Vaisala Divert User Interface User manual

Type
User manual

Vaisala Divert User Interface allows users to monitor the status of their refractometers and divert system, and to change parameters. With the addition of the switch panel, an emergency divert button, a header wash key, and a divert reset button can be added. The Divert User Interface connects to the DD-23 Divert System via Ethernet, and can be mounted in a control room or similar environment, or with the wall mounting adapter, it is also compatible with VESA 100 swivel arms. An optional table stand is also available.

Vaisala Divert User Interface allows users to monitor the status of their refractometers and divert system, and to change parameters. With the addition of the switch panel, an emergency divert button, a header wash key, and a divert reset button can be added. The Divert User Interface connects to the DD-23 Divert System via Ethernet, and can be mounted in a control room or similar environment, or with the wall mounting adapter, it is also compatible with VESA 100 swivel arms. An optional table stand is also available.

IM-EN-DI v. 2.00
Instruction Manual
Remote Divert User Interface
DI
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
PUBLISHED BY
Vaisala Oyj
Vanha Nurmijärvene 21, FI-01670 Vantaa, Finland
P.O. Box 26, FI-00421 Helsinki, Finland
+358 9 8949 1
Visit our Internet pages at www.vaisala.com.
General safety consideraons
Always power o the Remote divert user interface DI before accessing the connecons
behind the display. Vaisala recommends the installaon of an external power switch.
Warning! If this device is used against manufacturers instrucons, the protecon for
the user may be lost.
Warranty
For standard warranty terms and condions, see www.vaisala.com/warranty.
Please observe that any such warranty may not be valid in case of damage due to nor-
mal wear and tear, exceponal operang condions, negligent handling or installaon,
or unauthorized modicaons. Please see the applicable supply contract or Condions
of Sale for details of the warranty for each product.
Technical support
Contact Vaisala technical support at [email protected]. Provide at least the fol-
lowing supporng informaon:
• Product name, model, and serial number
• Name and locaon of the installaon site
• Name and contact informaon of a technical person who can provide further infor-
maon of the problem
For more informaon, see www.vaisala.com/support.
© Copyright Vaisala 2019. All rights reserved.
Disposal
When wishing to dispose of an obsolete instrument or any parts of an in-
strument, please observe local and naonal regulaons and requirements
for the disposal of electrical and electronic equipment.
Symbols and terms used in this manual:
This indicates a warning. It provides safety precauon informaon needed to
avoid injury while operang the system.
This indicates that something is important for the operaon of the system.
Note. Notes contain addional informaon and hints.
This product manual is delivered to the end user with a Vaisala K-PATENTS® product.
Informaon in this manual is subject to change without noce. When the manual is
changed, a revised copy is published at hp://www.vaisala.com/
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
© Copyright Vaisala 2019. All rights reserved.
Table of contents
1 Descripon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Mounng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1.1 DI network sengs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Main display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Event log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.4 Diagnoscs display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.5 Parameters display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.6 Trends display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.7 Refractometer informaon and sengs . . . . . . . . . . . . . . . . . . . . . . 15
4 Regular maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 Baery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5 Specicaons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
A EU declaraon of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
B Soware licence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
1 Descripon 1
© Copyright Vaisala 2019. All rights reserved.
1 Descripon
The Remote divert user interface DI is an oponal extension to Digital Divert Control
System DD-23. The DI allows the same use as the DD-23 remote (web) interface. The
Remote divert user interface DI displays concentraons, the temperature and the in-
strument statuses of the refractometers in the DD-23 system. The DI does not make
divert decisions, but it can be used to change divert system and refractometer sengs,
and such changes may cause the divert system to make a divert decision. With the
addional switch panel an emergency divert buon can be added, alongside a header
wash key and a divert reset buon.
Figure 1.1 DI with switch panel
2 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
2 Mounng
The Remote divert user interface DI is mounted in a control room or similar environ-
ment. It can be installed in a panel. With the wall mounng adapter it is also compable
with VESA 100 swivel arms. An oponal table stand PR-7611 is available from Vaisala.
275mm
195mm
152mm
296mm
Dia. 5.2 mm
142mm226mm
Panel mounting dimensions.
Figure 2.1 Panel mounng
The Remote divert user interface DI connects to the DD-23 Divert System via Ethernet.
A Plaorm 4 cable PR-8430 is connected between the Divert Unit and the DI.
2 Mounng 3
© Copyright Vaisala 2019. All rights reserved.
Figure 2.2 Wall mounng adapter Figure 2.3 Table stand PR-7611
4 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
SAFE SOLIDS
A
122.3
B
122.3
25.3125.31
P4-007
1 2 3
4 5 6
7 8 9
- 0 .
BACK
ENTER
SOLIDS ALARM DIVERT OVERRIDE
SOLIDS WARNING
A&B DIFFERENCE
MALFUNCTION
A IN OPERATION
SAFE SOLIDS
B IN OPERATION
LIGHT
TEST
ALARM
TEST
DIVERT
RESET
AUTOMATIC
OVERRIDE
EMERGENCY
DIVERT
1 2 3
4 5 6
7 8 9
- 0 .
BACK
ENTER
SAFE SOLIDS
A
122.3
B
122.3
25.3125.31
Not used
PR-23 REFRACTOMETER
PR-8230
PR-23 sensor cable
F
M
F
Divert User Interface, DI
1 x M12-4 pin, D-code, F (External Ethernet)
1 x M12-8 pin, A-code, F (System)
1 x M12-4 pin, A-code, M (24VDC, mA)
mA cable
PR-8430
Platform 4 cable
M12-8 pin, A-code, F+M
DD-23 + PR-8665
Internal ethernet cable
M12-8 pin, A-code, RJ-45
STR single
transmitter
STR single
transmitter
PR-8350
Power-mA cable M12
M12- 4 pin, A-code, F
max. 10m (33ft)
max. 90m (295ft)
max. 200m (656ft)
max. 200m (656ft)
PR-8230
PR-23 sensor cable
max. 200m (656ft)
100-240VAC
or 24VDC
100-240VAC
or 24VDC
100-240VAC
or 24VDC
Figure 2.4 DI connecons
2 Mounng 5
© Copyright Vaisala 2019. All rights reserved.
1 2
43
M12-4 pin D-code, female
Not in use
8
1
7
6
5
4
3
2
Front view
Pin1 Pin8
M12-4 pin A-code, male
Back plane
Divert interface (DI)
CAT6/CAT5E cable from DD-23
Front view
+ BLUE
- BROWN
+ WHITE
- BLACK
] Not in use
] 24V DC in
PR-8350-010
Cable 4x0,75mm2 (PUR) OD=6.0mm (0.24")
10m (30ft) standardm max. 100m (300ft)
Field plug PR-8681
RJ-45
PR-8350-010
Cable 4x0,75mm2 (PUR) OD=6.0mm (0.24")
10m (30ft) standardm max. 100m (300ft)
2
1
3 4
Front view
M12-8 pin A-code, female
Figure 2.5 DI connecon cables
6 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
The switches connect at the back of the oponal switch panel.
Figure 2.6 Switch connecons
3 Use 7
© Copyright Vaisala 2019. All rights reserved.
3 Use
The Remote divert user interface DI is operated by tapping the touch screen.The display
works also with gloves, or you can tap the screen with for example the blunt end of a
pen.
3.1 Startup
When you power up the DI for the rst me, you get an error message "No connecon"
as you don’t have connecon to your DD-23 system unl the IP address of your DD-23
is entered in the sengs. For that, tap Menu in the top right corner of the screen. Then
choose Parameters in the right-hand menu. Now you can tap the white eld next to
"DD-23 IP address" to enter the IP address of your Divert system.
Figure 3.1 Parameter page
Making the connecon to the DD-23 may take some me. When the message on the
le top changes e.g. to Safe solids, the connecon has been made. Now tap Back to
get to the Main display.
8 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
Figure 3.2 Entering the DD-23 IP address
3 Use 9
© Copyright Vaisala 2019. All rights reserved.
3.1.1 DI network sengs
Figure 3.3 IP sengs
of a DI
There are three dierent IP sengs in the DI:
• DD-23 IP address is the address of the DD-23 unit
• System IP address is SYSTEM connector address of DI unit
to connect to DD-23 unit
• Ethernet IP address is ETHERNET connector address for re-
mote use of DI unit
When connecng a stand-alone (non-networked) system, DD-
23 IP address is 192.168.100.25 and System IP address should
be set to 192.168.100.x where x is anything between 1-255
except 25. Subnet should be 255.255.255.0.
When connecng through a network, contact system admin for DD-23 IP address and
other sengs to avoid address conicts.
3.2 Main display
The Main display shows the status of both refractometers and the divert system.
Tap on Menu in the Main display to get addional informaon and to change parame-
ters. You can choose between Log, Diagnoscs, Parameters and Trends displays. The
one currently chosen has dark background in the navigaon bar on the right.
10 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
Figure 3.4 Main display
3 Use 11
© Copyright Vaisala 2019. All rights reserved.
3.3 Event log
The Log display shows the event log of the DD-23 system. 5000 lines of log entries are
shown, swipe the display to scroll up and down in the log.
Figure 3.5 Log display
12 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
3.4 Diagnoscs display
The Diagnoscs display shows all the informaon on your system. Tap and hold the
arrows to scroll up and down on the page. Alternavely you can drag the scroll bar (the
grey box) to scroll up and down.
Figure 3.6 Diagnoscs display
3 Use 13
© Copyright Vaisala 2019. All rights reserved.
3.5 Parameters display
The Parameters display allows you to change DD-23 parameters, if calibraon lock is
o. If calibraon lock is on, you cannot change the parameters and will get a warning
about this.
Figure 3.7 Parameters display
Figure 3.8 Calibraon lock warning
For more informaon on calibraon lock see DD-23 user manual, secon 5.1.
14 DI instrucon manual
Document/Revision No. IM-EN-DI/2.00 Eecve: September 2, 2019
3.6 Trends display
The Trends display shows the trends of the various measurement values, choose the
value on the le. The acve value has dark background, CONC in the graphic below.
Figure 3.9 Trends display
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Vaisala Divert User Interface User manual

Type
User manual

Vaisala Divert User Interface allows users to monitor the status of their refractometers and divert system, and to change parameters. With the addition of the switch panel, an emergency divert button, a header wash key, and a divert reset button can be added. The Divert User Interface connects to the DD-23 Divert System via Ethernet, and can be mounted in a control room or similar environment, or with the wall mounting adapter, it is also compatible with VESA 100 swivel arms. An optional table stand is also available.