Vaisala Compact User Interface User manual

Type
User manual
IM-EN-CI v. 2.00
Instruction Manual
Compact User Interface
CI
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
PUBLISHED BY
Vaisala Oyj
Vanha Nurmijärvene 21, FI-01670 Vantaa, Finland
P.O. Box 26, FI-00421 Helsinki, Finland
+358 9 8949 1
Visit our Internet pages at www.vaisala.com.
General safety consideraons
Warning! If this device is used against manufacturers instrucons, user safety may be
compromised.
Warranty
For standard warranty terms and condions, see www.vaisala.com/warranty.
Please observe that any such warranty may not be valid in case of damage due to nor-
mal wear and tear, exceponal operang condions, negligent handling or installaon,
or unauthorized modicaons. Please see the applicable supply contract or Condions
of Sale for details of the warranty for each product.
Technical support
Contact Vaisala technical support at [email protected]. Provide at least the fol-
lowing supporng informaon:
• Product name, model, and serial number
• Name and locaon of the installaon site
• Name and contact informaon of a technical person who can provide further infor-
maon of the problem
For more informaon, see www.vaisala.com/support.
Disposal
When wishing to dispose of an obsolete instrument or any parts of an in-
strument, please observe local and naonal regulaons and requirements
for the disposal of electrical and electronic equipment.
Symbols and terms used in this manual:
This indicates a warning. It provides safety precauon informaon needed to
avoid injury while operang the refractometer system.
This indicates that something is important for the operaon of the refractome-
ter system.
Note. Notes contain addional informaon and hints.
Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
Table of contents
1 Descripon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Mounng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1 Connecons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1.1 Refractometer cable connecon . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1.2 Ethernet cable connecon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1 Refractometer connecon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Acvang and removing apps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Conguring mA output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.4 Managing users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5 Ethernet connecon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 Baery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5 Specicaons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.1 Connector specicaons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
A EU declaraon of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
B Soware licence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1 Descripon 1
© Copyright Vaisala 2019. All rights reserved.
1 Descripon
The Compact user interface CI is a compact, light-weight display for monitoring and
operang a Vaisala K-PATENTS® refractometer. It is ideal for applicaons where prism
wash and addional inputs/outputs are not needed. CI is is operated by the touch-
screen display. It is mainly intended for control room environment. There is a protecve
cover available for industrial environment. CI has IP66 rang. An epoxy coated version
of the CI is recommended for eld installaons.
Figure 1.1 Compact user interface CI
2 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
2 Mounng
The Compact user interface CI can be mounted on a wall with a wall mounng adapter
or on a VESA 200x100 wall mounng arm, or on a table with a table stand. It also has
a panel mounng opon. The mounng locaon should be easily accessible.
Figure 2.1 Table stand
If the Compact user interface is installed in an industrial environment instead of a con-
trol room, a protecve display shield is recommended. To mount the display shield,
rst screw two M5x 12 DIN912 A2 screws in upper two holes of the CI frame. Then
install the hinges and shield to lower M5 holes with M5x12 ISO 14581 TX A2 screws.
2 Mounng 3
© Copyright Vaisala 2019. All rights reserved.
Figure 2.2 VESA wall mounng adapter
4 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
275mm
195mm
152mm
296mm
Dia. 5.2 mm
142mm
226mm
Panel mounting dimensions.
Figure 2.3 Panel mounng opon
2 Mounng 5
© Copyright Vaisala 2019. All rights reserved.
CI-004
Figure 2.4 Display shield installaon
CI-005
1
2
1
2
Slide cover upwards to unslot
upper screw.
Then cover is free to swing forwards
to max. rotation of 180°.
Figure 2.5 Opening the display shield
6 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
2.1 Connecons
PR-43
REFRACTOMETER
M-12-8 pin, A code, M
Unclassified area
PR-8430-____
Platform 4 cable
M12-8 pin, A-code, F+M
Ethernet, mA, 24V
Compact User Interface, CI
1 x M12-4 pin, D-code, F (External Ethernet)
1 x M12-8 pin, A-code, F (System)
1 x M12-4 pin, A-code, M (24VDC, mA)
M
F
max. 90m (295ft)
Refractometer with CI
OR
PR-8440-___
Ethernet cable for interfaces
M12-4 pin, D-code, M+M
Ethernet
M
M
max. 90m (295ft)
M
PR-8330-___
Ethernet cable for interfaces
M12-4 pin, D-code, M+RJ45
Ethernet
max. 90m (295ft)
PR-8350-010
Power-mA cable M12
M12- 4 pin, A-code, F
mA, 24V
F
10m (33ft)
Figure 2.6 CI connecons
2 Mounng 7
© Copyright Vaisala 2019. All rights reserved.
Figure 2.7 Connecng CI to power
2.1.1 Refractometer cable connecon
The refractometer is connected to the CI with a Plaorm 4 cable PR-8430, a M12 male-
female 8 pins A-coded cable. Refractometer connecon can be made while the CI is
powered. The maximum length of the PR-8430 cable is 90 meters (295 ), but with a
Plaorm 4 cable extender PR-8660 another max. 90 meters long Plaorm 4 cable can
be added, bringing the maximum total length to 180 meters (590 ).
2.1.2 Ethernet cable connecon
If you wish to connect the CI with e.g. a laptop, you can purchase Interconnecng cable
PR-8330 with a M12-4-pin connector in one end and a RJ-45 connector in the other end.
The ethernet connecon is used to get access to the CI web pages.
8 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
3 Use
Power up the CI. A startup display shows briey, then the CI goes into the Main display.
The CI is operated by tapping the touch screen. If you nd that the touch screen is
dicult to use with ngers, try tapping it with e.g. the blunt end of a pen or use your
nail instead of the whole ngerp. The screen works even when you are wearing gloves.
COMPACT USER INTERFACE CI
DISPLAYS
PR-43-A Process Refractometer 20
Main
Diagnostics Trend User authentication
Figure 3.1 Compact user interface displays
3 Use 9
© Copyright Vaisala 2019. All rights reserved.
Figure 3.2 Access applicaon data and conguraon by tapping applicaon window
3.1 Refractometer connecon
Refractometers connecon to the CI is congured under the tle Instrument in the
Sengs > Network menu. By default the refractometers IP address is congured via
BOOTP server running on the CI. To reconnect a refractometer you can just replug its
cable to the CI the IP address is congured automacally. Refractometer connecon
can be made while the CI is powered.
3.2 Acvang and removing apps
The Main display may be empty even when a refractometer is connected to the CI. This
means that an applicaon must be acvated. Go to Sengs > Applicaons, tap on the
empty applicaon slot and select the app type and source for that slot. Aer choosing
sengs for the app, tap Done to exit the setup.
Note: Acvang Recipe app is not possible in the Compact user interface CI. Recipe
app requires external inputs provided by the Mulchannel user interface MI.
10 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
The empty applicaon slot may contain an earlier app conguraon. In that case a dia-
log will open during app acvaon and the earlier app conguraon can be re-enabled.
If necessary the app can also be removed. Go to Sengs > Applicaons and tap Re-
move on the applicaon slot. Accept the removal by tapping Ok. The removed app’s
conguraon will be saved unl another kind of applicaon is added to the same slot.
Figure 3.3 Empty Main display. Tap Sengs to acvate an app
3 Use 11
© Copyright Vaisala 2019. All rights reserved.
Figure 3.4 Selecng an empty applicaon slot to acvate the app
Figure 3.5 Selecng a source to acvate the
app, here applicaon type Ref is already selected
12 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
Figure 3.6 Selecng and empty applicaon slot
that contains old refractometer app conguraon
Figure 3.7 The earlier app conguraon can be re-enabled
3 Use 13
© Copyright Vaisala 2019. All rights reserved.
Figure 3.8 If necessary, the app can also be removed
3.3 Conguring mA output
To set the mA output values tap anywhere in the applicaon window and then select
Calibraon > Sensor. In the list, tap the parameter you want to change, type the new
numbers with the number pad and approve the change by tapping Done. Minimum
and maximum values set the measurement range. If your measurement unit is CONC%
and you want to measure the range 15–25 CONC%, the output signal for minimum 15
will be 4 mA and for maximum 25 it’ll be 20 mA. Default mA sets an mA default output
value that the refractometer returns to in certain situaons. The value can be set to a
low or high mA value, e.g. 3.0 mA or 22 mA.
14 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
Figure 3.9 Select Sensor on Calibraon display to congure mA output
Figure 3.10 Congure the mA output parameters
3 Use 15
© Copyright Vaisala 2019. All rights reserved.
3.4 Managing users
Some funcons of the CI, e.g. calibraon, are only available to a user who is logged
into the system. The master user password is wrien on the delivery data sheet that is
shipped with the CI. However, K-Patents recommends that a user name and a password
is set separately for every user who needs to have frequent access to the restricted
funcons. Go to Sengs, then select Users to add and remove users. To add a new
user, tap + Add user. To remove a user, tap the name of that user, then Remove user.
Figure 3.11 Users display
3.5 Ethernet connecon
The CI has a built-in web server with a home page. The CI home page allows you to
browse les or upload an update or a license le. To access the CI web page use IP
address found under the tle Ethernet in the Sengs > Network menu.
The default IP address mode seng for the CI is Auto. In this mode the CI gets the
IP address from an external DHCP server. If that fails the IP address will fall back to a
stac IP seng. Alternavely IP address mode: Stac congures the CI to use a stac
IP address only. Aer choosing sengs for the network, tap Apply to save all sengs.
Aer factory reset the default IP address of the CI is 192.168.1.11.
16 Compact user interface instrucon manual
Document/Revision No. IM-EN-CI/2.00 Eecve: September 2, 2019
Figure 3.12 To access the CI web page use the
IP address found in the Sengs > Network menu
Figure 3.13 Steps to congure a stac IP address for CI
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Vaisala Compact User Interface User manual

Type
User manual

Ask a question and I''ll find the answer in the document