ON = 0
= 31
FIT 4K7 RESISTOR ACROSS
TERMINALS 2 & 9
RS485+
RS485-
SET
BINARY
ADDRESS
12345678
ON
12345678
ON
B
A
LK2
A
B
LK1
ALL "OFF"
OPTIONADDRESS SELECT
A00497
ZXT940/941 MANAGER CALLPOINT
FIT LK1 IN
POSITION "A"
POSITION "A"
FIT LK2 IN
0V
KICK
POWER+
POWER-
RS485+
RS485-
ZXT910
ADVENT XT2 869MHz
NETWORK RX+ANTENNA
A00499
12345678 9
10
16
17
18
19
11
12
13
14
15
24
23
22
21
20
COM
0V
24V
A00499
87654321
ON
SP1
SP2
MIC2
A00539
24V
0V
SP1
SP2
MIC1
9V
0V
MIC
SPK
ADDRESS
SET
ZXT944 MOTOR ROOM INTERFACE
RS485+
RS485-
87654321
ON
SP1
SP2
MIC2
A00539
4 WIRES VIA LIFT CAR
TRAVELLING CABLE
ZXT944 LIFT CALL-POINT
9V
0V
MIC
SPK
"16"
OFF ACK ALL/ON INTELLIGENT
KICK
0V
N/O KICK SWITCH
(SUPPLIED BY OTHERS)
CH1
CH2
24V
0V
TX+
TX-
SP1
SP2
MIC1
SP1
SP2
MIC2
- CH1
- CH1
- CH1
- CH2
- CH2
- CH2
24V
0V
TX+
TX-
SP1
SP2
MIC1
SP1
SP2
MIC2
- CH1
- CH1
- CH1
- CH2
- CH2
- CH2
N/O KICK SWITCH
(SUPPLIED BY OTHERS)
CH1
CH2
IMPORTANT
FOR SYSTEMS WITH
V3.00 FIRMWARE
ONWARDS THE
NETWORK RX
CLOSEST TO THE
MANAGERS OFFICE
SHOULD BE SET
AS ADDRESS "0"
6NOT USED
FUNCTION
8OFF FOR XT2
ANGULAR±1°
600-OVER±1.2
100-600±0.8
0-100±0.4
DO NOT SCALE 321
B
A
DATEDESCRIPTIONMOD
Scale TITLE Drg No.
TOLERANCES
FileDrn. Chkd.
Drg No.
MOD No
THIRD ANGLE
ALL DIMENSIONS AND TOLERANCES
IN mm UNLESS OTHERWISE STATED
CUSTOMER: SHEET OF
cand property of LEGRAND ELECTRIC LTD - Communication with third parties is not allowed without permission.
R
Tynetec is a business unit of
Legrand Electric Ltd
Tel: (01670)352371 Fax: (01670)362807
All parts supplied must conform
to the requirements of the RoHs
directive (EU)2015/863 unless
otherwise specified and agreed
with Tynetec prior to shipment.
ZXT900
ZXT900
ZXT900E
SRR _ NTS
03210017 C-1 NTR DIL SW 7 FUNCTION
06/04/21
ADVENT XT2 CONTROLLER
PERIPHERAL DEVICES CONNECTION DETAILS
5 8
U
T
V
Q
R
P
S
H
G
I
L
J
K
Y
X
W
Z
O
M
N
C
B
A
F
D
E
Back-UPS 850
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Tynetec ZXT900 D Advent XT2 Product information

Type
Product information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI