Shinko Quick Reference User manual

Type
User manual

This manual is also suitable for

S G T - - -
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
0:100 to 240 V AC, 1: 24 V AC/DC
*2
Output 2
*1
Output
*2
, Output 1
*1
Input
Series name
SGT: 1-output, SGTW: 2-outputs
SGTL: 1-output + Serial communication
*1 For SGTW only
*2 For SGT, SGTL only
(
For detailed input/output spec, refer to
the full
Instruction Manual.
)
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
DISP
key
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Custom display
mode 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
for 5 sec
MODE
key
Input
setting mode
Output 1
setting mode
Output 2
setting mode
Instrument
setting mode
Communication
setting mode
C
ustom
display
setting mode
Manual mode
D
OWN
key for
3 sec
key
for 3 sec
Input type
key
Input unit
key
Decimal
point place
key
Output 0%
value
key
Output
100% value
key
Indication
unit
key
Save
settings
key
Output 1
type
O
utput
1
decimal
point place
Indication
value at
output 0%
Indication
value at
output 100%
Output 1
low limit
Output 1
high limit
Output 1
Normal/Reverse
Save
settings
Output 2
type
O
utput
2
decimal
point place
Indication
value at
output 0%
Indication
value at
output 100%
Output 2
low limit
Output 2
high limit
Output 2
Normal/Reverse
Save
settings
Filter time
constant
Sensor
correction
I
nput
burnout
status
Indication
time
Auto/Manual
Manual mode
auto return time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default DisplayDefault Display
D
efault Display
Default Display
Default Display
Default Display
MODE
k
ey, or after
Manual mode auto return
time has elapsed.
key
key
key
key
for 3 sec
key
key
key
key
key
key
for 3 sec
key
key
key
key
key
key
key
key
MODE
key
MODE
key
MODE
key
MODE
key
MODE
key
key
for 3 sec
key
D
ISP
key
key
key
key
key
key
key
key
key
key
key
key
key
for 3 sec
key
key
key
key
for 3 sec
No.
1
No. 6
No.
1
No.
6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
No.
6
COM
QUICK REFERENCE [Applicable model: SGT, SGTW, SGTL] No.SGT12JE1 2018.10
Input type
K-200 to 1370 °C
K -200 to 200 °C
K 0 to 400 °C
J -200 to 1000 °C
J -200 to 200 °C
J 0 to 400 °C
R -50 to 1760 °C
S -50 to 1760 °C
B 0 to 1820 °C
E -200 to 800 °C
T -200 to 400 °C
T -100 to 100 °C
N-200 to 1300 °C
PL- 0 to 1390 °C
W5Re/W26Re
0 to 2315 °C
W3Re/W25Re
0 to 2315 °C
Input unit
°C
°F
Decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Indication unit
No unit
%
mA
V
°C
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
1
Output 1,2 decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
S
election Item List
Model Name
Circuit Configuration
SGT, SGTL
Setting Mode
Output 2 setting mode is available only for the SGTW.
Communication setting mode is available only for the SGTL.
If the MODE key is pressed for approx. 5 seconds in each setting
mode, the unit will move to the Default Display.
SGTW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
A
lphabet A B C D E F G H I J K L M
Indication
A
lphabet N O P Q R S T U V W X Y Z
Terminal Arrangement
SGT, SGTL SGTW SGTL only
RS-485 serial communication
Modular jack pin arrangement
Output 1,2 Normal/Reverse
Normal
Reverse
Input burnout status
Overscale
Underscale
Auto/Manual
Auto
Manual
Communication speed
9600 bps
19200 bps
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
Key Operation Flowchart
Display Mode
: Available only for the SGTW.
For the details of the display mode, refer to the full Instruction Manual.
Default Display
If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
Once the Default Display is set, the DISP key will be in lock status.
If the DISP key is pressed for approx. 3 seconds, the key lock status
will be cancelled.
If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
1 Not available for the SGTW.
For
S
GTL
和文は裏面をご覧下さい。
Output
circuit
Communi
-
cation
circuit
Modular
jack
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting
key circui
t
TC
+
-
+
-
CJA
Output 1
circuit
Output 2
circuit
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting
key circui
t
TC
+
-
+
-
CJA
+
-
1
2
4
6
3
7
8
10
11
1
4
5
9
13
14
12
  • Page 1 1

Shinko Quick Reference User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI